1.
Biomed Phys Eng Express ; 10(3)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38547526

RESUMO

For the purpose of fixing tibia fractures, composite bone plates are suggested. Metal plates cause stress shielding, lessen the compression force at the fracture site, and have an impact on the healing process because they are significantly more rigid than bone. To prevent excessive shear strain and consequent instability at the fracture site, it is imperative to reduce stiffness in the axial direction without lowering stiffness in the transverse direction. Only a carefully crafted fiber reinforced composite with anisotropic properties will suffice to accomplish this. The purpose of the current study is to examine the impact of axial and shear movements at the fracture site on the fixing of metal and composite bone plates. After modeling the tibia with a 1 mm fracture gap, titanium plates, carbon/epoxy, carbon/PEEK, and carbon/UHMWPE composite bone plates were used to fix it. There are 6 holes on each of the 103 mm long plates. To determine the stresses and axial movement in the fracture site, anatomical 3D Finite Element (FE) models of the tibia with composite bone plates are built. The simulations that were run for various composite plate layouts and types give suggestions for selecting the best composite bone plate. Although the matrix material causes some variations in behaviors, most of the plates perform as well as or even better than metal plates. Thus, the appropriate composite combinations are recommended for a given fracture structure.


Assuntos
Placas Ósseas , Fraturas Ósseas , Humanos , Tíbia/cirurgia , Fixação Interna de Fraturas , Carbono/química
2.
Artigo em Inglês | MEDLINE | ID: mdl-37771233

RESUMO

A dental implant with three distinct layers, of titanium alloy at core, porous titanium alloy at the intermediate layer and titanium alloy hydroxyapatite composite at the outer layer, is designed to achieve low elastic modulus and adequate strength with bioactive surface. Artificial Neural Network (ANN) along with Rule of Mixture (ROM) is used to generate the objective functions for the Genetic Algorithm (GA) based multi-objective optimization for achieving the optimal designs, which are validated using Finite Element Analysis (FEA) simulations. The composition and processing parameters are correlated with the yield strength and elastic modulus of titanium alloy using ANN. The ANN models are generated to express the strength and effective modulus of the implant using ROM. To determine the optimal composition of titanium alloys, porous layers, and composite layers for a three-layer dental implant, multi-objective genetic algorithm is employed. The Pareto optimal solutions provide the guidelines for designing the implant. A few selected non-dominated solutions are used for studying the actual stress distribution at the bone-implant interface using FEA, and showed significant improvements compared to conventional implants.


Assuntos
Implantes Dentários , Titânio , Ligas , Interface Osso-Implante , Informática , Análise de Elementos Finitos , Estresse Mecânico
3.
Materials (Basel) ; 15(23)2022 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-36499941

RESUMO

The present work investigates the friction reduction capability of two types of micro-textures (grooves and dimples) created on steel surfaces using a vertical milling machine. The wear studies were conducted using a pin-on-disc tribometer, with the results indicating a better friction reduction capacity in the case of the dimple texture as compared to the grooved texture. The microscopic images of the pin surface revealed deep furrows and significant damage on the pin surfaces of the groove-textured disc. An optimization of the textured surfaces was performed using an artificial neural network (ANN) model, predicting the influence of the surface texture as a function of the load, depth of cut and distance between the micro-textures.

4.
Proc Inst Mech Eng H ; 236(9): 1288-1296, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35920405

RESUMO

Conventional stainless steel or titanium plates are used for bone fracture fixation to provide support at fracture location. Plates with high elastic modulus reduce the transfer of compressive load at the fracture location (due to stress shielding), causing failure. The objective of the study is to find for composite bone plates with different types of fibers and varied fiber orientations for post-operative (PO) and healed bone (HB) conditions which can reduce the stress shielding. Femur fracture fixation was constructed with 12 holes narrow type with metal and composite bone plates. The fracture gap was constructed with soft bone region for post-operative (PO) condition and harder bone for healed bone (HB). Composite bone plates with different configurations (fiber directions) and types (thickness and width) were analyzed to study the stress distribution and movement in the fracture location. The models were analyzed and the stresses in plate and callus, movement and strain in axial and shear direction in both metal and composite bone plates were studied. The metal and composite plates (carbon fiber/epoxy, fiberglass/epoxy, and flax/epoxy) used for most common Vancouver type B1 fracture to observe the biomechanical behavior of different models in PO and HB condition. The FE simulation on different configurations and types of composite plates provide in-depth idea about choosing the suitable composite bone plate. There are variations in behavior for varying types and configurations, but the performance of most of the plates are either better or similar to that of metal plate, except the plates with higher width.


