Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int Orthop ; 33(2): 339-46, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17987290

RESUMO

The Register for Orthopaedic Prosthetic Implantation (RIPO) has been prospectively collecting data on hip prostheses performed in all the orthopaedic units in the region Emilia-Romagna since January 2000. The register aims to determine the characteristics of patients, evaluate the effectiveness of prostheses, and allow internal audit. Adherence to the register is compulsory (93% capture). By 31 December 2006 the register contained data on 35,041 primary total hip arthroplasty (THA), 14,613 hemiarthoplasties, and 5,878 revisions. All prosthetic components are registered on an individual basis. Survival analysis is done following the Kaplan Meier method. Cumulative survival rate at 7 years is 96.8% (95% CI: 96.4-97.1%) for THA and 97.6% (97.0-98.3%) for hemiarthroplasties. Multivariate analysis verified that survival of the THA is affected by pathology, where the worst conditions are rheumatoid arthritis, femoral neck fracture, and sequelae of coxitis or Paget's disease. Results are comparable to other major registers of Northern Europe and Australia.


Assuntos
Artroplastia de Quadril/métodos , Artroplastia de Quadril/estatística & dados numéricos , Prótese de Quadril , Sistema de Registros , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Intervalos de Confiança , Feminino , Seguimentos , Humanos , Incidência , Itália , Masculino , Pessoa de Meia-Idade , Probabilidade , Desenho de Prótese , Falha de Prótese , Amplitude de Movimento Articular/fisiologia , Recuperação de Função Fisiológica , Reoperação/estatística & dados numéricos , Medição de Risco , Fatores Sexuais , Fatores de Tempo , Adulto Jovem
2.
J Biomater Appl ; 21(2): 131-45, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16443627

RESUMO

Hylamer polyethylene is a crystalline form of polyethylene of 70% crystallinity whereas conventional polyethylene (PE) has 50% crystallinity. Crystallinity is the percentage by weight of the crystalline phase present in the whole polymer, which comprises both amorphous and crystalline phases. Clinical experience has shown that Hylamer components used in joint prostheses, if sterilized by gamma rays in the presence of oxygen, are easily affected by wear, which leads to osteolysis. The authors have analyzed the crystallinity of polyethylene liners removed from seven patients who had received Hylamer polyethylene implants sterilized by gamma rays in air and had suffered prosthetic loosening, using Raman spectroscopy coupled with partial least squares (PLS) analysis. The results have been compared to those of two controls who had received Hylamer polyethylene implants sterilized by gamma irradiation in a nitrogen atmosphere. The crystal structure of wear particles released into the tissues from the Hylamer liners sterilized by gamma rays in air is also studied. The materials undergoing two different types of sterilization methods show different crystallinity values (71.50 vs. 69.43), but the crystallinity do not change according to wear (worn and unworn liner region). Both monoclinic and orthorhombic phases are present in the liner, while in wear debris prevalently monoclinic crystals are found in both types of sterilized liners. Different crystallinity rates can explain different wear rates observed in vivo.


Assuntos
Prótese de Quadril , Polietileno/química , Idoso , Artroplastia de Quadril/instrumentação , Cristalização , Feminino , Raios gama , Humanos , Análise dos Mínimos Quadrados , Masculino , Pessoa de Meia-Idade , Nitrogênio , Oxigênio , Polietileno/efeitos da radiação , Desenho de Prótese , Análise Espectral Raman , Esterilização/métodos
3.
Int Orthop ; 29(3): 135-9, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15809874

RESUMO

Between October 1992 and December 1996, 23 patients with pelvic bone stock deficiency involving major columns underwent revision surgery with a cementless press-fit cup and a structural bone graft. Twenty cases were followed up for a minimum of 6 (average 7.6, range 6-11) years. Three cups were revised: one for aseptic loosening, one for septic loosening, and one for recurrent dislocation. At latest follow-up, the average Merle d'Aubigne hip score improved from 10.9 to 16.2; four hips were rated excellent, seven very good, three good, two fair, and one poor. All cups were stable; the grafts were integrated and anatomy was restored. The Kaplan-Meier cumulative probability of not having revision for loosening at 11 years, predicted a survival rate of 84.4%. We are confident that these results are satisfactory for a very demanding procedure.


Assuntos
Artroplastia de Quadril/métodos , Transplante Ósseo/métodos , Articulação do Quadril , Prótese de Quadril , Artropatias/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação , Transplante Homólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...