1.
Eur Cell Mater ; 33: 13-27, 2017 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-28076651

RESUMO

Roughened surfaces are increasingly being used for dental implant applications as the enlarged contact area improves bone cell anchorage, thereby facilitating osseointegration. However, the additional surface area also entails a higher risk for the development of biofilm associated infections, an etiologic factor for many dental ailments, including peri-implantitis. To overcome this problem, we designed a dental implant composed of a porous titanium-silica (Ti/SiO2) composite material and containing an internal reservoir that can be loaded with antimicrobial compounds. The composite material consists of a sol-gel derived mesoporous SiO2 diffusion barrier integrated in a macroporous Ti load-bearing structure obtained by powder metallurgical processing. The antimicrobial compounds can diffuse through the porous implant walls, thereby reducing microbial biofilm formation on the implant surface. A continuous release of µM concentrations of chlorhexidine through the Ti/SiO2 composite material was measured, without initial burst effect, over at least 10 days and using a 5 mM chlorhexidine solution in the implant reservoir. Metabolic staining, CFU counting and visualisation by scanning electron microscopy confirmed that Streptococcus mutans biofilm formation on the implant surface was almost completely prevented due to chlorhexidine release (preventive setup). Moreover, we demonstrated efficacy of released chlorhexidine against mature Streptococcus mutans biofilms (curative setup). In conclusion, we provide a proof of concept of the sustained release of chlorhexidine, one of the most widely used oral antiseptics, through the Ti/SiO2 material thereby preventing and eradicating biofilm formation on the surface of the dental implant. In principle, our flexible design allows for the use of any bioactive compound, as discussed.


Assuntos
Biofilmes/crescimento & desenvolvimento , Clorexidina/administração & dosagem , Clorexidina/farmacologia , Implantes Dentários , Dióxido de Silício/química , Streptococcus mutans/fisiologia , Titânio/farmacologia , Biofilmes/efeitos dos fármacos , Linhagem Celular Tumoral , Preparações de Ação Retardada , Humanos , Testes de Sensibilidade Microbiana , Viabilidade Microbiana/efeitos dos fármacos , Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Porosidade , Desenho de Prótese , Streptococcus mutans/efeitos dos fármacos , Streptococcus mutans/metabolismo , Streptococcus mutans/ultraestrutura
2.
Environ Res ; 148: 256-263, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27085497

RESUMO

BACKGROUND: Following a train derailment, several tons of acrylonitrile (ACN) exploded, inflamed and part of the ACN ended up in the sewage system of the village of Wetteren. More than 2000 residents living in the close vicinity of the accident and along the sewage system were evacuated. A human biomonitoring study of the adduct N-2-cyanoethylvaline (CEV) was carried out days 14-21 after the accident. OBJECTIVES: (1) To describe the short-term health effects that were reported by the evacuated residents following the train accident, and (2) to explore the association between the CEV concentrations, extrapolated at the time of the accident, and the self-reported short-term health effects. METHODS: Short-term health effects were reported in a questionnaire (n=191). An omnibus test of independence was used to investigate the association between the CEV concentrations and the symptoms. Dose-response relationships were quantified by Generalized Additive Models (GAMs). RESULTS: The most frequently reported symptoms were local symptoms of irritation. In non-smokers, dose-dependency was observed between the CEV levels and the self-reporting of irritation (p=0.007) and nausea (p=0.007). Almost all non-smokers with CEV concentrations above 100pmol/g globin reported irritation symptoms. Both absence and presence of symptoms was reported by non-smokers with CEV concentrations below the reference value and up to 10 times the reference value. Residents who visited the emergency services reported more symptoms. This trend was seen for the whole range of CEV concentrations, and thus independently of the dose. DISCUSSION AND CONCLUSION: The present study is one of the first to relate exposure levels to a chemical released during a chemical incident to short-term (self-reported) health effects. A dose-response relation was observed between the CEV concentrations and the reporting of short-term health effects in the non-smokers. Overall, the value of self-reported symptoms to assess exposure showed to be limited. The results of this study confirm that a critical view should be taken when considering self-reported health complaints and that ideally biomarkers are monitored to allow an objective assessment of exposure.


Assuntos
Acrilonitrila/toxicidade , Vazamento de Resíduos Químicos , Irritantes/toxicidade , Ferrovias , Adulto , Bélgica , Cotinina/urina , Relação Dose-Resposta a Droga , Monitoramento Ambiental , Feminino , Cefaleia/induzido quimicamente , Humanos , Masculino , Pessoa de Meia-Idade , Náusea/induzido quimicamente , Autorrelato , Fumar/sangue , Fumar/urina , Inquéritos e Questionários , Tremor/induzido quimicamente , Valina/análogos & derivados , Valina/sangue
3.
Artigo em Inglês | MEDLINE | ID: mdl-25756209

RESUMO

Despite decades of creatinine measurement in biological fluids using a large variety of analytical methods, an accurate determination of this compound remains challenging. Especially with the novel trend to assess biomarkers on large sample sets preserved in biobanks, a simple and fast method that could cope with both a high sample throughput and a low volume of sample is still of interest. In answer to these challenges, a fast and accurate ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed to measure creatinine in small volumes of human urine. In this method, urine samples are simply diluted with a basic mobile phase and injected directly under positive electrospray ionization (ESI) conditions, without further purification steps. The combination of an important diluting factor (10(4) times) due to the use of a very sensitive triple quadrupole mass spectrometer (XEVO TQ) and the addition of creatinine-d3 as internal standard completely eliminates matrix effects coming from the urine. The method was validated in-house in 2012 according to the EMA guideline on bioanalytical method validation using Certified Reference samples from the German External Quality Assessment Scheme (G-Equas) proficiency test. All obtained results for accuracy and recovery are within the authorized tolerance ranges defined by G-Equas. The method is linear between 0 and 5 g/L, with LOD and LOQ of 5 × 10(-3) g/L and 10(-2) g/L, respectively. The repeatability (CV(r) = 1.03-2.07%) and intra-laboratory reproducibility (CV(RW) = 1.97-2.40%) satisfy the EMA 2012 guideline. The validated method was firstly applied to perform the German G-Equas proficiency test rounds 51 and 53, in 2013 and 2014, respectively. The obtained results were again all within the accepted tolerance ranges and very close to the reference values defined by the organizers of the proficiency test scheme, demonstrating an excellent accuracy of the developed method. The method was finally applied to measure the creatinine concentration in 210 urine samples, coming from 190 patients with a chronic kidney disease (CKD) and 20 healthy subjects. The obtained creatinine concentrations (ranging from 0.12 g/L up to 3.84 g/L) were compared, by means of a Passing Bablok regression, with the creatinine contents obtained for the same samples measured using a traditional compensated Jaffé method. The UHPLC-MS/MS method described in this paper can be used to normalize the concentration of biomarkers in urine for the extent of dilution.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Creatinina/urina , Espectrometria de Massas em Tandem/métodos , Biomarcadores/urina , Humanos , Limite de Detecção , Modelos Lineares , Insuficiência Renal Crônica/urina , Reprodutibilidade dos Testes
4.
Toxicol Lett ; 231(3): 344-51, 2014 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-25223249

RESUMO

BACKGROUND: On Saturday May 4, 2013, a train transporting chemicals derailed in the village of Wetteren (Belgium) and caused a leak of acrylonitrile (ACN). OBJECTIVES: To assess the human exposure to acrylonitrile in the local population with the highest suspected exposure. METHODS: Between May 18-25, 242 residents participated in the study. N-2-cyanoethylvaline (CEV), a biomarker that is highly specific for ACN exposure, was measured in the blood. To account for potential influence by smoking, cotinine was determined in the urine. Participants also filled in a short questionnaire. RESULTS: In the evacuated zone, 37.3% of the non-smokers and 40.0% of the smokers had CEV concentrations above the reference values of 10 and 200 pmol/g globin, respectively, at the time of the train accident. Spatial mapping of the CEV concentrations depending on the residential address showed a distribution pattern following the sewage system. DISCUSSION AND CONCLUSION: The train derailment resulted in a highly atypical sequence-of-events. In addition to exposure in the direct vicinity of the site of the train derailment, exposure also occurred via the sewage system, into which acrylonitrile had entered shortly after the accident.


Assuntos
Acrilonitrila/sangue , Vazamento de Resíduos Químicos , Exposição Ambiental/análise , Monitoramento Ambiental/métodos , Valina/análogos & derivados , Acrilonitrila/intoxicação , Adulto , Bélgica , Exposição Ambiental/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ferrovias , Esgotos/análise , Inquéritos e Questionários , Valina/sangue
5.
Toxicol Lett ; 231(3): 352-9, 2014 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-25128591

RESUMO

BACKGROUND: On May 4, 2013, a train transporting chemicals derailed in Wetteren, Belgium. Several tanks loaded with acrylonitrile (ACN) exploded, resulting in a fire and a leakage of ACN. OBJECTIVES: To determine exposure to ACN and to assess discriminating factors for ACN exposure in the emergency responders involved in the on-site management of the train accident. METHODS: The study population consisted of 841 emergency responders. Between May 21 and June 28, they gave blood for the determination of N-2-cyanoethylvaline (CEV) hemoglobin adducts and urine for the measurement of cotinine. They also filled in a short questionnaire. RESULTS: 163 (26%) non-smokers and 55 (27%) smokers showed CEV concentrations above the reference values of 10 and 200 pmol/g globin, respectively. The 95th percentile in the non-smokers was 73 pmol/g globin and the maximum was 452 pmol/g globin. ACN exposure among the non-smokers was predicted by (1) the distance to the accident, (2) the duration of exposure, and (3) the occupational function. DISCUSSION AND CONCLUSION: Emergency responders involved in the on-site management of the train accident were clearly exposed to ACN from the accident. However, the extent of exposure remained relatively moderate with CEV concentrations staying within the ranges described in literature as background for a smoking population. Moreover, the exposure was less pronounced in the emergency responders as compared to that in the local population.


