Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 16(13)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37445153

RESUMO

Hydrogen can degrade the mechanical properties of steel components, which is commonly referred to as "hydrogen embrittlement" (HE). Quantifying the effect of HE on the structural integrity of components and structures remains challenging. The authors investigated an X70 pipeline steel through uncharged and hydrogen-charged (notched) tensile tests. This paper presents a combination of experimental results and numerical simulations using a micro-mechanics-inspired damage model. Four specimen geometries and three hydrogen concentrations (including uncharged) were targeted, which allowed for the construction of a fracture locus that depended on the stress triaxiality and hydrogen concentration. The multi-physical finite element model includes hydrogen diffusion and damage on the basis of the complete Gurson model. Hydrogen-Assisted degradation was implemented through an acceleration of the void nucleation process, as supported by experimental observations. The damage parameters were determined through inverse analysis, and the numerical results were in good agreement with the experimental data. The presented model couples micro-mechanical with macro-mechanical results and makes it possible to evaluate the damage evolution during hydrogen-charged mechanical tests. In particular, the well-known ductility loss due to hydrogen was captured well in the form of embrittlement indices for the different geometries and hydrogen concentrations. The limitations of the damage model regarding the stress state are discussed in this paper.

2.
Materials (Basel) ; 16(4)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36837331

RESUMO

This study aims to demonstrate the capability of the digital image correlation (DIC) technique for evaluating full-field residual stresses in wire and arc additive manufactured (WAAM) components. Investigations were carried out on WAAM steel parts (wall deposited on a substrate) with two different wall heights: 24 mm and 48 mm. Mild steel solid wire AWS ER70S-6 was used to print WAAM walls on substrates that were rigidly clamped to H-profiles. DIC was used to monitor the bending deformation of WAAM parts during unclamping from the H-profiles, and residual stresses were calculated from the strain field captured during unclamping. Residual stresses determined from the proposed DIC-based method were verified with an analytical model and validated by the results from established residual stress measurement techniques, i.e., the contour method and X-ray diffraction.

3.
Materials (Basel) ; 15(3)2022 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-35160908

RESUMO

This work presents the development of a J-integral estimation procedure for deep and shallow cracked bend specimens based upon plastic ηpl factors for a butt weld made in an S690 QL high strength low alloyed steel. Experimental procedures include the characterization of average material properties by tensile testing and evaluation of base and weld metal resistance to stable tearing by fracture testing of square SE(B) specimens containing a weld centerline notch. J-integral has been estimated from plastic work using a single specimen approach and the normalization data reduction technique. A comprehensive parametric finite element study has been conducted to calibrate plastic factor ηpl and geometry factor λ for various fixture and weld configurations, while a corresponding plastic factor γpl was computed on the basis of the former two. The modified ηpl and γpl factors were then incorporated in the J computation procedure given by the ASTM E1820 standard, for evaluation of the plastic component of J and its corresponding correction due to crack growth, respectively. Two kinds of J-R curves were computed on the basis of modified and standard ηpl and γpl factors, where the latter are given by ASTM E1820. A comparison of produced J-R curves for the base material revealed that variations in specimen fixtures can lead to ≈10% overestimation of computed fracture toughness JIc. Furthermore, a comparison of J-R curves for overmatched single-material idealized welds revealed that the application of standard ηpl and γpl factors can lead to the overestimation of computed fracture toughness JIc by more than 10%. Similar observations are made for undermatched single material idealized welds, where fracture toughness JIc is overestimated by ≈5%.

4.
J Exp Orthop ; 1(1): 7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26914752

RESUMO

BACKGROUND: Determining the mechanical behaviour of tendon and ligamentous tissue remains challenging, as it is anisotropic, non-linear and inhomogeneous in nature. METHODS: In this study, three-dimensional (3D) digital image correlation (DIC) was adopted to examine the strain distribution in the human Achilles tendon. Therefore, 6 fresh frozen human Achilles tendon specimens were mounted in a custom made rig for uni-axial loading. 3D DIC measurements of each loading position were obtained and compared to 2 linear variable differential transformers (LVDT's). RESULTS: 3D DIC was able to calculate tendon strain in every region of all obtained images. The scatter was found to be low in all specimens and comparable to that obtained in steel applications. The accuracy of the 3D DIC measurement was higher in the centre of the specimen where scatter values around 0.03% strain were obtained. The overall scatter remained below 0.3% in all specimens. The spatial resolution of 3D DIC on human tendon tissue was found to be 0.1 mm(2). The correlation coefficient between the 3D DIC measurements and the LVDT measurements showed an excellent linear agreement in all specimens (R(2) = 0.99). Apart from the longitudinal strain component, an important transverse strain component was revealed in all specimens. The strain distribution of both components was of a strongly inhomogeneous nature, both within the same specimen and amongst different specimens. CONCLUSION: DIC proved to be a very accurate and reproducible tool for 3D strain analysis in human tendon tissue.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA