Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 34(1): 135-141, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36300705

RESUMO

INTRODUCTION: BNP elevation in patients with AF is observed in the absence of heart failure; however, prior mechanistic studies have not included direct left atrial pressure measurements. This study sought to understand how emptying function of the left atrial appendage (LAA) and LAA dimension contributes to brain-natriuretic peptide elevations (BNP) in atrial fibrillation (AF) accounting for left atrial pressure (LAP). METHODS: 132 patients referredfor left atrial appendage occlusion (LAAO) were prospectively enrolled in this study. BNP levels and LAP were measured just before LAAO. Statistical analysis considered BNP, rhythm at time of procedure, LAP, LAA morphology, LAA size (ostial diameter, depth, volume), LAA emptying velocity, CHADS2-VASc score, body mass index (BMI), left ventricular ejection fraction (LVEF), estimated glomerular filtration rate (eGFR), and obstructive sleep apnea (OSA) diagnosis as covariates. RESULTS: Bivariate statistical analysis demonstrated positive associations with age, LAA ostial diameter, depth, and volume, LAP, AF status at time of measurement, OSA, and CHADS2-VASc score. BNP was negatively associated with LVEF, eGFR, LAA emptying velocity and BMI. With multivariate logistic regression including LAP as covariate, significant relationships between BNP and AF/AFL(OR 1.99 [1.03, 3.85]), LAP (OR 1.13 [1.06, 1.20]), LAA diameter (OR 1.14 [1.03, 1.27]), LAA depth (OR 1.14 [1.07, 1.22]), and LAA emptying velocity (OR 0.97 [0.96,0.99]) were observed; however, no significant associations were seen with LAA morphology or CHADS2-VASc score. CONCLUSIONS: BNP elevations in AF are associated with LAA size and function, but not CHADS2-VASc score or appendage morphology after accounting for changes in LAP.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Peptídeo Natriurético Encefálico , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/patologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/metabolismo , Ecocardiografia Transesofagiana , Peptídeo Natriurético Encefálico/sangue , Peptídeo Natriurético Encefálico/química , Apneia Obstrutiva do Sono/diagnóstico , Volume Sistólico , Função Ventricular Esquerda
2.
Semin Cardiothorac Vasc Anesth ; 24(4): 364-368, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32746732

RESUMO

Noonan syndrome is a relatively common genetic disorder and the second most common cause of congenital heart disease after trisomy 21. The spectrum of cardiac anomalies in Noonan syndrome typically involves pulmonary valve stenosis occasionally in conjunction with hypertrophic cardiomyopathy. Mitral valve involvement is a rare finding in Noonan syndrome and is most commonly associated with either mitral valve prolapse or abnormal valvular insertion causing left ventricular outflow tract obstruction. Patients with Noonan syndrome typically have preserved fertility and, given the success of cardiac surgery and medical management of heart failure in this population, are beginning to present more commonly as parturients in adulthood. Maternal physiologic changes during pregnancy introduce an added complexity to hemodynamic management and anesthetic considerations during labor and delivery. In this article, we present a case of a patient with Noonan syndrome with severe mitral stenosis, pulmonary valve insufficiency, and severe restrictive and obstructive pulmonary disease who presented preterm for delivery due to increased dyspnea at rest. Here we review the pathophysiology behind Noonan syndrome and peripartum management strategies in a patient with severe combined cardiac and pulmonary disease.


Assuntos
Cardiomiopatia Hipertrófica/complicações , Pneumopatias Obstrutivas/complicações , Estenose da Valva Mitral/complicações , Síndrome de Noonan/complicações , Síndrome de Noonan/fisiopatologia , Complicações na Gravidez/fisiopatologia , Insuficiência da Valva Pulmonar/complicações , Adulto , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/fisiopatologia , Cesárea , Dispneia/complicações , Dispneia/fisiopatologia , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Pneumopatias Obstrutivas/diagnóstico por imagem , Pneumopatias Obstrutivas/fisiopatologia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/fisiopatologia , Gravidez , Nascimento Prematuro , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Ultrassonografia/métodos
4.
Heart Rhythm ; 16(1): 12-17, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30012348

