Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Am Heart J ; 269: 15-24, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38042457

RESUMO

BACKGROUND AND OBJECTIVE: Patients with palpitations clinically suggestive of paroxysmal supraventricular tachycardia (PSVT) are often managed conservatively until ECG-documentation of the tachycardia, leading to high impact on life quality and healthcare resource utilization. We evaluated results of electrophysiological study (EPS), and ablation when appropriate, among these patients, with special focus on gender differences in management. METHODS: BELIEVE SVT is a European multicenter, retrospective registry in tertiary hospitals performing EPS in patients with palpitations, without ECG-documentation of tachycardia or preexcitation, and considered highly suggestive of PSVT by a cardiologist or cardiac electrophysiologist. We analyzed clinical characteristics, results of EPS and ablation, complications, and clinical outcomes during follow-up. RESULTS: Six-hundred eighty patients from 20 centers were included. EPS showed sustained tachycardia in 60.9% of patients, and substrate potentially enabling AVNRT in 14.7%. No major/permanent complications occurred. Minor/transient complications were reported in 0.84% of patients undergoing diagnostic-only EPS and 1.8% when followed by ablation. During a 3.4-year follow-up, 76.2% of patients remained free of palpitations recurrence. Ablation (OR: 0.34, P < .01) and male gender (OR: 0.58, P = .01) predicted no recurrence. Despite a higher female proportion among patients with recurrence, (77.2% vs 63.5% among those asymptomatic during follow-up, P < .01), 73% of women in this study reported no recurrence of palpitations after EPS. CONCLUSIONS: EPS and ablation are safe and effective in preventing recurrence of nondocumented palpitations clinically suggestive of PSVT. Despite a lower efficacy, this strategy is also highly effective among women and warrants no gender differences in management.


Assuntos
Ablação por Cateter , Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Masculino , Feminino , Estudos Retrospectivos , Carga de Sintomas , Taquicardia Paroxística/diagnóstico , Arritmias Cardíacas/cirurgia , Sistema de Registros
2.
Circ Arrhythm Electrophysiol ; 16(8): 447-455, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37485678

RESUMO

BACKGROUND: The analysis of the wave-front activation patterns is crucial for the comprehension and treatment of ventricular tachycardia (VT). The ventricular electrograms duration map (VEDUM) is a potential method to identify areas (VEDUM area) with slow and inhomogeneous activation. There is no available data on the characteristics and the arrhythmogenic role of VEDUM areas identified during sinus/paced rhythm. METHODS: Patients referred for VT ablation were enrolled at 3 different centers. VEDUM maps during sinus/paced rhythm as well as substrate and functional maps were created; activation mapping was performed for all hemodynamically tolerated VT. RESULTS: Thirty-two patients (mean age:70.1±9.4 years; males 93.8%) were enrolled. The VEDUM approach was achieved in all patients and the mean size of the VEDUM area was 12.1±6.9 cm2 (interquartile range, 7.8-14.9 cm2). A significative difference was observed between the electrogram duration in the VEDUM area and the normal tissue (163.7 ms [interquartile range, 142.3-199.2 ms]; versus 65.5 ms [interquartile range, 59.5-76.2 ms]; P<0.001). The VEDUM area was visualized in a dense scar (<0.5 mV) in 19 (59.4%) patients. A deceleration zone and late potentials were recorded inside the VEDUM area in 56.3% and 81.3%, respectively. When a complete VT activation mapping was available, the isthmus projected in the VEDUM area in 93.5% of patients; 8 of them had multiple VTs mapped and in the 87.5% all VT isthmuses were included in the VEDUM area. CONCLUSIONS: VEDUM maps allow the identification of discrete areas of inhomogeneous and slow conduction. They represent a potential target for VT ablation, including patients with multiple morphologies.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Ventrículos do Coração/cirurgia , Arritmias Cardíacas , Frequência Cardíaca/fisiologia , Ablação por Cateter/métodos
3.
Eur J Heart Fail ; 25(5): 740-750, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36781200

RESUMO

AIM: To compare the risk of ventricular arrhythmias (VA) and sudden death (SD) between New York Heart Association (NYHA) class I and NYHA class II-III patients with non-ischaemic cardiomyopathy (NICM). METHODS AND RESULTS: Observational retrospective cohort study including patients with NICM who underwent cardiac magnetic resonance at two hospitals. The primary endpoint included appropriate implantable cardioverter defibrillator (ICD) therapies, sustained ventricular tachycardia, resuscitated cardiac arrest and SD. The secondary endpoint included heart failure (HF) hospitalizations, heart transplant, left ventricular assist device implant or HF death. Overall, 698 patients were included, 33% in NYHA class I. During a median follow-up of 31 months, the primary endpoint occurred in 57 patients (8%), with no differences between NYHA class I and NYHA class II-III cases (7% vs. 9%, p = 0.62). Late gadolinium enhancement (LGE) was the only independent predictor of the primary outcome both in NYHA class I and NYHA class II-III patients. LGE+ NYHA class I patients had a similar cumulative incidence of the primary endpoint as compared to LGE+ NYHA class II-III (p = 0.92) and a significantly higher risk as compared to LGE- NYHA class II-III cases (p < 0.001). The risk of the secondary endpoint was significantly higher in patients in NYHA class II-III as compared to those in NYHA class I (hazard ratio 3.2, p = 0.001). CONCLUSIONS: Patients with NICM in NYHA class I are not necessarily at low risk of VA and SD. Actually, LGE+ NYHA class I patients have a high risk. NYHA class I patients with high-risk factors, such as LGE, could benefit from primary prevention ICD at least as much as those in NYHA class II-III with the same risk factors.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Insuficiência Cardíaca , Isquemia Miocárdica , Humanos , Meios de Contraste , Gadolínio , Estudos Retrospectivos , Insuficiência Cardíaca/terapia , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/epidemiologia , Isquemia Miocárdica/complicações , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Fatores de Risco , Desfibriladores Implantáveis/efeitos adversos
4.
Eur Heart J Cardiovasc Imaging ; 24(3): 346-353, 2023 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-35699462

RESUMO

AIMS: To evaluate the baseline characteristics and the prognostic implications associated with late gadolinium enhancement limited to the right ventricular insertion points (IP-LGE) or present at both the right ventricular insertion points and the left ventricle (IP&LV-LGE) in non-ischaemic dilated cardiomyopathy (DCM). METHODS AND RESULTS: This is a retrospective observational multicentre cohort study including 1165 consecutive patients with DCM evaluated by cardiac magnetic resonance. The primary endpoint included appropriate defibrillator therapies, sustained ventricular tachycardia, resuscitated cardiac arrest, or sudden death. The secondary outcome encompassed heart failure hospitalizations, heart transplant, left ventricular assist device implantation, and end-stage heart failure death. IP-LGE was found in 72 patients (6%), who had clinical characteristics closer to LGE- than to LGE+ patients. During follow-up (median 36 months), none of the IP-LGE patients experienced the primary endpoint. The cumulative incidence of the primary endpoint was similar between IP-LGE and LGE- patients (P = 1), while IP-LGE had significantly lower cumulative incidence when compared with LGE+ patients (P < 0.001). When compared with IP-LGE patients, the cumulative incidence of the secondary endpoint was similar in LGE- cases (P = 0.86) but tended to be higher in LGE+ patients (P = 0.06). Both clinical characteristics and outcomes were similar between IP&LV-LGE patients and the rest of LGE+ cases. CONCLUSIONS: In a large cohort of DCM patients, IP-LGE was associated with similar outcome when compared with LGE- patients and with significant lower risk of ventricular arrhythmias and sudden death when compared with LGE+ cases. Patients with IP&LV-LGE had clinical characteristics and outcomes similar to the rest of LGE+ cases.


Assuntos
Cardiomiopatia Dilatada , Insuficiência Cardíaca , Humanos , Prognóstico , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/terapia , Cardiomiopatia Dilatada/complicações , Ventrículos do Coração/diagnóstico por imagem , Meios de Contraste , Gadolínio , Estudos de Coortes , Imagem Cinética por Ressonância Magnética/métodos , Insuficiência Cardíaca/complicações , Morte Súbita , Valor Preditivo dos Testes
5.
Int J Cardiol ; 355: 9-14, 2022 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-35176405

RESUMO

AIMS: To evaluate predictors of electrical storm (ES), including chronic total occlusion in an infarct-related coronary artery (infarct-related artery CTO, IRACTO), in a cohort of patients with prior myocardial infarction (MI) and implantable cardioverter-defibrillators (ICD). METHODS: Multicenter observational cohort study including 643 consecutive patients with prior MI and a first ICD implanted between 2005 and 2018 at three tertiary hospitals. All the patients included in the study had undergone a diagnostic coronary angiography before ICD implantation. The variable prior ventricular arrhythmias (VA+) was positive in patients with secondary prevention ICDs and in those with at least one appropriate ICD therapy after primary prevention implantation. RESULTS: During a median follow-up of 42 months 59 patients (9%) suffered ES. The presence of at least one IRACTO not revascularized (IRACTO-NR) was associated with a significantly higher cumulative incidence of ES (14.5% vs 4.8%, p < 0.001). IRACTO-NR maintained a significant association with ES after adjustment for potential confounders (HR 2.3, p = 0.005) and was an independent predictor of ES together with VA+ and LVEF. The best cut-off of LVEF to predict ES was ≤38%. A risk-prediction model based on IRACTO-NR, VA+ and LVEF≤38% identified three categories of ES risk (low, intermediate and high), with progressively increasing cumulative incidence of ES (2.2%, 9% and 20%). CONCLUSION: In a cohort of patients with prior MI and ICD, IRACTO-NR is an independent predictor of ES. A new risk-prediction model allowed the identification of three categories of risk, with potentially important clinical implications.


Assuntos
Desfibriladores Implantáveis , Infarto do Miocárdio , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Humanos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/terapia , Fatores de Risco , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/epidemiologia , Resultado do Tratamento
6.
J Card Fail ; 28(8): 1278-1286, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35176484

RESUMO

BACKGROUND: To evaluate the association between sex and ventricular arrhythmias (VA) or sudden death (SD) in nonischemic dilated cardiomyopathy, including analysis of potential confounders. METHODS AND RESULTS: Retrospective cohort study of consecutive patients with DCM referred for cardiac magnetic resonance at 2 tertiary hospitals. The primary combined end point encompassed sustained VA, appropriate implantable cardioverter defibrillator therapies, resuscitated cardiac arrest, and SD. We included 1165 patients with median follow-up of 36 months (interquartile range 20-58 months). The majority of patients (66%) were males. Males and females had similar left ventricular ejection fraction, but the prevalence of late gadolinium enhancement (LGE) at cardiac magnetic resonance was significantly higher among males (48% vs 30%, P < .001). Males had higher cumulative incidence of the primary end point (8% vs 4%, P = .02), and male sex was a significant predictor of the primary end point at univariate analysis (hazard ratio 1.93, P = .02). However, LGE had a major confounding effect in the association between sex and the primary outcome: the hazard ratio of male sex adjusted for LGE was 1.29 (P = .37). LGE+ females had significantly higher cumulative incidence of the primary end point than LGE- males (13% vs 1.8%, P < .001). CONCLUSIONS: In patients with DCM, the prevalence of LGE is significantly higher among males, implying a major confounding effect in the association between male sex and VA or SD. LGE+ females have significantly higher risk than LGE- males. These data do not support the inclusion of sex into risk stratification algorithms for VA or SD in DCM.


Assuntos
Cardiomiopatia Dilatada , Insuficiência Cardíaca , Arritmias Cardíacas , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico , Cicatriz/complicações , Meios de Contraste , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Feminino , Gadolínio , Insuficiência Cardíaca/complicações , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
8.
JACC Clin Electrophysiol ; 8(1): 101-111, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34600848

RESUMO

OBJECTIVES: This study aimed to identify risk factors for infection after secondary cardiac implantable electronic device (CIED) procedures. BACKGROUND: Risk factors for CIED infection are not well defined and techniques to minimize infection lack supportive evidence. WRAP-IT (World-wide Randomized Antibiotic Envelope Infection Prevention trial), a large study that assessed the safety and efficacy of an antibacterial envelope for CIED infection reduction, offers insight into procedural details and infection prevention strategies. METHODS: This analysis included 2,803 control patients from the WRAP-IT trial who received standard preoperative antibiotics but not the envelope (44 patients with major infections through all follow-up). A multivariate least absolute shrinkage and selection operator machine learning model, controlling for patient characteristics and procedural variables, was used for risk factor selection and identification. Risk factors consistently retaining predictive value in the model (appeared >10 times) across 100 iterations of imputed data were deemed significant. RESULTS: Of the 81 variables screened, 17 were identified as risk factors with 6 being patient/device-related (nonmodifiable) and 11 begin procedure-related (potentially modifiable). Patient/device-related factors included higher number of previous CIED procedures, history of atrial arrhythmia, geography (outside North America and Europe), device type, and lower body mass index. Procedural factors associated with increased risk included longer procedure time, implant location (non-left pectoral subcutaneous), perioperative glycopeptide antibiotic versus nonglycopeptide, anticoagulant, and/or antiplatelet use, and capsulectomy. Factors associated with decreased risk of infection included chlorhexidine skin preparation and antibiotic pocket wash. CONCLUSIONS: In WRAP-IT patients, we observed that several procedural risk factors correlated with infection risk. These results can help guide infection prevention strategies to minimize infections associated with secondary CIED procedures.


Assuntos
Desfibriladores Implantáveis , Infecções Relacionadas à Prótese , Antibioticoprofilaxia , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Humanos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco
9.
J Am Coll Cardiol ; 77(23): 2890-2905, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-34112317

RESUMO

BACKGROUND: Risk stratification for ventricular arrhythmias (VA) and sudden death in nonischemic dilated cardiomyopathy (DCM) remains suboptimal. OBJECTIVES: The goal of this study was to provide an improved risk stratification algorithm for VA and sudden death in DCM. METHODS: This was a retrospective cohort study of consecutive patients with DCM who underwent cardiac magnetic resonance with late gadolinium enhancement (LGE) at 2 tertiary referral centers. The combined arrhythmic endpoint included appropriate implantable cardioverter-defibrillator therapies, sustained ventricular tachycardia, resuscitated cardiac arrest, and sudden death. RESULTS: In 1,165 patients with a median follow-up of 36 months, LGE was an independent and strong predictor of the arrhythmic endpoint (hazard ratio: 9.7; p < 0.001). This association was consistent across all strata of left ventricular ejection fraction (LVEF). Epicardial LGE, transmural LGE, and combined septal and free-wall LGE were all associated with heightened risk. A simple algorithm combining LGE and 3 LVEF strata (i.e., ≤20%, 21% to 35%, >35%) was significantly superior to LVEF with the 35% cutoff (Harrell's C statistic: 0.8 vs. 0.69; area under the curve: 0.82 vs. 0.7; p < 0.001) and reclassified the arrhythmic risk of 34% of patients with DCM. LGE-negative patients with LVEF 21% to 35% had low risk (annual event rate 0.7%), whereas those with high-risk LGE distributions and LVEF >35% had significantly higher risk (annual event rate 3%; p = 0.007). CONCLUSIONS: In a large cohort of patients with DCM, LGE was found to be a significant, consistent, and strong predictor of VA or sudden death. Specific high-risk LGE distributions were identified. A new clinical algorithm integrating LGE and LVEF significantly improved the risk stratification for VA and sudden death, with relevant implications for implantable cardioverter-defibrillator allocation.


Assuntos
Cardiomiopatia Dilatada/complicações , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Medição de Risco/métodos , Taquicardia Ventricular/etiologia , Idoso , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/mortalidade , Feminino , Seguimentos , Humanos , Incidência , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Estudos Retrospectivos , Fatores de Risco , Espanha/epidemiologia , Taxa de Sobrevida/tendências , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Reino Unido/epidemiologia
10.
Europace ; 23(3): 456-463, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33595062

RESUMO

AIMS: During the COVID-19 pandemic, concern regarding its effect on the management of non-communicable diseases has been raised. However, there are no data on the impact on cardiac implantable electronic devices (CIED) implantation rates. We aimed to determine the impact of SARS-CoV2 on the monthly incidence rates and type of pacemaker (PM) and implantable cardiac defibrillator (ICD) implantations in Catalonia before and after the declaration of the state of alarm in Spain on 14 March 2020. METHODS AND RESULTS: Data on new CIED implantations for 2017-20 were prospectively collected by nine hospitals in Catalonia. A mixed model with random intercepts corrected for time was used to estimate the change in monthly CIED implantations. Compared to the pre-COVID-19 period, an absolute decrease of 56.5% was observed (54.7% in PM and 63.7% in ICD) in CIED implantation rates. Total CIED implantations for 2017-19 and January and February 2020 was 250/month (>195 PM and >55 ICD), decreasing to 207 (161 PM and 46 ICD) in March and 131 (108 PM and 23 ICD) in April 2020. In April 2020, there was a significant fall of 185.25 CIED implantations compared to 2018 [95% confidence interval (CI) 129.6-240.9; P < 0.001] and of 188 CIED compared to 2019 (95% CI 132.3-243.7; P < 0.001). No significant differences in the type of PM or ICD were observed, nor in the indication for primary or secondary prevention. CONCLUSIONS: During the first wave of the COVID-19 pandemic, a substantial decrease in CIED implantations was observed in Catalonia. Our findings call for measures to avoid long-term social impact.


Assuntos
COVID-19 , Desfibriladores Implantáveis/tendências , Marca-Passo Artificial/tendências , Padrões de Prática Médica/tendências , Implantação de Prótese/tendências , Humanos , Segurança do Paciente , Estudos Prospectivos , Implantação de Prótese/instrumentação , Espanha , Fatores de Tempo
12.
Catheter Cardiovasc Interv ; 97(1): E1-E11, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32460428

RESUMO

OBJECTIVES: To evaluate whether the revascularization of a coronary chronic total occlusion in an infarct-related artery (IRACTO) may be associated with lower recurrence of ventricular arrhythmias (VA) among patients with a secondary prevention implantable cardioverter defibrillator (ICD). BACKGROUND: IRACTO is increasingly recognized as an independent predictor of VA. It is unknown whether IRACTO revascularization can reduce the burden of VA. METHODS: Multicenter observational cohort study that included consecutive patients with prior myocardial infarction and secondary prevention ICD. The primary endpoint was any appropriate ICD therapy. RESULTS: Among the 460 patients included, 269 (58%) had at least one IRACTO at the coronary angiogram performed before ICD implantation; of these, 20 (7%) had their IRACTO successfully revascularized (IRACTO-R) afterwards. During a median follow-up of 48 months, 229 patients (49%) had at least one appropriate ICD therapy. Patients with IRACTO not revascularized (IRACTO-NR) had the highest incidence of ICD therapies (65%) while patients with IRACTO-R had the lowest (10%, p < .001). In the entire cohort, IRACTO-NR was an independent predictor of appropriate ICD therapies (HR 2.85, p < .001) and appropriate ICD shocks (HR 2.94, p < .001). Among patients with IRACTO at baseline, IRACTO-R was independently associated with a marked reduction of appropriate ICD therapies (HR 0.12, p = .002) and appropriate ICD shocks (HR 0.21, p = .03). CONCLUSIONS: In patients with prior myocardial infarction and secondary prevention ICD, IRACTO revascularization was independently associated with a markedly lower incidence of appropriate ICD therapies and shocks. These results should be corroborated by larger prospective studies.


Assuntos
Oclusão Coronária , Desfibriladores Implantáveis , Infarto do Miocárdio , Intervenção Coronária Percutânea , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/prevenção & controle , Artérias , Oclusão Coronária/diagnóstico por imagem , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Seguimentos , Humanos , Estudos Prospectivos , Fatores de Risco , Prevenção Secundária , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Resultado do Tratamento
13.
Int J Infect Dis ; 101: 290-297, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33035673

RESUMO

OBJECTIVES: To assess the characteristics and risk factors for mortality in patients with severe coronavirus disease-2019 (COVID-19) treated with tocilizumab (TCZ), alone or in combination with corticosteroids (CS). METHODS: From March 17 to April 7, 2020, a real-world observational retrospective analysis of consecutive hospitalized adult patients receiving TCZ to treat severe COVID-19 was conducted at our 750-bed university hospital. The main outcome was all-cause in-hospital mortality. RESULTS: A total of 1,092 patients with COVID-19 were admitted during the study period. Of them, 186 (17%) were treated with TCZ, of which 129 (87.8%) in combination with CS. Of the total 186 patients, 155 (83.3 %) patients were receiving noninvasive ventilation when TCZ was initiated. Mean time from symptoms onset and hospital admission to TCZ use was 12 (±4.3) and 4.3 days (±3.4), respectively. Overall, 147 (79%) survived and 39 (21%) died. By multivariate analysis, mortality was associated with older age (HR = 1.09, p < 0.001), chronic heart failure (HR = 4.4, p = 0.003), and chronic liver disease (HR = 4.69, p = 0.004). The use of CS, in combination with TCZ, was identified as a protective factor against mortality (HR = 0.26, p < 0.001) in such severe COVID-19 patients receiving TCZ. No serious superinfections were observed after a 30-day follow-up. CONCLUSIONS: In patients with severe COVID-19 receiving TCZ due to systemic host-immune inflammatory response syndrome, the use of CS in addition to TCZ therapy, showed a beneficial effect in preventing in-hospital mortality.


Assuntos
Corticosteroides/administração & dosagem , Anticorpos Monoclonais Humanizados/administração & dosagem , Tratamento Farmacológico da COVID-19 , COVID-19/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/virologia , Quimioterapia Combinada , Feminino , Mortalidade Hospitalar , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , SARS-CoV-2/efeitos dos fármacos , SARS-CoV-2/fisiologia
14.
Rev Esp Cardiol (Engl Ed) ; 73(7): 581, 2020 Jul.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32605845
15.
ESC Heart Fail ; 7(5): 3169-3173, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32667740

RESUMO

We present a case of atypical LMNA cardiomyopathy associated with the pathogenic variant p.Arg541Ser. The patient had early-onset severe ventricular arrhythmias but atrioventricular conduction was normal. Segmental motion abnormalities and a large transmural scar, mainly apical and lateral, were found at cardiac magnetic resonance, corresponding to areas of severe wall thinning at computed tomography and of low voltages at electroanatomic mapping. Ventricular tachycardia ablation was successful in controlling ventricular arrhythmias. Few other cases described patients with pathogenic variants in the Arg541 residue, and they displayed similar atypical features, suggesting a genotype-phenotype correlation which may have specific prognostic and therapeutic implications.


Assuntos
Cardiomiopatias , Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas , Cardiomiopatias/cirurgia , Estudos de Associação Genética , Humanos , Lamina Tipo A/genética , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/genética , Taquicardia Ventricular/cirurgia
17.
Rev Esp Cardiol (Engl Ed) ; 73(6): 501, 2020 Jun.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32498944
19.
Heart Rhythm ; 17(7): 1084-1091, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32113896

RESUMO

BACKGROUND: Hypertrophic cardiomyopathy (HCM) carries an increased risk of sudden death due to ventricular arrhythmias (VAs). The implantable cardioverter-defibrillator (ICD) is a well-established therapy for treatment of VA. Monomorphic ventricular tachycardias (MVTs) are frequent in HCM patients and suitable for antitachycardia pacing (ATP) termination. OBJECTIVE: The purpose of this study was to describe ventricular tachycardia (VT) characteristics in a population of HCM patients with ICD and to study the effectiveness and safety of ATP for MVT. METHODS: Data were obtained from the multicenter prospective observational UMBRELLA trial, which included all patients with HCM and ICD followed by the CareLink Monitoring System. All episodes of VA were collected and analyzed. ATP effectiveness and safety were described, and factors related to ATP effectiveness were studied with generalized estimating equation (GEE) models. RESULTS: Among 251 patients followed for 47 months, 67 (26.7%) were implanted as secondary prevention. Fifty-six patients presented 326 episodes of VA (286 [87%] MVT). Mean cycle length was 312 ± 64 ms. Among 264 MVTs that received ICD therapy, 202 (76.5%) were ATP terminated. The first ATP burst was effective in 169 episodes (68.4%), and overall effectiveness of the first or second ATP burst was 73.8%. Multivariate GEE-adjusted analysis showed 2 variables related to ATP effectiveness: programming fast VT zone On vs Off (odds ratio [OR] 2.4; 95% confidence interval [CI] 1.5-5.2; P = .03) and programming ≥2 ATP bursts vs 1 burst only (OR 1.6; 95% CI 1.2-3.4; P = .04; and OR 2.9; 95% CI 1.8-6.3; P = .02; respectively). CONCLUSION: MVT is the predominant VA in HCM patients with ICD. ATP is highly effective in terminating the majority of MVTs, and its proved effectiveness should guide device selection and programming in order to avoid unnecessary high-energy shocks.


Assuntos
Cardiomiopatia Hipertrófica/terapia , Desfibriladores Implantáveis , Prevenção Secundária/métodos , Choque Cardiogênico/prevenção & controle , Taquicardia Ventricular/terapia , Cardiomiopatia Hipertrófica/complicações , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Choque Cardiogênico/etiologia , Taquicardia Ventricular/complicações , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...