Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ophthalmol Retina ; 5(5): 450-457, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32866664

RESUMO

PURPOSE: To compare the relative number of retinal pixels and retinal area imaged using the Optos P200DTx (Optos PLC) and Zeiss Clarus 500 (Carl Zeiss Meditec AG) ultra-widefield (UWF) fundus cameras. DESIGN: Single-center retrospective cross-sectional analysis. PARTICIPANTS: Seventy-eight eyes of 46 patients. METHODS: Eyes were imaged with Optos P200DTx, single-capture, and Zeiss Clarus 500, 2 capture montages when possible, UWF fundus cameras. Relative number of pixels encompassing all foveal-centered retinal quadrants were measured. Retinal area was measured with Zeiss Clarus 500 images that were registered to the Optos P200DTx images. Patients and technicians were asked for preferences between the machines. Imaging session times were recorded. MAIN OUTCOME MEASURES: Relative number of retinal pixels and retina area captured by each fundus camera. RESULTS: Optos P200DTx consistently captured more relative pixels compared with Zeiss Clarus 500: 510.4 versus 355.6 (P < 0.001) in total with a similarly statistically significant trend in all 4 quadrants (P < 0.001 for each). For area calculation, 70 of the 78 images achieved successful registration. Optos captured a larger total retinal area: 765.6 versus 566.5 mm2 (P < 0.001) with a similarly statistically significant trend in all 4 quadrants. In the subset of 52 of 70 registered and montaged Zeiss Clarus 500 images, similar results were found. For peripheral pathologic features, Optos P200DTx captured unique findings in 28 images, and Zeiss Clarus 500 captured unique findings 1 image (P < 0.001). Among the 48 imaging sessions in which technicians preferred Optos P200DTx for 28 sessions (58%) and Zeiss Clarus 500 for 20 (42%; P = 0.15). Among patients who responded with a preference, 24 preferred Optos P200DTx and 20 preferred Zeiss Clarus 500 (P = 0.52). Average imaging session time was 4.6 minutes (standard deviation, 3.0 minutes) for Optos P200DTx and 5.2 minutes (standard deviation, 3.0 minutes) for Zeiss Clarus 500 (P = 0.17). CONCLUSIONS: In the current study, the Optos P200DTx captured statistically significantly more retinal area in all 4 quadrants compared with the Zeiss Clarus 500. No statistically significant difference was found in patient or technician preference or image acquisition time between devices.


Assuntos
Angiofluoresceinografia/instrumentação , Fóvea Central/diagnóstico por imagem , Estudos Transversais , Desenho de Equipamento , Fundo de Olho , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos
2.
Otolaryngol Head Neck Surg ; 156(1): 189-193, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-28045639

RESUMO

Objective To compare glossopharyngeal taste between healthy children and those with recurrent acute tonsillitis. Study Design Retrospective cohort study. Setting Pediatric clinics in a tertiary care medical center and satellite location. Subjects and Methods Smell and taste testing was administered to 80 well children and 64 children with recurrent acute tonsillitis (age range, 6-17 years). Smell testing was performed with the NIH Toolbox Odor Identification Test, with scores based on national averages for age and sex. Validated Taste Strips were placed on the midline of the tongue at the circumvallate papillae in random tastant order and in increasing concentrations to test sweet, salty, sour, and bitter. Ordinal logistic regression was used for multivariate analysis. Results The healthy and tonsillitis groups were similar, with mean ages of 11.3 and 10.8 years ( P = .34), respectively. The tonsillitis group had fewer boys (n = 18 vs 43, P = .002), higher mean body mass index (BMI) percentile (n = 72.2 vs 59.8, P = .01), and more subjects with public or no insurance (n = 24 vs 13, P = .004). Univariate analysis revealed no statistically significant differences in rate of normal overall taste (67.2% vs 60%, P = .39) and in sweet (79.7% vs 82.5%, P = .67), salty (85.9% vs 82.8%, P = .82), sour (64.1% vs 70%, P = .48), and bitter (90.6% vs 86.3%, P = .45). In multivariate analysis, smell ability, sex, BMI percentile, parent BMI, and insurance type did not affect overall taste or sweet, salty, sour, or bitter alone. Conclusion Despite controlling for potential intrinsic (sex, smell, BMI) and extrinsic (parent BMI, insurance type) confounders, there was no statistically significant difference in taste among children with recurrent acute tonsillitis as compared with healthy children.


Assuntos
Nervo Glossofaríngeo/fisiopatologia , Percepção Gustatória/fisiologia , Tonsilite/fisiopatologia , Doença Aguda , Adolescente , Índice de Massa Corporal , Estudos de Casos e Controles , Criança , Feminino , Humanos , Masculino , Recidiva , Tonsilite/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...