Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anaesthesia ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38789407

RESUMO

BACKGROUND: It is not certain whether the blade geometry of videolaryngoscopes, either a hyperangulated or Macintosh shape, affects glottic view, success rate and/or tracheal intubation time in patients with expected difficult airways. We hypothesised that using a hyperangulated videolaryngoscope blade would visualise a higher percentage of glottic opening compared with a Macintosh videolaryngoscope blade in patients with expected difficult airways. METHODS: We conducted an open-label, patient-blinded, randomised controlled trial in adult patients scheduled to undergo elective ear, nose and throat or oral and maxillofacial surgery, who were anticipated to have a difficult airway. All airway operators were consultant anaesthetists. Patients were allocated randomly to tracheal intubation with either hyperangulated (C-MAC D-BLADE™) or Macintosh videolaryngoscope blades (C-MAC™). The primary outcome was the percentage of glottic opening. First attempt success was designated a key secondary outcome. RESULTS: We assessed 2540 adults scheduled for elective head and neck surgery for eligibility and included 182 patients with expected difficult airways undergoing orotracheal intubation. The percentage of glottic opening visualised, expressed as median (IQR [range]), was 89 (69-99 [0-100])% with hyperangulated videolaryngoscope blades and 54 (9-90 [0-100])% with Macintosh videolaryngoscope blades (p < 0.001). First-line hyperangulated videolaryngoscopy failed in one patient and Macintosh videolaryngoscopy in 12 patients (13%, p = 0.002). First attempt success rate was 97% with hyperangulated videolaryngoscope blades and 67% with Macintosh videolaryngoscope blades (p < 0.001). CONCLUSIONS: Glottic view and first attempt success rate were superior with hyperangulated videolaryngoscope blades compared with Macintosh videolaryngoscope blades when used by experienced anaesthetists in patients with difficult airways.

2.
Front Med (Lausanne) ; 10: 1292056, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38098848

RESUMO

Purpose: It is unknown if direct epiglottis lifting or conversion to hyperangulated videolaryngoscopes, or even direct epiglottis lifting with hyperangulated videolaryngoscopes, may optimize glottis visualization in situations where Macintosh videolaryngoscopy turns out to be more difficult than expected. This study aims to determine if the percentage of glottic opening (POGO) improvement achieved by direct epiglottis lifting is non-inferior to the one accomplished by a conversion to hyperangulated videolaryngoscopy in these situations. Methods: One or more optimization techniques were applied in 129 difficult Macintosh videolaryngoscopy cases in this secondary analysis of a prospective observational study. Stored videos were reviewed by at least three independent observers who assessed the POGO and six glottis view grades. A linear mixed regression and a linear regression model were fitted. Estimated marginal means were used to analyze differences between optimization maneuvers. Results: In this study, 163 optimization maneuvers (77 direct epiglottis lifting, 57 hyperangulated videolaryngoscopy and 29 direct epiglottis lifting with a hyperangulated videolaryngoscope) were applied exclusively or sequentially. Vocal cords were not visible in 91.5% of the cases with Macintosh videolaryngoscopy, 24.7% with direct epiglottis lifting, 36.8% with hyperangulated videolaryngoscopy and 0% with direct lifting with a hyperangulated videolaryngoscope. Conversion to direct epiglottis lifting improved POGO (mean + 49.7%; 95% confidence interval [CI] 41.4 to 58.0; p < 0.001) and glottis view (mean + 2.2 grades; 95% CI 1.9 to 2.5; p < 0.001). Conversion to hyperangulated videolaryngoscopy improved POGO (mean + 43.7%; 95% CI 34.1 to 53.3; p < 0.001) and glottis view (mean + 1.9 grades; 95% CI 1.6 to 2.2; p < 0.001). The difference in POGO improvement between conversion to direct epiglottis lifting and conversion to hyperangulated videolaryngoscopy is: mean 6.0%; 95% CI -6.5-18.5%; hence non-inferiority was confirmed. Conclusion: When Macintosh videolaryngoscopy turned out to be difficult, glottis exposure with direct epiglottis lifting was non-inferior to the one gathered by conversion to hyperangulated videolaryngoscopy. A combination of both maneuvers yields the best result. Clinical trial registration: ClinicalTrials.gov, NCT03950934.

3.
J Clin Med ; 12(15)2023 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-37568496

RESUMO

BACKGROUND: An inter-incisor gap <3 cm is considered critical for videolaryngoscopy. It is unknown if new generation GlideScope Spectrum™ videolaryngoscopes with low-profile hyperangulated blades might facilitate safe tracheal intubation in these patients. This prospective pilot study aims to evaluate feasibility and safety of GlideScopeTM videolaryngoscopes in severely restricted mouth opening. METHODS: Feasibility study in 30 adults with inter-incisor gaps between 1.0 and 3.0 cm scheduled for ENT or maxillofacial surgery. Individuals at risk for aspiration or rapid desaturation were excluded. RESULTS: The mean mouth opening was 2.2 ± 0.5 cm (range 1.1-3.0 cm). First attempt success rate was 90% and overall success was 100%. A glottis view grade 1 or 2a was achieved in all patients. Nasotracheal intubation was particularly difficult if Magill forceps were required (n = 4). Intubation time differed between orotracheal (n = 9; 33 (25; 39) s) and nasotracheal (n = 21; 55 (38; 94) s); p = 0.049 intubations. The airway operator's subjective ratings on visual analogue scales (0-100) revealed that tube placement was more difficult in individuals with an inter-incisor gap <2.0 cm (n = 10; 35 (29; 54)) versus ≥2.0 cm (n = 20; 20 (10; 30)), p = 0.007, while quality of glottis exposure did not differ. CONCLUSIONS: GlidescopeTM videolaryngoscopy is feasible and safe in patients with severely restricted mouth opening if given limitations are respected.

4.
J Clin Med ; 12(13)2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37445215

RESUMO

BACKGROUND: This prospective study aims to determine whether preoperative stair-climbing tests (SCT) predict postoperative pulmonary complications (PPC) better than self-reported poor functional capacity (SRPFC) in patients with known or suspected COPD. METHODS: A total of 320 patients undergoing scheduled for major non-cardiac surgery, 240 with verified COPD and 80 with GOLD key indicators but disproved COPD, underwent preoperative SRPFC and SCT and were analyzed. Least absolute shrinkage and selection operator (LASSO) regression was used for variable selection. Two multivariable regression models were fitted, the SRPFC model (baseline variables such as sociodemographic, surgical and procedural characteristics, medical preconditions, and GOLD key indicators plus SRPFC) and the SCT model (baseline variables plus SCTPFC). RESULTS: Within all stair-climbing variables, LASSO exclusively selected self-reported poor functional capacity. The cross-validated area under the receiver operating characteristic curve with bias-corrected bootstrapping 95% confidence interval (95% CI) did not differ between the SRPFC and SCT models (0.71; 0.65-0.77 for both models). SRPFC was an independent risk factor (adjusted odds ratio (OR) 5.45; 95% CI 1.04-28.60; p = 0.045 in the SRPFC model) but SCTPFC was not (adjusted OR 3.78; 95% CI 0.87-16.34; p = 0.075 in the SCT model). CONCLUSIONS: Our findings indicate that preoperative SRPFC adequately predicts PPC while additional preoperative SCTs are dispensable in patients with known or suspected COPD.

5.
J Clin Med ; 12(10)2023 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-37240540

RESUMO

BACKGROUND: Transnasal videoendoscopy (TVE) is the standard of care when staging pharyngolaryngeal lesions. This prospective study determined if preoperative TVE improves the prediction of difficult videolaryngoscopic intubation in adults with expected difficult airway management in addition to the Simplified Airway Risk Index (SARI). METHODS: 374 anesthetics were included (252 with preoperative TVE). The primary outcome was a difficult airway alert issued by the anesthetist after Macintosh videolaryngoscopy. SARI, clinical factors (dysphagia, dysphonia, cough, stridor, sex, age and height) and TVE findings were used to fit three multivariable mixed logistic regression models; least absolute shrinkage and selection operator (LASSO) regression was used to select co-variables. RESULTS: SARI predicted the primary outcome (odds ratio [OR] 1.33; 95% confidence interval [CI] 1.13-1.58). The Akaike information criterion for SARI (327.1) improved when TVE parameters were added (311.0). The Likelihood ratio test for SARI plus TVE parameters was better than for SARI plus clinical factors (p < 0.001). Vestibular fold lesions (OR 1.82; 95% CI 0.40-8.29), epiglottic lesions (OR 3.37; 0.73-15.54), pharyngeal secretion retention (OR 3.01; 1.05-8.63), restricted view on rima glottidis <50% (OR 2.13; 0.51-8.89) and ≥50% (OR 2.52; 0.44-14.56) were concerning. CONCLUSION: TVE improved prediction of difficult videolaryngoscopy in addition to traditional bedside airway examinations.

6.
Anesth Analg ; 137(4): 806-818, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36730893

RESUMO

BACKGROUND: Pulmonary function tests (PFTs) such as spirometry and blood gas analysis have been claimed to improve preoperative pulmonary risk assessment, but the scientific literature is conflicting. The Preoperative Diagnostic Tests for Pulmonary Risk Assessment in Chronic Obstructive Pulmonary Disease (PREDICT) study aimed to determine whether preoperative PFTs improve the prediction of postoperative pulmonary complications (PPCs) in patients with known or suspected chronic obstructive pulmonary disease (COPD) undergoing major surgery. A secondary aim was to determine whether the Global Initiative for Chronic Obstructive Lung Diseases (GOLD) classification of airflow limitation severity (grades I-IV) is associated with PPC. METHODS: In this prospective, single-center study, patients with GOLD key indicators for COPD scheduled for major surgery received PFTs. Patients with confirmed COPD (forced expiratory volume in 1 second [FEV1]/forced vital capacity [FVC] ≤0.7) were included in the COPD cohort and compared with a reference cohort without COPD. We developed 3 multivariable risk prediction models and compared their ability to predict PPC: the "standard model" (medical preconditions, and sociodemographic and surgical data), the "COPD assessment model" (additional GOLD key indicators, pack-years, and poor exercise capacity), and the "PFT model" (additional PFT parameters selected by adaptive least absolute shrinkage and selection operator [LASSO] regression). Multiple LASSO regressions were used for cross-validation. RESULTS: A total of 31,714 patients were assessed for eligibility; 1271 individuals received PFTs. Three hundred twenty patients (240 with confirmed COPD: 78 GOLD I, 125 GOLD II, 28 GOLD III, 9 GOLD IV, and 80 without COPD) completed follow-up. The diagnostic performance was similar among the standard model (cross-validated area under the curve [cvAUC], 0.723; bias-corrected bootstrapped [bc-b] 95% confidence interval [CI], 0.663-0.775), COPD assessment model (cvAUC, 0.724; bc-b 95% CI, 0.662-0.777), and PFT model (cvAUC, 0.729; bc-b 95% CI, 0.668-0.782). Previously known COPD was an independent predictor in the standard and COPD assessment model. %FEV1 PRED was the only PFT parameter selected by LASSO regression and was an independent predictor in the PFT model (adjusted odds ratios [OR], 0.98; 95% CI, 0.967-.0.998; P = .030). The risk for PPC significantly increased with GOLD grades ( P < .001). COPD was newly diagnosed in 53.8% of the patients with confirmed COPD; however, these individuals were not at increased risk for PPC ( P = .338). CONCLUSIONS: COPD is underdiagnosed in surgical patients. Patients with newly diagnosed COPD commonly presented with low GOLD severity grades and were not at higher risk for PPC. Neither a structured COPD-specific assessment nor preoperative PFTs added incremental diagnostic value to the standard clinical preassessment in patients with known or suspected COPD. Unnecessary postponement of surgery and undue health care costs can be avoided.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Estudos Prospectivos , Volume Expiratório Forçado , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Pulmão , Espirometria , Capacidade Vital , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Índice de Gravidade de Doença
7.
J Clin Med ; 11(12)2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35743570

