Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
AJNR Am J Neuroradiol ; 33(1): 69-76, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22095961

RESUMO

BACKGROUND AND PURPOSE: Quantifying MVA rather than MVD provides better correlation with survival in HGG. This is attributed to a specific "glomeruloid" vascular pattern, which is better characterized by vessel area than number. Despite its prognostic value, MVA quantification is laborious and clinically impractical. The DSC-MR imaging measure of rCBV offers the advantages of speed and convenience to overcome these limitations; however, clinical use of this technique depends on establishing accurate correlations between rCBV, MVA, and MVD, particularly in the setting of heterogeneous vascular size inherent to human HGG. MATERIALS AND METHODS: We obtained preoperative 3T DSC-MR imaging in patients with HGG before stereotactic surgery. We histologically quantified MVA, MVD, and vascular size heterogeneity from CD34-stained 10-µm sections of stereotactic biopsies, and we coregistered biopsy locations with localized rCBV measurements. We statistically correlated rCBV, MVA, and MVD under conditions of high and low vascular-size heterogeneity and among tumor grades. We correlated all parameters with OS by using Cox regression. RESULTS: We analyzed 38 biopsies from 24 subjects. rCBV correlated strongly with MVA (r = 0.83, P < .0001) but weakly with MVD (r = 0.32, P = .05), due to microvessel size heterogeneity. Among samples with more homogeneous vessel size, rCBV correlation with MVD improved (r = 0.56, P = .01). OS correlated with both rCBV (P = .02) and MVA (P = .01) but not with MVD (P = .17). CONCLUSIONS: rCBV provides a reliable estimation of tumor MVA as a biomarker of glioma outcome. rCBV poorly estimates MVD in the presence of vessel size heterogeneity inherent to human HGG.


Assuntos
Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/cirurgia , Glioma/patologia , Glioma/cirurgia , Angiografia por Ressonância Magnética/métodos , Microvasos/patologia , Recidiva Local de Neoplasia/patologia , Adulto , Determinação do Volume Sanguíneo , Neoplasias Encefálicas/irrigação sanguínea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/irrigação sanguínea , Recidiva Local de Neoplasia/prevenção & controle , Neovascularização Patológica/patologia , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Técnicas Estereotáxicas , Resultado do Tratamento
2.
AJNR Am J Neuroradiol ; 33(4): 695-700, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22173748

RESUMO

BACKGROUND AND PURPOSE: DTI is increasingly being used as a measure to study tissue damage in several neurologic diseases. Our aim was to investigate the comparability of DTI measures between different MR imaging magnets and platforms. MATERIALS AND METHODS: Two healthy volunteers underwent DTI on five 3T MR imaging scanners (3 Trios and 2 Signas) by using a matched 33 noncollinear diffusion-direction pulse sequence. Within each subject, a total of 16 white matter (corpus callosum, periventricular, and deep white matter) and gray matter (cortical and deep gray) ROIs were drawn on a single image set and then were coregistered to the other images. Mean FA, ADC, and longitudinal and transverse diffusivities were calculated within each ROI. Concordance correlations were derived by comparing ROI DTI values among each of the 5 magnets. RESULTS: Mean concordance for FA was 0.96; for both longitudinal and transverse diffusivities, it was 0.93; and for ADC, it was 0.88. Mean scan-rescan concordance was 0.96-0.97 for all DTI measures. Concordance correlations within platforms were, in general, better than those between platforms for all DTI measures (mean concordance of 0.96). CONCLUSIONS: We found that a 3T magnet and high-angular-resolution pulse sequence yielded comparable DTI measurements across different MR imaging magnets and platforms. Our results indicate that FA is the most comparable measure across magnets, followed by individual diffusivities. The comparability of DTI measures between different magnets supports the feasibility of multicentered clinical trials by using DTI as an outcome measure.


Assuntos
Encéfalo/anatomia & histologia , Imagem de Difusão por Ressonância Magnética/instrumentação , Aumento da Imagem/instrumentação , Adulto , Anisotropia , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Masculino , Ohio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
AJNR Am J Neuroradiol ; 31(1): 40-8, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19749223