Assuntos
Placas Ósseas , Fraturas do Fêmur , Fenômenos Biomecânicos , Fraturas do Fêmur/cirurgia , Fêmur/cirurgia , Análise de Elementos Finitos , Fixação de Fratura , Fixação Interna de Fraturas , Humanos , Estresse Mecânico
5.
Int J Artif Organs ; 45(8): 704-714, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35848544

RESUMO

The major concern after total hip arthroplasty (THA) is the incidence of periprosthetic fracture in the weaker bone, which can lead to subsequent revision surgery. Achieving the suitable fixation without affecting the stability of the well-fixed prosthesis remains controversial. Most of the studies examined the behavior of the Periprosthetic Fracture (PF) fixation (Vancouver "B1" type) through computational and experimentation on healthy bone condition with metal plates. The aim of the present study is to analyze the influences of the metal and composite bone plate PF fixation on the axial and shear movement at the fracture site. The PF fixation constructs were modeled with medical graded stainless-steel plate (construct A), titanium plate (construct B) and carbon/epoxy composite bone plate (construct C) with 12 holes and a 4 mm fracture gap. Analysis was carried out for all the stages (stage 1-Normal bone, stage 2-THA, stage 3-Immediate Post-Operative (IPO), stage 4-Post-Operative (PO) and, stage 5-Healed Bone (HB)) under various loadings for intact and osteoporosis conditions. The results showed higher stress in cortical bone for stage 3, whereas in all the other stages lower stresses were experienced in the cortical and cancelous bone under peak load in construct C for osteoporosis model compared with other constructs. The present study suggested the construct C may be suitable for osteoporosis bone conditions.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Osteoporose , Fraturas Periprotéticas , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Placas Ósseas/efeitos adversos , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Humanos , Osteoporose/complicações , Osteoporose/cirurgia , Fraturas Periprotéticas/complicações , Fraturas Periprotéticas/cirurgia
6.
Proc Inst Mech Eng H ; 236(9): 1375-1387, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35880901

RESUMO

The bone conditions of mandibular bone vary from patient to patient, and as a result, a patient-specific dental implant needs to be designed. The basal dental implant is implanted in the cortical region of the bone since the top surface of the bone narrows down because of aging. Taguchi designs of experiments technique are used in which 25 optimum solid models of basal dental implants are modeled with variable geometrical parameters, viz. thread length, diameter, and pitch. In the solid models the implants are placed in the cortical part of the 3D models of cadaveric mandibles, that are prepared from CT data using image processing software. Patient-specific bone conditions are varied according to the strong, weak, and normal basal bone. A compressive force of 200 N is applied on the top surface of these implants and using finite element analysis software, the microstrain on the peri-implant bone ranges from 1000 to 4000 depending on the various bone conditions. According to the finite element data, it can be concluded that weak bone microstrain is comparatively high compared with normal and strong bone conditions. A surrogate artificial neural network model is prepared from the finite element analysis data. Surrogate model assisted genetic algorithm is used to find the optimum patient-specific basal dental implant for a better osseointegration-friendly mechanical environment.