RESUMO

BACKGROUND: This study aimed to determine whether prehospital qSOFA (quick sequential organ failure assessment) assessment was associated with a shortened 'time to antibiotics' and 'time to intravenous fluid resuscitation' compared with standard assessment. METHODS: This retrospective study included patients who were referred to our Emergency Department between 2014 and 2018 by emergency medical services, in whom sepsis was diagnosed during hospitalization. Two multivariable regression models were fitted, with and without qSOFA parameters, for 'time to antibiotics' (primary endpoint) and 'time to intravenous fluid resuscitation'. RESULTS: In total, 702 patients were included. Multiple linear regression analysis showed that antibiotics and intravenous fluids were initiated earlier if infections were suspected and emergency medical services involved emergency physicians. A heart rate above 90/min was associated with a shortened time to antibiotics. If qSOFA parameters were added to the models, a respiratory rate ≥ 22/min and altered mentation were independent predictors for earlier antibiotics. A systolic blood pressure ≤ 100 mmHg and altered mentation were independent predictors for earlier fluids. When qSOFA parameters were added, the explained variability of the model increased by 24% and 38%, respectively (adjusted R² 0.106 versus 0.131 for antibiotics and 0.117 versus 0.162 for fluids). CONCLUSION: Prehospital assessment of qSOFA parameters was associated with a shortened time to a targeted sepsis therapy.

8.
Dtsch Arztebl Int ; 119(7): 99-106, 2022 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-34939921

RESUMO

BACKGROUND: Pulmonary function tests (PFTs) such as spirometry and blood gas analysis have been claimed to improve preoperative risk assessment. This systematic review summarizes the available scientific literature regarding the ability of PFTs to predict postoperative pulmonary complications (PPC) in non-thoracic surgery. METHODS: We systematically searched MEDLINE, CINAHL, and the Cochrane Library for pertinent original research articles (PROSPERO CRD42020215502), framed by the PIT-criteria (PIT, participants, index test, target conditions), respecting the PRISMA-DTA recommendations (DTA, diagnostic test accuracy). RESULTS: 46 original research studies were identified that used PFT-findings as index tests and PPC as target condition. QUADAS-2 quality assessment revealed a high risk of bias regarding patient selection, blinding, and outcome definitions. Qualitative synthesis of prospective studies revealed inconclusive study findings: 65% argue for and 35% against preoperative spirometry, and 43% argue for blood gas analysis. A (post-hoc) subgroup analysis in prospective studies with low-risk of selection bias identified a possible benefit in upper abdominal surgery (three studies with 959 participants argued for and one study with 60 participants against spirometry). CONCLUSION: As the existing literature is inconclusive it is currently unknown if PFTs improve risk assessment before non-thoracic surgery. Spirometry should be considered in individuals with key indicators for chronic obstructive pulmonary disease (COPD) scheduling for upper abdominal surgery.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Testes de Função Respiratória/efeitos adversos , Espirometria/efeitos adversos
9.
BMJ Open ; 11(8): e045330, 2021 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-34348946