RESUMO

BACKGROUND: Incomplete surgical left atrial appendage occlusion (S-LAAO) with a narrow neck has been shown to predict an increased rate of embolic stroke. Patients with a previously attempted S-LAAO were systematically excluded from all clinical trials of LAA closure devices. OBJECTIVE: The purpose of this study was to evaluate the feasibility of Watchman LAA device closure for patients referred with chronically incomplete S-LAAO. METHODS: A prospective single-arm feasibility cohort evaluated only subjects undergoing Watchman LAA closure following incomplete S-LAAO. Patients referred and implanted were followed in the Vanderbilt LAA Registry. Preprocedure computed tomographic angiography and transesophageal echocardiography (TEE) were performed to evaluate suitability for closure, with 45-day follow-up TEE postimplant. RESULTS: All attempted LAA closures after incomplete S-LAAO were successful (n = 6). Mean age was 76.3 ± 7 years. Mean CHADS2Vasc score was 3.8 ± 0.8, and HAS-BLED score was 3.5 ± 0.5. At 45-day follow up, all subjects had complete device seal with no thrombus on device and had transitioned to clopidogrel plus aspirin. Three subjects had narrow ostial necks with a maximum diameter ≤9 mm. In all cases, the 4.7-mm Watchman access sheath was able to cross the ostial stricture. Mean occluder size implanted was 28 ± 4 mm. Mean LAA dimension by TEE in the 45° and 135° views for depth was 31 mm and ostial diameter was 11 × 16 mm, below the minimum Watchman indication for use of 17 mm. No major intraoperative complications occurred. CONCLUSION: Watchman LAA closure seems to be feasible in patients with chronically incomplete S-LAAO, including subjects with a narrow neck ≤9 mm in width.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Sistema de Registros , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Cateterismo Cardíaco/métodos , Angiografia por Tomografia Computadorizada , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Ligadura/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Falha de Tratamento
6.
Transfusion ; 55(11): 2752-8, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26202213

RESUMO

BACKGROUND: The wastage of red blood cell (RBC) units within the operative setting results in significant direct costs to health care organizations. Previous education-based efforts to reduce wastage were unsuccessful at our institution. We hypothesized that a quality and process improvement approach would result in sustained reductions in intraoperative RBC wastage in a large academic medical center. STUDY DESIGN AND METHODS: Utilizing a failure mode and effects analysis supplemented with time and temperature data, key drivers of perioperative RBC wastage were identified and targeted for process improvement. RESULTS: Multiple contributing factors, including improper storage and transport and lack of accurate, locally relevant RBC wastage event data were identified as significant contributors to ongoing intraoperative RBC unit wastage. Testing and implementation of improvements to the process of transport and storage of RBC units occurred in liver transplant and adult cardiac surgical areas due to their history of disproportionately high RBC wastage rates. Process interventions targeting local drivers of RBC wastage resulted in a significant reduction in RBC wastage (p < 0.0001; adjusted odds ratio, 0.24; 95% confidence interval, 0.15-0.39), despite an increase in operative case volume over the period of the study. Studied process interventions were then introduced incrementally in the remainder of the perioperative areas. CONCLUSIONS: These results show that a multidisciplinary team focused on the process of blood product ordering, transport, and storage was able to significantly reduce operative RBC wastage and its associated costs using quality and process improvement methods.


Assuntos
Eritrócitos , Centros Médicos Acadêmicos/estatística & dados numéricos , Preservação de Sangue/efeitos adversos , Transfusão de Eritrócitos/estatística & dados numéricos , Humanos , Período Perioperatório , Software
8.
J Cardiothorac Vasc Anesth ; 24(4): 568-73, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20346704

RESUMO

OBJECTIVE: In this study, the therapeutic use of pacing pulmonary artery catheters in association with minimally invasive cardiac surgery was evaluated. DESIGN: A retrospective study. SETTINGS: A single institutional university hospital. PARTICIPANTS: Two hundred twenty-four consecutive patients undergoing minimally invasive cardiac surgery through a small (5-cm) right anterolateral thoracotomy using fibrillatory arrest without aortic cross-clamping. MEASUREMENTS AND MAIN RESULTS: Two hundred eighteen patients underwent mitral valve surgery (97%) alone or in combination with other procedures. Six patients underwent other cardiac operations. In all patients, the pacing pulmonary artery catheter was used intraoperatively to induce ventricular fibrillation during the cooling period, and in the postoperative period it also was used in 37 (17%) patients who needed to be paced, mainly for bradyarrhythmias (51%). There were no complications related to the insertion of the catheters. Six (3%) patients experienced a loss of pacing capture, and 2 (1%) experienced another complication requiring the surgical removal of the catheter. Seven (3%) patients needed postoperative implantation of a permanent pacemaker. CONCLUSIONS: In combination with minimally invasive cardiac surgery, pacing pulmonary artery catheters were therapeutically useful to induce ventricular fibrillatory arrest intraoperatively and for obtaining pacing capability in the postoperative period. Their use was associated with a low number of complications.


Assuntos
Estimulação Cardíaca Artificial/tendências , Procedimentos Cirúrgicos Cardíacos/tendências , Cateterismo de Swan-Ganz/tendências , Procedimentos Cirúrgicos Minimamente Invasivos/tendências , Idoso , Estimulação Cardíaca Artificial/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Cateterismo de Swan-Ganz/métodos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Fatores de Tempo
10.
J Am Coll Cardiol ; 53(3): 232-41, 2009 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-19147039

RESUMO

OBJECTIVES: This study sought to report our experience with a routine completion angiogram after coronary artery bypass surgery (CABG) and simultaneous (1-stop) percutaneous coronary intervention (PCI) at the time of CABG performed in the hybrid catheterization laboratory/operating room. BACKGROUND: The value of a routine completion angiogram after CABG and 1-stop hybrid CABG/PCI remains unresolved. METHODS: Between April 2005 and July 2007, 366 consecutive patients underwent CABG surgery, with (n = 112) or without (n = 254) concomitant 1-stop PCI (hybrid), all with completion angiography before chest closure. Among the 112 1-stop hybrid CABG/PCI patients, 67 (60%) underwent a planned hybrid procedure based on pre-operative assessment, whereas 45 (40%) underwent open-chest PCI (unplanned hybrid) based on intraoperative findings. RESULTS: Among the 796 CABG grafts (345 left internal mammary artery, 12 right internal mammary artery/radial, and 439 veins), 97 (12%) angiographic defects were identified. Defects were repaired with either a minor adjustment of the graft (n = 22, 2.8%), with intraoperative open-chest PCI (unplanned hybrid, n = 48, 6%) or with traditional surgical revision (n = 27, 3.4%). Hybrid patients had clinical outcomes similar to standard CABG patients. CONCLUSIONS: Routine completion angiography detected 12% of grafts with important angiographic defects. One-stop hybrid coronary revascularization is reasonable, safe, and feasible. Combining the tools of the catheterization laboratory and operating room greatly enhances the options available to the surgeon and cardiologist for patients with complex coronary artery disease.


Assuntos
Angioplastia Coronária com Balão/métodos , Angiografia Coronária/métodos , Ponte de Artéria Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/cirurgia , Salas Cirúrgicas , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Cateterismo Cardíaco/métodos , Estudos de Coortes , Terapia Combinada , Ponte de Artéria Coronária/efeitos adversos , Doença das Coronárias/terapia , Feminino , Seguimentos , Humanos , Cuidados Intraoperatórios/métodos , Masculino , Pessoa de Meia-Idade , Probabilidade , Radiografia Intervencionista , Estudos Retrospectivos , Medição de Risco , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Stents , Resultado do Tratamento , Grau de Desobstrução Vascular
11.
J Extra Corpor Technol ; 39(3): 188-91, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17972454

RESUMO

Developing new strategies to improve patient safety and risk reduction is fundamental to hospital and patient success. Currently, there is a tendency in hospital safety management to focus solely on human error rather than organizational and educational causes that contribute to medical accidents. Although health care providers are the primary safety systems in medical facilities, there must be a more global, perhaps automated, approach using modern technology to prevent or reduce medical mishaps. Herein, we present an oxygenation failure with root cause analysis that prompted a new oxygenation safety algorithm and multi-service training initiative.


Assuntos
Algoritmos , Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/educação , Análise de Falha de Equipamento/métodos , Segurança de Equipamentos/métodos , Isquemia/etiologia , Oxigenadores/efeitos adversos , Falha de Equipamento , Feminino , Humanos , Isquemia/prevenção & controle , Pessoa de Meia-Idade , Nebulizadores e Vaporizadores , Ensino , Tennessee
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...