Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Vasc Interv Radiol ; 30(6): 822-829.e4, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31031089

RESUMO

PURPOSE: To evaluate safety and effectiveness of the iCAST Covered Stent for treatment of iliac artery atherosclerotic lesions. MATERIALS AND METHODS: The iCARUS trial (ClinicalTrials.gov Identifier: NCT00593385) was a single-arm, prospective, multicenter study that enrolled 152 per protocol subjects at 25 sites in the United States and Germany. Subjects with multiple lesions and/or stents were eligible. The primary endpoint was the composite rate of death within 30 days, target lesion revascularization (TLR) within 9 months, or restenosis at 9 months after procedure. Secondary endpoints included major adverse vascular events (MAVEs), primary patency, freedom from TLR, and clinical success. RESULTS: Device and acute procedural success were achieved in 98.7% and 92.7% of cases, respectively. MAVE rate was 4.6% at 30 days. The 9-month primary composite endpoint rate was 8.1% (10/123), which was below the performance goal of 16.57%. Nine-month primary patency, defined as continuous flow without revascularization, bypass, or target limb amputation, was 96.4%. Freedom from TLR at 9 months and 3 years was 97.2% and 86.6%, respectively. Early clinical success was seen in 88.7% of subjects at 30 days with sustained clinical benefit in 72.4% of subjects at 3 years. CONCLUSIONS: The iCARUS study demonstrated that the iCAST Covered Stent was safe and effective for treatment of atherosclerotic iliac artery lesions with sustained clinical benefit out to 3 years.


Assuntos
Angioplastia com Balão/instrumentação , Artéria Ilíaca , Doença Arterial Periférica/terapia , Stents , Idoso , Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/mortalidade , Feminino , Alemanha , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/fisiopatologia , Intervalo Livre de Progressão , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Estados Unidos , Grau de Desobstrução Vascular
2.
JACC Cardiovasc Interv ; 10(23): 2349-2359, 2017 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-29216997

RESUMO

Significant progress has been made in the percutaneous coronary intervention technique from the days of balloon angioplasty to modern-day metallic drug-eluting stents (DES). Although metallic stents solve a temporary problem of acute recoil following balloon angioplasty, they leave behind a permanent problem implicated in very late events (in addition to neoatherosclerosis). BRS were developed as a potential solution to this permanent problem, but the promise of these devices has been tempered by clinical trials showing increased risk of safety outcomes, both early and late. This is not too dissimilar to the challenges seen with first-generation DES in which refinement of deployment technique, prolongation of dual antiplatelet therapy, and technical iteration mitigated excess risk of very late stent thrombosis, making DES the treatment of choice for coronary artery disease. This white paper discusses the factors potentially implicated in the excess risks, including the scaffold consideration and deployment technique, and outlines patient and lesion selection, implantation technique, and dual antiplatelet therapy considerations to potentially mitigate this excess risk with the first-generation thick strut Absorb scaffold (Abbott Vascular, Abbott Park, Illinois). It remains to be seen whether these considerations together with technical iterations will ultimately close the gap between scaffolds and metal stents for short-term events while at the same time preserving options for future revascularization once the scaffold bioresorbs.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Desenho de Prótese , Tomada de Decisão Clínica , Consenso , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/etiologia , Trombose Coronária/etiologia , Difusão de Inovações , Medicina Baseada em Evidências , Humanos , Seleção de Pacientes , Intervenção Coronária Percutânea/efeitos adversos , Falha de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
J Endovasc Ther ; 16(6): 665-75, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19995111

RESUMO

PURPOSE: To evaluate the safety and efficacy of a modified laser catheter designed for the endovascular treatment of peripheral artery disease (PAD) affecting the superficial femoral artery (SFA) and proximal popliteal artery. METHODS: The CliRpath Excimer Laser System to Enlarge Lumen Openings (CELLO) study was a single-arm, prospective registry conducted at 17 investigational sites in the United States. The primary endpoint was the reduction in index lesion percent diameter stenosis (% DS) measured by Doppler ultrasound following laser ablation prior to any adjunctive therapy. The primary safety endpoint was major adverse events at 6 months. Sixty-five patients (39 men; mean age 68.3+/-10.1 years) with intermittent claudication, stenotic lesions >70% by visual assessment, a reference vessel diameter >or=4.0 and or=1.0 and

Assuntos
Arteriopatias Oclusivas/terapia , Cateterismo Periférico/instrumentação , Artéria Femoral/fisiopatologia , Lasers de Excimer , Artéria Poplítea/fisiopatologia , Grau de Desobstrução Vascular , Idoso , Angioplastia com Balão , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/fisiopatologia , Cateterismo Periférico/efeitos adversos , Constrição Patológica , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/diagnóstico por imagem , Estudos Prospectivos , Radiografia , Recuperação de Função Fisiológica , Sistema de Registros , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler , Ultrassonografia de Intervenção , Estados Unidos , Caminhada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...