RESUMO

BACKGROUND AND PURPOSE: Relative cerebral blood volume (rCBV) accuracy can vary substantially depending on the dynamic susceptibility-weighted contrast-enhanced (DSC) acquisition and postprocessing methods, due to blood-brain barrier disruption and resulting T1-weighted leakage and T2- and/or T2*-weighted imaging (T2/T2*WI) residual effects. We set out to determine optimal DSC conditions that address these errors and maximize rCBV accuracy in differentiating posttreatment radiation effect (PTRE) and tumor. MATERIALS AND METHODS: We recruited patients with previously treated high-grade gliomas undergoing image-guided re-resection of recurrent contrast-enhancing MR imaging lesions. Thirty-six surgical tissue samples were collected from 11 subjects. Preoperative 3T DSC used 6 sequential evenly timed acquisitions, each by using a 0.05-mmol/kg gadodiamide bolus. Preload dosing (PLD) and baseline subtraction (BLS) techniques corrected T1-weighted leakage and T2/T2*WI residual effects, respectively. PLD amount and incubation time increased with each sequential acquisition. Corresponding tissue specimen stereotactic locations were coregistered to DSC to measure localized rCBV under varying PLD amounts, incubation times, and the presence of BLS. rCBV thresholds were determined to maximize test accuracy (average of sensitivity and specificity) in distinguishing tumor (n = 21) and PTRE (n = 15) samples under the varying conditions. Receiver operator characteristic (ROC) areas under the curve (AUCs) were statistically compared. RESULTS: The protocol that combined PLD (0.1-mmol/kg amount, 6-minute incubation time) and BLS correction methods maximized test AUC (0.99) and accuracy (95.2%) compared with uncorrected rCBV AUC (0.85) and accuracy (81.0%) measured without PLD and BLS (P = .01). CONCLUSIONS: Combining PLD and BLS correction methods for T1-weighted and T2/T2*WI errors, respectively, enables highly accurate differentiation of PTRE and tumor growth.


Assuntos
Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/cirurgia , Glioma/diagnóstico , Glioma/cirurgia , Angiografia por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/normas , Adulto , Neoplasias Encefálicas/patologia , Feminino , Glioma/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
4.
AJNR Am J Neuroradiol ; 30(3): 552-8, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19056837

RESUMO

BACKGROUND AND PURPOSE: Differentiating tumor growth from posttreatment radiation effect (PTRE) remains a common problem in neuro-oncology practice. To our knowledge, useful threshold relative cerebral blood volume (rCBV) values that accurately distinguish the 2 entities do not exist. Our prospective study uses image-guided neuronavigation during surgical resection of MR imaging lesions to correlate directly specimen histopathology with localized dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging (DSC) measurements and to establish accurate rCBV threshold values, which differentiate PTRE from tumor recurrence. MATERIALS AND METHODS: Preoperative 3T gradient-echo DSC and contrast-enhanced stereotactic T1-weighted images were obtained in patients with high-grade glioma (HGG) previously treated with multimodality therapy. Intraoperative neuronavigation documented the stereotactic location of multiple tissue specimens taken randomly from the periphery of enhancing MR imaging lesions. Coregistration of DSC and stereotactic images enabled calculation of localized rCBV within the previously recorded specimen locations. All tissue specimens were histopathologically categorized as tumor or PTRE and were correlated with corresponding rCBV values. All rCBV values were T1-weighted leakage-corrected with preload contrast-bolus administration and T2/T2*-weighted leakage-corrected with baseline subtraction integration. RESULTS: Forty tissue specimens were collected from 13 subjects. The PTRE group (n = 16) rCBV values ranged from 0.21 to 0.71, tumor (n = 24) values ranged from 0.55 to 4.64, and 8.3% of tumor rCBV values fell within the PTRE group range. A threshold value of 0.71 optimized differentiation of the histopathologic groups with a sensitivity of 91.7% and a specificity of 100%. CONCLUSIONS: rCBV measurements obtained by using DSC and the protocol we have described can differentiate HGG recurrence from PTRE with a high degree of accuracy.


Assuntos
Neoplasias Encefálicas/patologia , Circulação Cerebrovascular , Glioma/patologia , Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/patologia , Radioterapia/efeitos adversos , Biópsia , Volume Sanguíneo , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Terapia Combinada , Craniotomia , Diagnóstico Diferencial , Glioma/radioterapia , Glioma/cirurgia , Humanos , Imageamento por Ressonância Magnética/normas , Neuronavegação , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Magn Reson Med ; 42(1): 69-81, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10398952

RESUMO

A method to tailor the view order to the reconstruction cycle is introduced for real-time MRI. It is well known that view sharing and oversampling central k-space views can improve the temporal resolution of gradient-echo pulse sequences. By ordering phase-encodes to synchronize k-space acquisition with the reconstruction cycle, apparent temporal resolution can match the frame rate with as few as one-fourth of the phase-encodes sampled per reconstruction. Spatial resolution is maintained by periodically updating high spatial frequencies. In addition to apparent temporal resolution, three other criteria for real-time imaging are identified and evaluated: display latency, dispersion, and frame-to-frame consistency. Latency is minimized by ordering views in a reverse-centric manner within each reconstruction interval, sampling high-energy views immediately prior to beginning reconstruction. Dispersion is kept low and consistent by synchronizing acquisition and reconstruction, thus avoiding poorly timed reconstruction instances. Real-time implementation demonstrates pulsatile time-of-flight blood signal enhancement in humans.