RESUMO

OBJECTIVES: Transfemoral transcatheter aortic valve implantation (TF-TAVI) is an established therapy for patients with symptomatic aortic stenosis, which requires periprocedural anaesthesia care. In 2015, the German Federal Joint Committee released a directive on minimally invasive heart valve interventions which defines institutional infrastructural requirements in German heart centres. But still generally accepted expert consensus recommendations or national or international guidelines regarding periprocedural anaesthesia management for TF-TAVI are lacking. This nationwide cross-sectional study had two major objectives: first to assess the concordance with existing national regulations regarding infrastructural requirements and second to evaluate the status quo of periprocedural anaesthesia management for patients undergoing TF-TAVI in German heart centres. DESIGN: Multicentre cross-sectional online study to evaluate the periprocedural anaesthesia management. SETTING: In this nationwide cross-sectional study, electronic questionnaires were sent out to anaesthesia departments at TF-TAVI-performing centres in Germany in March 2019. PARTICIPANTS: 78 anaesthesia departments of German heart centres. RESULTS: 54 (69.2%) centres returned the questionnaire of which 94.4% stated to hold regular Heart Team meetings, 75.9% to have ready-to-use heart-lung machines available on-site, 77.8% to have cardiac surgeons and 66.7% to have perfusionists routinely attending throughout TF-TAVI procedures. Regarding periprocedural anaesthesia management, 41 (75.9%) of the participating centres reported to predominantly use 'monitored anaesthesia care' and 13 (24.1%) to favour general anaesthesia. 49 (90.7%) centres stated to use institutional standard operating procedures for anaesthesia. Five-lead ECG, central venous lines, capnometry and intraprocedural echocardiography were reported to be routine measures in 85.2%, 83.3%, 77.8% and 51.9% of the surveyed heart centres. CONCLUSIONS: The concordance with national regulations, anaesthesia management and in-house standards for TF-TAVI vary broadly among German heart centres. According to the opinion of the authors, international expert consensus recommendations and/or guidelines would be helpful to standardise peri interventional anaesthesia care.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Anestesia Geral , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Transversais , Humanos , Resultado do Tratamento
10.
Sci Adv ; 4(9): eaat9349, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30255150

RESUMO

Dirac materials such as graphene and topological insulators (TIs) are known to have unique electronic and spintronic properties. We combine graphene with TIs in van der Waals heterostructures to demonstrate the emergence of a strong proximity-induced spin-orbit coupling in graphene. By performing spin transport and precession measurements supported by ab initio simulations, we discover a strong tunability and suppression of the spin signal and spin lifetime due to the hybridization of graphene and TI electronic bands. The enhanced spin-orbit coupling strength is estimated to be nearly an order of magnitude higher than in pristine graphene. These findings in graphene-TI heterostructures could open interesting opportunities for exploring exotic physical phenomena and new device functionalities governed by topological proximity effects.

11.
Sci Rep ; 7(1): 15231, 2017 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-29123124

RESUMO

The two-dimensional (2D) material graphene is highly promising for Hall sensors due to its potential of having high charge carrier mobility and low carrier concentration at room temperature. Here, we report the scalable batch-fabrication of magnetic Hall sensors on graphene encapsulated in hexagonal boron nitride (h-BN) using commercially available large area CVD grown materials. The all-CVD grown h-BN/graphene/h-BN van der Waals heterostructures were prepared by layer transfer technique and Hall sensors were batch-fabricated with 1D edge metal contacts. The current-related Hall sensitivities up to 97 V/AT are measured at room temperature. The Hall sensors showed robust performance over the wafer scale with stable characteristics over six months in ambient environment. This work opens avenues for further development of growth and fabrication technologies of all-CVD 2D material heterostructures and allows further improvements in Hall sensor performance for practical applications.

12.
Nat Commun ; 8: 16093, 2017 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-28677673

RESUMO

Two-dimensional (2D) crystals offer a unique platform due to their remarkable and contrasting spintronic properties, such as weak spin-orbit coupling (SOC) in graphene and strong SOC in molybdenum disulfide (MoS2). Here we combine graphene and MoS2 in a van der Waals heterostructure (vdWh) to demonstrate the electric gate control of the spin current and spin lifetime at room temperature. By performing non-local spin valve and Hanle measurements, we unambiguously prove the gate tunability of the spin current and spin lifetime in graphene/MoS2 vdWhs at 300 K. This unprecedented control over the spin parameters by orders of magnitude stems from the gate tuning of the Schottky barrier at the MoS2/graphene interface and MoS2 channel conductivity leading to spin dephasing in high-SOC material. Our findings demonstrate an all-electrical spintronic device at room temperature with the creation, transport and control of the spin in 2D materials heterostructures, which can be key building blocks in future device architectures.

