Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Talanta ; 271: 125676, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38266436

RESUMO

Cinnamon is one of the most popular spices used in cuisines worldwide. Among its different species, Ceylon cinnamon ("true cinnamon") is the one with the most health benefits due to its high concentration in the antioxidant eugenol and the ultra-low content of the hepatotoxic compound coumarin. However, the higher price of Ceylon cinnamon makes it vulnerable to fraudulent adulteration with more economic species of cinnamon, such as Cassia and Saigon. Thus, for the detection of frauds in cinnamon samples, a HPLC-UV method was developed for the determination of 4 characteristic cinnamon compounds: eugenol, cinnamaldehyde, coumarin and cinnamic acid. The obtained data were analyzed by PLS to attain not only the authentication of cinnamon species but also the detection and quantification of partial adulterations. Several mixtures prepared in the laboratory using different cinnamon powder samples considered 'pure' Ceylon, Cassia or Saigon were tested, concluding that the proposed approach allows a clear identification of Ceylon cinnamon and a suitable quantification of the Ceylon: non-Ceylon ratio regardless of the commercial sample selected (RMSE <0.06 for both training and test sets).


Assuntos
Cinnamomum zeylanicum , Eugenol , Cromatografia Líquida de Alta Pressão/métodos , Quimiometria , Cumarínicos/análise
2.
Talanta ; 241: 123273, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35123245

RESUMO

A hybrid sensing system, which combines simultaneous cyclic voltammetric (CV) and UV-vis absorbance measurements using a commercial carbon screen-printed electrode and a set of optical fibres in disposable cuvettes, is proposed. The hybrid system approach was applied to 27 samples of recognized beer brands, improving the classification power as compared to only voltammetric or only spectrophotometric measurements. The developed partial least squares discriminant analysis (PLS-DA) model was able to discriminate between five types of beer (lager, marzen, black/stout, alcohol-free and white/ale). The model was also successfully applied to 28 beer samples of white-label brands sold in local supermarkets, demonstrating their similarity to recognized brand beers.


Assuntos
Cerveja , Etanol , Cerveja/análise , Análise Discriminante , Eletrodos , Etanol/análise , Análise dos Mínimos Quadrados
3.
Talanta ; 238(Pt 2): 123036, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34801894

RESUMO

The exceptional properties of 2D layered black phosphorus (BP) make it a promising candidate for electrochemical sensing applications and, even though BP is considered unstable and tends to degrade by the presence of oxygen and moisture, its oxidation can be beneficial in some situations. In this work, we present an unequivocal demonstration that the exposition of BP-based working electrodes to normal ambient conditions can indeed be advantageous, leading to an enhancement of voltammetric sensing applications. This point was proved using a BP modified screen-printed carbon electrode (BP-SPCE) for the voltammetric determination of dopamine (DA) as a model target analyte. Oxidized BP-SPCE (up to 35% of PxOy at the surface) presented an enhanced analytical performance with a 5-fold and 2-fold increase in sensitivity, as compared to bare-SPCE and non-oxidized BP-SPCE stored in anhydrous atmosphere, respectively. Good detection limit, repeatability, reproducibility, stability, selectivity, and accuracy were also achieved. Overall, the results presented herein display the prominent possibilities of preparing and working with BP based-sensors in normal ambient settings and showcase their implementation under physiological conditions.


Assuntos
Técnicas Eletroquímicas , Fósforo , Carbono , Eletrodos , Reprodutibilidade dos Testes
4.
Anal Chim Acta ; 1188: 339166, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34794577

RESUMO

In this paper, a vibrating boron-doped diamond (BDD) electrode electroanalytical device and respective method for the analysis of ultralow concentrations of Cd(II) in water were studied. The enhanced mass transfer on the electrode surface was studied using Ru(NH3)6Cl3. Vibration with 133 Hz frequency enhanced the Ru(III) to Ru(II) reduction by 92.6% compared to a static electrode. The peak current of the anodic stripping voltammetry (ASV) method employed was increased by a factor of 5.3 and 4.7 for 10 and 30 µg L-1 Cd(II) concentrations, respectively, when a frequency of 200 Hz was used. A calibration plot with two linear regions was resolved between 0.01 and 1 µg L-1 and 1-30 µg L-1 with the LOD and LOQ of 0.04 µg L-1 and 0.12 µg L-1, respectively. The applicability of the device and the respective method in the analysis of real environmental samples was successfully verified by analysis of river samples and comparing the results with the ICP analysis presenting high reproducibility and trueness. According to the results of this research, the vibrating BDD electrode with the ASV method has excellent analytical performance without surface modification or regular replacement or polishing of the electrode surface. Combining the exceptional electrochemical and chemical properties of BDD with enhanced mass transfer and signal strength of vibrating electrodes makes the system especially suitable for on-site and online analysis of heavy metals.


Assuntos
Boro , Metais Pesados , Cádmio , Eletrodos , Reprodutibilidade dos Testes
5.
J Solid State Electrochem ; 24(11-12): 2653-2661, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32837295

RESUMO

A personal mini-review is presented on the history of electroanalysis and on their present achievements and future challenges. The manuscript is written from the subjective view of two generations of electroanalytical chemists that have witnessed for many years the evolution of this discipline.

6.
Sensors (Basel) ; 20(7)2020 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-32224938

RESUMO

Benzotriazoles (BZTs) are high production volume industrial chemicals that are used in various applications such as corrosion inhibitors, antifreeze agents, and UV radiation stabilizers. Given their potential ecotoxicological implications for different ecosystems and in human health, as well as their poor biodegradability, they are of increasing concern. In this study, a new voltammetric method using commercial screen-printed electrodes (SPEs) has been developed for the sensing of BZTs in water samples to help in their environmental monitoring. To this end, different types of SPEs based on carbon nanoallotropes and copper were tested under several experimental conditions to determine the two BZTs most frequently detected in the environment: 1H-benzotriazole (BZT) and 5-methyl-1H-benzotriazole (Me-BZT, tolyltriazole) as model compounds for BZTs. Carbon nanofibers electrodes exhibited the best performance, allowing detection limits as low as 0.4 mg L-1 for both BZTs, with repeatability and reproducibility of ca. 5%. The applicability of the method was tested through the determination of BZT in spiked drinking water samples, suggesting its suitability for the sensing of samples heavily polluted with BZTs.

7.
Chem Phys Lipids ; 229: 104895, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32165169

RESUMO

In this work, a novel molecularly imprinted electrochemical sensor (MIES) has been fabricated based on electropolymerization of a molecularly imprinted polymer (MIP) onto a glassy carbon electrode (GCE) modified with gold-palladium alloy nanoparticles (AuPd NPs)/polydopamine film (PDA)/multiwalled carbon nanotubes-chitosan-ionic liquid (MWCNTs-CS-IL) for voltammetric and impedimetric determination of cholestanol (CHO). Modifications applied to the bare GCE formed an excellent biocompatible composite film which was able to selectively detect CHO molecules. Modifications applied to the bare GCE were characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (SEM). Under optimal experimental conditions, the sensor was able to detect CHO in the range of 0.1-60 pM and 1-50 pM by EIS and DPV, respectively. Moreover, the sensor showed high sensitivity, selectivity, repeatability, reproducibility, low interference and good stability towards CHO determination. Our records confirmed that the sensor was successfully able to the analysis real samples for determination of CHO.


Assuntos
Colestanol/análise , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Impressão Molecular , Técnicas Biossensoriais , Limite de Detecção
8.
Anal Chem ; 92(4): 3396-3402, 2020 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-31951120

RESUMO

A multivariate version of the classical univariate standard addition method is proposed for the analysis of samples generating overlapping signals in the presence of notorious matrix effects. Unlike previous versions based on multivariate calibration by partial least-squares (PLS), the proposed strategy takes advantage of a self-modeling methodology: multivariate curve resolution by alternating least-squares (MCR-ALS) enhanced with signal shape constraints based on parametric functions. In this way, there is no need for the full multivariate response of a blank solution, and in multianalyte determinations, the standard additions can be made with a solution containing all of the analytes, which constitutes a clear advance as compared to PLS approach. The proposed method has been successfully tested in the voltammetric determination of hydroquinone and catechol in solutions of increasing complexity and appears to be a promising tool in the field of electroanalysis.

9.
Sensors (Basel) ; 19(19)2019 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-31575062

RESUMO

A critical revision is made on recent applications of voltammetric electronic tongues in the field of food analysis. Relevant works are discussed dealing with the discrimination of food samples of different type, origin, age and quality and with the prediction of the concentration of key substances and significant indexes related to food quality.

10.
Sensors (Basel) ; 19(18)2019 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-31546788

RESUMO

Carbon screen-printed electrode (SPCE), multi-walled carbon nanotubes modified screen-printed electrode (SPCNTE), carbon nanofibers modified screen-printed electrode (SPCNFE), and graphene modified screen-printed electrode (SPGPHE) were in a pioneer way tested as sensors for the simultaneous determination of the two most consumed pain-killers, paracetamol (PA) and ibuprofen (IB), and the stimulant caffeine (CF) in water by differential pulse voltammetry (DPV). Their analytical performances were compared, and the resulting sensitivities (2.50, 0.074, and 0.24 µA V mg-1 L for PA, IB, and CF, respectively), detection limits (0.03, 0.6, and 0.05 mg L-1 for PA, IB, and CF, respectively) and quantification limits (0.09, 2.2, and 0.2 mg L-1 for PA, IB, and CF, respectively) suggested that the SPCNFE was the most suitable carbon-based electrode for the voltammetric determination of the selected analytes in water at trace levels. The methodology was validated using both spiked tap water and hospital wastewater samples. The results were compared to those achieved by liquid chromatography-tandem mass spectrometry (LC-MS/MS), the technique of choice for the determination of the target analytes.


Assuntos
Acetaminofen/análise , Cafeína/análise , Eletroquímica/instrumentação , Eletrodos , Ibuprofeno/análise , Eletroquímica/métodos , Limite de Detecção , Nanoestruturas/química , Nanotubos de Carbono/química , Reprodutibilidade dos Testes , Águas Residuárias/análise , Poluentes Químicos da Água/análise
11.
Talanta ; 201: 104-110, 2019 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-31122399

RESUMO

A simple HPLC-EC method based on hydrophilic interaction liquid chromatography with amperometric detection through gold screen-printed electrodes has been developed and applied for the first time to the determination of aminothiols in white wines. Moreover, the coupling of the method with partial least squares discriminant analysis (PLS-DA) using the analysed aminothiols as biomarkers provides wine discrimination in terms of harvest year. White wine samples were directly injected and chromatographic areas, together with pH and redox potential values, allowed a successful discrimination of wines from different harvest years with a global classification rate of 97.8%. The developed HPLC-EC method also generated characteristic fingerprints that were combined with PLS-DA to classify wines according to three wine varieties, with a global classification rate of 95.3%.

12.
Talanta ; 196: 381-388, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30683380

RESUMO

A new voltammetric methodology is proposed for the simultaneous determination of the organic UV filters oxybenzone (benzophenone 3, BP3) and octocrylene (OC) in personal care products and in wastewater extracts. It is based on previous adsorptive stripping voltammetric (AdSV) methods developed for hanging mercury drop electrodes, adapted to the special characteristics of carbon-based screen-printed electrodes. Among the carbon substrates tested, regular carbon screen-printed devices exhibited the best performance, with detection limits of 4.8 and 6.6 µmol L-1 and linearity ranges of 16-400 and 22-400 µmol L-1 for BP3 and OC, respectively, and, as compared to mercury electrodes, with the advantages of environmental safety, easy of use, low cost and compatibility with automation and flow measurements. The methodology has been successfully tested in real samples and compared to the standard methodology by liquid chromatography - tandem mass spectrometry (LC-MS/MS).

13.
Talanta ; 192: 147-153, 2019 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-30348371

RESUMO

A new multivariate standard addition strategy applicable to stripping methods was proposed as an extention of the classical univariate standard addition method for the resolution of complex samples involving overlapped peaks and complex matrices. The proposed strategy consists in alternate additions of the considered analytes and the further extrapolation to a simulated blank solution measured by skipping the preconcentration step (deposition time = 0). This calibration approach was successfully tested in tonic water samples spiked with Tl(I) and In(III) using a sensor array based on a SeCyst-SPCNFE and an ex-situ-BiSPCE, providing good concordance between replicates and much better accuracy than the usual multivariate external calibration method.

14.
Sensors (Basel) ; 18(12)2018 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-30567367

RESUMO

The development of a simple HPLC-UV method towards the evaluation of Spanish paprika's phenolic profile and their discrimination based on the former is reported herein. The approach is based on C18 reversed-phase chromatography to generate characteristic fingerprints, in combination with linear discriminant analysis (LDA) to achieve their classification. To this aim, chromatographic conditions were optimized so as to achieve the separation of major phenolic compounds already identified in paprika. Paprika samples were subjected to a sample extraction stage by sonication and centrifugation; extracting procedure and conditions were optimized to maximize the generation of enough discriminant fingerprints. Finally, chromatograms were baseline corrected, compressed employing fast Fourier transform (FFT), and then analyzed by means of principal component analysis (PCA) and LDA to carry out the classification of paprika samples. Under the developed procedure, a total of 96 paprika samples were analyzed, achieving a classification rate of 100% for the test subset (n = 25).


Assuntos
Capsicum/química , Cromatografia Líquida de Alta Pressão/métodos , Análise Discriminante , Fenóis/análise , Extratos Vegetais/química , Análise de Componente Principal , Padrões de Referência
15.
Talanta ; 189: 296-301, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30086921

RESUMO

Screen-printed electrodes based on graphite, carbon nanotubes, carbon nanofibers, and graphene were tested as amperometric detectors for the determination of phenolic compounds by high performance liquid chromatography (HPLC). The chromatographic performance as well as the obtained sensitivity, detection and quantification limits suggest that carbon nanofibers modified screen-printed electrode (SPCE-CNF) is the amperometric sensor that provides the best analytical performance. Upon this confirmation, chromatographic data obtained using SPCE-CNF were exploited by means of linear discriminant analysis (LDA) to successfully characterize and classify 96 Spanish paprika (Capsicum annuum L.) samples with different origin and type: from La Vera (including sweet, bittersweet and spicy types) and from Murcia (including sweet and spicy types).

16.
Anal Chim Acta ; 990: 11-53, 2017 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-29029733

RESUMO

For a long time mercury electrodes have been the main choice for the analysis of metal ions and some metalloids. However, in the last years, safety and environmental considerations have restricted their use and encouraged the search for alternative materials more environmentally friendly and with more possibilities for in-situ and flow analysis. This research has been reinforced by the popularisation of nanomaterials, biomolecules and screen-printed electrodes, as well as for the new advances in sensor miniaturization and integration of the electrodes in multi-sensor platforms and electronic tongues. The present review critically summarizes and discusses the progress made since 2010 in the development and application of new electrodes for the analysis of metals and metalloids.

17.
Talanta ; 175: 501-506, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28842024

RESUMO

A novel selenium based screen-printed electrode was developed based on the immobilization of selenocystine on aryl diazonium salt monolayers anchored to a carbon-nanofiber screen-printed electrode support (SeCyst-SPCNFE). SeCyst-SPCNFE was analytically compared to a screen-printed carbon nanofiber electrode modified with L-Cystine (Cyst-SPCNFE) for the determination of Pb(II) and Cd(II) by stripping voltammetric techniques. Their analytical performance suggests that SeCyst-SPCNFE could be a much better alternative for metal ion determination at trace levels than Cyst-SPCNFE. The proposed electrode was successfully applied for the simultaneous voltammetric determination of trace Pb(II) and Cd(II) in a wastewater reference material with a very high reproducibility (3.2%) and good trueness (2.6%).

18.
Sensors (Basel) ; 17(6)2017 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-28635631

RESUMO

A new silver nanoparticle modified screen-printed electrode was developed and applied to the simultaneous determination of Pb(II) and Cu(II). Two different types of silver nanoparticles with different shapes and sizes, Ag nanoseeds and Ag nanoprisms, were microscopically characterized and three different carbon substrates, graphite, graphene and carbon nanofibers, were tested. The best analytical performance was achieved for the combination of Ag nanoseeds with a carbon nanofiber modified screen-printed electrode. The resulting sensor allowed the simultaneous determination of Pb(II) and Cu(II) at trace levels and its applicability to natural samples was successfully tested with a groundwater certified reference material, presenting high reproducibility and trueness.

19.
Chemosphere ; 176: 74-80, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28259081

RESUMO

The effects of mercury (Hg) released from a chlor-alkali factory in aquatic plants along the Ebro River basin (NE Spain) were analysed considering the phytochelatins (PCn) and their isoforms content in these plants. These compounds were analyzed using HPLC with amperometric detection, and the macrophytes species Ceratophyllum demersum and Myriopyllum spicatum were collected in two sampling campaigns, autumn and spring, respectively. To correlate the PCn content in macrophytes with the Hg contamination, analysis of total Hg (THg) content in plants and suspended particulate matter, as well as the dissolved-bioavailable fraction of Hg in water measured by the diffusive gradient in thin film (DGT) technique were done. The results confirm the presence of PC2-Ala in extracts of C. demersum and PC2-desGly in M. spicatum, and the concentration of these thiol compounds depends clearly on the distance between the hot spot and the downstream sites: the higher the levels are, the closer the hot spot is. Since most of the Hg is hypothesized to be associated with SPM and transported downstream, our results of the DGT suggest that trace amounts of Hg in water can be released as free metal ions yielding a certain accumulation in plants (reaching the ppb level) that are enough for activation of induction of PCs. A few PCs species have been determined, at different seasons, indicating that they can be used as good indicators of the presence of bioavailable Hg in aquatic media throughout the year.


Assuntos
Álcalis/análise , Magnoliopsida/metabolismo , Mercúrio/análise , Fitoquelatinas/biossíntese , Rios/química , Poluentes Químicos da Água/análise , Sedimentos Geológicos/química , Magnoliopsida/crescimento & desenvolvimento , Espanha
20.
Talanta ; 167: 1-7, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28340698

RESUMO

The use of an antimony film coated on a screen-printed carbon electrode (ex-situ SbSPCE) is proposed for the determination of Pd(II) at ppb levels in natural samples by adsorptive stripping voltammetry using dimethylglyoxime as chelating agent. Ex-situ SbSPCE produces a better analytical performance as compared to a commercially sputtered bismuth screen-printed electrode (BispSPE). The detection and quantification limits were 2.7 and 9.0µgL-1 respectively with a good linear behaviour in the wide examined concentration range (from 1µgL-1 up to 100.0µgL-1, R2=0.998). The proposed ex-situ SbSPCE showed an excellent repeatability with a relative standard deviation of 0.5% for ten successive measurements and a very good reproducibility (1.6% for three different ex-situ SbSPCE units within series of ten repetitive assays). Moreover, the ex-situ SbSPCE was successfully applied for the determination of low concentration levels of Pd(II) in spiked tap water with a very high reproducibility (0.2%) and providing equivalent results to those achieved by ICP-MS measurements.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA