1.
Am J Transplant ; 16(8): 2293-9, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26999771

RESUMO

The use of donor extracorporeal membrane oxygenation (ECMO) to improve graft outcomes by some controlled donation after circulatory determination of death (cDCDD) programs raises ethical issues. We reviewed cDCDD protocols using ECMO and the relevant ethics literature to analyze these issues. It is not obvious that ECMO in cDCDD improves graft outcomes. In our opinion, ECMO implemented before death can interfere with end-of-life care and damage bodily integrity. By restoring systemic circulation, ECMO risks invalidating the preceding declaration of death if brain and cardiac perfusion is not adequately excluded because of malfunction or misplacement of the supradiaphragmatic aortic occlusion balloon. The use of ECMO is not compatible with the acronym DCDD because circulation is restored after the determination of death. Because of these deficiencies, we concluded that other techniques are preferable, such as rapid recovery or in situ cold infusion. If ECMO is performed, it requires a specific informed consent and transparency.


Assuntos
Morte Encefálica , Oxigenação por Membrana Extracorpórea/ética , Rejeição de Enxerto/prevenção & controle , Preservação de Órgãos , Transplante de Órgãos , Doadores de Tecidos/provisão & distribuição , Obtenção de Tecidos e Órgãos/métodos , Humanos , Consentimento Livre e Esclarecido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...