Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Breastfeed Med ; 18(11): 881-887, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37971376

RESUMO

Introduction: Breast engorgement (BE) is a problem that affects many women, especially in the first days of breastfeeding, producing inflammatory symptoms. Nonpharmacological therapies are inexpensive, safe, and can produce symptom relief. Objective: This study aims to analyze the safety of therapeutic ultrasound regarding possible risks of overheating and the effects of its use alone and associated with lymphatic drainage (LD) in women. Material and Methods: Effectiveness is measured through thermography, visual analog scale, and six-point scale of BE. This is a nonrandomized clinical trial with a sample of 34 in the ultrasound group (G1), 28 in the ultrasound and LD group (G2), and 37 in the control group (G3). Results: The mean reduction for engorgement was 1.3 ± 0.8 to G1, 1.4 ± 1.0 to G2, and 1.2 ± 0.9 to G3 according to the six-point scale. The mean reduction for pain level was 3.6 ± 2.1 to G1, 4.0 ± 3.1 to G2, and 4.0 ± 2.2 to G3 according to the visual analogue scale. Conclusion: It was observed that all therapies were effective in reducing the level of engorgement, according to the six-point scale. However, combined ultrasound and LD therapy has been shown to be more effective in reducing the level of pain. Brazilian Registry of Clinical Trials (RBR-6btb6zz).


Assuntos
Transtornos da Lactação , Terapia por Ultrassom , Feminino , Humanos , Aleitamento Materno , Transtornos da Lactação/terapia , Dor , Drenagem
2.
Ultrasonics ; 90: 144-152, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29966842

RESUMO

The purpose of this work was to obtain an anthropomorphic phantom with acoustic properties similar to those of breast tissue, possessing lactiferous duct-like structures, which would be a first for this type of phantom. Breast lesions usually grow in glandular tissues or lactiferous ducts. Shape variations in these structures are detectable by using ultrasound imaging. To increase early diagnosis, it is important to develop computer-aided diagnosis (CAD) systems and improve medical training. Using tissue-like materials that mimic known internal structures can help achieve both of these goals. However, most breast ultrasound phantoms described in the literature emulate only fat tissues and lesion-like masses. In addition, commercially available phantoms claim to be realistic, but do not contain lactiferous duct structures. In this work, we collected reference images from both breasts of ten healthy female volunteers aged between 20 and 30 years using a 10 MHz linear transducer of a B-mode medical ultrasound system. Histograms of the grey scale distribution of each tissue component of interest, the grey level means, and standard deviations of the regions of interest were obtained. Phantoms were produced using polyvinyl chloride plastisol (PVCP) suspensions. The lactiferous duct-like structures were prepared using pure PVCP. Solid scatterers, such as alumina (mesh #100) and graphite powders (mesh #140) were added to the phantom matrix to mimic glandular and fat tissue, respectively. The phantom duct-like structure diameters observed on B-mode images (1.92 mm ±â€¯0.44) were similar to real measures obtained with a micrometer (2.08 mm ±â€¯0.23). The phantom ducts are easy to produce and are largely stable for at least one year. This phantom allows the researchers to elaborate the structure at their will and may be used in training and as a reference for development of CAD systems.


Assuntos
Mama/anatomia & histologia , Mama/diagnóstico por imagem , Glândulas Mamárias Humanas/anatomia & histologia , Glândulas Mamárias Humanas/diagnóstico por imagem , Imagens de Fantasmas , Plastificantes/química , Cloreto de Polivinila/química , Ultrassonografia Mamária/métodos , Feminino , Humanos , Teste de Materiais , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Ultrasonics ; 70: 98-106, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27153374

RESUMO

Ultrasonic phantoms are objects that mimic some features of biological tissues, allowing the study of their interactions with ultrasound (US). In the diagnostic-imaging field, breast phantoms are an important tool for testing performance and optimizing US systems, as well as for training medical professionals. This paper describes the design and manufacture of breast lesions by using polyvinyl chloride plastisol (PVCP) as the base material. Among the materials available for this study, PVCP was shown to be stable, durable, and easy to handle. Furthermore, it is a nontoxic, nonpolluting, and low-cost material. The breast's glandular tissue (image background) was simulated by adding graphite powder with a concentration of 1% to the base material. Mixing PVCP and graphite powder in differing concentrations allows one to simulate lesions with different echogenicity patterns (anechoic, hypoechoic, and hyperechoic). From this mixture, phantom materials were obtained with speed of sound varying from 1379.3 to 1397.9ms(-1) and an attenuation coefficient having values between 0.29 and 0.94dBcm(-1) for a frequency of 1MHz at 24°C. A single layer of carnauba wax was added to the lesion surface in order to evaluate its applicability for imaging. The images of the phantoms were acquired using commercial ultrasound equipment; a specialist rated the images, elaborating diagnoses representative of both benign and malignant lesions. The results indicated that it was possible to easily create a phantom by using low-cost materials, readily available in the market and stable at room temperature, as the basis of ultrasonic phantoms that reproduce the image characteristics of fatty breast tissue and typical lesions of the breast.


Assuntos
Materiais Biomiméticos/química , Neoplasias da Mama/diagnóstico por imagem , Mamografia/instrumentação , Imagens de Fantasmas , Plastificantes/química , Cloreto de Polivinila/química , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Teste de Materiais , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...