13.
ACS Nano ; 11(6): 6389-6395, 2017 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-28557439

RESUMO

The two-dimensional (2D) semiconductor molybdenum disulfide (MoS2) has attracted widespread attention for its extraordinary electrical-, optical-, spin-, and valley-related properties. Here, we report on spin-polarized tunneling through chemical vapor deposited multilayer MoS2 (∼7 nm) at room temperature in a vertically fabricated spin-valve device. A tunnel magnetoresistance (TMR) of 0.5-2% has been observed, corresponding to spin polarization of 5-10% in the measured temperature range of 300-75 K. First-principles calculations for ideal junctions result in a TMR up to 8% and a spin polarization of 26%. The detailed measurements at different temperature, bias voltages, and density functional theory calculations provide information about spin transport mechanisms in vertical multilayer MoS2 spin-valve devices. These findings form a platform for exploring spin functionalities in 2D semiconductors and understanding the basic phenomena that control their performance.

14.
Sci Rep ; 6: 21168, 2016 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-26883717

RESUMO

Two dimensional atomically thin crystals of graphene and its insulating isomorph hexagonal boron nitride (h-BN) are promising materials for spintronic applications. While graphene is an ideal medium for long distance spin transport, h-BN is an insulating tunnel barrier that has potential for efficient spin polarized tunneling from ferromagnets. Here, we demonstrate the spin filtering effect in cobalt|few layer h-BN|graphene junctions leading to a large negative spin polarization in graphene at room temperature. Through nonlocal pure spin transport and Hanle precession measurements performed on devices with different interface barrier conditions, we associate the negative spin polarization with high resistance few layer h-BN|ferromagnet contacts. Detailed bias and gate dependent measurements reinforce the robustness of the effect in our devices. These spintronic effects in two-dimensional van der Waals heterostructures hold promise for future spin based logic and memory applications.

15.
Nano Lett ; 15(12): 7976-81, 2015 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-26560203

RESUMO

Topological insulators (TIs) are a new class of quantum materials that exhibit a current-induced spin polarization due to spin-momentum locking of massless Dirac Fermions in their surface states. This helical spin polarization in three-dimensional (3D) TIs has been observed using photoemission spectroscopy up to room temperatures. Recently, spin polarized surface currents in 3D TIs were detected electrically by potentiometric measurements using ferromagnetic detector contacts. However, these electric measurements are so far limited to cryogenic temperatures. Here we report the room temperature electrical detection of the spin polarization on the surface of Bi2Se3 by employing spin sensitive ferromagnetic tunnel contacts. The current-induced spin polarization on the Bi2Se3 surface is probed by measuring the magnetoresistance while switching the magnetization direction of the ferromagnetic detector. A spin resistance of up to 70 mΩ is measured at room temperature, which increases linearly with current bias, reverses sign with current direction, and decreases with higher TI thickness. The magnitude of the spin signal, its sign, and control experiments, using different measurement geometries and interface conditions, rule out other known physical effects. These findings provide further information about the electrical detection of current-induced spin polarizations in 3D TIs at ambient temperatures and could lead to innovative spin-based technologies.


Assuntos
Eletricidade , Temperatura
16.
Nat Commun ; 6: 6766, 2015 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-25857650

RESUMO

Graphene is an ideal medium for long-distance spin communication in future spintronic technologies. So far, the prospect is limited by the smaller sizes of exfoliated graphene flakes and lower spin transport properties of large-area chemical vapour-deposited (CVD) graphene. Here we demonstrate a high spintronic performance in CVD graphene on SiO2/Si substrate at room temperature. We show pure spin transport and precession over long channel lengths extending up to 16 µm with a spin lifetime of 1.2 ns and a spin diffusion length ∼6 µm at room temperature. These spin parameters are up to six times higher than previous reports and highest at room temperature for any form of pristine graphene on industrial standard SiO2/Si substrates. Our detailed investigation reinforces the observed performance in CVD graphene over wafer scale and opens up new prospects for the development of lateral spin-based memory and logic applications.

17.
Small ; 11(18): 2209-16, 2015 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-25586013

RESUMO

Black phosphorus (BP) has been recently unveiled as a promising 2D direct bandgap semiconducting material. Here, ambipolar field-effect transistor behavior of nanolayers of BP with ferromagnetic tunnel contacts is reported. Using TiO2/Co contacts, a reduced Schottky barrier <50 meV, which can be tuned further by the gate voltage, is obtained. Eminently, a good transistor performance is achieved in the devices discussed here, with drain current modulation of four to six orders of magnitude and a mobility of µh ≈ 155 cm(2) V(-1) s(-1) for hole conduction at room temperature. Magnetoresistance calculations using a spin diffusion model reveal that the source-drain contact resistances in the BP device can be tuned by gate voltage to an optimal range for injection and detection of spin-polarized holes. The results of the study demonstrate the prospect of BP nanolayers for efficient nanoelectronic and spintronic devices.

18.
Sci Rep ; 4: 6146, 2014 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-25156685

RESUMO

The van der Waals heterostructures of two-dimensional (2D) atomic crystals constitute a new paradigm in nanoscience. Hybrid devices of graphene with insulating 2D hexagonal boron nitride (h-BN) have emerged as promising nanoelectronic architectures through demonstrations of ultrahigh electron mobilities and charge-based tunnel transistors. Here, we expand the functional horizon of such 2D materials demonstrating the quantum tunneling of spin polarized electrons through atomic planes of CVD grown h-BN. We report excellent tunneling behavior of h-BN layers together with tunnel spin injection and transport in graphene using ferromagnet/h-BN contacts. Employing h-BN tunnel contacts, we observe enhancements in both spin signal amplitude and lifetime by an order of magnitude. We demonstrate spin transport and precession over micrometer-scale distances with spin lifetime up to 0.46 nanosecond. Our results and complementary magnetoresistance calculations illustrate that CVD h-BN tunnel barrier provides a reliable, reproducible and alternative approach to address the conductivity mismatch problem for spin injection into graphene.

19.
ACS Nano ; 8(1): 476-82, 2014 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-24377305

RESUMO

Molybdenum disulfide has recently emerged as a promising two-dimensional semiconducting material for nanoelectronic, optoelectronic, and spintronic applications. Here, we investigate the field-effect transistor behavior of MoS2 with ferromagnetic contacts to explore its potential for spintronics. In such devices, we elucidate that the presence of a large Schottky barrier resistance at the MoS2/ferromagnet interface is a major obstacle for the electrical spin injection and detection. We circumvent this problem by a reduction in the Schottky barrier height with the introduction of a thin TiO2 tunnel barrier between the ferromagnet and MoS2. This results in an enhancement of the transistor on-state current by 2 orders of magnitude and an increment in the field-effect mobility by a factor of 6. Our magnetoresistance calculation reveals that such integration of ferromagnetic tunnel contacts opens up the possibilities for MoS2-based spintronic devices.

20.
Sci Rep ; 3: 3196, 2013 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-24217343

RESUMO

Implementing spin functionalities in Si, and understanding the fundamental processes of spin injection and detection, are the main challenges in spintronics. Here we demonstrate large spin polarizations at room temperature, 34% in n-type and 10% in p-type degenerate Si bands, using a narrow Schottky and a SiO2 tunnel barrier in a direct tunneling regime. Furthermore, by increasing the width of the Schottky barrier in non-degenerate p-type Si, we observed a systematic sign reversal of the Hanle signal in the low bias regime. This dramatic change in the spin injection and detection processes with increased Schottky barrier resistance may be due to a decoupling of the spins in the interface states from the bulk band of Si, yielding a transition from a direct to a localized state assisted tunneling. Our study provides a deeper insight into the spin transport phenomenon, which should be considered for electrical spin injection into any semiconductor.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...