Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Aust J Rural Health ; 15(3): 183-8, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17542791

RESUMO

OBJECTIVE: Review of dementia screening case profiles that included brain blood flow imaging to determine contribution to diagnosis. DESIGN: Retrospective medical case audit. SETTING: Rural New South Wales. PARTICIPANTS: Eighty-eight rural patients who underwent investigations for dementia diagnosis. MAIN OUTCOME MEASURE: Contribution of brain blood flow imaging (single photon emission tomography, SPECT) to the dementia screening regime. RESULTS: The age range of those referred was 21-88 years, the average being 70 years. There were 44 men and 44 women. Vascular causes of dementia accounted for 27% of all those referred for brain blood imaging. Senile dementia of the Alzheimer's type accounted for 40% of all referrals. The occurrence of mixed disease was 6%. Matching neuropsychological reports and computer tomography were available for 18 of the blood flow studies. Of these, 65% were in agreement or semi-agreement for the diagnostic outcome. Only five studies failed to reach consensus. GPs were responsible for 31% of the imaging referrals, and the remaining referrals were from the regions: two gerontologists, three physicians and two neurologists. CONCLUSIONS: Brain blood flow imaging did contribute to the final diagnosis of dementia type for these patients, influencing patient management.


Assuntos
Demência/diagnóstico , Programas de Rastreamento/organização & administração , Serviços de Saúde Rural/organização & administração , Tomografia Computadorizada de Emissão de Fóton Único/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Viés , Causalidade , Demência/classificação , Demência/epidemiologia , Diagnóstico Diferencial , Medicina de Família e Comunidade , Feminino , Humanos , Masculino , Auditoria Médica , Entrevista Psiquiátrica Padronizada , Pessoa de Meia-Idade , Testes Neuropsicológicos , New South Wales/epidemiologia , Avaliação de Programas e Projetos de Saúde , Encaminhamento e Consulta , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Tomografia Computadorizada por Raios X
2.
Nucl Med Commun ; 25(10): 1039-48, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15381872

RESUMO

BACKGROUND: The efflux rate of technetium-99m Sestamibi (99mTc-Sestamibi) is a kinetic phenomenon related to the response of cancer cells to chemotherapy, and may be used to determine drug resistance. Measurement of the efflux rate requires accurate quantitative single-photon emission tomography (SPET) imaging within the time constraints imposed by the kinetics of the process. METHODS: A phantom study, at activity concentrations typically found with 99mTc-Sestamibi in vivo, was undertaken to optimize the SPET parameters and, in particular, to determine whether 180 degrees acquisition arcs with heads in 'L' configuration could be used for accurate quantification. Following the development of the most appropriate SPET protocol, a small patient pilot study was undertaken. RESULTS: Studies designed to evaluate statistical uncertainty (noise), contrast restitution and spatial resolution of the data sets, using different acquisition and reconstruction parameters, showed that 180 degrees SPET using a 64 x 64 matrix, 6 degrees angular sampling and iterative reconstruction was optimal. Finer linear and/or angular sampling afforded negligible improvement in resolution, but markedly increased the statistical uncertainty. Comparison of 360 degrees and 180 degrees acquisitions, utilizing conventional filtered backprojection and iterative reconstruction algorithms, demonstrated that the statistical uncertainty was reduced to a greater extent for 180 degrees data collection. For 360 degrees (64 x 64) data acquisition, statistical uncertainty decreased from 15% to 11% using the iterative algorithm, whilst the 180 degrees (64 x 64) data showed a reduction from 20% to 7%, and approached values obtained by planar imaging. The efflux measurements obtained in the patient pilot study were consistent with the observed chemotherapy response. CONCLUSION: Our study shows that 180 degrees acquisition arcs are a practical option for accurate quantitative SPET kinetic imaging for potential studies of chemotherapy response in patients with lung cancer.


Assuntos
Resistência a Múltiplos Medicamentos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/tratamento farmacológico , Neoplasia Residual/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Algoritmos , Antineoplásicos/uso terapêutico , Humanos , Imagens de Fantasmas , Projetos Piloto , Garantia da Qualidade dos Cuidados de Saúde/métodos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA