Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Refract Surg ; 29(12): 865-8, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24404610

RESUMO

PURPOSE: To report histopathologic findings in a case of bilateral corneal ectasia following intrastromal femtosecond laser presbyopia surgery. METHODS: Case report. RESULTS: A 56-year-old patient was referred for bilateral corneal ectasia. He was treated for hyperopia using LASIK twice in both eyes. A bilateral femtosecond laser intrastromal presbyopia correction was secondarily performed. The patient complained of progressive loss of distance visual acuity shortly after. Corneal topography showed a bilateral central corneal protrusion. Rigid contact lenses were successfully fitted on the right eye and, because the patient still complained, a deep anterior lamellar keratoplasty was performed in the left eye. Light and electronic microscopy of the corneal button revealed that the inner intrastromal incision crossed the LASIK interface and led to stromal bed dehiscence. CONCLUSION: This case illustrates that intrastromal refractive surgery should not be recommended in eyes previously treated by lamellar refractive surgery.


Assuntos
Doenças da Córnea/etiologia , Substância Própria/cirurgia , Hiperopia/cirurgia , Complicações Pós-Operatórias , Presbiopia/cirurgia , Doenças da Córnea/diagnóstico , Topografia da Córnea , Dilatação Patológica/diagnóstico , Dilatação Patológica/etiologia , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ , Masculino , Pessoa de Meia-Idade
2.
Mol Vis ; 17: 1192-202, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21617751

RESUMO

PURPOSE: Investigate the genotype-phenotype correlations for five TGFBI (transforming growth factor, beta-induced) mutations including one novel pathogenic variant and one complex allele affecting the fourth FAS1 domain of keratoepithelin, and their potential effects on the protein's structure. METHODS: Three unrelated families were clinically diagnosed with lattice corneal dystrophy (CD) and one with an unclassified CD of Bowman's layer. Mutations in the TGFBI gene were detected by direct sequencing, and the functional impact of each variant was predicted using in silico algorithms. Corneal phenotypes, including histological examinations, were compared with the literature data. Furthermore, molecular modeling studies of these mutations were performed. RESULTS: Two distinct missense mutations affecting the same residue at position 509 of keratoepithelin: p.Leu509Pro (c.1526T>C) and p.Leu509Arg (c.1526T>G) were found to be associated with a lattice-type CD. The novel p.Val613Gly (c.1828T>G) TGFBI mutation was found in a sporadic case of an Algerian individual affected by lattice CD. Finally, the Bowman's layer CD was linked to the association in cis of the p.Met502Val and p.Arg555Gln variants, leading to the reclassification of this CD as atypical Thiel-Behnke CD. Structural modeling of these TGFBI mutations argues in favor of these mutations being responsible for instability and/or incorrect folding of keratoepithelin, predictions that are compatible with the clinical diagnoses. CONCLUSIONS: Description of a novel TGFBI mutation and a complex TGFBI allele further extends the mutational spectrum of TGFBI. Moreover, we show convincing evidence that TGFBI mutations affecting Leu509 are linked to the lattice phenotype in two unrelated French families, contrasting with findings previously reported. The p.Leu509Pro was reported to be associated with both amyloid and non-amyloid aggregates, whereas p.Leu509Arg has been described as being responsible for Epithelial Basement Membrane Dystrophy (EBMD).


Assuntos
Lâmina Limitante Anterior/metabolismo , Distrofias Hereditárias da Córnea/genética , Proteínas da Matriz Extracelular/genética , Fator de Crescimento Transformador beta/genética , Adulto , Idoso de 80 Anos ou mais , Argélia/etnologia , Alelos , Sequência de Aminoácidos , Lâmina Limitante Anterior/patologia , Distrofias Hereditárias da Córnea/classificação , Distrofias Hereditárias da Córnea/epidemiologia , Distrofias Hereditárias da Córnea/etnologia , Distrofias Hereditárias da Córnea/patologia , Proteínas da Matriz Extracelular/metabolismo , Feminino , França/epidemiologia , Frequência do Gene , Estudos de Associação Genética , Ligação Genética , Genótipo , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Modelos Moleculares , Dados de Sequência Molecular , Mutação , Linhagem , Fenótipo , Fator de Crescimento Transformador beta/metabolismo
3.
Int J Radiat Oncol Biol Phys ; 65(3): 780-7, 2006 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-16647221

