1.
Int J Radiat Oncol Biol Phys ; 99(3): 719-728, 2017 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-28843372

RESUMO

PURPOSE: Our purpose is to present a novel multisource rotating shield brachytherapy (RSBT) apparatus for the simultaneous precise angular and linear positioning of partially shielded 153Gd brachytherapy sources in interstitial needles for the treatment of locally advanced prostate cancer. It is designed to lower the dose to nearby healthy tissues, the urethra in particular, relative to conventional high-dose-rate brachytherapy techniques. METHODS AND MATERIALS: Following needle implantation through the patient template, an angular drive mechanism is docked to the patient template. Each needle is coupled to a multisource afterloader catheter by a connector passing through a shaft. The shafts are rotated about their axes by translating a moving template between 2 stationary templates. The shafts' surfaces and moving template holes are helically threaded with the same pattern such that translation of the moving template causes simultaneous rotation of the shafts. The rotation of each shaft is mechanically transmitted to the catheter-source-shield combination, inside the needles, via several key-keyway pairs. The catheter angles are simultaneously incremented throughout treatment, and only a single 360° rotation of all catheters is needed for a full treatment. For each rotation angle, source depth in each needle is controlled by a multisource afterloader, which is proposed as an array of belt-driven linear actuators, each of which drives a wire that controls catheter depth in a needle. RESULTS: Treatment plans demonstrated that RSBT with the proposed apparatus reduced urethral D0.1cm3 (the minimum dose delivered to the hottest 0.1cm3 of the urethra) below that of conventional high-dose-rate brachytherapy by 31% for urethral dose gradient volume within 3 mm of the urethra surface. Treatment time to deliver 20 Gy with the proposed multisource RSBT apparatus by use of nineteen 62.4-GBq 153Gd sources was 122 minutes. CONCLUSIONS: The proposed RSBT delivery apparatus enables a mechanically feasible urethra-sparing treatment technique for prostate cancer in a clinically reasonable time frame.


Assuntos
Braquiterapia/instrumentação , Desenho de Equipamento , Gadolínio/uso terapêutico , Neoplasias da Próstata/radioterapia , Radioisótopos/uso terapêutico , Braquiterapia/métodos , Estudos de Viabilidade , Humanos , Masculino , Agulhas , Tratamentos com Preservação do Órgão/instrumentação , Tratamentos com Preservação do Órgão/métodos , Órgãos em Risco , Neoplasias da Próstata/patologia , Proteção Radiológica/instrumentação , Proteção Radiológica/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Rotação , Fatores de Tempo , Incerteza , Uretra
2.
Med Phys ; 44(10): 5384-5392, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28744870

RESUMO

PURPOSE: To provide a fast computational method, based on the proximal graph solver (POGS) - A convex optimization solver using the alternating direction method of multipliers (ADMM), for calculating an optimal treatment plan in rotating shield brachytherapy (RSBT). RSBT treatment planning has more degrees of freedom than conventional high-dose-rate brachytherapy due to the addition of emission direction, and this necessitates a fast optimization technique to enable clinical usage. METHODS: The multi-helix RSBT (H-RSBT) delivery technique was investigated for five representative cervical cancer patients. Treatment plans were generated for all patients using the POGS method and the commercially available solver IBM ILOG CPLEX. The rectum, bladder, sigmoid colon, high-risk clinical target volume (HR-CTV), and HR-CTV boundary were the structures included in our optimization, which applied an asymmetric dose-volume optimization with smoothness control. Dose calculation resolution was 1 × 1 × 3 mm3 for all cases. The H-RSBT applicator had 6 helices, with 33.3 mm of translation along the applicator per helical rotation and 1.7 mm spacing between dwell positions, yielding 17.5° emission angle spacing per 5 mm along the applicator. RESULTS: For each patient, HR-CTV D90 , HR-CTV D100 , rectum D2cc , sigmoid D2cc , and bladder D2cc matched within 1% for CPLEX and POGS methods. Also, similar EQD2 values between CPLEX and POGS methods were obtained. POGS was around 18 times faster than CPLEX. For all patients, total optimization times were 32.1-65.4 s for CPLEX and 2.1-3.9 s for POGS. CONCLUSIONS: POGS reduced treatment plan optimization time approximately 18 times for RSBT with similar HR-CTV D90 , organ at risk (OAR) D2cc values, and EQD2 values compared to CPLEX, which is significant progress toward clinical translation of RSBT.


Assuntos
Braquiterapia , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Rotação , Humanos , Neoplasias/radioterapia , Dosagem Radioterapêutica , Fatores de Tempo
3.
Med Phys ; 42(11): 6579-88, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26520749

RESUMO

PURPOSE: To present a novel brachytherapy technique, called multihelix rotating shield brachytherapy (H-RSBT), for the precise angular and linear positioning of a partial shield in a curved applicator. H-RSBT mechanically enables the dose delivery using only linear translational motion of the radiation source/shield combination. The previously proposed approach of serial rotating shield brachytherapy (S-RSBT), in which the partial shield is rotated to several angular positions at each source dwell position [W. Yang et al., "Rotating-shield brachytherapy for cervical cancer," Phys. Med. Biol. 58, 3931-3941 (2013)], is mechanically challenging to implement in a curved applicator, and H-RSBT is proposed as a feasible solution. METHODS: A Henschke-type applicator, designed for an electronic brachytherapy source (Xoft Axxent™) and a 0.5 mm thick tungsten partial shield with 180° or 45° azimuthal emission angles and 116° asymmetric zenith angle, is proposed. The interior wall of the applicator contains six evenly spaced helical keyways that rigidly define the emission direction of the partial radiation shield as a function of depth in the applicator. The shield contains three uniformly distributed protruding keys on its exterior wall and is attached to the source such that it rotates freely, thus longitudinal translational motion of the source is transferred to rotational motion of the shield. S-RSBT and H-RSBT treatment plans with 180° and 45° azimuthal emission angles were generated for five cervical cancer patients with a diverse range of high-risk target volume (HR-CTV) shapes and applicator positions. For each patient, the total number of emission angles was held nearly constant for S-RSBT and H-RSBT by using dwell positions separated by 5 and 1.7 mm, respectively, and emission directions separated by 22.5° and 60°, respectively. Treatment delivery time and tumor coverage (D90 of HR-CTV) were the two metrics used as the basis for evaluation and comparison. For all the generated treatment plans, the D90 of the HR-CTV in units of equivalent dose in 2 Gy fractions (EQD2) was escalated until the D2cc (minimum dose to hottest 2 cm3) tolerance of either the bladder (90 Gy3), rectum (75 Gy3), or sigmoid colon (75 Gy3) was reached. RESULTS: Treatment time changed for H-RSBT versus S-RSBT by -7.62% to 1.17% with an average change of -2.8%, thus H-RSBT treatments times tended to be shorter than for S-RSBT. The HR-CTV D90 also changed by -2.7% to 2.38% with an average of -0.65%. CONCLUSIONS: H-RSBT is a mechanically feasible delivery technique for use in the curved applicators needed for cervical cancer brachytherapy. S-RSBT and H-RSBT were clinically equivalent for all patients considered, with the H-RSBT technique tending to require less time for delivery.


Assuntos
Braquiterapia/instrumentação , Braquiterapia/métodos , Neoplasias do Colo do Útero/radioterapia , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Modelos Teóricos , Movimento (Física) , Dosagem Radioterapêutica , Fatores de Tempo
4.
Med Phys ; 42(10): 5992-6003, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26429274

RESUMO

PURPOSE: The authors present a novel paddle-based rotating-shield brachytherapy (P-RSBT) method, whose radiation-attenuating shields are formed with a multileaf collimator (MLC), consisting of retractable paddles, to achieve intensity modulation in high-dose-rate brachytherapy. METHODS: Five cervical cancer patients using an intrauterine tandem applicator were considered to assess the potential benefit of the P-RSBT method. The P-RSBT source used was a 50 kV electronic brachytherapy source (Xoft Axxent™). The paddles can be retracted independently to form multiple emission windows around the source for radiation delivery. The MLC was assumed to be rotatable. P-RSBT treatment plans were generated using the asymmetric dose-volume optimization with smoothness control method [Liu et al., Med. Phys. 41(11), 111709 (11pp.) (2014)] with a delivery time constraint, different paddle sizes, and different rotation strides. The number of treatment fractions (fx) was assumed to be five. As brachytherapy is delivered as a boost for cervical cancer, the dose distribution for each case includes the dose from external beam radiotherapy as well, which is 45 Gy in 25 fx. The high-risk clinical target volume (HR-CTV) doses were escalated until the minimum dose to the hottest 2 cm(3) (D(2cm(3)) of either the rectum, sigmoid colon, or bladder reached their tolerance doses of 75, 75, and 90 Gy3, respectively, expressed as equivalent doses in 2 Gy fractions (EQD2 with α/ß = 3 Gy). RESULTS: P-RSBT outperformed the two other RSBT delivery techniques, single-shield RSBT (S-RSBT) and dynamic-shield RSBT (D-RSBT), with a properly selected paddle size. If the paddle size was angled at 60°, the average D90 increases for the delivery plans by P-RSBT on the five cases, compared to S-RSBT, were 2.2, 8.3, 12.6, 11.9, and 9.1 Gy10, respectively, with delivery times of 10, 15, 20, 25, and 30 min/fx. The increases in HR-CTV D90, compared to D-RSBT, were 16.6, 12.9, 7.2, 3.7, and 1.7 Gy10, respectively. P-RSBT HR-CTV D90-values were insensitive to the paddle size for paddles angled at less than 60°. Increasing the paddle angle from 5° to 60° resulted in only a 0.6 Gy10 decrease in HR-CTV D90 on average for five cases when the delivery times were set to 15 min/fx. The HR-CTV D90 decreased to 2.5 and 11.9 Gy10 with paddle angles of 90° and 120°, respectively. CONCLUSIONS: P-RSBT produces treatment plans that are dosimetrically and temporally superior to those of S-RSBT and D-RSBT, although P-RSBT systems may be more mechanically challenging to develop than S-RSBT or D-RSBT. A P-RSBT implementation with 4-6 shield paddles would be sufficient to outperform S-RSBT and D-RSBT if delivery times are constrained to less than 15 min/fx.


Assuntos
Braquiterapia/instrumentação , Rotação , Braquiterapia/efeitos adversos , Humanos , Neoplasias/radioterapia , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador