Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 172
Filtrar
1.
Int J Prosthodont ; 37(1): 34-40, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-37222543

RESUMO

PURPOSE: To compare the fit and fracture load of temporary fixed partial prostheses fabricated by means of a conventional direct technique, milling, or 3D printing. MATERIALS AND METHODS: A maxillary right first premolar and molar were prepared on a Frasaco cast, which was then duplicated 40 times. In total, 10 provisional three-unit fixed prostheses (Protemp 4, 3M) were made using the conventional technique with a putty mold. The 30 remaining casts were scanned to design a provisional restoration using CAD software. A total of 10 designs were milled (CEREC MC X5/shaded PMMA Disk, Dentsply Sirona), while the other 20 were 3D printed with one of the two 3D printers (Asiga UV MAX or Nextdent 5100, C&B, Nextdent). Internal and marginal fit were examined using the replica technique. Next, the restorations were cemented on their respective casts and loaded until fracture using a universal testing machine. The location and propagation of the fracture were also evaluated. RESULTS: 3D printing demonstrated the best internal fit. Nextdent (median internal fit: 132 µm) was significantly better compared to the milled (median internal fit: 185 µm; P = .006) and conventional restorations (median internal fit: 215 µm; P < .001), while the fit of Asiga (median internal fit: 152 µm) was only significantly better than the conventional restorations (P < .012). The lowest marginal discrepancy was found for the milled restorations (median marginal fit: 96 µm), but this was only significant when compared to the conventional group (median internal fit: 163 µm; P < .001). The conventional restorations demonstrated the lowest fracture load (median fracture load: 536 N), which was only significant when compared to Asiga (median fracture load: 892 N; P = .003). CONCLUSIONS: Within the present in vitro study's limitations, CAD/CAM demonstrated superior fit and strength compared to the conventional technique.


Assuntos
Implantes Dentários , Planejamento de Prótese Dentária , Planejamento de Prótese Dentária/métodos , Adaptação Marginal Dentária , Desenho Assistido por Computador , Impressão Tridimensional , Coroas
2.
J Clin Med ; 12(13)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37445465

RESUMO

(1) Although the accuracy of static computer-aided implant surgery (sCAIP) is well reported, information on its long-term effect on peri-implant health and complications is scarce. (2) Twenty-six patients initially treated were recalled. Implant survival, radiographic bone level, peri-implant health, and complications were registered. A multilevel regression model was applied to study the relationship between the research variables. (3) Sixteen patients participated in this study (average age 58.5 years; range 27.8-73.8). The mean follow-up time was 9.1 years (range 7.3-11.3). Two implants failed, resulting in a survival rate of 97.1%. The mean bone level change corresponded to a loss of 0.63 mm (SD 1.90) for the whole group, 0.17 mm (SD 1.46), and 0.91 mm (SD 2.09) for tooth- and mucosa-supported guides, respectively. The mean PPD for the total group was 4.24 mm (SD 1.25), and 3.79 mm (SD 0.97) and 4.51 mm (SD 1.33) for the tooth- and mucosa-supported guides, respectively. Four implants (6.3%) were diagnosed with peri-implantitis. Coronal deviation was slightly associated with having a negative impact on bone level at follow-up, but this was not statistically significant. Seven patients (43.8%) experienced technical complications. Biological complications were seen in 3/16 patients (18.75%). (4) SCAIP may contribute to more predictable implant placement; the long-term clinical outcome is similar to conventional nonguided surgery.

3.
J Clin Med ; 12(11)2023 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-37297870

RESUMO

BACKGROUND: Long-term follow-up of single implants and crowns is scarce, especially when inserted using flapless surgery. AIM: Evaluate survival, peri-implantitis incidence, and technical/biologic complications of solitary implants/crowns after 10-12 years of function. MATERIAL AND METHODS: 49 patients with 53 single implants, initially operated with a one-stage flap (F) or flapless (FL) surgery and delayed loading, were recalled. Implant survival, radiographic bone-level changes compared to baseline, peri-implant health, and soft tissue aesthetics were registered. Differences in implant level between and within groups were statistically tested using the Mann-Whitney U-Test and Wilcoxon Signed Ranks Test, respectively. RESULTS: 36 patients with 40 implants were reassessed, yielding 100% implant and 97.5% crown survival. The bone loss in F (n = 19) was 0.56 mm (SD 0.89; range -0.9-2.02) and -0.85 mm (SD 0.98; range -2.84-0.53) in FL (n = 21), indicative of bone gain in FL (p = 0.003), the latter due to a difference at baseline but bone-level was comparable (p = 0.126). Groups were comparable for probing pocket depth (PPD); (3.32 vs. 3.19 mm), Bleeding Index (BI); (0.15 vs. 0.22), and gingival recession; (0.38 vs. 0.17 mm). According to international criteria, the peri-implantitis incidence was 0%, but 32.5% of the implants/crowns experienced biological or technical complications irrespective of surgical technique. CONCLUSIONS: Solitary implants and crowns show good long-term clinical outcomes and peri-implant health. Flapless surgery is a good alternative to conventional in straightforward cases with sufficient bone volume and proper treatment planning.