Assuntos
Acrilonitrila/sangue , Acrilonitrila/urina , Vazamento de Resíduos Químicos , Socorristas , Monitoramento Ambiental/métodos , Exposição Ocupacional/análise , Acrilonitrila/intoxicação , Adulto , Bélgica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/efeitos adversos , Ferrovias , Análise de Regressão , Inquéritos e Questionários , Valina/análogos & derivados , Valina/sangue , Valina/urina
6.
J Chromatogr B Biomed Sci Appl ; 757(1): 21-9, 2001 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-11419745

RESUMO

Seven chromatographic columns were evaluated for the recovery of 48V-radiolabelled vanadate. Further, the behaviour of vanadate (H2VO4-) was studied on a size-exclusion column Superose 12 as a function of (a) buffer salt molarity, (b) different buffer salts, (c) different buffers and (d) organic solvents added to the buffer. As opposed to the unsatisfactory recovery of V-compounds on other columns, we recovered the vanadium quantitatively. We observed that in most cases vanadate eluted after the total volume of the Superose 12 column. This indicates a non-ideal behaviour of vanadate. However, through this non-ideal behaviour it was possible to separate low-molecular-mass bound (Mr<5000) and unbound vanadium which would not be possible under normal behaviour. A possible explanation for this non-ideal behaviour of vanadium is put forward. The method has been successfully applied for the fractionation of different vanadium species in rat spleen homogenate.


Assuntos
Cromatografia em Gel/métodos , Baço/química , Vanadatos/química , Animais , Soluções Tampão , Peso Molecular , Ratos , Sais , Solventes
7.
J Environ Monit ; 3(1): 86-90, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11253025

RESUMO

Five Wistar rats were given an intraperitoneal injection of [114mIn]InCl3 during four consecutive days. One hour after the last injection the rats were sacrificed. The in vivo distribution of 114mIn was studied in the blood and in different organs. Differential centrifugation was used to study the distribution in liver, kidney and spleen homogenate. Rat serum, packed cell lysate, urine and the cytosol of liver, kidney and spleen homogenate were examined by size exclusion fast protein liquid chromatography. The results showed that serum accounts for 90% of the indium activity in whole blood. Indium is preferentially accumulated within the liver, spleen and kidney, the highest amount of 114mIn being localised in the cytosolic fraction followed by the mitochondria. Size exclusion experiments showed that, in rat serum, indium is exclusively bound to transferrin. These results differed from earlier in vitro incubation experiments of human serum with 114mIn. It was not possible, from the experiments described herein, to conclude unequivocally whether indium is bound to haemoglobin of packed cell lysate or to another high molecular mass compound. Indium is associated with the high molecular mass fraction in liver, kidney and spleen cytosol; only in kidney are small amounts of 114mIn found in the low molecular mass fraction. The in vivo inhibitory effect of indium on the delta-aminolaevulinic acid dehydratase (ALAD) enzymatic activity in red blood cells and kidney tissue, well documented by other researchers, could not be attributed to direct binding of indium with this enzyme.


Assuntos
Radioisótopos de Índio/farmacocinética , Índio/farmacocinética , Animais , Sítios de Ligação , Hemoglobinas , Índio/administração & dosagem , Radioisótopos de Índio/administração & dosagem , Infusões Parenterais , Rim/química , Masculino , Ratos , Ratos Wistar , Distribuição Tecidual
8.
Fresenius J Anal Chem ; 368(2-3): 293-6, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11220595

RESUMO

The chemical speciation of indium in serum was studied. Ultrafiltration was used to investigate the influence of several buffer systems on the binding characteristics of indium in serum and to study the association of indium with transferrin and albumin. This was performed by means of batch incubation experiments with a 114mIn tracer. Different buffer systems were investigated. A series of bicarbonate, Tris:HCl and HEPES buffers were found to fit for this purpose. Phosphate buffer was not suitable, as it is capable of disrupting the binding between indium and transferrin. Batch ultrafiltration experiments with 114mIn incubated solutions of transferrin and albumin showed that both proteins are capable of binding indium to a high degree. Three chromatographic techniques (SEC, AEC, AC) were used to study the different chemically active species of indium in serum. It is concluded that next to transferrin, albumin is also responsible for the binding and transport of indium in serum.


Assuntos
Cromatografia de Afinidade/métodos , Cromatografia em Gel/métodos , Radioisótopos de Índio/metabolismo , Albumina Sérica/metabolismo , Transferrina/metabolismo , Ultrafiltração , Humanos , Ligação Proteica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA