1.
Lasers Med Sci ; 31(1): 49-56, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26510575

RESUMO

The aim of this study was to evaluate the effects of simulated pulpal pressure (SPP) on the variation of intrapulpal temperature (ΔT) and microtensile bond strength (µTBS) to dentin submitted to an adhesive technique using laser irradiation. One hundred sound human molars were randomly divided into two groups (n = 50), according to the presence or absence of SPP (15 cm H2O). Each group was divided into five subgroups (n = 10) according to Nd:YAG laser energy (60, 80, 100, 120, 140 mJ/pulse). The samples were sequentially treated with the following: 37 % phosphoric acid, adhesive (Scotchbond Universal), irradiation with Nd:YAG laser (60 s), and light curing (10 s). ΔT was evaluated during laser irradiation using a type K thermocouple. Next, a composite resin block was build up onto the irradiated area. After 48 h, samples were submitted to microtensile test (10 kgf load cell, 0.5 mm/min). Data were analyzed by two-way ANOVA and Tukey tests (p = 0.05). ANOVA revealed significant differences for ΔT and TBS in the presence of SPP. For ΔT, the highest mean (14.3 ± 3.23 °C)(A) was observed in 140 mJ and without SPP. For µTBS, the highest mean (33.4 ± 4.15 MPa)(A) was observed in 140 mJ and without SPP. SPP significantly reduced both ΔT and µTBS during adhesive procedures, lower laser energy parameters resulted in smaller ΔT, and the laser parameters did not influence the µTBS values.


Assuntos
Polpa Dentária , Dentina/química , Dentina/efeitos da radiação , Lasers de Estado Sólido , Pressão , Temperatura , Adesividade , Resinas Compostas/química , Lâmpadas de Polimerização Dentária , Humanos , Resistência à Tração
2.
J Clin Laser Med Surg ; 17(2): 77-85, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11189979

RESUMO

OBJECTIVE: The purpose of the present study was to investigate the effects of ND:YLF laser irradiation (1.31 J/cm2; 250 mJ per pulse), acid etching, and hypermineralization on the shear bond strength (SBS) of the Scotchbond Multi-Purpose Plus (3M Dental Products) bonding system. SUMMARY BACKGROUND DATA: Previous studies had shown that the pretreatment of the dentin substrate with laser irradiation can influence the SBS. METHODS: Sixty bovine incisors were selected and stored at -18 degrees C. Dentinal buccal surface was exposed and radiographs were taken to control dentin thickness. The specimens were separated into 2 groups: (1) the control, which was kept in distilled water at 4 degrees C; (2) the hypermineralized, which was kept in hypermineralizing solution at 4 degrees C for 14 days. Each group was divided into 3 subgroups according to the type of dentin pretreatment used: M (acid etching + primer + bond); AL (acid etching + primer + bond + laser); and LA (laser + acid etching + primer + bond). A standard composite resin cylinder (Z100-3M) was bonded to the dentinal surface and the SBS performed on an Instron machine (500 Kg load cell at 0.5 mm/min), followed by scanning electron microscopy (SEM) and x-ray diffraction analysis. RESULTS: Analysis of variance (ANOVA) determined that the pretreatments influenced the SBS values (p < 0.05): AL (9.96 MPa), M (7.28 MPa), and LA (4.87 MPa). The interaction between the group and pretreatment factors also influenced the SBS (p < 0.05). The highest values were obtained for the interaction control/AL (11.64 MPa). CONCLUSION: The results suggested that dentin treatment with laser after the application of the adhesive system is efficient in achieving higher bond strength and is promising as a possible new adhesive substrate.


Assuntos
Condicionamento Ácido do Dente/métodos , Colagem Dentária/métodos , Adesivos Dentinários/uso terapêutico , Terapia a Laser , Cimentos de Resina , Remineralização Dentária/métodos , Análise de Variância , Animais , Bovinos , Resinas Compostas , Avaliação Pré-Clínica de Medicamentos , Incisivo , Microscopia Eletrônica de Varredura , Dióxido de Silício/uso terapêutico , Resistência à Tração , Difração de Raios X , Zircônio/uso terapêutico
3.
Appl Opt ; 32(34): 7106-9, 1993 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-20856575

RESUMO

The optical and crystalline properties of PbF(2) thin films as a function of the substrate temperature during deposition have been studied; the other evaporation conditions were kept as constant as possible. Channel spectra, guided modes, and ellipsometry techniques were used for the analysis of the optical properties of the films. X-ray diffraction was used for the analysis of the crystalline structure.