Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(18)2022 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-36146393

RESUMO

The adverse health effects of the presence of lead in wastewater streams are well documented, with conventional methods of lead recovery and removal suffering from disadvantages such as high energy costs, the production of toxic sludge, and low lead selectivity. Klebsiella pneumoniae and Paraclostridium bifermentans have been identified as potential lead-precipitating species for use in a lead recovery bioreactor. Electrical impedance spectroscopy (EIS) on a low-cost device is used to determine the potential for the probe-free and label-free monitoring of cell growth in a bioreactor containing these bacteria. A complex polynomial is fit for several reactive equivalent circuit components. A direct correlation is found between the extracted supercapacitance and the plated colony-forming unit count during the exponential growth phase, and a qualitative correlation is found between all elements of the measured reactance outside the exponential growth phase. Strong evidence is found that Pb(II) ions act as an anaerobic respiration co-substrate for both cells observed, with changes in plated count qualitatively mirrored in the Pb(II) concentration. Guidance is given on the implementation of EIS devices for continuous impedance monitoring.


Assuntos
Esgotos , Águas Residuárias , Bactérias , Espectroscopia Dielétrica/métodos , Impedância Elétrica , Chumbo , Esgotos/microbiologia
2.
Sensors (Basel) ; 21(19)2021 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-34641015

RESUMO

Impedance spectroscopy is a widely used electrochemical technique with a wide variety of applications. Many of these applications benefit from the additional accessibility provided by low-cost impedance devices. With this in mind, a low-cost impedance device was designed for a high performance-to-cost ratio. The performance of this analyzer was validated against a high-performance DropSens µStat-i 400s potentiostat by performing an application-based experiment. Nitrate detection provides a relevant experiment because of the importance of maintaining precise nitrate concentrations to mitigate the impact of nitrate fluctuations on the environment. Dissolved nitrate samples of different concentrations, in the range 3-1000 mg/L, were confirmed colorimetrically and measured with both instruments. A calibration curve of the real impedance matched a sigmoidal transfer, with a linear region for concentrations below 10 mg/L. The device under investigation exhibited an average magnitude error of 1.28% and an average phase error of 0.96∘ relative to the high-performance standard, which validates the performance of the low-cost device. A cost analysis is presented that highlights some of the complexities of cost comparisons.


Assuntos
Espectroscopia Dielétrica , Nitratos , Calibragem , Impedância Elétrica , Técnicas Eletroquímicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...