Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Microbiol Methods ; 152: 201-209, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29958908

RESUMO

The control of Legionella proliferation in cooling tower water circuits requires regular monitoring of water contamination and effective disinfection procedures. In this study, flow cytometry was assessed to monitor water contamination and disinfection treatment efficiency on bacterial cells regarding nucleic acid injury (SYBR® Green II), cell integrity (SYBR® Green II and propidium iodide) and metabolism activity (ChemChrome V6). A total of 27 cooling tower water samples were analyzed in order to assess water contamination levels regarding viable populations: standard culture, ATP measurement and flow cytometry methods were compared. Flow cytometry and plate counts methods showed a significant correlation for changes in concentrations despite a 1 to 2-log difference regarding absolute quantification. Concerning intracellular activity, the use of two different flow cytometers (FACSCanto™ II and Accuri™ C6) showed no statistical difference while a difference was observed between flow cytometry and usual methods (culture and ATP measurement). The standard culture and flow cytometry methods were also compared for in vitro bacteria inactivation measurements in the presence of 3 different types of oxidizing biocides commonly used for cooling tower disinfection. Reductions observed ranged between 1 and 2 log depending on (1) the detection method, (2) the bacterial population origin and/or (3) the active biocide molecule used. In conclusion, flow cytometry represents an efficient, accurate and fast approach to monitor water contamination and biocide treatment efficiency in cooling towers.


Assuntos
Desinfetantes/farmacologia , Citometria de Fluxo/métodos , Microbiologia da Água , Purificação da Água/métodos , Qualidade da Água , Trifosfato de Adenosina/análise , Bactérias/efeitos dos fármacos , Bactérias/metabolismo , Contagem de Colônia Microbiana , Desinfecção/métodos , Cinética , Legionella , Viabilidade Microbiana/efeitos dos fármacos , Hipoclorito de Sódio , Água , Poluição da Água
2.
Bioelectrochemistry ; 103: 65-73, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25216606

RESUMO

One of the different ways to eradicate microorganisms, and particularly bacteria that might have an impact on health consists in the delivery of pulsed electric fields (PEFs). The technologies of millisecond (ms) or microsecond (µs) PEF are still well known and used for instance in the process of fruit juice sterilization. However, this concept is costly in terms of delivered energy which might be too expensive for some other industrial processes. Nanosecond pulsed electric fields (nsPEFs) might be an alternative at least for lower energetic cost. However, only few insights were available and stipulate a gain in cost and in efficiency as well. Using Escherichia coli, the impact of frequency and low rate on eradication and energy consumption by msPEF, µsPEF and nsPEF have been studied and compared. While a 1 log10 was reached with an energy cost of 100 and 158 kJ/L with micro- and millisecond PEFs respectively, nsPEF reached the reduction for similar energy consumption. The best condition was obtained for a 1 log10 deactivation in 0.5h, for energy consumption of 143 kJ/L corresponding to 0.04 W · h when the field was around 100 kV/cm. Improvement can also be expected by producing a generator capable to increase the electric field.


Assuntos
Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Esterilização/métodos , Custos e Análise de Custo , Técnicas Eletroquímicas/economia , Desenho de Equipamento , Escherichia coli , Microbiologia da Água
3.
Conserv Biol ; 28(2): 315-21, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24405288

