Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
J Nucl Med ; 65(2): 178-184, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38302159

RESUMO

Human epidermal growth factor receptor 2 (HER2) status is used for decision-making in breast carcinoma treatment. The status is obtained through immunohistochemistry or in situ hybridization. These two methods have the disadvantage of necessitating tissue sampling, which is prone to error due to tumor heterogeneity or interobserver variability. Whole-body imaging might be a solution to map HER2 expression throughout the body. Methods: Twenty patients with locally advanced or metastatic breast carcinoma (5 HER2-positive and 15 HER2-negative patients) were included in this phase II trial to assess the repeatability of uptake quantification and the extended safety of the [68Ga]Ga-NOTA-anti-HER2 single-domain antibody (sdAb). The tracer was injected, followed by a PET/CT scan at 90 min. Within 8 d, the procedure was repeated. Blood samples were taken for antidrug antibody (ADA) assessment and liquid biopsies. On available tissues, immunohistochemistry, in situ hybridization, and mass spectrometry were performed to determine the correlation of HER2 status with uptake values measured on PET. If relevant preexisting [18F]FDG PET/CT images were available (performed as standard of care), a comparison was made. Results: With a repeatability coefficient of 21.8%, this imaging technique was repeatable. No clear correlation between PET/CT uptake values and pathology could be established, as even patients with low levels of HER2 expression showed moderate to high uptake. Comparison with [18F]FDG PET/CT in 16 patients demonstrated that in 7 patients, [68Ga]Ga-NOTA-anti-HER2 shows interlesional heterogeneity within the same patient, and [18F]FDG uptake did not show the same heterogeneous uptake in all patients. In some patients, the extent of disease was clearer with the [68Ga]Ga-NOTA-anti-HER2-sdAb. Sixteen adverse events were reported but all without a clear relationship to the tracer. Three patients with preexisting ADAs did not show adverse reactions. No new ADAs developed. Conclusion: [68Ga]Ga-NOTA-anti-HER2-sdAb PET/CT imaging shows similar repeatability to [18F]FDG. It is safe for clinical use. There is tracer uptake in cancer lesions, even in patients previously determined to be HER2-low or -negative. The tracer shows potential in the assessment of interlesional heterogeneity of HER2 expression. In a subset of patients, [68Ga]Ga-NOTA-anti-HER2-sdAb uptake was seen in lesions with no or low [18F]FDG uptake. These findings support further clinical development of [68Ga]Ga-NOTA-anti-HER2-sdAb as a PET/CT tracer in breast cancer patients.


Assuntos
Neoplasias da Mama , Anticorpos de Domínio Único , Humanos , Feminino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Anticorpos de Domínio Único/metabolismo , Radioisótopos de Gálio , Fluordesoxiglucose F18 , Neoplasias da Mama/metabolismo , Tomografia por Emissão de Pósitrons
2.
Artigo em Inglês | MEDLINE | ID: mdl-38064892

RESUMO

Summary: Primary hyperparathyroidism most commonly presents with hypercalcaemia. Rarely, parathyroid apoplexy or haemorrhage mimicking a thyroid bleeding cyst is the first presentation of a parathyroid adenoma. A woman presented with a sudden-onset painful 'goitre'. Ultrasound showed a cystic nodule located posterior to rather than in the right thyroid lobe, suggesting parathyroid adenoma bleeding. Biochemistry showed mild primary hyperparathyroidism. 99mTc-pertechnetate/sestamibi showed no uptake in the nodule, which was interpreted as a cold thyroid nodule. 18F-fluorocholine PET/CT showed uptake in the nodule, suggestive of a parathyroid adenoma. Persistent mild primary hyperparathyroidism complicated by nephrolithiasis and osteopenia favoured parathyroidectomy over a wait-and-see approach. The patient was referred for parathyroidectomy along with right thyroid lobectomy. Pathology showed an adenoma, with an eccentrically located cystic structure filled with red blood cells surrounded by a thickened fibrous capsule. In conclusion, cervical pain/haemorrhage with hypercalcaemia points to the diagnosis of parathyroid apoplexy, mimicking a thyroid bleeding cyst. Workup with ultrasound and, if available, 18F-choline PET/CT allows for timely surgery, minimizing the risk of recurrent and severe bleeding. Learning points: A bleeding cyst may be located posterior to rather than in the thyroid, suggesting a parathyroid haemorrhage. Neck pain and/or haemorrhage along with primary hyperparathyroidism point to parathyroid apoplexy. A two-step presentation has been described, with a first phase of local symptoms to be followed by visible and possibly life-threatening compressing bleeding. Therefore, an expedited workup is needed, allowing for timely surgery.

