Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vasc Surg ; 46(5): 891-6; discussion 896-7, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17980275

RESUMO

BACKGROUND: It is commonly assumed that the aortic wall deforms uniformly and has uniform wall thickness about the circumference. The purpose of this study was to evaluate the aortic wall motion and thickness in the infrarenal aortic neck of patients with abdominal aortic aneurysms who were undergoing endovascular repair (EVAR) and to compare the dynamic measurements of intravascular ultrasonography with the static measurements of computed tomographic angiography (CTA). METHODS: A total of 25 patients were evaluated before surgery with CTA and three-dimensional reconstructions on a Vitrea workstation, followed by intraoperative assessment of the proximal aortic neck with intravascular ultrasonography (IVUS) before EVAR. Infrarenal aortic neck dimensions on CTA were obtained at 1-mm intervals, but for the purposes of this study all dimensions on CTA were obtained 1 cm below the lowest renal artery. IVUS analysis of the proximal aortic neck was obtained with a 10-second recorded data loop of aortic wall motion. A Digital Imaging and Communications in Medicine viewer was used to view the recorded loop of aortic movement, and each image was captured and then evaluated with a SCION PCI Frame Grabber to determine aortic dimensions and wall thickness. IVUS diameters (250 measurements of each aorta) were recorded through a full continuous cardiac cycle from the epicenter of the lumen (maintaining the left renal vein in its normal anatomic configuration) in an anteroposterior (AP) direction in the area of greatest wall movement and 90 degrees perpendicular to this direction (lateral movement). RESULTS: There was significant variation in infrarenal aortic wall movement about the circumference, with 1.7 +/- 0.6 mm (range, 0.6-2.7 mm) displacement in the AP direction and 0.9 +/- 0.5 mm (range, 0.3-1.5 mm) displacement in the lateral direction (P < .001). Aortic wall thickness was greater in the region of increased AP wall motion than in the area of lesser lateral wall motion (2.3 +/- 0.6 mm vs 1.2 +/- 0.3 mm; P < .001). There was no difference between the IVUS and CTA aortic neck measurements (25.5 vs 25.6 mm; not significant) during the midpoint of the cardiac cycle of IVUS. However, at peak systole, IVUS recorded a greater diameter than CTA (26.4 vs 25.6 mm; P < .001), and at end-diastole, IVUS recorded a smaller diameter than CTA (24.7 vs 25.6 mm; P = .01). CONCLUSIONS: The infrarenal neck of aortic aneurysms deforms anisotropically during the cardiac cycle. The greatest displacement is in the AP direction and corresponds with a significantly greater wall thickness in this area. The magnitude of cyclic change in aortic diameter can be as high as 11%. Further evaluation of proximal aortic neck wall motion after EVAR is warranted to determine the interaction of various stent designs and the aortic wall.


Assuntos
Aorta/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/patologia , Ultrassonografia de Intervenção , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Humanos , Fluxo Pulsátil , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...