Assuntos
Fluoroscopia/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Algoritmos , Velocidade do Fluxo Sanguíneo/fisiologia , Simulação por Computador , Imagem Ecoplanar/instrumentação , Desenho de Equipamento , Análise de Fourier , Humanos , Aumento da Imagem/instrumentação , Imagens de Fantasmas , Fluxo Pulsátil/fisiologia , Sensibilidade e Especificidade
6.
Magn Reson Med ; 41(4): 846-9, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10332863

RESUMO

Magnetic resonance imaging allows significant freedom in selecting the orientation and position of a tomographic section. However, it can nonetheless be challenging to determine quickly and efficiently the correct parameters required to image a targeted anatomic structure that may lie at an oblique angle in the imaging volume. We describe a three-point tool in which a) the user interactively selects three points from an anatomic structure of interest during live MR fluoroscopy; b) adjustments to pulse sequence are calculated to image the tomographic section defined by the three points; and c) the section is then immediately imaged fluoroscopically. The tool allows quick localization of, for example, longitudinal images of specific arterial structures.


Assuntos
Artérias/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Algoritmos , Aorta Torácica/anatomia & histologia , Artérias Carótidas/anatomia & histologia , Fluoroscopia/métodos , Humanos , Rotação , Tomografia
7.
Magn Reson Med ; 40(1): 24-35, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9660549

RESUMO

Arterial-phase three-dimensional (3D) contrast-enhanced MR angiograms of the carotid and vertebral arteries from their origins through the carotid bifurcations were obtained in 20 patients using acquisition times over 30 sec by using an MR fluoroscopy-triggered pulse sequence with elliptical centric view order. The typical pixel size was 0.8 mm (x) x 1.6 mm (y) x 1.5 mm (z), and 32-48 coronal slices were acquired. The fluoroscopic monitoring of bolus arrival was effective in 18 of the 20 cases; two failures were attributed directly to a poor choice of RF coil. To exploit peak arterial-to-venous contrast, the central 3D views were acquired first in the most compact time period possible for the given TR. For the 18 successfully triggered cases, arterial-phase 3D images were obtained with excellent venous suppression as demonstrated by an average internal jugular vein to common carotid signal enhancement ratio of only 0.05 +/- 0.04.


Assuntos
Artérias Carótidas/patologia , Fluoroscopia/métodos , Angiografia por Ressonância Magnética/métodos , Intensificação de Imagem Radiográfica/métodos , Doenças Vasculares/diagnóstico , Artéria Vertebral/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artérias Carótidas/diagnóstico por imagem , Meios de Contraste , Feminino , Fluoroscopia/instrumentação , Gadolínio , Compostos Heterocíclicos , Humanos , Angiografia por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Sensibilidade e Especificidade , Artéria Vertebral/diagnóstico por imagem
8.
Magn Reson Med ; 38(6): 1003-11, 1997 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9402202

RESUMO

Multiple element surface coils are often used in clinical MRI to increase the image signal-to-noise ratio (S/N). Use of multicoils typically requires increased net sampling bandwidth and data processing for each coil element. A phase-alignment technique is described which combines the signals from all coil elements before image reconstruction, greatly relaxing the technical requirements of the standard multicoil methods. Hardware and software implementations allow reduction of the reconstruction requirement to that of a single coil. The hardware implementation additionally allows a significant reduction in the net sampling bandwidth. The method is applicable to high speed MRI techniques, as demonstrated in phantoms and volunteers.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas
9.
Radiology ; 205(1): 137-46, 1997 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9314975

RESUMO

PURPOSE: To determine the reliability of obtaining arterial-phase, contrast-material-enhanced three-dimensional (3D) magnetic resonance (MR) angiograms of the renal arteries by using a technique that combines two-dimensional real-time MR fluoroscopy and a 3D MR angiographic acquisition with elliptical centric view order. MATERIALS AND METHODS: Twenty-five consecutive patients suspected of having renal artery disease were evaluated with the fluoroscopically triggered technique by using a mean dose of 0.18 mmol/kg gadoteridol. Left renal vein suppression, inferior vena cava suppression, motion artifact, and image quality for depiction of the renal arteries were each evaluated on a five-point scale (1 = best). The findings were compared with those of another 25 consecutive patients who underwent conventional gadolinium-enhanced 3D MR angiography. RESULTS: The fluoroscopically triggered technique produced 4.6 times less left renal vein enhancement than did the conventional method (P < .01). With the fluoroscopically triggered technique, visualization of the renal arteries was adequate for diagnosis in 24 patients (96%) and the overall result (score of 1-3 for all criteria) was of good quality in 22 patients (88%). CONCLUSION: With this fluoroscopically triggered MR angiographic technique, high-quality, arterial phase, relatively motion immune angiograms can be routinely obtained.