3.
Sci Rep ; 13(1): 7568, 2023 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-37160895

RESUMO

We retrospectively evaluated how accurately preoperative imaging localizes parathyroid adenoma in superior versus inferior parathyroids. Over 6 years, 104 patients with primary hyperparathyroidism underwent parathyroid surgery in a single centre. Of these, 103 underwent ultrasound, 97 [99mTc]pertechnetate/MIBI SPECT/CT and 30 [18F]fluorocholine (FCH) PET/CT. One patient with a unilateral double adenoma was excluded from the analysis. Surgical findings with histopathologic confirmation of adenoma were used as the standard. Ultrasound misjudged 5 of 48 detected lower adenomas as upper, but 14 of 29 upper adenomas as lower (error rate 10 vs 48%, p = 0.0002). The corresponding error rates for [99mTc]pertechnetate/MIBI SPECT/CT were 3 versus 55% (p = 0.000014), and for [18F]FCH PET/CT 17 versus 36% (p = 0.26). Our results suggest that about half of the superior parathyroid adenomas which are detected, are erroneously assigned to the inferior position by both ultrasound and SPECT/CT imaging whereas the opposite mistake is significantly less frequent with ultrasound and SPECT/CT.


Assuntos
Adenoma , Hiperparatireoidismo , Neoplasias das Paratireoides , Humanos , Neoplasias das Paratireoides/complicações , Neoplasias das Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Pertecnetato Tc 99m de Sódio , Hiperparatireoidismo/diagnóstico por imagem , Hiperparatireoidismo/cirurgia , Adenoma/diagnóstico por imagem , Adenoma/cirurgia
4.
Hell J Nucl Med ; 26(1): 70-72, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37031424

RESUMO

Amyloidoisis in patients with Waldenström macroglobulinemia (WM) mostly involves the heart, peripheral nerves and kidneys. Retroperitoneal amyloidosis is a rare finding. We describe a 62-year-old man with an incidental finding of a monoclonal gammopathy and elevated inflammatory parameters. Bilateral moderately active retroperitoneal infiltration with punctiform calcifications was found on fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) imaging. Taken together, these findings are suggestive of Waldenström associated amyloidosis. Computed tomography-guided retroperitoneal biopsy confirmed the diagnosis.


Assuntos
Amiloidose , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Masculino , Humanos , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X , Amiloidose/complicações , Amiloidose/diagnóstico por imagem , Tomografia por Emissão de Pósitrons
6.
Sci Rep ; 12(1): 17427, 2022 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-36261462

RESUMO

The objective of this study was to retrospectively evaluate preoperative imaging modalities for localization of parathyroid adenomas with a view to enable minimally invasive parathyroidectomy and in particular, to consider the contribution of 18F-fluorocholine-PET/CT. 104 patients with primary hyperparathyroidism, who underwent parathyroid surgery in a single centre during a 6-year period were included. Of these, 103 underwent ultrasound, 97 99mTc-Pertechnetate/SestaMIBI-SPECT, 20 MRI and 30 18F-fluorocholine-PET/CT. Based on surgical findings, sensitivities and specificities for correct lateralisation in orthotopic locations were: for ultrasound 0.75 (0.65-0.83) and 0.89 (0.81-0.94), for 99mTc-MIBI-SPECT 0.57 (0.46-0.67) and 0.97 (0.91-0.99), for MRI 0.60 (0.36-0.81) and 0.83 (0.59-0.96) and for 18F-fluorocholine-PET/CT 0.90 (0.73-0.98) and 0.90 (0.73-0.98). Correctly lateralized adenomas were significantly larger than those not found with ultrasound (p = 0.03) and SPECT (p = 0.002). Pre-operative PTH-levels were higher in single adenomas detected by scintigraphy than in those not (p = 0.02). 64 patients could be treated with a minimally invasive procedure. Cure after parathyroidectomy was obtained in 94% of patients. 18F-Fluorocholine-PET/CT could be shown to be a highly accurate modality to localize parathyroid adenomas preoperatively, obviating the need for total exploration in the majority of patients in whom ultrasound and scintigraphic results are discordant or both negative.


