Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 195
Filtrar
1.
Med Clin (Barc) ; 2024 Jun 06.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38849267

RESUMO

Even though a large number of antihypertensive drugs are suitable for hypertension treatment, some new therapeutic targets are recently under development. Most are focused in the treatment of resistant hypertension, added to the drugs currently available for treating such condition. Others have specific particularities in their duration of action, which allows their use once per month or every six months and could become alternatives to the current antihypertensive treatment. Most interesting therapeutic targets are the renin-angiotensin-aldosterone system, through interference with the RNA of the angiotensinogen, the inhibition of brain aminopeptidase III, the inhibition of aldosterone synthase, and new non-steroidal aldosterone receptor antagonists. In addition, dual endothelin receptor antagonists or agonists of the NPR1 receptor, the main effector of natriuretic peptides are other new interesting therapeutic possibilities. In this paper, we review clinical data on the development of the most interesting molecules acting through these new therapeutic targets.

2.
Eur Heart J ; 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38847237

RESUMO

BACKGROUND AND AIMS: Guidelines suggest similar blood pressure (BP) targets in patients with and without diabetes and recommend ambulatory BP monitoring (ABPM) to diagnose and classify hypertension. It was explored whether different levels of ambulatory and office BP and different hypertension phenotypes associate with differences of risk in diabetes and no diabetes. METHODS: This analysis assessed outcome data from the Spanish ABPM Registry in 59 124 patients with complete available data. The associations between office, mean, daytime, and nighttime ambulatory BP with the risk in patients with or without diabetes were explored. The effects of diabetes on mortality in different hypertension phenotypes, i.e. sustained hypertension, white-coat hypertension, and masked hypertension, compared with normotension were studied. Analyses were done with Cox regression analyses and adjusted for demographic and clinical confounders. RESULTS: A total of 59 124 patients were recruited from 223 primary care centres in Spain. The majority had an office systolic BP >140 mmHg (36 700 patients), and 23 128 (40.6%) patients were untreated. Diabetes was diagnosed in 11 391 patients (19.2%). Concomitant cardiovascular (CV) disease was present in 2521 patients (23.1%) with diabetes and 4616 (10.0%) without diabetes. Twenty-four-hour mean, daytime, and nighttime ambulatory BP were associated with increased risk in diabetes and no diabetes, while in office BP, there was no clear association with no differences with and without diabetes. While the relative association of BP to CV death risk was similar in diabetes compared with no diabetes (mean interaction P = .80, daytime interaction P = .97, and nighttime interaction P = .32), increased event rates occurred in diabetes for all ABPM parameters for CV death and all-cause death. White-coat hypertension was not associated with risk for CV death (hazard ratio 0.86; 95% confidence interval 0.72-1.03) and slightly reduced risk for all-cause death in no diabetes (hazard ratio 0.89; confidence interval 0.81-0.98) but without significant interaction between diabetes and no diabetes. Sustained hypertension and masked hypertension in diabetes and no diabetes were associated with even higher risk. There were no significant interactions in hypertensive phenotypes between diabetes and no diabetes and CV death risk (interaction P = .26), while some interaction was present for all-cause death (interaction P = .043) and non-CV death (interaction P = .053). CONCLUSIONS: Diabetes increased the risk for all-cause death, CV, and non-CV death at every level of office and ambulatory BP. Masked and sustained hypertension confer to the highest risk, while white-coat hypertension appears grossly neutral without interaction of relative risk between diabetes and no diabetes. These results support recommendations of international guidelines for strict BP control and using ABPM for classification and assessment of risk and control of hypertension, particularly in patients with diabetes. CLINICAL TRIAL REGISTRATION: Not applicable.

3.
J Hypertens ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38899971

RESUMO

Measuring blood pressure (BP) and investigating arterial hemodynamics are essential in understanding cardiovascular disease and assessing cardiovascular risk. Several methods are used to measure BP in the doctor's office, at home, or over 24 h under ambulatory conditions. Similarly, several noninvasive methods have been introduced for assessing arterial structure and function; these methods differ for the large arteries, the small ones, and the capillaries. Consequently, when studying arterial hemodynamics, the clinician is faced with a multitude of assessment methods whose technical details, advantages, and limitations are sometimes unclear. Moreover, the conditions and procedures for their optimal implementation, and/or the reference normality values for the parameters they yield are not always taken into sufficient consideration. Therefore, a practice guideline summarizing the main methods and their use in clinical practice is needed. This expert group position paper was developed by an international group of scientists after a two-day meeting during which each of the most used methods and techniques for blood pressure measurement and arterial function and structure evaluation were presented and discussed, focusing on their advantages, limitations, indications, normal values, and their pragmatic clinical application.

4.
EBioMedicine ; 103: 105107, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38632024

RESUMO

BACKGROUND: The cardio-ankle vascular index (CAVI) measure of arterial stiffness is associated with prevalent cardiovascular risk factors, while its predictive value for cardiovascular events remains to be established. The aim was to determine associations of CAVI with cardiovascular morbimortality (primary outcome) and all-cause mortality (secondary outcome), and to establish the determinants of CAVI progression. METHODS: TRIPLE-A-Stiffness, an international multicentre prospective longitudinal study, enrolled >2000 subjects ≥40 years old at 32 centres from 18 European countries. Of these, 1250 subjects (55% women) were followed for a median of 3.82 (2.81-4.69) years. FINDINGS: Unadjusted cumulative incidence rates of outcomes according to CAVI stratification were higher in highest stratum (CAVI > 9). Cox regression with adjustment for age, sex, and cardiovascular risk factors revealed that CAVI was associated with increased cardiovascular morbimortality (HR 1.25 per 1 increase; 95% confidence interval, CI: 1.03-1.51) and all-cause mortality (HR 1.37 per 1 increase; 95% CI: 1.10-1.70) risk in subjects ≥60 years. In ROC analyses, CAVI optimal threshold was 9.25 (c-index 0.598; 0.542-0.654) and 8.30 (c-index 0.565; 0.512-0.618) in subjects ≥ or <60 years, respectively, to predict increased CV morbimortality. Finally, age, mean arterial blood pressure, anti-diabetic and lipid-lowering treatment were independent predictors of yearly CAVI progression adjusted for baseline CAVI. INTERPRETATION: The present study identified additional value for CAVI to predict outcomes after adjustment for CV risk factors, in particular for subjects ≥60 years. CAVI progression may represent a modifiable risk factor by treatments. FUNDING: International Society of Vascular Health (ISVH) and Fukuda Denshi, Japan.


Assuntos
Índice Vascular Coração-Tornozelo , Doenças Cardiovasculares , Rigidez Vascular , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Doenças Cardiovasculares/mortalidade , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/etiologia , Estudos Prospectivos , Progressão da Doença , Fatores de Risco , Curva ROC , Adulto , Estudos Longitudinais , Prognóstico , Fatores de Risco de Doenças Cardíacas
5.
J Hypertens ; 42(6): 939-947, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38647124

RESUMO

Recent evidence suggests that an exaggerated blood pressure (BP) response to standing (ERTS) is associated with an increased risk of adverse outcomes, both in young and old individuals. In addition, ERTS has been shown to be an independent predictor of masked hypertension. In the vast majority of studies reporting on the prognostic value of orthostatic hypertension (OHT), the definition was based only on systolic office BP measurements. This consensus statement provides recommendations on the assessment and management of individuals with ERTS and/or OHT. ERTS is defined as an orthostatic increase in SBP at least 20 mmHg and OHT as an ERTS with standing SBP at least 140 mmHg. This statement recommends a standardized methodology to assess ERTS, by considering body and arm position, and the number and timing of BP measurements. ERTS/OHT should be confirmed in a second visit, to account for its limited reproducibility. The second assessment should evaluate BP changes from the supine to the standing posture. Ambulatory BP monitoring is recommended in most individuals with ERTS/OHT, especially if they have high-normal seated office BP. Implementation of lifestyle changes and close follow-up are recommended in individuals with ERTS/OHT and normotensive seated office BP. Whether antihypertensive treatment should be administered in the latter is unknown. Hypertensive patients with ERTS/OHT should be managed as any other hypertensive patient. Standardized standing BP measurement should be implemented in future epidemiological and interventional studies.


Assuntos
Pressão Sanguínea , Hipertensão , Humanos , Hipertensão/fisiopatologia , Hipertensão/diagnóstico , Hipertensão/terapia , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Consenso , Posição Ortostática , Europa (Continente) , Monitorização Ambulatorial da Pressão Arterial/métodos
6.
Med Clin (Barc) ; 2024 Apr 02.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38570293

RESUMO

Ambulatory Blood Pressure Monitoring (ABPM) is considered the best method for obtaining a reliable estimation of the true blood pressure. Average values obtained during the whole 24-hour period, or during daytime and nighttime periods are better correlated with the risk of mortality and cardiovascular disease compared to clinic or office blood pressure. Indeed, nighttime blood pressure, a measure only obtained through ABPM, is the most powerful risk predictor. ABPM is complementary to clinic blood pressure measurement and allows the definition of blood pressure phenotypes, such as "white-coat or masked hypertension, when clinic and ABPM measurements show discrepancy in normal values. Additional potentially relevant features include blood pressure variability, such as nocturnal blood pressure decline, morning surge or short-term variability, as determined by standard deviation or the coefficient of variation.

7.
Hypertension ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38660828

RESUMO

BACKGROUND: Quantification of total cardiovascular risk is essential for individualizing hypertension treatment. This study aimed to develop and validate a novel, machine-learning-derived model to predict cardiovascular mortality risk using office blood pressure (OBP) and ambulatory blood pressure (ABP). METHODS: The performance of the novel risk score was compared with existing risk scores, and the possibility of predicting ABP phenotypes utilizing clinical variables was assessed. Using data from 59 124 patients enrolled in the Spanish ABP Monitoring registry, machine-learning approaches (logistic regression, gradient-boosted decision trees, and deep neural networks) and stepwise forward feature selection were used. RESULTS: For the prediction of cardiovascular mortality, deep neural networks yielded the highest clinical performance. The novel mortality prediction models using OBP and ABP outperformed other risk scores. The area under the curve achieved by the novel approach, already when using OBP variables, was significantly higher when compared with the area under the curve of the Framingham risk score, Systemic Coronary Risk Estimation 2, and Atherosclerotic Cardiovascular Disease score. However, the prediction of cardiovascular mortality with ABP instead of OBP data significantly increased the area under the curve (0.870 versus 0.865; P=3.61×10-28), accuracy, and specificity, respectively. The prediction of ABP phenotypes (ie, white-coat, ambulatory, and masked hypertension) using clinical characteristics was limited. CONCLUSIONS: The receiver operating characteristic curves for cardiovascular mortality using ABP and OBP with deep neural network models outperformed all other risk metrics, indicating the potential for improving current risk scores by applying state-of-the-art machine learning approaches. The prediction of cardiovascular mortality using ABP data led to a significant increase in area under the curve and performance metrics.

8.
J Hypertens ; 42(7): 1197-1202, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38477142

RESUMO

OBJECTIVE: It has been suggested that a blunted nocturnal blood pressure (BP) decline is associated with a poor prognosis. Nevertheless, it remains unclear if an abnormal dipping is deleterious per se or it merely reflects an elevated BP during sleep. We aimed to assess the prognostic value of nocturnal BP decline, with or without concomitant elevated nocturnal BP. METHODS: Vital status and cause of death were obtained from death certificates in 59 124 patients, enrolled in the Spanish ABPM Registry between 2004 and 2014 (median follow-up: 10 years). The association between night-to-day ratio (NDR) and dipping patterns (extreme dippers, dippers, reduced dippers, and risers) with all-cause and cardiovascular mortality were evaluated by Cox-proportional models adjusted for clinical confounders and 24 h blood pressure. RESULTS: NDR was associated with all-cause mortality [hazard ratio for 1SD change: 1.15; 95% confidence interval (CI) 1.13-1.17]. Reduced dippers (1.13; 1.06-1.20) and risers (1.41; 1.32-1.51) were associated with an increased risk of all-cause death, whereas extreme dippers (0.90; 0.79-1.02) were not. Elevated NDR (≥0.9) in the absence of elevated night SBP (<120 mmHg) was associated with an increased risk of death (1.13; 1.04-1.22), as well as elevated night SBP but normal NDR (1.38; 1.26-1.50), and the combination of both abnormalities (1.56; 1.46-1.66). Similar results were obtained for cardiovascular mortality. CONCLUSION: Abnormalities in the circadian pattern are associated with an increased risk of all-cause and cardiovascular mortality. This is maintained even in the absence of nocturnal BP elevation.


