Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Pediatr Crit Care Med ; 24(8): 652-661, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37092829

RESUMO

OBJECTIVES: Diaphragm ultrasound is a novel alternative to esophageal pressure measurements in the evaluation of diaphragm function and activity, but data about its reliability in a pediatric setting are lacking. We aimed to compare the esophageal pressure swing (∆P es , gold standard) with the diaphragmatic thickening fraction (DTF) as a measure of inspiratory effort in sedated children. Additionally, we studied the effect of positive end-expiratory pressure (PEEP) on the end-expiratory thickness of the diaphragm (DT ee ). DESIGN: Prospective open-label non-randomized interventional physiological cohort study. SETTING: Operating room in tertiary academic hospital. PATIENTS: Children 28 days to 13 years old scheduled for elective surgery with general anesthesia, spontaneously breathing through a laryngeal mask airway, were eligible for inclusion. Exclusion criteria were disorders or previous surgery of the diaphragm, anticipated difficult airway or acute cardiopulmonary disease. All measurements were performed prior to surgery. INTERVENTIONS: Patients were subjected to different levels of respiratory load, PEEP and anesthetic depth in a total of seven respiratory conditions. MEASUREMENTS AND MAIN RESULTS: The esophageal pressure and diaphragm thickening fraction were simultaneously recorded for five breaths at each respiratory condition. The relation between ∆P es and DTF was studied in a mixed model. We analyzed 407 breaths in 13 patients. Both DTF ( p = 0.03) and ∆Pes ( p = 0.002) could detect respiratory activity, and ∆P es and DTF were associated across respiratory conditions ( p < 0.001; R2 = 31%). With increasing inspiratory load, ∆P es increased significantly, while DTF did not ( p = 0.08). Additionally, DT ee did not differ significantly between 10, 5, and 0 cm H 2 O PEEP ( p = 0.08). CONCLUSIONS: In spontaneously breathing sedated children and across different respiratory conditions, DTF could differentiate minimal or no inspiratory effort from substantial inspiratory effort and was associated with ∆P es . Increased efforts resulted in higher ∆P es but not larger DTF.


Assuntos
Diafragma , Respiração Artificial , Humanos , Criança , Diafragma/diagnóstico por imagem , Estudos Prospectivos , Estudos de Viabilidade , Reprodutibilidade dos Testes , Estudos de Coortes , Respiração Artificial/métodos
3.
Anesth Analg ; 137(4): 841-849, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36729514

RESUMO

BACKGROUND: Increased intra-abdominal pressure during laparoscopy induces atelectasis. Positive end-expiratory pressure (PEEP) can alleviate atelectasis but may cause hyperinflation. Cyclic opening of collapsed alveoli and hyperinflation can lead to ventilator-induced lung injury and postoperative pulmonary complications. We aimed to study the effect of PEEP on atelectasis, lung stress, and hyperinflation during laparoscopy in the head-down (Trendelenburg) position. METHODS: An open-label, repeated-measures, interventional, physiological cohort trial was designed. All participants were recruited from a single tertiary Belgian university hospital. Twenty-three nonobese patients scheduled for laparoscopy in the Trendelenburg position were recruited.We applied a decremental PEEP protocol: 15 (high), 10 and 5 (low) cm H 2 O. Atelectasis was studied with the lung ultrasound score, the end-expiratory transpulmonary pressure, the arterial oxygen partial pressure to fraction of inspired oxygen concentration (P ao2 /Fi o2 ) ratio, and the dynamic respiratory system compliance. Global hyperinflation was evaluated by dead space volume, and regional ventilation was evaluated by lung ultrasound. Lung stress was estimated using the transpulmonary driving pressure and dynamic compliance. Data are reported as medians (25th-75th percentile). RESULTS: At 15, 10, and 5 cm H 2 O PEEP, the respective measurements were: lung ultrasound scores (%) 11 (0-22), 27 (11-39), and 53 (42-61) ( P < .001); end-expiratory transpulmonary pressures (cm H 2 O) 0.9 (-0.6 to 1.7), -0.3 (-2.0 to 0.7), and -1.9 (-4.6 to -0.9) ( P < .001); P ao2 /Fi o2 ratios (mm Hg) 471 (435-538), 458 (410-537), and 431 (358-492) ( P < .001); dynamic respiratory system compliances (mL/cm H 2 O) 32 (26-36), 30 (25-34), and 27 (22-30) ( P < .001); driving pressures (cm H 2 O) 8.2 (7.5-9.5), 9.3 (8.5-11.1), and 11.0 (10.3-12.2) ( P < .001); and alveolar dead space ventilation fractions (%) 10 (9-12), 10 (9-12), and 9 (8-12) ( P = .23). The lung ultrasound score was similar between apical and basal lung regions at each PEEP level ( P = .76, .37, and .76, respectively). CONCLUSIONS: Higher PEEP levels during laparoscopy in the head-down position facilitate lung-protective ventilation. Atelectasis and lung stress are reduced in the absence of global alveolar hyperinflation.


Assuntos
Laparoscopia , Atelectasia Pulmonar , Lesão Pulmonar Induzida por Ventilação Mecânica , Humanos , Estudos de Coortes , Decúbito Inclinado com Rebaixamento da Cabeça , Laparoscopia/efeitos adversos , Oxigênio , Atelectasia Pulmonar/diagnóstico por imagem , Atelectasia Pulmonar/etiologia , Atelectasia Pulmonar/prevenção & controle , Volume de Ventilação Pulmonar
4.
Intensive Care Med Exp ; 10(1): 19, 2022 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-35608696

RESUMO

BACKGROUND: Flow-controlled ventilation (FCV), a novel mode of mechanical ventilation characterised by constant flow during active expiration, may result in more efficient alveolar gas exchange, better lung recruitment and might be useful in limiting ventilator-induced lung injury. However, data regarding FCV in mechanically ventilated patients with acute lung injury or acute respiratory distress syndrome (ARDS) are scarce. OBJECTIVES: We hypothesised that the use of FCV is feasible and would improve oxygenation in moderate COVID-19 ARDS compared to conventional ventilation. DESIGN: Open-label repeated-measures controlled trial. SETTING: From February to April 2021, patients with moderate COVID-19 ARDS were recruited in a tertiary referral intensive care unit. PATIENTS: Patients with moderate ARDS (PaO2/FIO2 ratio 100-200 mmHg, SpO2 88-94% and PaO2 60-80 mmHg) were considered eligible. Exclusion criteria were: extremes of age (< 18 years, > 80 years), obesity (body mass index > 40 kg/m2), prone positioning at the time of intervention, mechanical ventilation for more than 10 days and extracorporeal membrane oxygenation. Eleven patients were recruited. INTERVENTION: Participants were ventilated in FCV mode for 30 min, and subsequently in volume-control mode (VCV) for 30 min. MAIN OUTCOME MEASURES: Feasibility of FCV to maintain oxygenation was assessed by the PaO2/FiO2 ratio (mmHg) as a primary outcome parameter. Secondary outcomes included ventilator parameters, PaCO2 and haemodynamic data. All adverse events were recorded. RESULTS: FCV was feasible in all patients and no adverse events were observed. There was no difference in the PaO2/FIO2 ratio after 30 min of ventilation in FCV mode (169 mmHg) compared to 30 min of ventilation in VCV mode subsequently (168 mmHg, 95% CI of pseudo-medians (- 10.5, 3.6), p = 0.56). The tidal volumes (p < 0.01) and minute ventilation were lower during FCV (p = 0.01) while PaCO2 was similar at the end of the 30-min ventilation periods (p = 0.31). Mean arterial pressure during FCV was comparable to baseline. CONCLUSIONS: Thirty minutes of FCV in patients with moderate COVID-19 ARDS receiving neuromuscular blocking agents resulted in similar oxygenation, compared to VCV. FCV was feasible and did not result in adverse events. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT04894214.

5.
Acta Chir Belg ; 122(5): 312-320, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33150853

RESUMO

BACKGROUND: Postoperative cardio-surgical haemostatic management is centre-specific and experience-based, which leads to a variability in patient care. This study aimed to identify which postoperative haemostatic interventions may reduce the need for reoperation after cardiac surgery in adults. METHODS: A retrospective case-control study in a tertiary centre. Adult, elective, primary cardiac surgical patients were selected (n = 2098); cases (n = 42) were patients who underwent reoperation within 72 h after the initial surgery. Interventions administered to control surgical bleeding were compared for the need to re-operate using multiple logistic regression. RESULTS: Rate of cardiac surgical reoperation was 2% in the study population. Three variables were found to be associated with cardiac reoperation: preoperative administration of fresh frozen plasma (OR 5.45, CI 2.34-12.35), cumulative volume of chest tube drainage and cumulative count of packed red blood cells transfusion on ICU (OR 1.98, CI 1.56-2.51). CONCLUSION: No significant difference among specific types of postoperative haemostatic interventions was found between patients who needed reoperation and those who did not. Perioperative transfusion of fresh frozen plasma, postoperative transfusion of packed cells and cumulative volume of chest tube drainage were associated with reoperation after cardiac surgery. These variables could help predict the need for reoperation.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Hemostáticos , Adulto , Perda Sanguínea Cirúrgica , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos de Casos e Controles , Humanos , Reoperação , Estudos Retrospectivos
6.
Eur J Pharmacol ; 816: 3-13, 2017 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-28483459

RESUMO

An ideal animal model of atherosclerosis resembles human anatomy and pathophysiology and has the potential to be used in medical and pharmaceutical research to obtain results that can be extrapolated to human medicine. Moreover, it must be easy to acquire, can be maintained at a reasonable cost, is easy to handle and shares the topography of the lesions with humans. In general, animal models of atherosclerosis are based on accelerated plaque formation due to a cholesterol-rich/Western-type diet, manipulation of genes involved in the cholesterol metabolism, and the introduction of additional risk factors for atherosclerosis. Mouse and rabbit models have been mostly used, followed by pigs and non-human primates. Each of these models has its advantages and limitations. The mouse has become the predominant species to study experimental atherosclerosis because of its rapid reproduction, ease of genetic manipulation and its ability to monitor atherogenesis in a reasonable time frame. Both Apolipoprotein E deficient (ApoE-/-) and LDL-receptor (LDLr) knockout mice have been frequently used, but also ApoE/LDLr double-knockout, ApoE3-Leiden and PCSK9-AAV mice are valuable tools in atherosclerosis research. However, a great challenge was the development of a model in which intra-plaque microvessels, haemorrhages, spontaneous atherosclerotic plaque ruptures, myocardial infarction and sudden death occur consistently. These features are present in ApoE-/-Fbn1C1039G+/- mice, which can be used as a validated model in pre-clinical studies to evaluate novel plaque-stabilizing drugs.


Assuntos
Aterosclerose , Modelos Animais de Doenças , Animais , Aterosclerose/genética , Aterosclerose/metabolismo , Aterosclerose/patologia , Placa Aterosclerótica/genética , Placa Aterosclerótica/metabolismo , Placa Aterosclerótica/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...