Assuntos
Adenoma , Hiperparatireoidismo Primário , Neoplasias das Paratireoides , Humanos , Paratireoidectomia/métodos , Neoplasias das Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/cirurgia , Hiperparatireoidismo Primário/diagnóstico por imagem , Hiperparatireoidismo Primário/cirurgia , Estudos Retrospectivos , Glândulas Paratireoides/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Pertecnetato Tc 99m de Sódio , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Adenoma/diagnóstico por imagem , Adenoma/cirurgia , Compostos Radiofarmacêuticos
7.
EJNMMI Res ; 12(1): 34, 2022 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-35695940

RESUMO

BACKGROUND: FDG-PET/CT has a high negative predictive value to detect residual nodal disease in patients with locally advanced squamous cell head and neck cancer after completing concurrent chemoradiotherapy (CCRT). However, the positive predictive value remains suboptimal due to inflammation after radiotherapy, generating unnecessary further investigations and possibly even surgery. We report the results of a preplanned secondary end point of the ECLYPS study regarding the potential advantages of dual time point FDG-PET/CT imaging (DTPI) in this setting. Standardized dedicated head and neck FDG-PET/CT images were obtained 12 weeks after CCRT at 60 and 120 min after tracer administration. We performed a semiquantitative assessment of lymph nodes, and the retention index (RI) was explored to optimize diagnostic performance. The reference standard was histology, negative FDG-PET/CT at 1 year, or > 2 years of clinical follow-up. The time-dependent area under the receiver operator characteristics (AUROC) curves was calculated. RESULTS: In total, 102 subjects were eligible for analysis. SUV values increased in malignant nodes (median SUV1 = 2.6 vs. SUV2 = 2.7; P = 0.04) but not in benign nodes (median SUV1 = 1.8 vs. SUV2 = 1.7; P = 0.28). In benign nodes, RI was negative although highly variable (median RI = - 2.6; IQR 21.2), while in malignant nodes RI was positive (median RI = 12.3; IQR 37.2) and significantly higher (P = 0.018) compared to benign nodes. A combined threshold (SUV1 ≥ 2.2 + RI ≥ 3%) significantly reduced the amount of false-positive cases by 53% (P = 0.02) resulting in an increased specificity (90.8% vs. 80.5%) and PPV (52.9% vs. 37.0%), while sensitivity (60.0% vs. 66.7%) and NPV remained comparably high (92.9% vs. 93.3%). However, AUROC, as overall measure of benefit in diagnostic accuracy, did not significantly improve (P = 0.62). In HPV-related disease (n = 32), there was no significant difference between SUV1, SUV2, and RI in malignant and benign nodes, yet this subgroup was small. CONCLUSIONS: DTPI did not improve the overall diagnostic accuracy of FDG-PET/CT to detect residual disease 12 weeks after chemoradiation. Due to differences in tracer kinetics between malignant and benign nodes, DTPI improved the specificity, but at the expense of a loss in sensitivity, albeit minimal. Since false negatives at the 12 weeks PET/CT are mainly due to minimal residual disease, DTPI is not able to significantly improve sensitivity, but repeat scanning at a later time (e.g. after 12 months) could possibly solve this problem. Further study is required in HPV-associated disease.

8.
Acta Cardiol ; 77(9): 791-804, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34565298

RESUMO

BACKGROUND: Cardiac amyloidosis (CA) is often overlooked or misdiagnosed. Effects of growing disease awareness, diagnostic ameliorations and novel treatment options on CA diagnosis and management are scarcely reported. OBJECTIVE: To report trends in diagnosis, referral routes, clinical presentation, early onset diagnostic red flags and outcome in de novo CA subjects. METHODS: An unselected cohort of 139 de novo CA patients over an 8-year period in a tertiary referral hospital was recruited. RESULTS: Transthyretin (ATTR, 82%, n = 114) was the most common CA form; Light-chain (AL, 15%, n = 21) and secondary (AA, 3%, n = 4) are less prevalent. Increased awareness over time led to a marked ATTR diagnostic surge, steep non-invasive diagnostic approach increment and increased nuclear medicine and external cardiologist referrals (all p < 0.001). A total of 41% (n = 57/139) of patients were referred by non-cardiology specialist disciplines. Specific referral to rule out CA (24-36%) and diagnostic time lag from symptom onset (9 ± 12 to 8 ± 14 months), however, did not improve (all p > 0.050). Multiple early red flag events preceded CA diagnose several years in ATTR: Left ventricular hypertrophy (LVH, 60%, 4.9 ± 4.3 y), heart failure (54%, 2.5 ± 3.5 y), atrial fibrillation (47%, 5.9 ± 6.7 y), bilateral carpal tunnel syndrome (43%, 9.5 ± 5.7 y) and spinal stenosis (40%, 7.4 ± 6.5 y). LVH ≥ 12 mm was absent in 11% ATTR (n = 13/114) and 5% AL (n = 1/21) patients. Hypertension was common in both ATTR (n = 70/114, 62%) and AL (n = 10/21, 48%). 56% (n = 78/139) of CA presented with heart failure. Cumulative 1 and 5-year mortality of 10%/66%, 40%/52% and 75%/75% for ATTR, AL, and AA, respectively, remains high. CONCLUSIONS: Although CA diagnostic uptake and referral improve, specialist-specific disease and diagnostic red flag ignorance result in non-timely diagnosis and unfavourable outcome.


