J Breath Res ; 18(1)2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38096565

RESUMO

Due to the overall low abundance of volatile compounds in exhaled breath, it is necessary to preconcentrate the sample prior to traditional thermal desorption (TD) gas chromatography mass spectrometry analysis. While certain aspects of TD tubes, such as volatile storage, have been evaluated, many aspects remain uncharacterized. Two common TD tubes, Tenax TA and Biomonitoring 5TD tubes, were evaluated for background content and flow rate variability. The data illustrate that the Biomonitoring 5TD tubes have the highest number (23) and abundance of background contamination greater than 3x the mean noise when compared to Tenax TA (13) and empty tubes (9). Tentative identifications of the compounds in the background contamination experiment show that greater than 59% (16/27) of the compounds identified have been reported in the breath literature. The data illustrate the TD tube background abundance could account for more than 70% of the chromatographic signal from exhaled breath for these select compounds. Flow rate measurements of 200 Tenax TA and 200 Biomonitoring 5TD tubes show a large range in measured flow rates among the TD tubes (Tenax: 252.9-284.0 ml min-1, 5TD: 220.6-255.1 ml min-1). Finally, TD tubes of each type, Tenax TA and Biomonitoring 5TD, previously established to have high, medium, and low flow rates, show insignificant differences (p> 0.05) among the tubes of different flow rates, using both gas standards and an exhaled breath from a peppermint experiment. Collectively, these results establish overall background compounds attributed to each TD tube type tested. Additionally, while measured flow rate variability is present and plausibly impacts exhaled breath results, the data demonstrate no statistically significant difference was observed between tubes showing high, medium, and low flow rates from two separate sample types.


Assuntos
Compostos Orgânicos Voláteis , Humanos , Compostos Orgânicos Voláteis/análise , Testes Respiratórios/métodos , Expiração , Cromatografia Gasosa-Espectrometria de Massas/métodos , Padrões de Referência
2.
J Breath Res ; 17(3)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37352843

RESUMO

Exhaled breath research has been hindered by a lack of standardization in collection and analysis methodologies. Recently, the Respiration Collector forIn VitroAnalysis (ReCIVA) sampling device has illustrated the potential to provide a consistent and convenient method for exhaled breath collection onto adsorbent media. However, the significant costs, compared to exhaled breath bags, associated with the standardized collector is believed to be the reason for limited widespread use by researchers in the exhaled breath field. For example, in addition to the sampling hardware, a single-use disposable silicon mask affixed with a filter is required for each exhaled breath collection. To reduce the financial burden, streamline device upkeep, reduce waste material, and ease the logistical burden associated with the single use masks, it is hypothesized that the consumable masks and filters could be sterilized by autoclaving for reuse. The masks were contaminated, autoclaved, and then tested for any surviving pathogens with spore strip standards and by measuring the optical density of cultures. The compound background collected when using the ReCIVA with new masks was compared to that collected with repeatedly autoclaved masks via thermal desorption gas chromatography mass spectrometry (TD-GC-MS). The capacity to block particulate matter of new filters was tested against that of autoclaved filters by introducing an aerosol and comparing pre-filter and post-filter particle counts. Finally, breath samplings were conducted with new masks and autoclaved masks to test for changes in measurements by TD-GC-MS of exogenous and endogenous compounds. The data illustrate the autoclave cycle sterilizes masks spiked with saliva to background levels (p= 0.2527). The results indicate that background levels of siloxane compounds are increased as masks are repetitively autoclaved. The data show that mask filters have significant breakthrough of 1µm particles after five repetitive autoclaving cycles compared to new filters (p= 0.0219). Finally, exhaled breath results utilizing a peppermint ingestion protocol indicate two compounds associated with peppermint, menthone and 1-Methyl-4-(1-methylethyl)-cyclohexanol, and an endogenous exhaled breath compound, isoprene, show no significant difference if sampled with a new mask or a mask autoclaved five times (p> 0.1063). Collectively, the data indicate that ReCIVA masks and filters can be sterilized via autoclave and reused. The results suggest ReCIVA mask and filter reuse should be limited to three times to limit potentially problematic background contaminants and filter dysfunction.


