Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Circulation ; 149(9): 644-655, 2024 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-37883682

RESUMO

BACKGROUND: The optimal treatment in patients with severe aortic stenosis and small aortic annulus (SAA) remains to be determined. This study aimed to compare the hemodynamic and clinical outcomes between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with a SAA. METHODS: This prospective multicenter international randomized trial was performed in 15 university hospitals. Participants were 151 patients with severe aortic stenosis and SAA (mean diameter <23 mm) randomized (1:1) to TAVR (n=77) versus SAVR (n=74). The primary outcome was impaired valve hemodynamics (ie, severe prosthesis patient mismatch or moderate-severe aortic regurgitation) at 60 days as evaluated by Doppler echocardiography and analyzed in a central echocardiography core laboratory. Clinical events were secondary outcomes. RESULTS: The mean age of the participants was 75.5±5.1 years, with 140 (93%) women, a median Society of Thoracic Surgeons predicted risk of mortality of 2.50% (interquartile range, 1.67%-3.28%), and a median annulus diameter of 21.1 mm (interquartile range, 20.4-22.0 mm). There were no differences between groups in the rate of severe prosthesis patient mismatch (TAVR, 4 [5.6%]; SAVR, 7 [10.3%]; P=0.30) and moderate-severe aortic regurgitation (none in both groups). No differences were found between groups in mortality rate (TAVR, 1 [1.3%]; SAVR, 1 [1.4%]; P=1.00) and stroke (TAVR, 0; SAVR, 2 [2.7%]; P=0.24) at 30 days. After a median follow-up of 2 (interquartile range, 1-4) years, there were no differences between groups in mortality rate (TAVR, 7 [9.1%]; SAVR, 6 [8.1%]; P=0.89), stroke (TAVR, 3 [3.9%]; SAVR, 3 [4.1%]; P=0.95), and cardiac hospitalization (TAVR, 15 [19.5%]; SAVR, 15 [20.3%]; P=0.80). CONCLUSIONS: In patients with severe aortic stenosis and SAA (women in the majority), there was no evidence of superiority of contemporary TAVR versus SAVR in valve hemodynamic results. After a median follow-up of 2 years, there were no differences in clinical outcomes between groups. These findings suggest that the 2 therapies represent a valid alternative for treating patients with severe aortic stenosis and SAA, and treatment selection should likely be individualized according to baseline characteristics, additional anatomical risk factors, and patient preference. However, the results of this study should be interpreted with caution because of the limited sample size leading to an underpowered study, and need to be confirmed in future larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03383445.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Acidente Vascular Cerebral/etiologia
2.
BMC Cardiovasc Disord ; 23(1): 176, 2023 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-37003986

RESUMO

BACKGROUND: A decade ago, the iopromide-paclitaxel coated balloon (iPCB) was added to the cardiologist's toolbox to initially treat in-stent restenosis followed by the treatment of de novo coronary lesions. In the meantime, DES technologies have been substantially improved to address in-stent restenosis and thrombosis, and shortened anti-platelet therapy. Recently, sirolimus-coated balloon catheters (SCB) have emerged to provide an alternative drug to combat restenosis. METHODS: The objective of this study is to determine the safety and efficacy of a novel crystalline sirolimus-coated balloon (cSCB) technology in an unselective, international, large-scale patient population. Percutaneous coronary interventions of native stenosis, in-stent stenosis, and chronic total occlusions with the SCB in patients with stable coronary artery disease or acute coronary syndrome were included. The primary outcome variable is the target lesion failure (TLF) rate at 12 months, defined as the composite rate of target vessel myocardial infarction (TV-MI), cardiac death or ischemia-driven target lesion revascularization (TLR). The secondary outcome variables include TLF at 24 months, ischemia driven TLR at 12 and 24 months and all-cause death, cardiac death at 12 and 24 months. DISCUSSION: Since there is a wealth of patient-based all-comers data for iPCB available for this study, a propensity-score matched analysis is planned to compare cSCB and iPCB for the treatment of de novo and different types of ISR. In addition, pre-specified analyses in challenging lesion subsets such as chronic total occlusions will provide evidence whether the two balloon coating technologies differ in their clinical benefit for the patient. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Identifier: NCT04470934.


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Humanos , Angioplastia/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Constrição Patológica/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Stents Farmacológicos/efeitos adversos , Paclitaxel/efeitos adversos , Sirolimo/efeitos adversos , Resultado do Tratamento , Ensaios Clínicos como Assunto
3.
Cardiovasc Revasc Med ; 52: 10-15, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36822976

RESUMO

INTRODUCTION AND OBJECTIVE: At least one in ten patients infected with COVID develop cardiovascular complications during hospitalization, increasing the number of deaths from this cause. However, the determinants of risk are not clearly elucidated. This study aims to determine whether there is a relationship between in-hospital cardiac complications and cardiovascular history and hospital evolution. METHODS: Prospective cohort study of 373 patients with a positive diagnosis of SARS-CoV-2 admitted to an Intensive Care Unit between March and October 2021. RESULTS: Median age was 69 (IQR: 57-77), 29.2 % of patients presented cardiovascular complications: 21.2 % electrical, 5.9 % acute coronary syndrome and 1.9 % pulmonary thromboembolism. Age RR: 1.02 (95 % CI: 1.00-1.04; p = 0.020) and history of ischemic heart disease RR: 2.23 (95 % CI: 1.27-3.92; p = 0.005) were identified as independent predictors of in-hospital cardiac complications. CONCLUSIONS: Age and history of ischemic heart disease were identified as independent predictor variables of cardiovascular complications in patients admitted with severe COVID-19 involvement; being significantly associated with lower survival.