Assuntos
Neuropatias Amiloides Familiares , Fibrilação Atrial , Cardiomiopatias , Insuficiência Cardíaca , Humanos , Neuropatias Amiloides Familiares/diagnóstico , Neuropatias Amiloides Familiares/epidemiologia , Neuropatias Amiloides Familiares/complicações , Fibrilação Atrial/complicações , Insuficiência Cardíaca/complicações , Encaminhamento e Consulta , Cardiomiopatias/diagnóstico , Cardiomiopatias/complicações
9.
EJNMMI Phys ; 8(1): 67, 2021 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-34626242

RESUMO

BACKGROUND: Metal artefact reduction (MAR) techniques still are in limited use in positron emission tomography/computed tomography (PET/CT). This study aimed to investigate the effect of Smart MAR on quantitative PET analysis in the vicinity of hip prostheses. MATERIALS AND METHODS: Activities were measured on PET/CT images in 6 sources with tenfold activity concentration contrast to background, attached to the head, neck and the major trochanter of a human cadaveric femur, and in the same sources in similar locations after a hip prosthesis (titanium cup, ceramic head, chrome-cobalt stem) had been inserted into the femur. Measurements were compared between PET attenuation corrected using either conventional or MAR CT. In 38 patients harbouring 49 hip prostheses, standardized uptake values (SUV) in 6 periprosthetic regions and the bladder were compared between PET attenuation corrected with either conventional or MAR CT. RESULTS: Using conventional CT, measured activity decreased with 2 to 13% when the prosthesis was inserted. Use of MAR CT increased measured activity by up to 11% compared with conventional CT and reduced the relative difference with the reference values to under 5% in all sources. In all regions, to the exception of the prosthesis shaft, SUVmean increased significantly (p < 0.001) by use of MAR CT. Median (interquartile range) percentual increases of SUVmean were 1.4 (0.0-4.2), 4.0 (1.8-7.8), 7.8 (4.1-12.4), 1.5 (0.0-3.2), 1.4 (0.8-2.8) in acetabulum, lateral neck, medial neck, lateral diaphysis and medial diaphysis, respectively. Except for the shaft, the coefficient of variation did not increase significantly. Except for the erratic changes in the prosthesis shaft, decreases in SUVmean were rare and small. Bladder SUVmean increased by 0.9% in patients with unilateral prosthesis and by 4.1% in patients with bilateral prosthesis. CONCLUSIONS: In a realistic hip prosthesis phantom, Smart MAR restores quantitative accuracy by recovering counts in underestimated sources. In patient studies, Smart MAR increases SUV in all areas surrounding the prosthesis, most markedly in the femoral neck region. This proves that underestimation of activity in the PET image is the most prevalent effect due to metal artefacts in the CT image in patients with hip prostheses. Smart MAR increases SUV in the urinary bladder, indicating effects at a distance from the prosthesis.

