1.
Orthop J Sports Med ; 9(12): 23259671211046916, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34938819

RESUMO

BACKGROUND: Dynamic 3-dimensional (3D) simulation of hip impingement enables better understanding of complex hip deformities in young adult patients with femoroacetabular impingement (FAI). Deep learning algorithms may improve magnetic resonance imaging (MRI) segmentation. PURPOSE: (1) To evaluate the accuracy of 3D models created using convolutional neural networks (CNNs) for fully automatic MRI bone segmentation of the hip joint, (2) to correlate hip range of motion (ROM) between manual and automatic segmentation, and (3) to compare location of hip impingement in 3D models created using automatic bone segmentation in patients with FAI. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 3. METHODS: The authors retrospectively reviewed 31 hip MRI scans from 26 symptomatic patients (mean age, 27 years) with hip pain due to FAI. All patients had matched computed tomography (CT) and MRI scans of the pelvis and the knee. CT- and MRI-based osseous 3D models of the hip joint of the same patients were compared (MRI: T1 volumetric interpolated breath-hold examination high-resolution sequence; 0.8 mm3 isovoxel). CNNs were used to develop fully automatic bone segmentation of the hip joint, and the 3D models created using this method were compared with manual segmentation of CT- and MRI-based 3D models. Impingement-free ROM and location of hip impingement were calculated using previously validated collision detection software. RESULTS: The difference between the CT- and MRI-based 3D models was <1 mm, and the difference between fully automatic and manual segmentation of MRI-based 3D models was <1 mm. The correlation of automatic and manual MRI-based 3D models was excellent and significant for impingement-free ROM (r = 0.995; P < .001), flexion (r = 0.953; P < .001), and internal rotation at 90° of flexion (r = 0.982; P < .001). The correlation for impingement-free flexion between automatic MRI-based 3D models and CT-based 3D models was 0.953 (P < .001). The location of impingement was not significantly different between manual and automatic segmentation of MRI-based 3D models, and the location of extra-articular hip impingement was not different between CT- and MRI-based 3D models. CONCLUSION: CNN can potentially be used in clinical practice to provide rapid and accurate 3D MRI hip joint models for young patients. The created models can be used for simulation of impingement during diagnosis of intra- and extra-articular hip impingement to enable radiation-free and patient-specific surgical planning for hip arthroscopy and open hip preservation surgery.

2.
Eur J Radiol Open ; 8: 100303, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33364259

RESUMO

INTRODUCTION: Both Hip Dysplasia(DDH) and Femoro-acetabular-Impingement(FAI) are complex three-dimensional hip pathologies causing hip pain and osteoarthritis in young patients. 3D-MRI-based models were used for radiation-free computer-assisted surgical planning. Automatic segmentation of MRI-based 3D-models are preferred because manual segmentation is time-consuming.To investigate(1) the difference and(2) the correlation for femoral head coverage(FHC) between automatic MR-based and manual CT-based 3D-models and (3) feasibility of preoperative planning in symptomatic patients with hip diseases. METHODS: We performed an IRB-approved comparative, retrospective study of 31 hips(26 symptomatic patients with hip dysplasia or FAI). 3D MRI sequences and CT scans of the hip were acquired. Preoperative MRI included axial-oblique T1 VIBE sequence(0.8 mm3 isovoxel) of the hip joint. Manual segmentation of MRI and CT scans were performed. Automatic segmentation of MRI-based 3D-models was performed using deep learning. RESULTS: (1)The difference between automatic and manual segmentation of MRI-based 3D hip joint models was below 1 mm(proximal femur 0.2 ±â€¯0.1 mm and acetabulum 0.3 ±â€¯0.5 mm). Dice coefficients of the proximal femur and the acetabulum were 98 % and 97 %, respectively. (2)The correlation for total FHC was excellent and significant(r = 0.975, p < 0.001) between automatic MRI-based and manual CT-based 3D-models. Correlation for total FHC (r = 0.979, p < 0.001) between automatic and manual MR-based 3D models was excellent.(3)Preoperative planning and simulation of periacetabular osteotomy was feasible in all patients(100 %) with hip dysplasia or acetabular retroversion. CONCLUSIONS: Automatic segmentation of MRI-based 3D-models using deep learning is as accurate as CT-based 3D-models for patients with hip diseases of childbearing age. This allows radiation-free and patient-specific preoperative simulation and surgical planning of periacetabular osteotomy for patients with DDH.

3.
Am J Sports Med ; 47(12): 2966-2977, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31486679

RESUMO

BACKGROUND: Femoroacetabular impingement (FAI) is a complex 3-dimensional (3D) hip abnormality that can cause hip pain and osteoarthritis in young and active patients of childbearing age. Imaging is static and based on 2-dimensional radiographs or computed tomography (CT) scans. Recently, CT-based 3D impingement simulation was introduced for patient-specific assessments of hip deformities, whereas magnetic resonance imaging (MRI) offers a radiation-free alternative for surgical planning before hip arthroscopic surgery. PURPOSE: To (1) investigate the difference between 3D models of the hip, (2) correlate the location of hip impingement and range of motion (ROM), and (3) correlate diagnostic parameters while comparing CT- and MRI-based osseous 3D models of the hip in symptomatic patients with FAI. STUDY DESIGN: Cohort study (Diagnosis); Level of evidence, 2. METHODS: The authors performed an institutional review board-approved comparative and retrospective study of 31 hips in 26 symptomatic patients with FAI. We compared CT- and MRI-based osseous 3D models of the hip in the same patients. 3D CT scans (slice thickness, 1 mm) of the entire pelvis and the distal femoral condyles were obtained. Preoperative MRI of the hip was performed including an axial-oblique T1 VIBE sequence (slice thickness, 1 mm) and 2 axial anisotropic (1.2 × 1.2 × 1 mm) T1 VIBE Dixon sequences of the entire pelvis and the distal femoral condyles. Threshold-based semiautomatic reconstruction of 3D models was performed using commercial software. CT- and MRI-based 3D models were compared with specifically developed software. RESULTS: (1) The difference between MRI- and CT-based 3D models was less than 1 mm for the proximal femur and the acetabulum (median surface distance, 0.4 ± 0.1 mm and 0.4 ± 0.2 mm, respectively). (2) The correlation for ROM values was excellent (r = 0.99, P < .001) between CT and MRI. The mean absolute difference for flexion and extension was 1.9°± 1.5° and 2.6°± 1.9°, respectively. The location of impingement did not differ between CT- and MRI-based 3D ROM analysis in all 12 of 12 acetabular and 11 of 12 femoral clock-face positions. (3) The correlation for 6 diagnostic parameters was excellent (r = 0.98, P < .001) between CT and MRI. The mean absolute difference for inclination and anteversion was 2.0°± 1.8° and 1.0°± 0.8°, respectively. CONCLUSION: Patient-specific and radiation-free MRI-based dynamic 3D simulation of hip impingement and ROM can replace CT-based 3D simulation for patients with FAI of childbearing age. On the basis of these excellent results, we intend to change our clinical practice, and we will use MRI-based 3D models for future clinical practice instead of CT-based 3D models. This allows radiation-free and patient-specific preoperative 3D impingement simulation for surgical planning and simulation of open hip preservation surgery and hip arthroscopic surgery.


Assuntos
Artroscopia , Impacto Femoroacetabular/diagnóstico por imagem , Impacto Femoroacetabular/cirurgia , Quadril/diagnóstico por imagem , Quadril/fisiopatologia , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Acetábulo/diagnóstico por imagem , Adolescente , Adulto , Estudos de Coortes , Feminino , Impacto Femoroacetabular/fisiopatologia , Fêmur/diagnóstico por imagem , Humanos , Masculino , Pelve/diagnóstico por imagem , Amplitude de Movimento Articular , Estudos Retrospectivos , Rotação , Tomografia Computadorizada por Raios X , Adulto Jovem