RESUMO

In Europe, bromadiolone, an anticoagulant rodenticide authorized for plant protection, may be applied intensively in fields to control rodents. The high level of poisoning of wildlife that follows such treatments over large areas has been frequently reported. In France, bromadiolone has been used to control water voles (Arvicola terrestris) since the 1980s. Both regulation and practices of rodent control have evolved during the last 15 years to restrict the quantity of poisoned bait used by farmers. This has led to a drastic reduction of the number of cases of poisoned wildlife reported by the French surveillance network SAGIR. During the autumn and winter 2011, favorable weather conditions and high vole densities led to the staging of several hundreds of Red Kites (Milvus milvus) in the Puy-de-Dôme department (central France). At the same time, intensive treatments with bromadiolone were performed in this area. Although no misuse has been mentioned by the authorities following controls, 28 Red Kites and 16 Common Buzzards (Buteo buteo) were found dead during surveys in November and December 2011. For all these birds, poisoning by bromadiolone as the main cause of death was either confirmed or highly suspected. Other observations suggest a possible impact of bromadiolone on the breeding population of Red Kites in this area during the spring 2011. French regulation of vole control for plant protection is currently under revision, and we believe this event calls for more sustainable management of rodent outbreaks. Based on large-scale experiments undertaken in eastern France, we propose that direct control of voles at low density (with trapping or limited chemical treatments) and mechanical destruction of vole tunnels, mole control, landscape management, and predator fostering be included in future regulation because such practices could help resolve conservation and agricultural issues.


Assuntos
4-Hidroxicumarinas/intoxicação , Arvicolinae , Conservação dos Recursos Naturais/métodos , Espécies em Perigo de Extinção , Falcões/metabolismo , Rodenticidas/intoxicação , Animais , Anticoagulantes/intoxicação , Conservação dos Recursos Naturais/legislação & jurisprudência , Política Ambiental , França , Estações do Ano
4.
Water Res ; 46(8): 2651-64, 2012 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-22421032

RESUMO

The removal of MS2, Qß and GA, F-specific RNA bacteriophages, potential surrogates for pathogenic waterborne viruses, was investigated during a conventional drinking water treatment at pilot scale by using river water, artificially and independently spiked with these bacteriophages. The objective of this work is to develop a standard system for assessing the effectiveness of drinking water plants with respect to the removal of MS2, Qß and GA bacteriophages by a conventional pre-treatment process (coagulation-flocculation-settling-sand filtration) followed or not by an ultrafiltration (UF) membrane (complete treatment process). The specific performances of three UF membranes alone were assessed by using (i) pre-treated water and (ii) 0.1 mM sterile phosphate buffer solution (PBS), spiked with bacteriophages. These UF membranes tested in this work were designed for drinking water treatment market and were also selected for research purpose. The hypothesis serving as base for this study was that the interfacial properties for these three bacteriophages, in terms of electrostatic charge and the degree of hydrophobicity, could induce variations in the removal performances achieved by drinking water treatments. The comparison of the results showed a similar behaviour for both MS2 and Qß surrogates whereas it was particularly atypical for the GA surrogate. The infectious character of MS2 and Qß bacteriophages was mostly removed after clarification followed by sand filtration processes (more than a 4.8-log reduction) while genomic copies were removed at more than a 4.0-log after the complete treatment process. On the contrary, GA bacteriophage was only slightly removed by clarification followed by sand filtration, with less than 1.7-log and 1.2-log reduction, respectively. After the complete treatment process achieved, GA bacteriophage was removed with less than 2.2-log and 1.6-log reduction, respectively. The effectiveness of the three UF membranes tested in terms of bacteriophages removal showed significant differences, especially for GA bacteriophage. These results could provide recommendations for drinking water suppliers in terms of selection criteria for membranes. MS2 bacteriophage is widely used as a surrogate for pathogenic waterborne viruses in Europe and the United States. In this study, the choice of MS2 bacteriophage as the best surrogate to be used for assessment of the effectiveness of drinking water treatment in removal of pathogenic waterborne viruses in worst conditions is clearly challenged. It was shown that GA bacteriophage is potentially a better surrogate as a worst case than MS2. Considering GA bacteriophage as the best surrogate in this study, a chlorine disinfection step could guaranteed a complete removal of this model and ensure the safety character of drinking water plants.


Assuntos
Bacteriófagos/isolamento & purificação , Água Potável/virologia , Levivirus/isolamento & purificação , Purificação da Água/métodos , Cloro/isolamento & purificação , França , Membranas Artificiais , Projetos Piloto , Rios/química , Soluções , Ultrafiltração , Inativação de Vírus , Purificação da Água/instrumentação , Qualidade da Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...