Assuntos
Testes Respiratórios , Esterilização , Humanos , Testes Respiratórios/métodos , Cromatografia Gasosa-Espectrometria de Massas , Expiração , Padrões de Referência
3.
J Breath Res ; 17(2)2023 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-36596256

RESUMO

Isoprene is one of the most abundant and most frequently evaluated volatile organic compounds in exhaled breath. Recently, several individuals with background levels of exhaled isoprene have been identified. Here, case study data are provided for an individual, identified from a previous study, with this low prevalence phenotype. It is hypothesized that the individual will illustrate low levels of exhaled isoprene at rest and during exercise. At rest, the subject (7.1 ppb) shows background (µ= 14.2 ± 7.0 ppb) levels of exhaled isoprene while the control group illustrates significantly higher quantities (µ= 266.2 ± 72.3 ppb) via proton transfer reaction mass spectrometry (PTR-MS). The result, background levels of isoprene at rest, is verified by thermal desorption gas chromatography mass spectrometry (TD-GC-MS) collections with the individual showing -3.6 ppb exhaled isoprene while the room background containedµ= -4.1 ± 0.1 ppb isoprene. As isoprene has been shown previously to increase at the initiation of exercise, exercise bike experiments were performed with the individual identified with low isoprene, yielding low and invariant levels of exhaled isoprene (µ= 6.6 ± 0.1 ppb) during the exercise while control subjects illustrated an approximate 2.5-fold increase (preµ= 286.3 ± 43.8 ppb, exerciseµ= 573.0 ± 147.8 ppb) in exhaled isoprene upon exercise start. Additionally, exhaled breath bag data showed a significant decrease in isoprene (delta post/pre, p = 0.0078) of the control group following the exercise regimen. Finally, TD-GC-MS results for exhaled isoprene from the individual's family (mother, father, sister and maternal grandmother) illustrated that the mother and father exhibited isoprene values (28.5 ppb, 77.2 ppb) below control samples 95% confidence interval (µ= 166.8 ± 43.3 ppb) while the individual's sister (182.0 ppb) was within the control range. These data provide evidence for a large dynamic range in exhaled isoprene in this family. Collectively, these results provide additional data surrounding the existence of a small population of individuals with background levels of exhaled isoprene.


Assuntos
Testes Respiratórios , Butadienos , Testes Respiratórios/métodos , Espectrometria de Massas/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Butadienos/análise , Hemiterpenos/análise , Expiração
4.
Front Chem ; 9: 659583, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34026725

RESUMO

Sweat is emerging as a prominent biosource for real-time human performance monitoring applications. Although promising, sources of variability must be identified to truly utilize sweat for biomarker applications. In this proof-of-concept study, a targeted metabolomics method was applied to sweat collected from the forearms of participants in a 12-week exercise program who ingested either low or high nutritional supplementation twice daily. The data establish the use of dried powder mass as a method for metabolomic data normalization from sweat samples. Additionally, the results support the hypothesis that ingestion of regular nutritional supplementation semi-quantitatively impact the sweat metabolome. For example, a receiver operating characteristic (ROC) curve of relative normalized metabolite quantities show an area under the curve of 0.82 suggesting the sweat metabolome can moderately predict if an individual is taking nutritional supplementation. Finally, a significant correlation between physical performance and the sweat metabolome are established. For instance, the data illustrate that by utilizing multiple linear regression modeling approaches, sweat metabolite quantities can predict VO2 max (p = 0.0346), peak lower body Windage (p = 0.0112), and abdominal circumference (p = 0.0425). The results illustrate the need to account for dietary nutrition in biomarker discovery applications involving sweat as a biosource.

5.
Talanta ; 223(Pt 1): 121797, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33303130

RESUMO

As the demand for real-time exercise performance feedback increases, excreted sweat has become a biosource of interest for continuous human performance assessment. For sweat to truly fulfill this requirement, analyte concentrations must be normalized to adequately assess day-to-day differences within and among individuals. In this manuscript, data are presented highlighting the use of accurate localized sweat rate as a means for ion and global metabolomic data normalization. The results illustrate large sweat rate variability among individuals over the course of two distinct exercises protocols. Furthermore, the data show sweat rate is not symmetrical at similar locations among right and left forearms of individuals (p = 0.0007). Sweat ion conductivity analysis suggest overall sweat rate normalization reduces variability collectively among ion values and participants with principal component analysis showing 77.8% of variation in the data set attributable to sweat rate normalization. Global metabolomic analysis of sweat illustrated overall rate normalization increases the variability among test subjects with 72.7% of the variation explained by sweat rate normalization. Finally, overall rate normalized metabolomic features of sweat significantly correlated (ρ ≥ 0.7, ρ ≤ -0.7) with measured performance metrics of the individual, establishing the potential for sweat to be used as a biosource for performance monitoring. Collectively, these data illustrate the importance of accurate localized sweat rate determination, for analyte data normalization, in support for the use of sweat in biomarker discovery efforts to predict human performance.


Assuntos
Metabolômica , Suor , Biomarcadores , Exercício Físico , Humanos , Análise de Componente Principal
6.
J Breath Res ; 14(3): 036004, 2020 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-32155613

RESUMO

The Respiration Collector for In Vitro Analysis (ReCIVA) sampler, marketed by Owlstone Medical, provides a step forward in exhaled breath sampling through active sampling directly onto thermal desorption (TD) tubes. Although an improvement to the issues surrounding breath bag sampling, the ReCIVA device, first released in 2015, is a relatively new research and clinical tool that requires further exploration. Here, data are presented comparing two distinct ReCIVA devices. The results, comparing ReCIVA serial numbers #33 and #65, demonstrate that overall statistically insignificant results are obtained via targeted isoprene quantitation (p > 0.05). However, when the data are parsed by the TD tube type used to capture breath volatiles, either Tenax TA or the dual bed Tenax/Carbograph 5TD (5TD), a statistical difference (p < 0.05) among the two different TD tubes was present. These data, comparing the two ReCIVA devices with both Tenax TA and 5TD tubes, are further supported by a global metabolomics analysis yielding 85% of z-scores, comparing ReCIVA devices, below the limit for significance. Experiments to determine the effect of breathing rate on ReCIVA function, using guided breathing for low (7.5 breaths min-1) and high (15 breaths min-1) breathing rates, demonstrate the ReCIVA device shows no statistical difference among breathing rates for quantitated isoprene (p > 0.05). Global metabolomics analysis of the guided breathing rate data shows more than 87% of the z-scores, comparing high and low breathing rates using both the Tenax and the 5TD tubes, are below the level for significance. Finally, data are provided from a single participant who displayed background levels of isoprene while illustrating levels of acetone consistent with the remaining participants. Collectively, these data support the use of multiple ReCIVA devices for exhaled breath collection and provide evidence for an instance where exhaled isoprene is consistent with background levels.


Assuntos
Testes Respiratórios/instrumentação , Manejo de Espécimes/instrumentação , Temperatura , Butadienos/análise , Expiração , Hemiterpenos/análise , Humanos , Masculino , Padrões de Referência , Compostos Orgânicos Voláteis/análise
7.
J Breath Res ; 14(1): 016009, 2019 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-31703231

RESUMO

Due to several sources of potential variability associated with exhaled breath bag sampling procedures for off-line analysis, the Respiration Collector for in vitro Analysis (ReCIVA) sampler was developed. Although designed to improve upon several pitfalls of sampling with exhaled breath bags, the ReCIVA remains a minimally studied research tool. In this manuscript, several attributes of the ReCIVA sampler are investigated among three individual tests, such as background contamination, control software version, performance of different adsorbent tubes, duplicate sample production, and comparison to exhaled breath bags. The data shows greater than a 58% reduction in background siloxanes can be achieved with submersion of ReCIVA masks in ethyl alcohol or baking the masks at a high temperature (200 °C). The results illustrate the ReCIVA control software version plays a key role in the flow rates applied to thermal desorption (TD) tubes. Using exhaled isoprene as a representative analyte, the data suggest duplicate samples among ReCIVA pump banks can be achieved using two different thermal desorption tubes, Tenax TA and Tenax/Carbograph 5TD, when using an updated control software and manually calibrating the ReCIVA pumps to uniform flow rates (Tenax p = 0.3869, 5TD p = 0.3131). Additionally, using the updated control software and manual ReCIVA flow calibration, the data suggest the ReCIVA can produce statistically similar results among TD tube types (p = 0.3824) and compared to standard exhaled breath bags (p = 0.1534). Collectively, these results establish a method for manually calibrating the flow of the ReCIVA device to allow for the most consistent results. These data support further experimentation into the use of the ReCIVA sampler for exhaled breath research.


Assuntos
Testes Respiratórios/métodos , Butadienos/análise , Calibragem , Expiração , Hemiterpenos/análise , Humanos , Masculino , Padrões de Referência , Siloxanas/química , Manejo de Espécimes