Assuntos
Pressão Sanguínea , Doenças Cardiovasculares , Ritmo Circadiano , Humanos , Masculino , Feminino , Pressão Sanguínea/fisiologia , Doenças Cardiovasculares/mortalidade , Doenças Cardiovasculares/fisiopatologia , Pessoa de Meia-Idade , Ritmo Circadiano/fisiologia , Idoso , Monitorização Ambulatorial da Pressão Arterial , Causas de Morte , Hipertensão/mortalidade , Hipertensão/fisiopatologia , Prognóstico
10.
Hypertension ; 81(5): 1125-1131, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38506051

RESUMO

BACKGROUND: The prognostic relevance of short-term blood pressure (BP) variability in hypertension is not clearly established. We aimed to evaluate the association of short-term BP variability, with all-cause and cardiovascular mortality in a large cohort of patients with hypertension. METHODS: We selected 59 124 patients from the Spanish Ambulatory Blood Pressure Monitoring Registry from 2004 to 2014 (median follow-up: 9.7 years). Systolic and diastolic BP SD and coefficient of variation from daytime and nighttime, weighted SD, weighted coefficient of variation, average real variability (mean of differences between consecutive readings), and BP variability ratio (ratio between systolic and diastolic 24-hour SD) were calculated through baseline 24-hour ambulatory BP monitoring. Association with all-cause and cardiovascular mortality were assessed by Cox regression models adjusted for clinical confounders and BP. RESULTS: Patients who died during follow-up had higher values of BP variability compared with those remaining alive. In adjusted models systolic and diastolic daytime and weighted SD and coefficient of variation, average real variability, as well as systolic nighttime SD and BP variability ratio were all significantly associated with all-cause and cardiovascular mortality. Hazard ratios for 1-SD increase in the systolic components ranged from 1.05 to 1.12 for all-cause mortality and from 1.07 to 1.17 for cardiovascular mortality. A daytime SD≥13 mm Hg, a nighttime and a weighted SD≥12 mm Hg, and an average real variability ≥10 mm Hg, all systolic, were independently associated with mortality. CONCLUSIONS: Short-term blood pressure variability shows a relatively weak but significant association with all-cause and cardiovascular mortality in patients with hypertension.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Hipertensão , Humanos , Pressão Sanguínea/fisiologia , Prognóstico , Sistema de Registros
11.
J Hypertens ; 42(2): 260-266, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37796235

RESUMO

BACKGROUND AND AIMS: Whether bedtime versus morning administration of antihypertensive therapy is beneficial on outcomes is controversial. We evaluated the risk of total and cardiovascular mortality in a very large observational cohort of treated hypertensive patients, according to the timing of their usual treatment administration (morning versus evening). METHODS: Vital status and cause of death were obtained from death certificates of 28 406 treated hypertensive patients (mean age 62 years, 53% male individuals), enrolled in the Spanish Ambulatory Blood Pressure Monitoring (ABPM) Registry between 2004 and 2014. Among the 28 406 patients, most (86%) received their medication exclusively in the morning; whilst 13% were treated exclusively in the evening or at bedtime. Follow-up was for a median of 9.7 years and 4345 deaths occurred, of which 1478 were cardiovascular deaths. RESULTS: Using Cox-models adjusted for clinical confounders and 24-h SBP, and compared with patients treated in the morning (reference group), all-cause mortality [hazard ratio 1.01; 95% CI 0.93-1.09) and cardiovascular mortality (hazard ratio 1.04; 95% CI 0.91-1.19) was not significantly different in those receiving evening medication dosing. The results were consistent in all the subgroups of patients analysed. CONCLUSION: In this very large observational study, morning versus bedtime dosing of antihypertensive medication made no difference to the subsequent risk of all-cause or cardiovascular mortality. These findings are in accordance with results from a recent randomized controlled trial and do not support the hypothesis of a specific beneficial effect of night-time antihypertensive treatment dosing on risk of all-cause or cardiovascular death.


Assuntos
Anti-Hipertensivos , Hipertensão , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Anti-Hipertensivos/farmacologia , Monitorização Ambulatorial da Pressão Arterial/métodos , Pressão Sanguínea/fisiologia , Hipertensão/tratamento farmacológico , Sistema de Registros , Ritmo Circadiano/fisiologia
12.
J Clin Med ; 12(19)2023 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-37834811

RESUMO

Blood pressure oscillations during different time scales, known as blood pressure variability (BPV), have become a focus of growing scientific interest. BPV can be measured at long-term (seasonal variability or visit-to-visit), at mid-term (differences in consecutive days or weeks) or at short-term (day-night differences or changes induced by other daily activities and conditions). An increased BPV, either at long, mid or short-term is associated with a poor cardiovascular prognosis independently of the amount of blood pressure elevation. There is scarce evidence on the effect of different antihypertensive treatments on BPV, but some observational and interventional studies suggest that calcium channel blockers in general, and particularly amlodipine, either in monotherapy or combined with renin-angiotensin system blockers, can reduce BPV more efficiently than other antihypertensive drugs or combinations. Nevertheless, there are several aspects of the relationship between BPV, antihypertensive treatment, and clinical outcomes that are still unknown, and more work should be performed before considering BPV as a therapeutical target in clinical practice.

13.
Front Aging Neurosci ; 15: 1251755, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37693650

RESUMO

Clinical and cognitive progression in alpha-synucleinopathies is highly heterogeneous. While some patients remain stable over long periods of time, other suffer early dementia or fast motor deterioration. Sleep disturbances and nocturnal blood pressure abnormalities have been identified as independent risk factors for clinical progression but a mechanistic explanation linking both aspects is lacking. We hypothesize that impaired glymphatic system might play a key role on clinical progression. Glymphatic system clears brain waste during specific sleep stages, being blood pressure the motive force that propels the interstitial fluid through brain tissue to remove protein waste. Thus, the combination of severe sleep alterations, such as REM sleep behavioral disorder, and lack of the physiological nocturnal decrease of blood pressure due to severe dysautonomia may constitute the perfect storm for glymphatic failure, causing increased abnormal protein aggregation and spreading. In Lewy body disorders (Parkinson's disease and dementia with Lewy bodies) the increment of intraneuronal alpha-synuclein and extracellular amyloid-ß would lead to cognitive deterioration, while in multisystemic atrophy, increased pathology in oligodendroglia would relate to the faster and malignant motor progression. We present a research model that may help in developing studies aiming to elucidate the role of glymphatic function and associated factors mainly in alpha-synucleinopathies, but that could be relevant also for other protein accumulation-related neurodegenerative diseases. If the model is proven to be useful could open new lines for treatments targeting glymphatic function (for example through control of nocturnal blood pressure) with the objective to ameliorate cognitive and motor progression in alpha-synucleinopathies.

14.
J Hypertens ; 41(12): 2074-2087, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37303198

RESUMO

BACKGROUND: There is intense effort to develop cuffless blood pressure (BP) measuring devices, and several are already on the market claiming that they provide accurate measurements. These devices are heterogeneous in measurement principle, intended use, functions, and calibration, and have special accuracy issues requiring different validation than classic cuff BP monitors. To date, there are no generally accepted protocols for their validation to ensure adequate accuracy for clinical use. OBJECTIVE: This statement by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability recommends procedures for validating intermittent cuffless BP devices (providing measurements every >30 sec and usually 30-60 min, or upon user initiation), which are most common. VALIDATION PROCEDURES: Six validation tests are defined for evaluating different aspects of intermittent cuffless devices: static test (absolute BP accuracy); device position test (hydrostatic pressure effect robustness); treatment test (BP decrease accuracy); awake/asleep test (BP change accuracy); exercise test (BP increase accuracy); and recalibration test (cuff calibration stability over time). Not all these tests are required for a given device. The necessary tests depend on whether the device requires individual user calibration, measures automatically or manually, and takes measurements in more than one position. CONCLUSION: The validation of cuffless BP devices is complex and needs to be tailored according to their functions and calibration. These ESH recommendations present specific, clinically meaningful, and pragmatic validation procedures for different types of intermittent cuffless devices to ensure that only accurate devices will be used in the evaluation and management of hypertension.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Humanos , Pressão Sanguínea/fisiologia , Hipertensão/diagnóstico , Esfigmomanômetros , Monitores de Pressão Arterial
15.
J Hypertens ; 41(12): 2088-2094, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37303225

RESUMO

OBJECTIVE: To develop scientific consensus recommendations for the optimal design and functions of different types of blood pressure (BP) measuring devices used in clinical practice for the detection, management, and long-term follow-up of hypertension. METHODS: A scientific consensus meeting was performed by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability and STRIDE BP (Science and Technology for Regional Innovation and Development in Europe) during the 2022 Scientific Meeting of the ESH in Athens, Greece. Manufacturers were also invited to provide their feedback on BP device design and development. Thirty-one international experts in clinical hypertension and BP monitoring contributed to the development of consensus recommendations on the optimal design of BP devices. STATEMENT: International consensus was reached on the requirements for the design and features of five types of BP monitors, including office (or clinic) BP monitors, ambulatory BP monitors, home BP monitors, home BP telemonitors, and kiosk BP monitors for public spaces. For each device type "essential" requirements (must have), and "optional" ones (may have) are presented, as well as additional comments on the optimal device design and features. CONCLUSIONS: These consensus recommendations aim at providing manufacturers of BP devices with the requirements that are considered mandatory, or optional, by clinical experts involved in the detection and management of hypertension. They are also directed to administrative healthcare personnel involved in the provision and purchase of BP devices so that they can recommend the most appropriate ones.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Humanos , Pressão Sanguínea , Reprodutibilidade dos Testes , Hipertensão/diagnóstico , Hipertensão/terapia , Esfigmomanômetros , Monitorização Ambulatorial da Pressão Arterial
16.
Lancet ; 401(10393): 2041-2050, 2023 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-37156250

RESUMO

BACKGROUND: Ambulatory blood pressure provides a more comprehensive assessment than clinic blood pressure, and has been reported to better predict health outcomes than clinic or home pressure. We aimed to examine associations of clinic and 24-h ambulatory blood pressure with all-cause and cardiovascular mortality in a large cohort of primary care patients referred for assessment of hypertension. METHODS: We did an observational cohort study using clinic and ambulatory blood pressure data obtained from March 1, 2004, to Dec 31, 2014, from the Spanish Ambulatory Blood Pressure Registry. This registry included patients from 223 primary care centres from the Spanish National Health System in all 17 regions of Spain. Mortality data (date and cause) were ascertained by a computerised search of the vital registry of the Spanish National Institute of Statistics. Complete data were available for age, sex, all blood pressure measures, and BMI. For each study participant, follow-up was from the date of their recruitment to the date of death or Dec 31, 2019, whichever occurred first. Cox models were used to estimate associations between usual clinic or ambulatory blood pressure and mortality, adjusted for confounders and additionally for alternative measures of blood pressure. For each measure of blood pressure, we created five groups (ie, fifths) defined by quintiles of that measure among those who subsequently died. FINDINGS: During a median follow-up of 9·7 years, 7174 (12·1%) of 59 124 patients died, including 2361 (4·0%) from cardiovascular causes. J-shaped associations were observed for several blood pressure measures. Among the top four baseline-defined fifths, 24-h systolic blood pressure was more strongly associated with all-cause death (hazard ratio [HR] 1·41 per 1 - SD increment [95% CI 1·36-1·47]) than clinic systolic blood pressure (1·18 [1·13-1·23]). After adjustment for clinic blood pressure, 24-h blood pressure remained strongly associated with all-cause deaths (HR 1·43 [95% CI 1·37-1·49]), but the association between clinic blood pressure and all-cause death was attenuated when adjusted for 24-h blood pressure (1·04 [1·00-1·09]). Compared with the informativeness of clinic systolic blood pressure (100%), night-time systolic blood pressure was most informative about risk of all-cause death (591%) and cardiovascular death (604%). Relative to blood pressure within the normal range, elevated all-cause mortality risks were observed for masked hypertension (HR 1·24 [95% CI 1·12-1·37]) and sustained hypertension (1·24 [1·15-1·32]), but not white-coat hypertension, and elevated cardiovascular mortality risks were observed for masked hypertension (1·37 [1·15-1·63]) and sustained hypertension (1·38 [1·22-1·55]), but not white-coat hypertension. INTERPRETATION: Ambulatory blood pressure, particularly night-time blood pressure, was more informative about the risk of all-cause death and cardiovascular death than clinic blood pressure. FUNDING: Spanish Society of Hypertension, Lacer Laboratories, UK Medical Research Council, Health Data Research UK, National Institute for Health and Care Research Biomedical Research Centres (Oxford and University College London Hospitals), and British Heart Foundation Centre for Research Excellence.


Assuntos
Hipertensão , Hipertensão Mascarada , Humanos , Pressão Sanguínea/fisiologia , Hipertensão Mascarada/complicações , Monitorização Ambulatorial da Pressão Arterial , Hipertensão/complicações , Estudos de Coortes
18.
J Hypertens ; 41(5): 811-818, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36883464

RESUMO

OBJECTIVE: Automated cuff blood pressure (BP) devices are widely used for ambulatory, home, and office BP measurement. However, an automated device, which is accurate in the general adult population may be inaccurate in some special populations. A 2018 Collaborative Statement by the US Association for the Advancement of Medical Instrumentation, the European Society of Hypertension, and the International Organization for Standardization (ISO) considered three special populations requiring separate validation (age <3 years, pregnancy, and atrial fibrillation). An ISO Task Group was appointed to identify evidence for additional special populations. METHOD: Evidence on potential special populations was identified from the STRIDE BP database, which performs systematic PubMed searches for published validation studies of automated cuff BP monitors. Devices that passed in a general population, but failed in potential special populations were identified. RESULTS: Of 338 publications (549 validations, 348 devices) in the STRIDE BP database, 29 publications (38 validations, 25 devices) involved 4 potential special populations: (i) age 12-18 years: 3 of 7 devices failed but passed in a general population; (ii) age more than 65 years: 1 of 11 devices failed but passed in a general population; (iii) diabetes type-2: 4 devices (all passed); (iv) chronic kidney disease: 2 of 7 devices failed but passed in a general population. CONCLUSION: Some evidence suggest that the automated cuff BP devices may have different accuracy in adolescents and in patients with chronic kidney disease than in the general population. More research is needed to confirm these findings and investigate other potential special populations.


Assuntos
Hipertensão , Insuficiência Renal Crônica , Adulto , Feminino , Gravidez , Humanos , Adolescente , Pré-Escolar , Criança , Idoso , Monitores de Pressão Arterial , Determinação da Pressão Arterial , Hipertensão/diagnóstico , Padrões de Referência , Pressão Sanguínea
19.
J Clin Med ; 12(4)2023 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-36836044

RESUMO

There is scarce evidence for the prognostic importance of hemodynamic measures, such as blood pressure (BP), BP variability, and arterial stiffness, in the very elderly population with advanced chronic conditions. We aimed to evaluate the prognostic importance of 24 h BP, BP variability, and arterial stiffness in a cohort of very elderly patients admitted to the hospital due to a decompensated chronic disease. We studied 249 patients older than 80 (66% women; 60% congestive heart failure). Noninvasive 24 h monitoring was used to determine 24 h brachial and central BP, BP and heart rate variabilities, aortic pulse wave velocity, and BP variability ratios during admission. The primary outcome was 1-year mortality. Aortic pulse wave velocity (3.3 times for each SD increase) and BP variability ratio (31% for each SD increase) were associated with 1-year mortality, after adjustments for clinical confounders. Increased systolic BP variability (38% increase for each SD change) and reduced heart rate variability (32% increase for each SD change) also predicted 1-year mortality. In conclusion, increased aortic stiffness and BP and heart rate variabilities predict 1-year mortality in very elderly patients with decompensated chronic conditions. Measurements of such estimates could be useful in the prognostic evaluation of this specific population.

20.
J Hypertens ; 41(4): 527-544, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36723481

RESUMO

Blood pressure is not a static parameter, but rather undergoes continuous fluctuations over time, as a result of the interaction between environmental and behavioural factors on one side and intrinsic cardiovascular regulatory mechanisms on the other side. Increased blood pressure variability (BPV) may indicate an impaired cardiovascular regulation and may represent a cardiovascular risk factor itself, having been associated with increased all-cause and cardiovascular mortality, stroke, coronary artery disease, heart failure, end-stage renal disease, and dementia incidence. Nonetheless, BPV was considered only a research issue in previous hypertension management guidelines, because the available evidence on its clinical relevance presents several gaps and is based on heterogeneous studies with limited standardization of methods for BPV assessment. The aim of this position paper, with contributions from members of the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability and from a number of international experts, is to summarize the available evidence in the field of BPV assessment methodology and clinical applications and to provide practical indications on how to measure and interpret BPV in research and clinical settings based on currently available data. Pending issues and clinical and methodological recommendations supported by available evidence are also reported. The information provided by this paper should contribute to a better standardization of future studies on BPV, but should also provide clinicians with some indications on how BPV can be managed based on currently available data.


Assuntos
Doença da Artéria Coronariana , Hipertensão , Humanos , Pressão Sanguínea , Relevância Clínica , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico , Hipertensão/complicações , Determinação da Pressão Arterial , Doença da Artéria Coronariana/complicações , Monitorização Ambulatorial da Pressão Arterial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...