Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Dent ; 134: 104549, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37196686

RESUMO

OBJECTIVE: To evaluate the adhesion of Streptococcus mutans (S. mutans) and related surface properties of ion-releasing resin-based composite (RBC) restorative materials. METHODS: Two ion-releasing RBCs, Activa (ACT) and Cention-N (CN), were compared to a conventional RBC (Z350) and a resin-modified glass ionomer cement (Fuji-II-LC). Ten disk-shaped specimens were fabricated for each material (n = 40). After standardized surface polishing procedure, the surface properties of the specimens were evaluated using surface roughness measurements by a profilometer and hydrophobicity using water contact angle measurements. To assess bacterial adhesion, the number of S. mutans bacteria was calculated from colony-forming units (CFU). Confocal laser scanning microscope analysis was done for qualitative & quantitative assessment. The data were analyzed using One-way ANOVA followed by Tukey's post-hoc test to compare the mean values of surface roughness, water contact angle and CFU values. To compare the mean dead cell percentage Kruskal-Wallis rank test and Conover test were used. A p-value of ≤ 0.05 was used to report the statistical significance. RESULTS: Z350 and ACT had the smoothest surfaces, followed by CN, and the roughest surface was seen in FUJI-II-LC. The lowest water contact angles were seen in CN, and Z350, and the highest were in ACT. S. mutans counts were the highest in ACT and the lowest in Z350 and CN. CN and Fuji-II-LC registered the highest percentage of dead bacterial cells, while the lowest were in ACT. SIGNIFICANCE: Surface properties did not significantly influence bacterial adhesion. More S. mutans bacteria accumulated on ACT than on the nanofilled composite and on CN. CN had antibacterial effects against Streptococcus mutans biofilms.


Assuntos
Resinas Compostas , Streptococcus mutans , Resinas Compostas/farmacologia , Teste de Materiais , Materiais Dentários/farmacologia , Biofilmes , Aderência Bacteriana , Propriedades de Superfície , Água
2.
Dent Mater ; 38(12): 1866-1877, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36202659

RESUMO

OBJECTIVES: To investigate the depth of cure (DoC), fracture toughness (KIC) and wear of ion releasing resin-based composite (RBC) restorative materials. METHODS: Two ion releasing RBCs, Activa (ACT) and Cention-N (CN) were compared to a conventional RBC (Z350) and a resin-modified glass ionomer cement (Fuji-II-LC). The DoC was measured in a 10-mm deep semi-circular metal mold with a 2-mm internal radius (n = 8). The molds were irradiated from one end for 20-s. The Knoop hardness (KH) was measured at 0.5-mm intervals from the surface after the specimens had been stored at 37 °C for 24-h. To measure the KIC, single-edge-notched specimens (n = 15/group) were prepared (25×5x2.5-mm) for a 3-point bending test and then stored for either 1 or 30-days in water at 37 °C. Disk-shaped specimens (n = 10) were subjected to 250,000-load cycles of 49-N using a chewing simulator against spherical steatite antagonists. DoC and wear data were analyzed by one-way ANOVA and Tukey post hoc tests (p ≤ 0.05). KIC data were analyzed by two-way ANOVA and one-way ANOVA, and the Tukey post hoc test (p ≤ 0.05). In addition, an independent t-test was used to determine if storage time had any effect (α = 0.05) on the KIC of each material. RESULTS: Maximum hardness value was the highest for Z350 and the lowest for ACT. The depth at which 80% of the maximum KH, was the highest for CN (9.2 mm) and the lowest for Z350 (2 mm). All tested materials met the manufacturers' claims for DoC. After 1-day, the highest KIC values were recorded for ACT and the lowest for Fuji-II-LC. Water storage (30-days) significantly reduced the KIC value for all materials except Fuji-II-LC. The highest wear rate values were recorded for CN followed by ACT. SIGNIFICANCE: All tested materials met their manufacturers' claims for DoC. Water storage for 30-days significantly reduced the fracture toughness for ACT and CN. Wear was significantly higher for ACT and CN.


Assuntos
Resinas Compostas , Cimentos de Ionômeros de Vidro , Teste de Materiais , Materiais Dentários , Dureza , Água , Propriedades de Superfície
3.
Artigo em Inglês | MEDLINE | ID: mdl-33535384

RESUMO

OBJECTIVES: The aim of this study was to investigate and compare the level of halitosis in patients with/without fixed crowns and in addition the influence of various crown parameters on halitosis was also explored. METHODS: In total, 96 subjects (fixed crowns = 52; no crowns = 44) participated in the study. The levels volatile sulphur compounds (VSCs) of hydrogen sulphide (H2S), methyl mercaptan (CH3SH), and dimethyl sulphide (CH3SCH3) were evaluated with breath samples using gas chromatography and used for classification as presence or absence of halitosis. The periodontal clinical parameters for all the participants as well as the crown parameters for participants with fixed crowns were also evaluated. Cross tabulation, Chi-square test, and one-way analysis of variance tests were used for the statistical analysis and comparisons. RESULTS: Breath samples revealed, 50 (52.1%) participants were suffering from halitosis. Out of VSCs, the level of CH3SCH3 (62.5%) was found to be the most prevalent. Significant correlations were observed between the presence of fixed crowns and oral halitosis (p < 0.001). Statistically significant difference in the concentration of H2S and CH3SH (p < 0.001) and no significance for CH3SCH3 (p = 0.075) between patients with/without fixed crowns was found. The presence of halitosis was more prevalent in the subjects with crown parameters (subgingival margin, over-contoured margin, open-crown margin, over-contoured and under-contoured crowns) considered clinically defective/unacceptable (p < 0.05). CONCLUSIONS: Presence of fixed dental crowns significantly contributes to the oral halitosis. Dental crowns with defects significantly impair the hygienic conditions and oral microflora resulting in high prevalence of halitosis.


Assuntos
Halitose , Sulfeto de Hidrogênio , Cromatografia Gasosa , Coroas , Halitose/epidemiologia , Humanos , Compostos de Enxofre
4.
Artigo em Inglês | MEDLINE | ID: mdl-28283096

RESUMO

OBJECTIVES: The aim of this study was to evaluate the impact of routine open mouth osseous temporomandibular joint (TMJ) tomography on diagnosis and treatment planning of TMJ conditions. Investigating the need for such images is important to justify the additional radiation exposure imparted by such procedures. STUDY DESIGN: The records of patients who underwent closed- and open-mouth osseous TMJ tomography (planar film tomography up to the beginning of 2006; cone beam computed tomography from 2006 onward) were reviewed. Three examiners formulated a diagnosis and treatment plan based on the history, clinical findings, and tomography interpretation reports of closed-mouth images. Then they reviewed the interpretations of the open-mouth images and recorded whether they would change their original diagnosis and/or treatment plan on the basis of the findings. Descriptive analysis of the results was performed. RESULTS: The impact of routine open-mouth imaging on diagnosis and treatment planning was variable among the examiners. Examiners 1, 2, and 3 had a change in diagnosis in 7%, 5%, and 3% of cases, respectively, and a change in treatment plan in 1%, 1%, and 8%, respectively. CONCLUSIONS: Routine open-mouth osseous TMJ tomography had a minimal impact on diagnosis and treatment planning of TMJ conditions, which varied according to the treating clinician.


Assuntos
Transtornos da Articulação Temporomandibular/diagnóstico por imagem , Adolescente , Adulto , Criança , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Planejamento de Assistência ao Paciente , Intensificação de Imagem Radiográfica/métodos , Transtornos da Articulação Temporomandibular/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...