Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Interv Card Electrophysiol ; 67(2): 341-351, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37599321

RESUMO

BACKGROUND: Left bundle branch area pacing (LBBAP) is an emerging cardiac pacing modality that preserves fast electrical activation of the ventricles and provides very good electrical measures. Little is known on mechanical ventricular activation during this pacing modality. METHODS: We prospectively enrolled patients receiving LBBAP. Electrocardiographic and electrical parameters were evaluated at implantation, < 24 h and 3 months. Transthoracic echocardiography with strain analysis was performed at baseline and after 3 months, when ventricular mechanical activation and synchrony were analyzed by time-to-peak standard deviation (TPSD) of strain curves for both ventricles. Intraventricular left ventricular (LV) dyssynchrony was investigated by LV TPSD and interventricular dyssynchrony by left ventricle-right ventricle TPSD (LV-RV TPSD). RESULTS: We screened 58 patients with permanent pacing indication who attempted LBBAP. Procedural success was obtained in 56 patients (97%). Strain data were available in 50 patients. QRS duration was 124.1 ± 30.7 ms at baseline, while paced QRS duration was 107.7 ± 13.6 ms (p < 0.001). At 3 months after LBBAP, left ventricular ejection fraction (LVEF) increased from 52.9 ± 10.6% at baseline to 56.9 ± 8.4% (p = 0.004) and both intraventricular LV dyssynchrony and interventricular dyssynchrony significantly improved (LV TPSD reduction from 38.2 (13.6-53.9) to 15.1 (8.3-31.5), p < 0.001; LV-RV TPSD from 27.9 (10.2-41.5) to 13.9 (4.3-28.7), p = 0.001). Ameliorations with LBBAP were consistent in all subgroups, irrespective of baseline QRS duration, types of intraventricular conduction abnormalities, and LVEF. CONCLUSIONS: Echocardiographic strain analysis shows that LBBAP determines a fast and synchronous biventricular contraction with a stereotype mechanical activation, regardless of baseline QRS duration, pattern, and LV function.


Assuntos
Estimulação Cardíaca Artificial , Ventrículos do Coração , Humanos , Ventrículos do Coração/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda , Ecocardiografia , Eletrocardiografia , Resultado do Tratamento
2.
J Electrocardiol ; 81: 123-131, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37688842

RESUMO

BACKGROUND: In patients with a type 2 or 3 Brugada pattern, the pharmacological (IC drugs) induction of a type 1 pattern confirms the diagnosis of Brugada syndrome. OBJECTIVE: To evaluate the value of various ECG markers in predicting IC drug test results. METHODS: We retrospectively analysed 443 consecutive patients referred to our Center (from January 2010 to December 2019) to undergo Ajmaline/Flecainide testing; all had a type 2 or 3 Brugada pattern or were relatives with Brugada syndrome. Clinical parameters and ECG markers (r1V1 and SV6 duration and amplitude, QRSV1/QRSV6 duration, V1 and V2 ST amplitude) were independently evaluated for their association to pharmacological test positivity, and a logistic regression model was applied. RESULTS: The drug test was positive in 151 (34%) patients. On multivariate logistic regression analysis, age > 45 years, female gender, HR >60 bpm, QRSV1/QRSV6 duration >1 and non-isoelectric pattern in V2 were associated with a positive test. The percentage of patients who tested positive increased according to the presence of the above ECG markers (from 11.3% in the absence to 57.6% in the presence of both factors). During long-term follow-up, the clinical event rate was higher in patients with predictive ECG markers and very low in those without. CONCLUSIONS: In our population we confirmed the ability of QRSV1/QRSV6 duration >1 and of a non-isoelectric pattern in V2 to predict a pharmacologically induced type 1 Brugada pattern. Patients with neither of these ECG markers had a rather low event rate during follow-up.