RESUMO

PURPOSE: This study reports the results of proton beam radiotherapy based on a retrospective series of patients treated for uveal melanoma at the Orsay Center. METHODS AND MATERIALS: Between September 1991 and September 2001, 1,406 patients with uveal melanoma were treated by proton beam radiotherapy. A total dose of 60 cobalt Gray equivalent (CGE) was delivered in 4 fractions on 4 days. Survival rates were determined using Kaplan-Meier estimates. Prognostic factors were determined by multivariate analysis using the Cox model. RESULTS: The median follow-up was 73 months (range, 24-142 months). The 5-year overall survival and metastasis-free survival rates were 79% and 80.6%, respectively. The 5-year local control rate was 96%. The 5-year enucleation for complications rate was 7.7%. Independent prognostic factors for overall survival were age (p < 0.0001), gender (p < 0.0003), tumor site (p < 0.0001), tumor thickness (p = 0.02), tumor diameter (p < 0.0001), and retinal area receiving at least 30 CGE (p = 0.003). Independent prognostic factors for metastasis-free survival were age (p = 0.0042), retinal detachment (p = 0.01), tumor site (p < 0.0001), tumor volume (p < 0.0001), local recurrence (p < 0.0001), and retinal area receiving at least 30 CGE (p = 0.002). Independent prognostic factors for local control were tumor diameter (p = 0.003) and macular area receiving at least 30 CGE (p = 0.01). Independent prognostic factors for enucleation for complications were tumor thickness (p < 0.0001) and lens volume receiving at least 30 CGE (p = 0.0002). CONCLUSION: This retrospective study confirms that proton beam radiotherapy ensures an excellent local control rate. Further clinical studies are required to decrease the incidence of postirradiation ocular complications.


Assuntos
Melanoma/radioterapia , Terapia com Prótons , Neoplasias Uveais/radioterapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Intervalo Livre de Doença , Fracionamento da Dose de Radiação , Enucleação Ocular/estatística & dados numéricos , Feminino , Humanos , Melanoma/mortalidade , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/radioterapia , Recidiva Local de Neoplasia/cirurgia , Estudos Retrospectivos , Taxa de Sobrevida , Neoplasias Uveais/mortalidade
4.
Retina ; 23(5): 641-6, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14574248

RESUMO

BACKGROUND: To describe the indications for removal of Miragel episcleral buckles and to compare them with removed silicone sponges and solid silicone indentations. METHODS: Retrospective analysis of the charts of patients successfully treated for retinal detachment in whom the episcleral buckle was removed after surgery, with a minimal follow-up of 6 months. RESULTS: In a series of 90 eyes of 90 patients, including 38 cases of Miragel elements, 25 cases of solid silicone, and 27 cases of silicone sponge removal, the duration of indentation before removal was significantly longer with Miragel (91.9 months) than with solid silicone (10.6 months) and silicone sponges (18.6 months). In eyes treated with Miragel elements, swelling of the material with progressive limitation of ocular motility and protrusion of the buckle beneath the eyelids indicated its removal in 34 (89.5%) eyes. Infection of the buckle and erosion of the conjunctiva with an exposed indentation were significantly more common with silicone buckles. Overall, scleral perforation occurred in four (4.4%) eyes, and retinal redetachment occurred in eight (8.8%) eyes. CONCLUSION: Late swelling of Miragel buckling elements represents a common indication for buckle removal, significantly different from silicone indentations.


Assuntos
Poli-Hidroxietil Metacrilato/análogos & derivados , Complicações Pós-Operatórias , Descolamento Retiniano/cirurgia , Recurvamento da Esclera/efeitos adversos , Elastômeros de Silicone , Adulto , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo , Feminino , Migração de Corpo Estranho/diagnóstico , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Estudos Retrospectivos
5.
J Biomed Mater Res A ; 67(1): 44-53, 2003 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-14517860

RESUMO

The biocompatibility of autocatalyzed poly(ortho ester) (POE(70)LA(30)), a viscous, hydrophobic, bioerodible polymer, was investigated. POE(70)LA(30) was synthesized, sterilized by gamma irradiation, and injected in rabbit eyes at adequate volumes through subconjunctival, intracameral, intravitreal, and suprachoroidal routes. Clinical examinations were performed postoperatively at regular time points for 6 mo, and histopathologic analysis was carried out to confirm tissular biocompatibility. After subconjunctival injection, the polymer was well tolerated and persisted in the subconjunctival space for about 5 weeks. In the case of intracameral injections, polymer biocompatibility was good; the POE(70)LA(30) bubble was still present in the anterior chamber for up to 6 mo after injection. No major histopathologic anomalies were detected, with the exception of a localized Descemet membrane thickening. After intravitreal administration, POE(70)LA(30) biocompatibility was excellent, and no inflammatory reaction could be detected during the observation period. The polymer was degraded in approximately 3 mo. Suprachoroidal injections of POE(70)LA(30) were reproducible and well tolerated. POE(70)LA(30) triggered a slight elevation of the retina and choroid upon clinical observation. The polymer was detectable in the suprachoroidal space for about 6 mo. No inflammatory reaction and no major retinal anomalies could be detected by histology. In conclusion, POE(70)LA(30) appears to be a promising biomaterial for intraocular application, potentially providing sustained drug delivery over an extended period of time, with a good tolerance.


Assuntos
Materiais Biocompatíveis/metabolismo , Olho/metabolismo , Polímeros/metabolismo , Animais , Materiais Biocompatíveis/efeitos adversos , Olho/patologia , Inflamação/metabolismo , Polímeros/efeitos adversos , Coelhos , Fatores de Tempo
6.
Invest Ophthalmol Vis Sci ; 43(5): 1533-9, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-11980871

RESUMO

PURPOSE: Drug delivery to treat diseases of the posterior segment of the eye, such as choroidal neovascularization and its complications, is hampered by poor intraocular penetration and rapid elimination of the drug from the eye. The purpose of this study was to investigate the feasibility and tolerance of suprachoroidal injections of poly(ortho ester) (POE), a bioerodible and biocompatible polymer, as a biomaterial potentially useful for development of sustained drug delivery systems. METHODS: After tunnelization of the sclera, different formulations based on POE were injected (100 microL) into the suprachoroidal space of pigmented rabbits and compared with 1% sodium hyaluronate. Follow-up consisted of fundus observations, echography, fluorescein angiography, and histologic analysis over 3 weeks. RESULTS: After injection, POE spread in the suprachoroidal space at the posterior pole. It was well tolerated and progressively disappeared from the site of injection without sequelae. No bleeding or retinal detachment occurred. Echographic pictures showed that the material was present in the suprachoroidal space for 3 weeks. Angiography revealed minor pigment irregularities at the site of injection, but no retinal edema or necrosis. Histology showed that POE was well tolerated in the choroid. CONCLUSIONS: POE suprachoroidal injections, an easy, controllable, and reproducible procedure, were well tolerated in the rabbit eye. POE appears to be a promising biomaterial to deliver drugs focally to the choroid and the retina.


Assuntos
Materiais Biocompatíveis/toxicidade , Corioide/efeitos dos fármacos , Sistemas de Liberação de Medicamentos , Polímeros/toxicidade , Animais , Corioide/diagnóstico por imagem , Corioide/patologia , Avaliação Pré-Clínica de Medicamentos , Espaço Extracelular/diagnóstico por imagem , Espaço Extracelular/efeitos dos fármacos , Estudos de Viabilidade , Feminino , Angiofluoresceinografia , Ácido Hialurônico/toxicidade , Injeções , Coelhos , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA