Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Card Fail ; 21(3): 226-32, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25528199

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) can improve survival in left ventricular assist device (LVAD) recipients. However, the impact of cardiac resynchronization therapy (CRT-D) on outcomes in continuous-flow left ventricular assist device (CF-LVAD) patients is not known. We sought to determine if CRT-D improved clinical outcomes in CF-LVAD patients compared with ICDs alone. METHODS AND RESULTS: Sixty-one consecutive CF-LVAD patients with an ICD or CRT-D were evaluated. Impacts of CRT-D on mortality, all-cause hospitalization, and incidence of atrial (AA) and ventricular (VA) arrhythmias after LVAD implantation was compared with patients with ICD alone. Of the 61 LVAD patients, 31 (age 59.8 ± 16 years, 84% male) had CRT-D and 30 (age 57.2 ± 13 years, 74% male) had ICD. Before LVAD implantation, no significant differences were noted between the groups in demographic and clinical characteristics, LVAD indications, and incidence of AA and VA. Over 682 ± 45 days of LVAD support, 8 patients (25.8%) died in the CRT-D arm versus 5 (16.7%) in the ICD arm (P = .35). No differences were noted between the CRT-D and ICD groups in all-cause (96.8 vs 93.3%; P = .63) and HF (19.4 vs 26.7%; P = .78) hospitalizations, left ventricular (LV) end-diastolic diameter (6.4 ± 1.5 vs 6.2 ± 1.1 cm, P = .47), and incidence of AA (35.4% vs 33.3%; P = .80), VA (29% vs 26.6%; P = .86), and ICD shocks (22.6% vs 16.7%; P = .93). Beta-blocker and antiarrhythmic drug use after LVAD implantation was similar in both groups. CONCLUSIONS: In patients with refractory HF who received CF-LVADs, CRT-D, compared with ICD, did not significantly improve mortality, all-cause hospitalization, LV dimensions, and incidence of AA and VA.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Desfibriladores Implantáveis , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Coração Auxiliar , Hospitalização , Adulto , Idoso , Terapia de Ressincronização Cardíaca/tendências , Desfibriladores Implantáveis/tendências , Feminino , Seguimentos , Transplante de Coração/mortalidade , Transplante de Coração/tendências , Coração Auxiliar/tendências , Hospitalização/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade/tendências , Resultado do Tratamento
2.
Congest Heart Fail ; 19(4): 165-71, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23910701

RESUMO

Persistent atrial flutter (AFL) in left ventricular assist device (LVAD) recipients can result in loss of AV synchrony, impaired ventricular filling and right heart failure (RHF). The authors report the largest series of HeartMate II (HMII) patients who developed AFL with decompensated RHF, which successfully resolved with AFL ablation. Eight patients with HMII LVAD (mean age, 57±12 years) had medically refractory AFL, with 7 developing de novo AFL after LVAD implant (onset range, 2 days-22 months post-implant). Three patients developed recurrent syncope, 2 had inappropriate implantable cardioverter-defibrillator shocks, and 6 had new or escalating need for inotropes. All had features of decompensated RHF. Seven patients underwent electrophysiology testing where mapping confirmed typical counterclockwise AFL (mean AFL cycle length, 252±49 ms) and radiofrequency ablation of cavotricuspid isthmus restored sinus rhythm in all patients. Complete resolution of symptoms and signs of RHF with improved quality of life were noted in all. No procedural complications were noted. During a mean follow-up of 9±5 months, all patients remained free of atrial flutter. Catheter ablation of AFL in LVAD patients is safe and highly effective, resulting in immediate and significant improvement in symptoms of RHF, and should be considered first-line therapy for AFL in these patients.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Insuficiência Cardíaca/terapia , Coração Auxiliar , Adulto , Idoso , Flutter Atrial/complicações , Flutter Atrial/fisiopatologia , Eletrocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento
3.
J Heart Lung Transplant ; 26(4): 414-6, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17403487

RESUMO

Atrial flutter is common after orthotopic heart transplantation. We present the case of a patient who presented with atrial flutter on 12-lead electrocardiogram. On invasive electrophysiologic study, the donor heart was found to be in sinus rhythm and the recipient atrium was in flutter, which was dissociated from the donor.


Assuntos
Flutter Atrial/diagnóstico , Flutter Atrial/etiologia , Eletrodiagnóstico , Transplante de Coração , Complicações Pós-Operatórias/diagnóstico , Doadores de Tecidos , Diagnóstico Diferencial , Eletrocardiografia , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...