Assuntos
Síndrome de Brugada , Humanos , Feminino , Pessoa de Meia-Idade , Síndrome de Brugada/complicações , Estudos Retrospectivos , Eletrocardiografia/métodos , Ajmalina/efeitos adversos , Flecainida
3.
Pacing Clin Electrophysiol ; 46(9): 1092-1098, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37428835

RESUMO

BACKGROUND: Automated threshold measurements (ATM) and output adaptation improved safety and follow-up of cardiac implantable devices (CIED) in the last years. These algorithms were validated for conventional cardiac pacing; however, they were not suitable for permanent His Pacing. Left bundle branch area pacing (LBBAP) is an emerging technique to obtain physiologic cardiac stimulation; we tried to assess if ATM could be applied to this setting. METHODS: Consecutive patients receiving ATM-capable CIED and LBBAP in our hospital were enrolled in this prospective, observational trial; they were evaluated 3 months after implant, comparing pacing thresholds manually assessed and obtained via ATM. Subsequent remote follow-up was carried on when available. RESULTS: Forty-five patients were enrolled. ATM for LBBAP lead provided consistent results in all the patients and was therefore activated; mean value of manually obtained LBBAP capture threshold was 0.66 ± 0.19 V versus ATM of 0.64 ± 0.19 V. TOST analysis showed equivalence of the two measures (p = .66). At subsequent follow-up (mean follow up 7.7 ± 3.2 months), ATM was effective in assessing pacing thresholds and no clinical adverse event was observed. CONCLUSIONS: ATM algorithms proved equivalent to manual testing in determining capture threshold and were reliably employed in patients receiving LBBAP CIED.


Assuntos
Sistema de Condução Cardíaco , Septo Interventricular , Humanos , Projetos Piloto , Estudos Prospectivos , Doença do Sistema de Condução Cardíaco , Algoritmos , Eletrocardiografia , Estimulação Cardíaca Artificial , Fascículo Atrioventricular , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 34(6): 1441-1451, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37161936

RESUMO

INTRODUCTION: In patients receiving conduction system pacing (CSP), it is not well established how to program the sensed atrioventricular delay (sAVD), with respect to the type of capture obtained (selective, nonselective His-bundle [HB] capture or left bundle branch [LBB] capture). The aim of this study was to acutely assess the effectiveness of an electrophysiology (EP)-guided method for sAVD optimization by comparing it with the echocardiogram-guided optimization. METHODS AND RESULTS: Consecutive patients undergoing HB or LBB pacing were enrolled. The EP-guided sAVD was defined as the sAVD leading to a PR interval of 150 ms on surface electrocardiogram (ECG). In HB pacing patients, EP-guided sAVD was obtained subtracting the time from the onset of the P wave on ECG to the local atrial electrogram (EGM) recorded by the atrial lead (right atrial sensing latency, RASL) and the His-ventricular interval from 150 ms; in LBB pacing patients, subtracting RASL from 150 ms. Transmitral flow assessment by pulsed wave Doppler was used to find the echo-optimized sAVD by a modified iterative method. The discordance between the EP-guided and the echo-optimized sAVD was recorded. RESULTS: Seventy-one patients were enrolled: 12 with selective, 32 nonselective HB capture, and 27 LBB capture. Overall, the rate of concordance between the EP-guided and the echo-optimized sAVD was 71.8%, with no significant differences between the three groups. CONCLUSION: In CSP patients, an optimal sAVD can be programmed, in more than 70% of cases, considering only simple EGM intervals to obtain a physiological PR interval on surface ECG.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/terapia , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco , Fascículo Atrioventricular , Eletrocardiografia/métodos
5.
J Clin Med ; 11(4)2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35207259

RESUMO

There are no data on procedure-related bleeding outcome with non-vitamin K antagonist anticoagulants (NOACs) versus vitamin K antagonist anticoagulants (VKAs) in patients with atrial fibrillation (AF) undergoing cardiac implantable electronic device (CIED) intervention. Our aim was to evaluate whether NOACs have a safety benefit even in terms of fewer hemorrhagic complications at the site of CIED implant. Consecutive AF patients receiving NOACs or VKAs at the time of CIED procedure were included in this observational, retrospective, and monocentric investigation. Primary endpoint was the incidence of post-intervention pocket hematoma. A total of 311 patients were enrolled, 146 on NOACs, and 165 on VKAs. The incidence of pocket hematoma was 3.4% in the NOAC versus 13.3% in the VKA group (p = 0.002). Primary outcome-free survival at 30-days was 96.6% in patients on NOACs and 86.0% in those on VKAs (p = 0.019). Multivariate analysis, adjusted by propensity-score calculation of inverse-probability-weighting, showed a significantly lower occurrence of pocket hematoma in patients receiving NOACs versus VKAs (HR 0.35, 95% CI 0.13-0.96, p = 0.042). Such NOACs benefit was confirmed versus patients on VKAs without peri-procedural bridging with low-molecular-weight heparin (HR 0.34, 95% CI 0.11-0.99, p = 0.048). The incidence of pocket infection, surgical pocket evacuation, ischemic events, and major bleeding complications at 30 days (secondary endpoints) was similar in the two groups. In conclusion, our data suggest that, among patients with AF undergoing implantable cardiac defibrillator or pacemaker intervention, the use of NOACs versus VKAs may be associated with significant reduction of post-procedural pocket hematoma, regardless of bridging with low-molecular-weight heparin in the VKA group. These results are hypothesis generating and need to be confirmed in a specific randomized study.

6.
J Cardiovasc Med (Hagerstown) ; 23(1): 22-27, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34545009

RESUMO

AIMS: The coronavirus disease-19 (COVID-19) outbreak has been recently associated with lower hospitalization rates for acute coronary syndromes. Aim of the study was to investigate whether a similar behaviour is observed in admissions for urgent pacemaker implant. METHODS: This retrospective study included 1315 patients from 18 hospitals in Northern Italy with a high number of COVID-19 cases. Hospitalization rates for urgent pacemaker implant were compared between the following periods: 20 February to 20 April 2020 (case period); from 1 January to 19 February 2020 (intra-year control period); from 20 February to 20 April 2019 (inter-year control period). RESULTS: The incidence rate of urgent implants was 5.0/day in the case period, 6.0/day in the intra-year control period and 5.8/day in the inter-year control period. Incidence rate in the case period was significantly lower than both the intra-year [incidence rate ratio (IRR): 0.81, 95% CI 0.67-0.99, P = 0.040] and inter-year control periods (IRR: 0.79, 95% CI 0.66-0.95, P = 0.012); this reduction was highest after the national lockdown (IRR 0.68, 95% CI 0.52-0.91, P = 0.009). The prevalence of residents in rural areas undergoing urgent pacemaker implant was lower in the case period (36%) than in both the intra-year (47%, P = 0.03) and inter-year control periods (51%, P = 0.002). Elective pacemaker implants also decreased in the case period, with the incidence rate here being 3.5/day vs. 6.4/day in the intra-year (-45%) and 6.9/day in the inter-year period (-49%). CONCLUSION: Despite severe clinical patterns, the COVID-19 outbreak has negatively affected the population presentation to Emergency Departments for bradyarrhythmias requiring urgent pacemaker implant in Northern Italy. This mainly occurred after the national lockdown and concerned patients living in rural areas.