Assuntos
COVID-19 , Cardiopatias , Isquemia Miocárdica , Humanos , Idoso , COVID-19/complicações , COVID-19/diagnóstico , SARS-CoV-2 , Estudos de Coortes , Estudos Prospectivos , Cuba/epidemiologia , Hospitalização , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/epidemiologia , Fatores de Risco , Mortalidade Hospitalar
4.
Int J Cardiol ; 362: 128-136, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35550389

RESUMO

BACKGROUND: High degree cardiac conduction disturbances (HDCD) remain a major complication after transcatheter aortic valve replacement (TAVR), especially with self-expandable valves (SEV). Our aim was to investigate peri-procedural and in-hospital modification of atrioventricular and intracardiac conduction associated to new generation SEV implantation, and the development of new HDCD resulting in permanent pacemaker implantation (PPM) in patients undergoing TAVR. METHODS AND RESULTS: Three-hundred forty-four consecutive patients with severe aortic stenosis who underwent TAVR with a new generation SEV [Evolut-R/Pro (n = 130), Acurate-neo (n = 79), Portico (n = 75) and Allegra (n = 60)] were included. An analysis of baseline, post-TAVR and pre-discharge ECG and procedural aspects were centrally performed. A significant increase in baseline PR interval (169.6 ± 28.2 ms) and QRS complex width (101.7 ± 25.9 ms) was noted immediately post-TAVR (188.04 ± 34.49; 129.55 ± 30.02 ms), with a partial in-hospital reversal (179.4 ± 30.1; 123.06 ± 30.94 ms), resulting in a net increase at hospital discharge of 12.6 ± 38.8 ms and 21.4 ± 31.6 ms (p < 0.001), respectively. The global incidence of new onset persistent HDCD at hospital discharge was 46.3%, with 17.7% of patients requiring PPM. Independent predictors of new onset HCDC at hospital discharge were valve recapture (OR: 2.8; 95% IC: 1.1-7.2, p = 0.033) and implantation depth ≥ 6 mm (OR: 1.9 05% IC 1.1-3.3, p = 0.015), while higher implantation (<3 mm (OR: 0.3, 95% IC 0.1-0.7, p = 0.014) and use of Acurate-Neo valve (OR: 0.4; 95% IC 0.2-0.8, p = 0.009) were protective factor. CONCLUSIONS: New generation self-expanding aortic valves were associated with a significant increase in PR and QRS interval at hospital discharge leading to a very high rate of HDCD. While valve recapture and implantation depth were independent predictors for the occurrence of HDCD, use of Accurate-Neo valve was a protective factor.


Assuntos
Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Doença do Sistema de Condução Cardíaco/diagnóstico , Doença do Sistema de Condução Cardíaco/epidemiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Am Heart J ; 246: 32-43, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34990582

RESUMO

BACKGROUND: Current ESC guidelines recommend the use of intra-coronary pressure guidewires for functional assessment of intermediate-grade coronary stenoses. Angiography-derived quantitative flow ratio (QFR) is a novel method of assessing these stenoses, and guiding percutaneous coronary intervention (PCI). METHODS/DESIGN: The PIONEER IV trial is a prospective, all-comers, multi-center trial, which will randomize 2,540 patients in a 1:1 ratio to PCI guided by angiography-derived physiology or usual care, with unrestricted use in both arms of the Healing-Targeted Supreme sirolimus-eluting stent (HT Supreme). The stent's fast, biologically healthy, and robust endothelial coverage allows for short dual-antiplatelet therapy (DAPT); hence the antiplatelet regimen of choice is 1-month DAPT, followed by ticagrelor monotherapy. In the angiography-derived physiology guided arm, lesions will be functionally assessed using on-line QFR, with stenting indicated in lesions with a QFR ≤0.80. Post-stenting, QFR will be repeated in the stented vessel(s), with post-dilatation or additional stenting recommended if the QFR<0.91 distal to the stent, or if the delta QFR (across the stent) is >0.05. Usual care PCI is performed according to standard clinical practice. The primary endpoint is a non-inferiority comparison of the patient-oriented composite endpoint (POCE) of all-cause death, any stroke, any myocardial infarction, or any clinically, and physiologically driven revascularization with a non-inferiority risk-difference margin of 3.2%, at 1-year post-procedure. Clinical follow-up will be up to 3 years. SUMMARY: The PIONEER IV trial aims to demonstrate non-inferiority of QFR-guided PCI to usual care PCI with respect to POCE at 1-year in patients treated with HT Supreme stents and ticagrelor monotherapy. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov UNIQUE IDENTIFIER: NCT04923191 CLASSIFICATIONS: Interventional Cardiology.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Humanos , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Stents , Ticagrelor/uso terapêutico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...