Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Radiat Res ; 199(6): 535-555, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37310880

RESUMO

Tools for radiation exposure reconstruction are required to support the medical management of radiation victims in radiological or nuclear incidents. Different biological and physical dosimetry assays can be used for various exposure scenarios to estimate the dose of ionizing radiation a person has absorbed. Regular validation of the techniques through inter-laboratory comparisons (ILC) is essential to guarantee high quality results. In the current RENEB inter-laboratory comparison, the performance quality of established cytogenetic assays [dicentric chromosome assay (DCA), cytokinesis-block micronucleus assay (CBMN), stable chromosomal translocation assay (FISH) and premature chromosome condensation assay (PCC)] was tested in comparison to molecular biological assays [gamma-H2AX foci (gH2AX), gene expression (GE)] and physical dosimetry-based assays [electron paramagnetic resonance (EPR), optically or thermally stimulated luminescence (LUM)]. Three blinded coded samples (e.g., blood, enamel or mobiles) were exposed to 0, 1.2 or 3.5 Gy X-ray reference doses (240 kVp, 1 Gy/min). These doses roughly correspond to clinically relevant groups of unexposed to low exposed (0-1 Gy), moderately exposed (1-2 Gy, no severe acute health effects expected) and highly exposed individuals (>2 Gy, requiring early intensive medical care). In the frame of the current RENEB inter-laboratory comparison, samples were sent to 86 specialized teams in 46 organizations from 27 nations for dose estimation and identification of three clinically relevant groups. The time for sending early crude reports and more precise reports was documented for each laboratory and assay where possible. The quality of dose estimates was analyzed with three different levels of granularity, 1. by calculating the frequency of correctly reported clinically relevant dose categories, 2. by determining the number of dose estimates within the uncertainty intervals recommended for triage dosimetry (±0.5 Gy or ±1.0 Gy for doses <2.5 Gy or >2.5 Gy), and 3. by calculating the absolute difference (AD) of estimated doses relative to the reference doses. In total, 554 dose estimates were submitted within the 6-week period given before the exercise was closed. For samples processed with the highest priority, earliest dose estimates/categories were reported within 5-10 h of receipt for GE, gH2AX, LUM, EPR, 2-3 days for DCA, CBMN and within 6-7 days for the FISH assay. For the unirradiated control sample, the categorization in the correct clinically relevant group (0-1 Gy) as well as the allocation to the triage uncertainty interval was, with the exception of a few outliers, successfully performed for all assays. For the 3.5 Gy sample the percentage of correct classifications to the clinically relevant group (≥2 Gy) was between 89-100% for all assays, with the exception of gH2AX. For the 1.2 Gy sample, an exact allocation to the clinically relevant group was more difficult and 0-50% or 0-48% of the estimates were wrongly classified into the lowest or highest dose categories, respectively. For the irradiated samples, the correct allocation to the triage uncertainty intervals varied considerably between assays for the 1.2 Gy (29-76%) and 3.5 Gy (17-100%) samples. While a systematic shift towards higher doses was observed for the cytogenetic-based assays, extreme outliers exceeding the reference doses 2-6 fold were observed for EPR, FISH and GE assays. These outliers were related to a particular material examined (tooth enamel for EPR assay, reported as kerma in enamel, but when converted into the proper quantity, i.e. to kerma in air, expected dose estimates could be recalculated in most cases), the level of experience of the teams (FISH) and methodological uncertainties (GE). This was the first RENEB ILC where everything, from blood sampling to irradiation and shipment of the samples, was organized and realized at the same institution, for several biological and physical retrospective dosimetry assays. Almost all assays appeared comparably applicable for the identification of unexposed and highly exposed individuals and the allocation of medical relevant groups, with the latter requiring medical support for the acute radiation scenario simulated in this exercise. However, extreme outliers or a systematic shift of dose estimates have been observed for some assays. Possible reasons will be discussed in the assay specific papers of this special issue. In summary, this ILC clearly demonstrates the need to conduct regular exercises to identify research needs, but also to identify technical problems and to optimize the design of future ILCs.


Assuntos
Bioensaio , Coleta de Amostras Sanguíneas , Estudos Retrospectivos , Citocinese , Espectroscopia de Ressonância de Spin Eletrônica
2.
Radiat Res ; 176(6): 821-6, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21823974

RESUMO

In this study we analyzed the ESR signal of alanine dosimeters with gadolinium exposed to 6 MV linear accelerator photons. We observed that the addition of gadolinium brings about an improvement in the sensitivity to photons because of its high atomic number. The experimental data indicated that the addition of gadolinium increases the sensitivity of the alanine to 6 MV photons. This enhancement was better observed at high gadolinium concentrations for which the tissue equivalence is heavily reduced. However, information about the irradiation setup and of the radiation beam features allows one to correct for this difference. Monte Carlo simulations were carried out to obtain information on the expected effect of the addition of gadolinium on the dose absorbed by the alanine molecules inside the pellets. These results are compared with the experimental values, and the agreement is discussed.


Assuntos
Alanina/química , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Gadolínio/química , Fótons , Radiometria/métodos , Aceleração , Relação Dose-Resposta à Radiação , Modelos Lineares , Método de Monte Carlo , Raios X
3.
Appl Radiat Isot ; 68(4-5): 639-42, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19819712

RESUMO

The thermoluminescence technique is recommended by the European Committee for Standardization for the detection of irradiated food containing silicates as contaminants. In this work, the applicability of the thermoluminescence technique as a quantitative method to assess the original dose in irradiated oregano was studied; the additive-dose method was used, with reirradiation doses up to 600 Gy. The proposed new procedure allows to clearly discriminate irradiated from unirradiated samples, even after one year storage, and it gives an acceptable estimation of the original dose; the overall modified procedure requires only one day to be completed.


Assuntos
Análise de Alimentos/métodos , Contaminação Radioativa de Alimentos/análise , Especiarias/análise , Especiarias/efeitos da radiação , Dosimetria Termoluminescente/métodos , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Phys Med Biol ; 52(17): 5219-30, 2007 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-17762082

RESUMO

In this paper, the addition of gadolinium is proposed as a useful tool to enhance the electron spin resonance (ESR) sensitivity of organic compounds to thermal neutrons. The target of this work is the detection, through the ESR technique, of the thermal neutron fluence in a mixed field of photons and neutrons. Gadolinium was chosen because it has a very high capture cross section to thermal neutrons; its nuclear reaction with thermal neutrons induces complex inner shell transitions that generate, besides other particles, Auger electrons, which in turn release their energy in the neighborhood (only several nanometers) of the place of reaction. Gadolinium was added to two organic molecules: alanine and ammonium tartrate. The main result obtained was a greater neutron sensitivity for dosimeters with gadolinium than for those without gadolinium for both organic molecules used. Since a dosimeter pair is required to discriminate between the two components of a mixed field, we studied the response of each dosimeter pair irradiated in a mixed field. Through a blind test we verified the usefulness of this dosimetric system and we obtained an estimate of the fluence in the mixed field with a relative uncertainty of 3%, when the pair composed of an alanine dosimeter and a dosimeter with alanine and gadolinium is used.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Gadolínio/química , Gadolínio/efeitos da radiação , Radiometria/métodos , Temperatura Alta , Nêutrons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Radiat Prot Dosimetry ; 126(1-4): 631-5, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17517673

RESUMO

In this paper, the results of a study on the electron spin resonance (ESR) dosimetry to measure thermal neutron fluence in a mixed radiation field (neutron and photons) are presented. The ESR responses of alanine dosemeters with different additives are compared. In particular, the (10)B-acid boric and the Gd-oxide were chosen to enhance the sensitivity of alanine dosemeters to thermal neutrons. Irradiations were carried out inside the thermal column of the TAPIRO reactor of the ENEA center, Casaccia Rome. The main results are a greater neutron sensitivity and a smaller lowest detectable fluence for the dosemeters with gadolinium than for dosemeters of alanine with (10)B, which is well known to be much more sensitive to thermal neutrons than simple alanine.


Assuntos
Alanina/química , Alanina/efeitos da radiação , Espectroscopia de Ressonância de Spin Eletrônica/instrumentação , Nêutrons , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Calibragem , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Appl Radiat Isot ; 65(4): 435-9, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17158056

RESUMO

ESR response to gamma-irradiation (1-50 Gy) of blends containing alanine and either B(OH)(3) or Gd(2)O(3) is reported. The sensitivity of the alanine--B(OH)(3) blend is comparable to the sensitivity of pure alanine, although its lowest detectable dose, LDD, is smaller ( approximately 1.3 Gy) than that of pure alanine ( approximately 2.9 Gy). Alanine with Gd(2)O(3) is about two times more sensitive than pure alanine, and its LDD is 0.8 Gy. The better sensitivity and LDD are probably due to the high atomic number (Z=64) of gadolinium, which enhances the interaction probability with photons and, consequently, the radical yield. This study suggests that other high-Z atoms may be useful for increasing the sensitivity of the response of alanine to gamma-radiation.


Assuntos
Alanina/efeitos da radiação , Ácidos Bóricos/efeitos da radiação , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Raios gama , Radiometria/métodos , Boro , Gadolínio/efeitos da radiação , Isótopos
7.
Eur J Pharm Biopharm ; 59(1): 139-46, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15567311

RESUMO

Ionizing radiation can be used as a drug sterilization technique, provided that the drug itself is not modified and that no toxic products are produced; moreover, if the irradiated product is a drug delivery system, the drug release characteristics must not be significantly altered by radiation. The aim of this work was to study the effects of sterilization by ionizing radiation on hydroxyethylcellulose/trehalose spherical micromatrices, containing the antibiotic vancomycin. Our experimental results showed that gamma-rays did not alter the chromophore groups of vancomycin (UV measurements), and did not modify the kinetic behavior of drug release from microspheres. Moreover, no significant changes in the shape and in the size distribution of microspheres were found after irradiation. The electron spin resonance (ESR) spectroscopy was proven to be a valid identification method of the executed radiation treatment, even after 5 years. The experimental results showed that the therapeutic application of the pharmacological system investigated was not compromised by irradiation, and that ESR spectroscopy can be used to distinguish irradiated from non-irradiated products.


Assuntos
Celulose/análogos & derivados , Celulose/efeitos da radiação , Raios gama , Microesferas , Trealose/efeitos da radiação , Vancomicina/efeitos da radiação , Celulose/química , Trealose/química , Vancomicina/química
8.
Radiat Prot Dosimetry ; 110(1-4): 627-30, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15353720

RESUMO

The dosimetric technique described in this paper is based on electron spin resonance (ESR) detectors using an alanine-boric compound acid enriched with (10)B, and beryllium oxide thermoluminescent (TL) detectors; with this combined dosimetry, it is possible to discriminate the doses due to thermal neutrons and gamma radiation in a mixed field. Irradiations were carried out inside the thermal column of a TRIGA MARK II water-pool-type research nuclear reactor, also used for Boron Neutron Capture therapy (BNCT) applications, with thermal neutron fluence from 10(9) to 10(14) nth cm(-2). The ESR dosemeters using the alanine-boron compound indicated ESR signals about 30-fold stronger than those using only alanine. Moreover, a negligible correction for the gamma contribution, measured with TL detectors, almost insensitive to thermal neutrons, was necessary. Therefore, a simultaneous analysis of our TL and ESR detectors allows discrimination between thermal neutron and gamma doses, as required in BNCT.


Assuntos
Terapia por Captura de Nêutron de Boro/métodos , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Raios gama/uso terapêutico , Nêutrons/uso terapêutico , Proteção Radiológica/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosimetria Termoluminescente/métodos , Carga Corporal (Radioterapia) , Boro/efeitos da radiação , Terapia por Captura de Nêutron de Boro/instrumentação , Humanos , Isótopos/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Integração de Sistemas , Dosimetria Termoluminescente/instrumentação
9.
Phys Med Biol ; 46(2): 461-71, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11229726

RESUMO

Solid state pellets (1 mm thick) for electron spin resonance (ESR) dosimetry were made using ammonium tartrate as the radiation-sensitive substance. Their behaviour was experimentally investigated as a function of dose with 60Co gamma rays. The calibration function obtained permits measurements of absorbed dose in the 2-50 Gy range, with a combined uncertainty of +/-4%. The lowest detectable dose was about 0.5 Gy. These properties are comparable with or even better than those of ESR dosimeters made from other materials. The time stability of the ESR signal of ammonium tartrate dosimeters at different storage conditions after irradiation was studied. A rather complex behaviour was observed, which suggests that more species of free radicals are produced by radiation and that migration processes may be effective. No dependence of the response on beam quality was found for high-energy photon and electron beams produced by a linear accelerator used in radiotherapy, whereas dose was underestimated with low-energy x-rays.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Radiometria/métodos , Fenômenos Biofísicos , Biofísica , Elétrons/uso terapêutico , Radicais Livres/efeitos da radiação , Humanos , Microesferas , Tamanho da Partícula , Fótons/uso terapêutico , Radiometria/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador , Tartaratos/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...