Assuntos
Bradicardia/epidemiologia , Bradicardia/terapia , COVID-19/epidemiologia , Surtos de Doenças/estatística & dados numéricos , Procedimentos Cirúrgicos Eletivos/estatística & dados numéricos , Emergências/epidemiologia , Marca-Passo Artificial/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Incidência , Itália/epidemiologia , Masculino , Estudos Retrospectivos
7.
Minerva Cardiol Angiol ; 69(1): 15-24, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32657553

RESUMO

BACKGROUND: Cardiac contractility modulation (CCM) is a treatment option for patients suffering symptomatic chronic heart failure (CHF) with reduced left ventricular ejection fraction (LVEF) who are not eligible for cardiac resynchronization. Data on mid-term follow-up are limited to small observational studies. The aim of this study was to assess the impact of CCM on quality of life, symptoms, exercise tolerance and left ventricular function in patients with CHF and moderate-to-severe left ventricular systolic dysfunction. METHODS: Patients suffering CHF with LVEF <45% and NYHA class >II despite optimal medical therapy, underwent CCM implantation. Enrolled patients underwent baseline and 3, 6 and 12-months evaluation with ECG, echocardiogram, clinical assessment, 6-minute walking test and Minnesota Living with Heart Failure Questionnaire (MLWHFQ). RESULTS: Ten patients underwent CCM implantation. All patients were actively treated with the optimal pharmacological therapy as tolerated and had at least one hospitalization for worsening heart failure during the previous year. After a mean follow-up of 15 months, 9 patients were alive, while one patient died for worsening heart failure precipitated by pneumonia. Among the remaining 9 patients, LVEF improved non-significantly from 29.4±8% to 32.2±10% (P=0.092), 6-minute walking test distance improved from 179±73 m to 304±99 m (P<0.001), NYHA class reduced from 3.0±0.4 to 1.6±0.5 (P=0.003) and MLWHFQ score improved from 59.6±49 to 34.2±32 (P=0.037). Only 2 patients have been hospitalized during the 12 months. Overall, a net clinical benefit was detected in 6 out of 9 patients. CONCLUSIONS: CCM could be effective in improving quality of life, symptoms and exercise tolerance, and reduces hospitalizations in patients with symptomatic CHF on top of optimal medical and electrical therapy. A prospective registry has been designed to identify the subsets of patients gaining more benefit, and to assess the long-term effect of CCM on those clinical endpoints.


Assuntos
Qualidade de Vida , Função Ventricular Esquerda , Humanos , Projetos Piloto , Sistema de Registros , Volume Sistólico , Resultado do Tratamento
8.
Pacing Clin Electrophysiol ; 41(6): 597-602, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29635696

RESUMO

BACKGROUND: Simultaneous cathodic-anodal capture by a bipole of a cardiac resynchronization therapy (CRT) left-ventricular (LV) catheter may depolarize a larger LV area than conventional multipoint pacing. We evaluated the feasibility of cathodic-anodal LV stimulation. METHODS: In 30 patients undergoing CRT with a quadripolar LV lead, we evaluated the cathodic and anodal capture threshold for each LV pole and compared QRS on electrocardiogram (ECG) during single-point cathodic biventricular stimulation (S-BS), multipoint BS (M-BS), and cathodic-anodal BS (CA-BS). RESULTS: Anodal capture was obtained by three poles in 23/30 patients, by two poles in five, and was not feasible in two. The mean single-point anodal threshold was 3.93 V versus single-point cathodic threshold of 1.95 V. On comparing ECGs, M-BS and CA-BS produced similar QRS wavefront activation in 90% of patients. CONCLUSIONS: CA-BS is feasible and may be used in LV pacing to achieve a different wavefront of electrical activation. Further prospective studies are needed in order to verify the clinical impact of this kind of stimulation.


Assuntos
Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Idoso , Eletrocardiografia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Resultado do Tratamento
9.
Europace ; 20(5): 859-866, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28407148

RESUMO

Aims: Closed-loop stimulation (CLS) seemed promising in preventing the recurrence of vasovagal syncope (VVS) in patients with a cardioinhibitory response to head-up tilt test (HUTT) compared with conventional pacing. We hypothesized that the better results of this algorithm are due to its quick reaction in high-rate pacing delivered in the early phase of vasovagal reflex, which increase the cardiac output and the blood pressure preventing loss of consciousness. Methods and results: This prospective, randomized, single-blind, multicentre study was designed as an intra-patient comparison and enrolled 30 patients (age 62.2 ± 13.5 years, males 60.0%) with cardioinhibitory VVS, carrying a dual-chamber pacemaker incorporating CLS algorithm. Two HUTTs were performed one week apart: one during DDD-CLS 60-130/min pacing and the other during DDD 60/min pacing; patients were randomly and blindly assigned to two groups: in one the first HUTT was performed in DDD-CLS (n = 15), in the other in DDD (n = 15). Occurrence of syncope and haemodynamic variations induced by HUTT was recorded during the tests. Compared with DDD, DDD-CLS significantly reduced the occurrence of syncope induced by HUTT (30.0% vs. 76.7%; P < 0.001). In the patients who had syncope in both DDD and DDD-CLS mode, DDD-CLS significantly delayed the onset of syncope during HUTT (from 20.8 ± 3.9 to 24.8 ± 0.9 min; P = 0.032). The maximum fall in systolic blood pressure recorded during HUTT was significantly lower in DDD-CLS compared with DDD (43.2 ± 30.3 vs. 65.1 ± 25.8 mmHg; P = 0.004). Conclusion: In patients with cardioinhibitory VVS, CLS reduces the occurrence of syncope induced by HUTT, compared with DDD pacing. When CLS is not able to abort the vasovagal reflex, it seems to delay the onset of syncope.


Assuntos
Estimulação Cardíaca Artificial/métodos , Hemodinâmica , Prevenção Secundária/métodos , Síncope Vasovagal , Teste da Mesa Inclinada/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Recidiva , Índice de Gravidade de Doença , Método Simples-Cego , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/etiologia , Síncope Vasovagal/fisiopatologia , Tempo para o Tratamento
10.
Clin Res Cardiol ; 107(4): 329-337, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29181725

RESUMO

BACKGROUND: Diastolic dysfunction promotes atrial fibrillation (AF) inducing left atrial (LA) remodeling, with chamber dilation and fibrosis. Predominance of LA phasic conduit (LAC) function should reflect not only chamber alterations but also underlying left ventricular (LV) filling impairment. Thus, LAC was tested as possible predictor of early AF relapse after electrical cardioversion (EC). METHODS: 96 consecutive patients, who underwent EC for persistent non-valvular AF, were prospectively enrolled. Immediately after successful EC (3 h ± 15 min), an echocardiographic apical four-chamber view was acquired with transmitral velocities, annular tissue Doppler and simultaneous LV and LA three-dimensional full-volume datasets. Then, from LA-LV volumetric curves we computed LAC as: [(LV maximum - LV minimum) - (LA maximum - LA minimum) volume], expressed as % LV stroke volume. LA pump, immediately post-EC, was assumed and verified as being negligible. Sinus rhythm persistence at 1 month was checked with ECG-Holter monitoring. RESULTS: At 1 month 62 patients were in sinus rhythm and 34 in AF. AF patients presented pre-EC higher E/é values (p = 0.012), no major LA volume differences (p = NS), but a stiffer LV cavity (p = 0.012) for a comparable LV capacitance (p = 0.461). Conduit contributed more (p < 0.001) to LV stroke volume in AF subpopulation. Multiple regression revealed LAC as the most significant AF predictor (p = 0.013), even after correction for biometric characteristics and pharmacotherapy (p = 0.008). CONCLUSION: Our data suggest that LAC larger contribution to LV filling soon after EC reflects LA-LV stiffening, which skews atrioventricular interaction leading to AF perpetuation and makes conduit dominance a powerful predictor of early AF recurrence.


Assuntos
Fibrilação Atrial/terapia , Função do Átrio Esquerdo , Remodelamento Atrial , Cardioversão Elétrica/efeitos adversos , Função Ventricular Esquerda , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ecocardiografia Doppler , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Estudos Prospectivos , Recidiva , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...