10.
Eur J Nucl Med Mol Imaging ; 47(5): 1075-1082, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32040611

RESUMO

BACKGROUND: The Hopkins criteria were introduced for nodal response evaluation after therapy in head and neck cancer, but its superiority over quantification is not yet confirmed. METHODS: SUVbody weight thresholds and lesion-to-background ratios were explored in a prospective multicenter study of standardized FDG-PET/CT 12 weeks after CRT in newly diagnosed locally advanced head and neck squamous cell carcinoma (LAHNSCC) patients (ECLYPS). Reference standard was histology, negative FDG-PET/CT at 12 months after treatment or ≥ 2 years of negative follow-up. Area under the receiver operator characteristics curves (AUROC) were estimated and obtained thresholds were validated in an independent cohort of HNSCC patients (n = 127). RESULTS: In ECLYPS, 124 patients were available for quantification. With a median follow-up of 20.4 months, 23 (18.5%) nodal neck recurrences were observed. A SUV70 threshold of 2.2 (AUROC = 0.89; sensitivity = 79.7%; specificity = 80.8%) was identified as optimal metric to identify nodal recurrence within 1 year after therapy. For lesion-to-background ratios, an SUV50/SUVliver threshold of 0.96 (AUROC = 0.89; sensitivity = 79.7%; specificity = 82.8%) had the best performance. Compared with Hopkins criteria (AUROC = 0.81), SUV70 and SUV50/SUVliver provided a borderline significant (p = 0.040 and p = 0.094, respectively) improvement. Validation of thresholds yielded similar AUROC values (SUV70 = 0.93, SUV50/SUVliver = 0.95), and were comparable to the Hopkins score (AUROC = 0.91; not statistically significant). CONCLUSION: FDG quantification detects nodal relapse in LAHNSCC patients. When using EARL standardized PET acquisitions and reconstruction, absolute SUV metrics (SUV70 threshold 2.2) prove robust, yet ratios (SUV50/SUVliver, threshold 0.96) may be more useful in routine clinical care. In this setting, the diagnostic value of quantification is comparable to the Hopkins criteria. TRIAL REGISTRATION: US National Library for Medicine, NCT01179360. Registered 11 August 2010, https://clinicaltrials.gov/ct2/show/NCT01179360.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/terapia , Quimiorradioterapia , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/terapia , Humanos , Recidiva Local de Neoplasia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Carcinoma de Células Escamosas de Cabeça e Pescoço/terapia
11.
Clin Nucl Med ; 45(2): 131-132, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31876810

RESUMO

The utility of PET in septicemia for showing its source and possible metastatic infection has been demonstrated. We describe the diagnosis on PET/CT of a spontaneous corpus cavernosum abscess in a 64-year-old man presenting with Streptococcus constellatus septicemia, in whom the clinical diagnosis had been elusive for 10 days.


Assuntos
Abscesso/diagnóstico por imagem , Doenças do Pênis/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Infecções Estreptocócicas/diagnóstico por imagem , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos
13.
EJNMMI Phys ; 6(1): 8, 2019 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-31076884

RESUMO

BACKGROUND: This paper describes the National Electrical Manufacturers Association (NEMA) system performance of the Discovery MI 3-ring PET/CT (GE Healthcare) installed in Bruges, Belgium. This time-of-flight (TOF) PET camera is based on silicon photomultipliers instead of photomultiplier tubes. METHODS: The NEMA NU2-2012 standard was used to evaluate spatial resolution, sensitivity, image quality (IQ) and count rate curves of the system. Timing and energy resolution were determined. RESULTS: Full width at half maximum (FWHM) of spatial resolution in radial, tangential and axial direction was 4.69, 4.08 and 4.68 mm at 1 cm; 5.58, 4.64 and 5.83 mm at 10 cm; and 7.53, 5.08 and 5.47 mm at 20 cm from the centre of the field of view (FOV) for the filtered backprojection reconstruction. For non-TOF ordered subset expectation maximization (OSEM) reconstruction without point spread function (PSF) correction, FWHM was 3.87, 3.69 and 4.15 mm at 1 cm; 4.80, 3.81 and 4.87 mm at 10 cm; and 7.38, 4.16 and 3.98 mm at 20 cm. Sensitivity was 7.258 cps/kBq at the centre of the FOV and 7.117 cps/kBq at 10-cm radial offset. Contrast recovery (CR) using the IQ phantom for the TOF OSEM reconstruction without PSF correction was 47.4, 59.3, 67.0 and 77.0% for the 10-, 13-, 17- and 22-mm radioactive spheres and 82.5 and 85.1% for the 28- and 37-mm non-radioactive spheres. Background variability (BV) was 16.4, 12.1, 9.1, 6.6, 5.1 and 3.8% for the 10-, 13-, 17-, 22-, 28- and 37-mm spheres. Lung error was 8.5%. Peak noise equivalent count rate (NECR) was 102.3 kcps at 23.0 kBq/ml with a scatter fraction of 41.2%. Maximum accuracy error was 3.88%. Coincidence timing resolution was 375.6 ps FWHM. Energy resolution was 9.3% FWHM. Q.Clear reconstruction significantly improved CR and reduced BV compared with OSEM. CONCLUSION: System sensitivity and NECR are lower and IQ phantom's BV is higher compared with larger axial FOV (AFOV) scanners like the 4-ring discovery MI, as expected from the smaller solid angle of the 3-ring system. The other NEMA performance parameters are all comparable with those of the larger AFOV scanners.

15.
Clin Nucl Med ; 43(12): e479-e481, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30325828

RESUMO

We describe the F-FDG PET/CT findings in a rare case of mesenteric panniculitis caused by systemic lupus. A previous CT had raised suspicion of a space-occupying lesion in the left hypochondrium in a context of aspecific constitutional symptoms and inflammatory parameters. The diagnosis of panniculitis was confirmed at laparoscopic biopsy directed by the PET findings. Follow-up F-FDG PET/CT after 1 month of corticosteroid therapy showed complete disappearance of the abdominal hypermetabolic foci.


Assuntos
Lúpus Eritematoso Sistêmico/diagnóstico por imagem , Paniculite Peritoneal/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Humanos , Lúpus Eritematoso Sistêmico/complicações , Pessoa de Meia-Idade , Paniculite Peritoneal/complicações , Compostos Radiofarmacêuticos
16.
Hell J Nucl Med ; 21(2): 151-152, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30006649

RESUMO

The use of hyaluronic acid nanoshells has been proposed to encapsulate prodrugs and exploit the mechanisms of interactions between living cells, like endocytes or cancer cells and hyaluronic acid, which is a natural component of the extracellular matrix. In this review we describe the potential and the limits of this promising research trend and discuss the theoretical advantages of such an engineering approach. Is it a possible scalability to increase the efficacy and biodegradability of molecules like contrast media and radiotracers especially for neuroradiology and nuclear medicine studies.


Assuntos
Osso e Ossos/diagnóstico por imagem , Eritromelalgia/diagnóstico por imagem , Adolescente , Eritromelalgia/patologia , Feminino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Medronato de Tecnécio Tc 99m/análogos & derivados
17.
Clin Nucl Med ; 42(6): e306-e307, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28368892

RESUMO

We describe a finding of unilaterally decreased binding of I-ioflupane in the basal ganglia in a 78-year-old woman that could be attributed to an underlying developmental venous anomaly.


Assuntos
Veias Cerebrais , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Neostriado/metabolismo , Doenças Vasculares/metabolismo , Idoso , Gânglios da Base/metabolismo , Humanos , Masculino , Nortropanos/metabolismo
18.
Radiol Case Rep ; 12(1): 168-174, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28228904

RESUMO

We describe the bone scan and single-photon emission computed tomography/computed tomography findings in calcific tendinitis of the gluteus maximus and discuss its pathophysiology. Although this tendinopathy is mostly self-limiting, awareness of this disease is important for 2 reasons. First, it may explain acute hip symptoms in patients in the resorptive phase of the calcifications. Second, it should be considered as a differential diagnosis for bone scan hot spots in the vicinity of the gluteus maximus tendon and for cortical erosion seen in that region on X-rays or CT.

19.
Clin Nucl Med ; 42(4): 303-305, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28114227

RESUMO

Prostate-specific membrane antigen (PSMA) is a cell surface glycoprotein which is frequently overexpressed on prostate cancer cells. Ga-PSMA PET/CT plays an increasing role in prostate cancer management. However, growing evidence suggests increased PSMA uptake in a variety of other malignant tumor entities and in some benign lesions. This report describes PSMA uptake in numerous thoracic lymph nodes in a patient with known mediastinal sarcoidosis. Knowledge and recognition of these possibilities are important to avoid scan misinterpretation.


Assuntos
Linfonodos/diagnóstico por imagem , Mediastino/diagnóstico por imagem , Compostos Organometálicos , Compostos Radiofarmacêuticos , Sarcoidose/diagnóstico por imagem , Idoso de 80 Anos ou mais , Ácido Edético/análogos & derivados , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Masculino , Oligopeptídeos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
20.
Clin Nucl Med ; 41(11): 877-878, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27556795

RESUMO

Ga-PSMA plays an increasing role in prostate cancer management, but several instances of false positivity have now been recognized. We present a patient with metastatic prostatic carcinoma who also showed overexpression of PSMA in Paget disease of the humerus on Ga-PSMA PET. This probably relates to bone remodeling and increased vascularity. It is important to be aware of this aspecific uptake because its recognition may avoid overstaging and may alter the therapeutic choice.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Compostos Organometálicos , Osteíte Deformante/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Compostos Radiofarmacêuticos , Adenocarcinoma/complicações , Idoso , Ácido Edético/análogos & derivados , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Masculino , Oligopeptídeos , Osteíte Deformante/complicações , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...