4.
Clin Implant Dent Relat Res ; 25(5): 829-839, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37309711

RESUMO

BACKGROUND: The long-term clinical outcome of mini dental implants (MDIs) to support an overdenture is underreported especially in severely atrophic maxillae and when installed flaplessly. PURPOSE: The current report is a 5-years follow-up of the previously published 2- and 3-years clinical outcome of MDIs supporting a maxillary overdenture in narrow alveolar ridges. MDI survival, marginal bone level, peri-implant health, technical complications, and oral health related quality of life (OHIP) and respective changes over time are reported. MATERIALS AND METHODS: Subjects aged 50 years or older, in need of improvement of maxillary denture retention, were included. The MDIs were 2.4 mm diameter one-piece tapered implants, Class 4 pure Titanium, and lengths 10 or 11.5 mm. Under local anesthesia, 5-6 MDIs were placed in atrophic maxillae with a free-handed flapless approach. One week postoperative the denture was adapted with a retentive soft reliner. The final prosthetic connection was established after 6 months with a metal-reinforced horse-shoe denture. Clinical outcome after 5 years was assessed with probing pocket depts (PPD), bleeding on probing (BoP), and additional cone beam computed tomography (CBCT) MDI bone level measurements were performed. Oral Health-Related Quality of Life (OHRQoL) investigated with OHIP-14 was assessed preoperative, during provisional loading, and after final prosthetic connection up to 5 years. RESULTS: Initially, 31 patients (14 females and 17 males) with mean age 62.30 underwent treatment. In the provisional loading interval, 16 patients encountered 32/185 MDIs failures, resulting in a failure of 17.3%; 170 MDIs were functionally loaded in 29 patients. Additionally, 14 implants were lost in three patients, all of whom had had already previous failures. Reimplantation of 17 MDIs were performed during the provisional loading and 2 MDI after functional loading. After 5 years, the absolute implant failure rate was 46/204 (22.5%), corresponding to a cumulative failure rate of 23.2%. Prosthetic failure was observed in four patients due to implant loss and in two patients related to excessive one-piece implant ball attachment wear, making the 5-years prosthetic success 80.0%. The mean PPD and absence/presence of BoP for 149 implants at 5 years was 4.3 and 0.2 mm, respectively. Average mesial-distal-vestibular-palatal bone loss in the interval 2-5 years was 0.08 mm. No statistically significant difference in marginal MDI bone loss between male or female (p = 0.835), smoking and nonsmoking (p = 0.666) was observed. The five-years total measured CBCT interdental bone level (mesial and distal) correlates with the 5-years PPD (Pearson 0.434; p = 0.01). After 5 years, OHRQoL with the treatment procedure was assessed in 27/31 participants. Decreasing mean total OHIP-14 scores with improved OHRQoL, was observed in 27/31 participants, with values of 21.3 at baseline to 15.6 at the time of provisional loading which significantly (p = 0.006) decrease to 7.3 at the final prosthetic connection. The next 3-5 years further decrease was observed with 6.5 and 4.96, respectively. CONCLUSIONS: Maxillary MDIs for overdentures are an accessible and acceptable treatment option. Although after 5 years between one fifth and one fourth of the MDIs were lost, prosthetic success remains 80.0% and high OHRQoL could be achieved.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Revestimento de Dentadura , Maxila/cirurgia , Estudos de Coortes , Estudos Prospectivos , Qualidade de Vida , Perda do Osso Alveolar/etiologia , Prótese Dentária Fixada por Implante/efeitos adversos , Resultado do Tratamento , Falha de Restauração Dentária
5.
Artigo em Inglês | MEDLINE | ID: mdl-36661886

RESUMO

The aim of current split-mouth study was to compare the implant treatment outcomes of hybrid-surface implants (minimally rough implant collar and moderately rough body) with moderately rough implants after 5 years in patients with a bar-supported mandibular overdenture. Fully edentulous patients were enrolled, and each patient received two implants: one moderately rough and one hybrid-surface implant. A total of 18 patients with 36 implants attended the 5-year recall, and the implant survival rate was 100%. The 5-year evaluation showed no significant difference in crestal bone loss or peri-implant health between the hybrid and moderately rough implants.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Arcada Edêntula , Humanos , Implantação Dentária Endóssea , Perda do Osso Alveolar/cirurgia , Arcada Edêntula/cirurgia , Planejamento de Prótese Dentária , Resultado do Tratamento , Revestimento de Dentadura , Prótese Dentária Fixada por Implante
6.
Artigo em Inglês | MEDLINE | ID: mdl-36305928

RESUMO

Mini dental implants (MDIs) are an affordable alternative for overdentures in medically compromised patients with reduced bone volume. This human study reports the histomorphometric analysis of early loaded and flaplessly placed tapered, one-piece MDIs (ILZ, Southern Implants; Sa: 1.5 µm) after 7 to 11 months in function. Patients agreed to have an additional MDI placed and removed for evaluation. MDI stability was assessed via Periotest prior to implant removal. Histologic sections of four mandibular and three maxillary MDIs with surrounding bone were processed, and the bone-to-implant contact (BIC) was analyzed. At retrieval, the MDIs were in function for more than 6 months, were clinically healthy, and had mean probing pocket depths of 1.4 mm and 1.6 mm in the maxilla and mandible, respectively. Periotest values were < 5.5, indicating clinical stability. Most of the screw threads were filled with bone and revealed an intimate BIC, without any signs of intervening fibrous tissue layer. In both arches, the mean BIC was 68.5%. Large osteocytes could be identified in the calcified tissue, indicative of mature peri-implant bone. It can be concluded that MDIs, when loaded within 2 weeks in either arch, provide proper clinical stability and high BIC after 6 months.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Humanos , Mandíbula/cirurgia , Maxila/cirurgia , Prótese Dentária Fixada por Implante , Osseointegração , Planejamento de Prótese Dentária , Implantação Dentária Endóssea
7.
J Clin Med ; 11(15)2022 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-35956252

RESUMO

BACKGROUND: Flaplessly placed one-piece mini dental implants (MDI) are an option to support maxillary overdentures. Evenly distribution of the implants over the atrophic alveolar process implies a risk of accidental sinus perforation in the posterior area which could induce sinus-related pathology. METHODS: Thirty-one patients received 5-6 maxillary MDIs. Schneiderian membrane swelling was assessed with CBCT at the deepest point of the sinus in the mid-sagittal plane prior to surgery (baseline), after 2 and 5 years. Additionally, subjective patient-reported rhinosinusitis complaints, the effect of smoking, and gender differences were investigated. RESULTS: Mean thickness of the Schneiderian membrane was 2.87 mm at baseline, 3.15 mm at 2 years, and 4.30 mm at 5 years in 27 of 31 initially treated patients. MDI perforation was detected in 21/54 sinuses. At 2 years, perforation length does not affect membrane thickness whereas baseline swelling does. In smokers, each perforated mm induced 0.87 mm additional swelling. After 5 years, the effect of baseline swelling becomes smaller whereas perforation length became statistically significant, with 0.53 mm increase for every perforated mm. The effect of smoking lost its significance. No relations between gender, membrane thickness changes, or subjective clinical sinus complaints and MDI perforation were found. CONCLUSION: Accidental MDI sinus perforation induces Schneiderian membrane swelling but does not interfere with clinical sinusal outcome after 5 years.

8.
Int J Oral Maxillofac Implants ; 37(3): 479-484, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35727238

RESUMO

PURPOSE: The increasing popularity of desktop 3D printers makes guided surgery more accessible. The aim of this in vitro study was to evaluate the accuracy of single-tooth guided implant surgery by means of a 3D-printed tooth-supported guide. MATERIALS AND METHODS: Fifteen implants were virtually planned to replace a missing first mandibular molar, using planning software for guided implant surgery (Exoplan, Exocad). A tooth-supported guide was designed and manufactured using a desktop 3D printer (Asiga MAX UV). The implants were placed fully guided in resin casts, and a digital impression was taken to register their position. This scan was compared with the virtual implant position in the planning software, and the internal fit of the guides was evaluated using metrology software. One planning was executed six times for measuring precision. RESULTS: For trueness, the mean angular deviation was 2.63 degrees (SD: 1.69 degrees; range: 0.38 to 5.99 degrees), the mean coronal deviation was 0.52 mm (SD: 0.25; range: 0.09 mm to 1.07 mm), and the mean apical deviation was 0.90 mm (SD: 0.47; range: 0.14 to 1.74 mm). The absolute apical mean deviation in the buccolingual direction (x-axis) was 0.70 mm (SD: 0.42, 0.12 to 1.65 mm; P < .001); in the mesiodistal direction (y-axis), it was 0.34 mm (SD: 0.26; range: 0.01 to 0.80 mm; P = .650); and in the vertical direction (z-axis), it was 0.32 mm (SD: 0.27; range: 0.02 to 1.00 mm; P = .010). The mean internal fit of the guides was 79.5 µm (SD: 19.6 µm; range: 51 to 118 µm). CONCLUSION: Desktop 3D-printed tooth-supported guides demonstrate an acceptable fit and acceptable level of accuracy for single implant placement.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Imageamento Tridimensional , Impressão Tridimensional
9.
Int J Prosthodont ; 35(3): 259-268, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35727259

RESUMO

PURPOSE: To evaluate the success of monolithic endocrowns fabricated using a digital workflow. MATERIALS AND METHODS: Twenty-three patients requiring restoration of devitalized molars or premolars were included in the study. The preparation was scanned using an intraoral scanner (Cerec Bluecam, Dentsply Sirona), and a monolithic restoration was made from a nanoparticle resin-based hybrid composite (#10 Cerasmart [CS]; #10 Lava Ultimate [LU], 3M Espe) or a polymer-infiltrated ceramic (#10 Vita Enamic [VE]). At the time of placement and after 6 months, 1 year, and 5 years of function, radiographs were taken to evaluate the marginal integrity of the restorations, and clinical pictures were taken to assess the quality of the restoration using the USPHS criteria. RESULTS: After 5 years, the restorative success rate was 70.8%, the restorative survival rate was 87.5%, and the tooth survival was 91.6%. Four chippings (two LU, two CS), three fractures (three LU), and two debonding of the restorations (two CS) occurred. Also, two teeth were extracted after 5 years of follow-up (two VE) because of secondary caries and a root fracture. The USPHS ratings were high, except for color match, which was rated the lowest at all time intervals. CONCLUSION: Nanoceramic endocrowns made using a completely digital workflow have an acceptable survival rate after 5 years. However, the complication rate was high.


Assuntos
Porcelana Dentária , Planejamento de Prótese Dentária , Cerâmica , Resinas Compostas , Desenho Assistido por Computador , Materiais Dentários , Falha de Restauração Dentária , Humanos , Teste de Materiais , Estudos Prospectivos , Fluxo de Trabalho
10.
Dent J (Basel) ; 10(5)2022 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-35621541

RESUMO

Denture wearers often complain about jeopardized function and reduced quality of life due to lack of prosthesis' retention. Implant-retained mandibular overdentures, on two non-connected implants (2IOD) are well-proven solutions to overcome these issues. We prospectively assessed 69 patients and scrutinized clinical records until at least seven years of function. Thirty-six were retained on Locator® Abutments (LA) and thirty-tree on Ball Abutments (BA). Both systems were compared regarding the type, amount, and total cost of required maintenance. One implant was lost, yielding 98.7% survival after seven years. In total, 438 technical issues occurred: 121 (27.35%) in BA and 317 (72.4%) in LA. Out of these, 343 events (78%) were solved chairside: 191 (43.6%) were replacements of retention caps, 113 (25.8%) were minor acrylic repairs, 26 (5.9%) pressure ulcers had to be relieved, and 13 (3%) were related to abutments. LA required 179 insert replacements compared to 12 in the BA group. The overall initial treatment cost was EUR 3850 (base year of the analysis: 2003). The average total maintenance cost in relation to the initial cost for the LA and BA groups was 19.11 (range 0-82.24%) and 18.91% (range 0-113.26%) respectively (p = 0.540). Conclusions: The seven-year maintenance costs for a 2IOD is acceptable when the patient is regularly checked and professionally maintained. Most events are easily solvable chairside, but a few patients required more expensive interventions, regardless of the type of attachment used.

11.
J Clin Med ; 11(8)2022 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-35456347

RESUMO

(1) Long-term data on maxillary implant overdentures (IODs) are scarce. This case series evaluated three types of IODs supported by six, four or three implants (Anyridge®, Mega'Gen Implant Co., Ltd., Daegu, South-Korea), after 3-5 years in function. (2) A total of 31 patients, with 132 implants, were non-randomly allocated based on available bone or financial limitations. IOD-6 received a telescopic overdenture; IOD-4 a bar; and IOD-3, non-connected implants with locator abutments. Implant survival, bone level changes, probing pocket depth (PPD), plaque index, bleeding on probing (BOP), and technical, biological and aesthetic complications were registered. Impact of suprastructures on bone loss and PPD was analyzed using mixed-effect linear regression models. Differences between groups were analyzed using the ANOVA test for BOP, and Kruskal Wallis test for complications. (3) In total, 23 patients participated in the follow-up (9 female, 14 male), with average age of 62.2 years; 7, 11 and 5 patients in IOD-6, IOD-4 and IOD-3, respectively. Implant survival after 4.4 years on average, was 98% in total; 100%, 97.8% and 93.3% for IOD-6, IOD-4 and IOD-3, respectively. Mean bone loss corresponded to 0.68 mm (SD 1.06, range -4.57-1.51), 0.39 mm (SD 1.06, range -3.6-2.43), and 1.42 mm (SD 1.68, range -5.11-0.74) for IOD-6, IOD-4 and IOD-3, respectively. A statistically significant difference was seen in bone level when comparing IOD-6 to IOD-3 (p = 0.044), and IOD-4 to IOD-3 (p = 0.018). Mean PPD was 3.8 mm (SD: 0.69; range 2.5-5.3), 3.5 mm (SD 0.59; range 2.33-5), and 3.2 mm (SD 0.56; range 2-4) for IOD-6, IOD-4 and IOD-3, respectively, and differed significantly between IOD-6 and IOD-3 (p = 0.029). Incidence of peri-implantitis was 1%. No differences were seen for complications between groups. (4) Maxillary IOD supported by four to six implants is the most reliable treatment regarding implant survival and peri-implant health. More research is needed in the clinical outcomes, in particular the peri-implant health, and complications of maxillary IODs, especially with a reduced number of implants.

12.
J Clin Med ; 10(21)2021 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-34768527

RESUMO

BACKGROUND: Mini dental implant (MDI) overdenture rehabilitation for the edentulous maxilla is a valuable, less invasive and affordable treatment alternative for complete removable dentures (CRD). However, comparative quantification of masticatory performance in different oral conditions are scarce. PURPOSE: This study compares objective masticatory performance of dentate groups, maxillary CRD and MDI overdentures and subjective masticatory performance in maxillary CRD and MDI overdentures. MATERIALS AND METHODS: Four groups were defined, age 20+ dentate dental students (DS), age 50+ complete dentate subjects (DP), age 50+ maxillary CRD or MDI overdentures/dentate mandible. Objective masticatory performance was evaluated by measuring circular Variance of Hue (VOH) or the mixture degree of two-color chewing gum (Hue-check View Gum® Test). Additionally, subjective masticatory comparison was investigated in the CRD and MDI groups, with a visual analogue scale (VAS) for different food consistencies and the Oral Health Related Quality of Life (OHRQL) OHIP-14 questionnaire. RESULTS: The mean VOH was 0.11 (SD 0.50, range 0.05-0.27) for the dentate dental 20+ students, 0.13 (SD 0.08, range 0.03-0.31) for the 50+ dentate group (p = 0.774), 0.41 (SD 0.41, range 0.14-0.76) for the CRD group and 0.39 (SD 0.18, range 0.07-0.76) for the MDI group (p = 0.725). Based on the VAS scores, no improvement was found between the CRD and the MDI overdenture group (p > 0.050). The mean OHIP-14 total score was 12.10 (SD 15.87, range 0-56) for CRD, while the MDI group (p = 0.039) saw a significant improvement to 2.85 (SD 2.85, range 0-15). CONCLUSION: Comparable results in objective masticatory performance were registered in dentate 20+ and 50+ subjects with a remarkable inferior outcome for the CRD and MDI group. Compared to CRD, MDI overdentures revealed no substantial improvement in subjective and objective masticatory performance. However, for MDI a significant increase in OHRQL was apparent.

13.
Clin Implant Dent Relat Res ; 23(5): 671-679, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34378860

RESUMO

BACKGROUND: According to literature, peri-implant bone loss is minimized on implants with microthreaded neck design and internal type of abutment connection. However, most clinical studies may be biased due to confounding factors. PURPOSE: This nonblinded RCT assessed the effect of implant neck (microthreaded vs non-microthreaded) as well as the type of abutment connection (internal conical vs external flat-to-flat) on peri-implant bone stability and peri-implant health after at least 36 months. MATERIALS AND METHODS: Twenty-five patients were treated with a maxillary implant-supported bar-retained overdenture on four different implant types: internal connection with microthreads (I-MT), internal connection without microthreads (I-NMT), external connection with microthreads (E-MT), and external connection without microthreads (E-NMT). To control confounding factors, all other design features were similar. A linear mixed-model analysis or mixed-model logistic regression analysis was used to determine the effect of implant type on bone level, probing pocket depth, bleeding on probing, and plaque. RESULTS: Four out of 98 implants (4.1%) placed in 25 patients failed during provisionalization and were replaced. Mean overall bone loss after 6 months was 0.39 mm (SD 0.62, range 0.00-3.48) with limited additional bone loss of 0.04 mm (SD 0.54, range -1.80-1.63) after at least 3 years. Microthreads or connection type had no effect on the bone level, probing pocket depth, bleeding on probing, nor plaque. CONCLUSIONS: With 96% of implant survival, the maxillary overdenture supported with a bar on four implants yield a predictable outcome and the implant-abutment connection type (internal vs external) and implant neck design (microthreaded vs non-microthreaded) have no influence on peri-implant bone remodeling after initial bone remodeling nor up to 4 years of function. Peri-implant bone levels are within international success standards and peri-implant health is indicative of absence of peri-implantitis.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/etiologia , Implantação Dentária Endóssea , Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Humanos , Maxila/cirurgia
14.
Clin Implant Dent Relat Res ; 23(5): 680-691, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34378864

RESUMO

BACKGROUND: Implant-supported overdentures (IOD) are becoming a more commonly used treatment in the dental practice and it risks causing speech problems. PURPOSE: The aim of this study was investigating the changes in speech, satisfaction with speech, and overall oral health-related quality of life (OHRQoL) in edentulous patients during and after treatment with maxillary IODs. MATERIALS AND METHODS: Twenty-one patients receiving an IOD participated in speech assessment. They were examined preoperatively with their conventional denture (CD) with full palatal coverage, after connection of the implant-bar connected denture, without palatal coverage, and 3 years thereafter. The examination included assessment of articulation in speech, OHRQoL based on total OHIP-14, and satisfaction with overall oral health and speech (visual analogue scale). RESULTS: There was a reduction in mean number of articulation disorders from 1.00 at baseline to 0.55 at connection, although statistically insignificant (p = 0.059). Especially the /s/ sound is vulnerable. At 3 years follow-up, still 6/16 (37.5%) of the patients suffered from this speech problem. Overall satisfaction improved from 64.05/100 at baseline to 82.95/100 at connection (p = 0.008) and remained unchanged with 81.69/100 after 3 years follow-up. Patients' satisfaction with speech increased from 70.62/100 with CD to 82.63/100, 3 years follow-up (p = 0.009). Total OHIP-14 decreased from 21.45/56 with CD to 8.00/56 (p < 0.001) with IOD and 6.13/56 3 years after connection (p = 0.001). Significant improvement of all seven domains in OHRQoL was observed with IOD compared to CD. CONCLUSIONS: Patients treated with maxillary IODs show improved OHRQoL 3 years after connection of the IOD compared to the CD. Even though patients reported improvement of satisfaction and OHRQoL, articulation disorders were still present, suggesting that patients should be informed about possible speech issues.


Assuntos
Revestimento de Dentadura , Qualidade de Vida , Prótese Dentária Fixada por Implante , Retenção de Dentadura , Seguimentos , Humanos , Maxila , Satisfação do Paciente , Estudos Prospectivos , Fala , Resultado do Tratamento
15.
Clin Implant Dent Relat Res ; 23(3): 298-308, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34076941

RESUMO

PURPOSE: To evaluate the effect of early bone loss (EBL), on long-term bone stability and future peri-implantitis development. MATERIALS AND METHODS: Patients referred for implant placement between 2005 and 2009 were consecutively treated and followed for 10 years. After 10 years, patients were invited for a scientific diagnostic visit to evaluate implant survival and bone loss. Bone level changes were compared with baseline. Non-parametric testing was performed in cross-tabs (Pearson Chi-square and Fishers's exact test). Kaplan-Meier-estimated survival curves were plotted for different thresholds for EBL at different timepoints. Generalized linear mixed models with binomial distribution and logit link for peri-implantitis were fitted. An adjusted logistic mixed model was made to evaluate peri-implantitis, in relation with smoking status, history of periodontitis, and EBL > 0.5 mm. RESULTS: Four hundred and seven patients (mean age of 64.86 years [range 28-92, SD 10.11]), with 1482 implants, responded to the 10-year recall invitation. After an average follow-up time of 10.66 years (range 10-14, SD 0.87), implant survival was 94.74%. Mean crestal bone loss after 10 years was 0.81 mm (SD 1.58, range 0.00-17.00). One hundred and seventy five implants in 76 patients had peri-implantitis (11.8% on implant level, 18.7% on patient level). EBL of 0.5, 1, and 2 mm were significant predictors for peri-implantitis and implant loss after 10 years. Implants with EBL ≥0.5 mm during the first year of function showed a 5.43 times higher odds for future peri-implantitis development. Probability in developing peri-implantitis was 52.06% when smoking, Periodontal history and EBL of >0.5 mm was combined. CONCLUSION: The present study suggests that EBL is a predictor for long-term peri-implant pathology, with a significant higher risk for peri-implantitis when early bone loss exceeds the thresholds of 0.5 and 1 mm, especially when additional risk factors such as smoking or susceptibility for periodontal disease prior to implant treatment are present. Clinical trial registration number B670201524796.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Peri-Implantite , Periodontite , Adulto , Idoso , Idoso de 80 Anos ou mais , Perda do Osso Alveolar/etiologia , Implantes Dentários/efeitos adversos , Humanos , Pessoa de Meia-Idade , Peri-Implantite/etiologia , Estudos Prospectivos , Fatores de Risco
16.
BMC Oral Health ; 21(1): 115, 2021 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-33711975

RESUMO

BACKGROUND: The aims of this study were (1) to determine the accuracy, sensitivity, and specificity of panoramic and peri-apical radiographs in diagnosing furcation involvement, as well as (2) to evaluate the possible impact of clinical experience on these diagnostic parameters. METHODS: An existing radiographic dataset of periodontitis patients requiring implant surgery was retrospectively examined for furcation involvement. Criteria for inclusion were the presence of a CBCT, panoramic and peri-apical radiograph of the site of interest within a one-year time frame. All furcation sites were classified using the CBCT, which was considered as the gold standard, according to Hamp's index (1975). Ten experienced examiners and 10 trainees were asked to assess furcation involvement for the same defects using only the corresponding panoramic and peri-apical radiographs. Absolute agreement, Cohen's weighted kappa, sensitivity, specificity and ROC-curves were analyzed. RESULTS: The study sample included 60 furcation sites in 29 multi-rooted teeth from 17 patients. On average, 20/60 furcations were correctly classified according to the panoramic radiographs, corresponding to a weighted kappa score of 0.209, indicating slight agreement. Similarly, an average of 19/60 furcations were correctly classified according to the peri-apical radiographs, corresponding to a weighted kappa score of 0.211, also indicating slight agreement. No significant difference between panoramic and peri-apical radiography was found (P = 0.903). When recategorizing FI Grades into 'no to limited FI' (FI Grade 0 and I) and 'advanced FI' (FI Grade II and III), the panoramic and peri-apical radiography showed low sensitivity (0.558 and 0.441, respectively), yet high specificity (0.791 and 0.790, respectively) for identifying advanced FI. The ROC-curves for the panoramic and peri-apical radiographs were 0.79 and 0.69 respectively. No significant difference was found between experienced periodontists and trainees (P = 0.257 versus P = 0.880). CONCLUSION: Panoramic and peri-apical radiography are relevant tools in the diagnosis of FI and provide high specificity. Ideally, they are best used in combination with furcation probing, which shows high sensitivity. Furthermore, clinical experience does not seem to improve the accuracy of a radiological diagnosis of furcation sites. TRIAL REGISTRATION: Patient radiographic datasets were retrospectively analyzed.


Assuntos
Defeitos da Furca , Defeitos da Furca/diagnóstico por imagem , Humanos , Dente Molar , Radiografia , Radiografia Panorâmica , Estudos Retrospectivos
17.
Clin Implant Dent Relat Res ; 23(3): 400-407, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33595178

RESUMO

BACKGROUND: Bony concavities at the buccal aspect may cause a distortion between the implant axis and ideal prosthetic axis. Angulated implants can overcome this problem, yet long-term data are lacking. In addition, papilla-sparing incisions have been proposed to reduce tissue loss, yet aesthetic outcomes have not been published. PURPOSE: To evaluate the 5 to 7-year outcome of single angulated implants installed following papilla-sparing flap elevation. MATERIALS AND METHODS: Patients who had been consecutively treated with a single angulated implant (Co-axis®, Southern Implants, Irene, South Africa) in the anterior maxilla were re-examined after 5 to 7 years. Available data at 1 year (T1) were compared to those obtained at 5 to 7 years (T2). RESULTS: Twenty out of 22 treated patients (11 females, 9 males, mean age of 52) with 22 implants attended the 5 to 7-year reassessment. All implants survived and stable clinical conditions could be reached with mean marginal bone loss of 1.28 mm at T2. Papilla-sparing flap elevation resulted in Pink Esthetic Score of 9.83 at T1 and 8.23 at T2 (p = 0.072). Mucosal Scarring Index was 4.61 at T1 and 3.50 at T2 (p = 0.165). The overall appearance of scarring significantly improved over time (p = 0.032), yet 59% of the cases still demonstrated scarring at T2.c CONCLUSIONS: Within the limitations of the study, angulated implants (Co-axis®, Southern Implants) reached stable clinical conditions. Papilla-sparing incisions may not be recommended in aesthetically demanding patients due to high risk of scarring.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Estética Dentária , Feminino , Gengiva , Humanos , Masculino , Maxila/diagnóstico por imagem , Maxila/cirurgia , África do Sul , Resultado do Tratamento
18.
Clin Implant Dent Relat Res ; 23(3): 388-399, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33615684

RESUMO

BACKGROUND: Modifications of facial and oral structures affect aesthetic appearance, orofacial functions, and have impact on quality of life. PURPOSE: This study determined alterations of articulation, oromyofunctional behavior, and Oral Health Related Quality of Life (OHRQoL) in patients replacing complete removable dentures by implant retained overdentures in the mandible. MATERIALS AND METHODS: Twenty-one fully edentulous patients received mandibular overdenture retained on a bar connecting two titanium dental implants. Patients were evaluated after receiving a new set of fully removable dentures (stage 1), after surgery during provisionalization on healing abutments (stage 2), and after final connection to the bar (stage 3). Assessments were taken by speech therapists and included evaluation of: articulation (picture naming and reading); oromyofunctional behavior; OHRQoL (OHIP-14 questionnaire), and overall satisfaction and speech (VAS). To measure changes over time, Wilcoxon matched-pairs signed-rank-test and McNemar test was used. RESULTS: There was no significant impact of the treatment on speech nor on the results of oromyofunction. In stage 1, patients had different kinds of articulation errors (mean:1.21) which evolved to 0.71 and 0.67. In stage 3, especially problems with the /s/ sound are seen in 37% (7/19) of the participants. Results of OHRQoL and satisfaction reveal that the average of satisfaction with oral health evolved from 67% to 63% and finally 78%. OHIP-14 total score was 17.4/56 in stage 1, remained unchanged in stage 2 and evolved in stage 3 to 9.8/56 (P: .010). This indicates improvement. Satisfaction with speech evolved significantly from 68% pretreatment to 82% in stage 3 (P: .013). CONCLUSION: Despite existing articulation and oromyofunctional disorders after treatment, people are very satisfied with their OHRQoL and their speech. Impact of mandibular denture wearing on OHRQoL declines once connected. It's important to inform patients that speech and oromyofunctional disorders may occur during treatment where especially the /s/ sound is vulnerable.


Assuntos
Implantes Dentários , Arcada Edêntula , Prótese Dentária Fixada por Implante , Retenção de Dentadura , Revestimento de Dentadura , Humanos , Mandíbula/cirurgia , Satisfação do Paciente , Estudos Prospectivos , Qualidade de Vida
19.
J Clin Med ; 10(3)2021 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-33498516

RESUMO

PURPOSE: The aim of this in vitro study is to evaluate the accuracy of implant position using mucosal supported surgical guides, produced by a desktop 3D printer. METHODS: Ninety implants (Bone Level Roxolid, 4.1 mm × 10 mm, Straumann, Villerat, Switzerland) were placed in fifteen mandibular casts (Bonemodels, Castellón de la Plana, Spain). A mucosa-supported guide was designed and printed for each of the fifteen casts. After placement of the implants, the location was assessed by scanning the cast and scan bodies with an intra-oral scanner (Primescan®, Dentsply Sirona, York, PA, USA). Two comparisons were performed: one with the mucosa as a reference, and one where only the implants were aligned. Angular, coronal and apical deviations were measured. RESULTS: The mean implant angular deviation for tissue and implant alignment were 3.25° (SD 1.69°) and 2.39° (SD 1.42°) respectively, the coronal deviation 0.82 mm (SD 0.43 mm) and 0.45 mm (SD 0.31 mm) and the apical deviation 0.99 mm (SD 0.45 mm) and 0.71 mm (SD 0.43 mm). All three variables were significantly different between the tissue and implant alignment (p < 0.001). CONCLUSION: Based on the results of this study, we conclude that guided implant surgery using desktop 3D printed mucosa-supported guides has a clinically acceptable level of accuracy. The resilience of the mucosa has a negative effect on the guide stability and increases the deviation in implant position.

20.
Clin Oral Implants Res ; 32(1): 23-36, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33043547

RESUMO

OBJECTIVES: Longitudinal evaluation of Oral Health-Related Quality of Life (OHRQoL) during treatment of flaplessly placed, one-piece mini-dental-implants (MDIs) for maxillary overdentures is rarely investigated, nor is the impact of MDI failures. MATERIAL AND METHODS: This multicenter prospective cohort study evaluated the 3-year outcome of 5-6 MDIs in the edentulous maxilla in patients above 50 years with dentate mandible. Provisional dentures were provided before final prosthetic connection was established at 6 months. Postoperative discomfort was assessed using a visual analogue score (VAS). OHRQoL was investigated using the Oral Health Impact Profile (OHIP)-14 at baseline (preoperatively), postoperatively, post-prosthetic connection and after 3 years in function. RESULTS: 164 (78.4%) of the 204 placed MDIs were still in situ after 3 years, in 29/31 patients. Two patients lost 5/6 MDIs resulting in two prosthetic failures (6.45%). With regard to pain, a score of 4.1/10 (SD 2.8) was recorded on day 1, and 1.1/10 (SD 1.7) on day 7. A decrease in total OHIP-14 scores was observed postoperatively (15.6; SD 12.8) as compared to baseline (21.3; SD 13.1), with improvement of OHRQoL. Furthermore, this was statistically significant at connection of the final prosthesis (7.3; SD 6.7) (p = .006). The OHIP-14 improved less (p = .011) when experiencing one or more implant losses (9.5; SD: 9.85), in comparison with no implant loss (20.7; SD: 13.97). A failure of one MDI did not affect OHIP-14 score (p = .658); however, multiple failures did (p = .007). CONCLUSION: Maxillary MDI overdenture treatment yields significant OHRQoL improvement when at least 5 MDIs survive, preserving functional comfort.


Assuntos
Implantes Dentários , Arcada Edêntula , Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Humanos , Arcada Edêntula/cirurgia , Maxila/cirurgia , Satisfação do Paciente , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...