Assuntos
Implantes Dentários , Fenômenos Biomecânicos , Simulação por Computador , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Redes Neurais de Computação , Estresse Mecânico
7.
Comput Methods Programs Biomed ; 196: 105680, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32763643

RESUMO

BACKGROUND AND OBJECTIVES: Composite bone plates are proposed for fracture fixation in periprosthetic femoral fracture. Metallic plates, having high stiffness compared to bone lead to stress shielding, reduce the compression force in the fracture site, affectthe healing process. Reduction of stiffness in the axial direction due to above reason without lowering the stiffness in transverse to avoid much of shear strain and thus avoiding instability at the fracture site leads to selective stress shielding. This can only be achieved through meticulously designed fiber reinforced composite. In the present work varied fiber orientations in the stacked laminates with varied fiber types are employed in a post-operative femur fixation for the in-silico analyses of their effectiveness using finite element analysis. METHODS: In this study a Total Hip Arthroplasty (THA) model is constructed with composite bone plates. Three-dimensional narrow type metal plate is modeled with 12 holes and length of 194 mm. Three different types of composite bone plates are modeled with 12 holes of different size for the analysis i.e. Type 1 (5.6 mm thickness and 16 mm width), Type 2 (6 mm thickness and 16 mm width) and Type 3(6 mm thickness and 18 mm width). Anatomical 3D FE models of THA with composite bone plates are constructed to find out the interfacial stresses and strains. The finite element software ANSYS is used to perform the analysis. RESULTS: A three-dimensional FE model of immediately post-operative femur fixation is developed and studied the maximum stress distribution, strain and movement in axial/shear direction in the metal and composite bone plate near to the fracture site. In the present study, the metal and composite plate (carbon/epoxy, glass/epoxy and flax/epoxy) used for most common Vancouver type B1 fracture to observe the biomechanical behavior of different models in IPO condition using FEA. CONCLUSIONS: Optimizing the fiber orientations of composite bone plates of Total Hip Arthroplasty (THA) model by controlling the biomechanical stresses could be a favorable approach. The finite element analysis approach gives a viable solution to design the composite bone plate and for designing future models that preserves the biomechanical function of THA with composite bone plate.


Assuntos
Placas Ósseas , Fraturas do Fêmur , Fenômenos Biomecânicos , Fraturas do Fêmur/cirurgia , Fêmur/cirurgia , Análise de Elementos Finitos , Fixação de Fratura , Humanos , Estresse Mecânico
8.
Curr Med Imaging ; 16(4): 371-382, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32410539

RESUMO

BACKGROUND: This work uses genetic algorithm (GA) for optimum design of patient specific spinal implants (pedicle screw) with varying implant diameter and bone condition. The optimum pedicle screw fixation in terms of implant diameter is on the basis of minimum strain difference from intact (natural) to implantation at peri-prosthetic bone for the considered six different peri-implant positions. METHODS: This design problem is expressed as an optimization problem using the desirability function, where the data generated by finite element analysis is converted into an artificial neural network (ANN) model. The finite element model is generated from CT scan data. Thereafter all the ANN predictions of the microstrain in six positions are converted to unitless desirability value varying between 0 and 1, which is then combined to form the composite desirability. Maximization of the composite desirability is done using GA where composite desirability should be made to go up as close as possible to 1. If the composite desirability is 1, then all 'strain difference values in 6 positions' are 0. RESULTS: The optimum solutions obtained can easily be used for making patient-specific spinal implants.


Assuntos
Imageamento Tridimensional/métodos , Parafusos Pediculares , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Fusão Vertebral/métodos , Tomografia Computadorizada por Raios X/métodos , Análise de Elementos Finitos , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Redes Neurais de Computação
9.
Int J Numer Method Biomed Eng ; 35(6): e3191, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30801978

RESUMO

The objective is to make the strain deviation before and after implantation adjacent to the femoral implant as close as possible to zero. Genetic algorithm is applied for this optimization of strain deviation, measured in eight separate positions. The concept of composite desirability is introduced in such a way that if the microstrain deviation values for all eight cases are 0, then the composite desirability is 1. Artificial neural network (ANN) models are developed to capture the correlation of the microstrain in femur implants using the data generated through finite element simulation. Then, the ANN model is used as the surrogate model, which in combination with the desirability function serves as the objective function for optimization. The optimum achievable deviation was found to vary with the bone condition. The optimum implant geometry varied for different bone condition, and the findings act as guideline for designing patient-specific implant.


Assuntos
Fêmur/anatomia & histologia , Prótese de Quadril , Desenho de Prótese , Algoritmos , Feminino , Análise de Elementos Finitos , Humanos , Pessoa de Meia-Idade , Redes Neurais de Computação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...