Assuntos
Meios de Contraste/administração & dosagem , Fluoroscopia , Compostos Heterocíclicos , Angiografia por Ressonância Magnética/métodos , Compostos Organometálicos , Artéria Renal/patologia , Adolescente , Adulto , Idoso , Aorta Abdominal/patologia , Feminino , Gadolínio/administração & dosagem , Compostos Heterocíclicos/administração & dosagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Obstrução da Artéria Renal/diagnóstico , Veias Renais/patologia , Veia Cava Inferior/patologia
10.
Magn Reson Med ; 36(4): 588-95, 1996 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8892212

RESUMO

A technique is described for high speed interactive imaging of the heart with either white or black blood contrast. Thirty-two views of a segmented, magnetization-prepared gradient echo sequence are acquired during diastole. Using three-quarter partial Fourier sampling, data for a complete 128 x 128 image are acquired in three cardiac cycles. High speed reconstruction provides an image update of each cardiac cycle 159 ms after measurement. An independent graphical user interface facilitates interactive control of section localization and contrast by permitting pulse sequence parameter modification during scanning. The efficiency and image quality of the cardiac MR fluoroscopy technique were evaluated in 11 subjects. Compared with the conventional graphic prescription method, the cardiac fluoroscopy technique provides an approximate eightfold reduction in the time required to obtain subject-specific double oblique sections. Image quality for these scout acquisitions performed during free breathing was sufficient to identify small cardiac structures.


Assuntos
Coração/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Angiografia Coronária , Vasos Coronários/anatomia & histologia , Eletrocardiografia , Fluoroscopia , Humanos , Músculos Papilares/anatomia & histologia , Músculos Papilares/diagnóstico por imagem
11.
Magn Reson Med ; 34(1): 11-6, 1995 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7674888

RESUMO

To reduce respiratory blur and ghosts in 3D coronary imaging, a data acquisition scheme using consistent multiple breath-holds was implemented. A navigator echo was acquired and processed in real time to dynamically measure diaphragm position. This information was provided as a visual prompt to the patient to maintain consistency in breath-hold levels such that the variation range of diastolic heart position was less than 2 mm. Preliminary results indicate that this multiple breath-hold acquisition scheme, compared with acquisition under respiration, can significantly reduce blur and ghost artifacts in 3D coronary imaging.


Assuntos
Artefatos , Vasos Coronários/anatomia & histologia , Processamento de Imagem Assistida por Computador , Angiografia por Ressonância Magnética/métodos , Monitorização Fisiológica/métodos , Respiração , Adulto , Eletrocardiografia , Retroalimentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
12.
Magn Reson Med ; 34(1): 114-9, 1995 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7674889

RESUMO

In applications where precise image section positioning is vital, the interactive section rotation and offset capabilities of interactive MRI should be valuable. However, due to the independent nature of these two adjustments, the desired structure may often not be visible in the image after a rotation. Valuable time is wasted during relocation. An algorithm is presented that automatically alters the section offset after a rotation to provide continuous viewing of a marked structure, greatly improving section orientation efficiency. The technique is illustrated in the determination of double oblique angulation for through-plane imaging of the portal vein. This algorithm is expected to prove useful in applications of interactive MRI requiring precise positioning.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Humanos
13.
Magn Reson Med ; 30(4): 507-11, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8255201

RESUMO

A technique is described that provides improved reproducibility of breath-holding for MR image acquisition by monitoring the superior-inferior (S/I) position of the diaphragm. The method incorporates detection of the level of inspiration using an MR signal, rapid display to the patient of diaphragm position to enable breath-hold adjustment, and triggering of image data acquisition once appropriate position is attained. The response time of the system is short, approximately 10 ms. Studies in six volunteers using this method demonstrate a considerable decrease in the S/I range of diaphragm position over 10 consecutive periods of suspended respiration. The mean range is 1.3 mm with the system, while it is 8.3 mm without using it. It is expected that this method will be of assistance in many abdominal and cardiothoracic studies that use breath-hold techniques.


Assuntos
Imageamento por Ressonância Magnética/métodos , Monitorização Fisiológica/métodos , Respiração , Retroalimentação , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...