Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
JMIR Mhealth Uhealth ; 8(5): e16674, 2020 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-32282332

RESUMO

BACKGROUND: Wearable trackers for monitoring physical activity (PA) and total sleep time (TST) are increasingly popular. These devices are used not only by consumers to monitor their behavior but also by researchers to track the behavior of large samples and by health professionals to implement interventions aimed at health promotion and to remotely monitor patients. However, high costs and accuracy concerns may be barriers to widespread adoption. OBJECTIVE: This study aimed to investigate the concurrent validity of 6 low-cost activity trackers for measuring steps, moderate-to-vigorous physical activity (MVPA), and TST: Geonaut On Coach, iWown i5 Plus, MyKronoz ZeFit4, Nokia GO, VeryFit 2.0, and Xiaomi MiBand 2. METHODS: A free-living protocol was used in which 20 adults engaged in their usual daily activities and sleep. For 3 days and 3 nights, they simultaneously wore a low-cost tracker and a high-cost tracker (Fitbit Charge HR) on the nondominant wrist. Participants wore an ActiGraph GT3X+ accelerometer on the hip at daytime and a BodyMedia SenseWear device on the nondominant upper arm at nighttime. Validity was assessed by comparing each tracker with the ActiGraph GT3X+ and BodyMedia SenseWear using mean absolute percentage error scores, correlations, and Bland-Altman plots in IBM SPSS 24.0. RESULTS: Large variations were shown between trackers. Low-cost trackers showed moderate-to-strong correlations (Spearman r=0.53-0.91) and low-to-good agreement (intraclass correlation coefficient [ICC]=0.51-0.90) for measuring steps. Weak-to-moderate correlations (Spearman r=0.24-0.56) and low agreement (ICC=0.18-0.56) were shown for measuring MVPA. For measuring TST, the low-cost trackers showed weak-to-strong correlations (Spearman r=0.04-0.73) and low agreement (ICC=0.05-0.52). The Bland-Altman plot revealed a variation between overcounting and undercounting for measuring steps, MVPA, and TST, depending on the used low-cost tracker. None of the trackers, including Fitbit (a high-cost tracker), showed high validity to measure MVPA. CONCLUSIONS: This study was the first to examine the concurrent validity of low-cost trackers. Validity was strongest for the measurement of steps; there was evidence of validity for measurement of sleep in some trackers, and validity for measurement of MVPA time was weak throughout all devices. Validity ranged between devices, with Xiaomi having the highest validity for measurement of steps and VeryFit performing relatively strong across both sleep and steps domains. Low-cost trackers hold promise for monitoring and measurement of movement and sleep behaviors, both for consumers and researchers.


Assuntos
Acelerometria , Monitorização Ambulatorial , Adulto , Exercício Físico , Humanos , Reprodutibilidade dos Testes , Sono
2.
JMIR Res Protoc ; 8(3): e12413, 2019 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-30901002

RESUMO

BACKGROUND: Adoption of an active lifestyle plays an important role in the management of type 2 diabetes. Online interventions targeting lifestyle changes in adults with type 2 diabetes have provided mixed results. Previous research highlights the importance of creating theory-based interventions adapted to the population's specific needs. The online intervention "MyPlan 2.0" targets physical activity and sedentary behavior in adults with type 2 diabetes. This intervention is grounded in the self-regulation framework and, by incorporating the feedback of users with type 2 diabetes, iteratively adapted to its target population. OBJECTIVE: The aim of this paper is to thoroughly describe "MyPlan 2.0" and the study protocol that will be used to test the effectiveness of this intervention to alter patients' levels of physical activity and sedentary behavior. METHODS: A two-arm superiority randomized controlled trial will be performed. Physical activity and sedentary behavior will be measured using accelerometers and questionnaires. Furthermore, using questionnaires and diaries, patients' stressors and personal determinants for change will be explored in depth. To evaluate the primary outcomes of the intervention, multilevel analyses will be conducted. RESULTS: The randomized controlled trial started in January 2018. As participants can start at different moments, we aim to finish all testing by July 2019. CONCLUSIONS: This study will increase our understanding about whether and how a theory-based online intervention can help adults with type 2 diabetes increase their level of physical activity and decrease their sedentary time. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/12413.

3.
JMIR Mhealth Uhealth ; 6(12): e10972, 2018 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-30545810

RESUMO

BACKGROUND: Wearables for monitoring physical activity (PA) are increasingly popular. These devices are not only used by consumers to monitor their own levels of PA but also by researchers to track the behavior of large samples. Consequently, it is important to explore how accurately PA can be tracked via these devices. OBJECTIVES: The aim of this study was, therefore, to investigate convergent validity of 3 Android Wear smartwatches-Polar M600 (Polar Electro Oy, Kempele, Finland), Huawei Watch (Huawei Technologies Co, Ltd, Shenzhen, Guangdong, China), Asus Zenwatch3 (AsusTek Computer Inc, Taipei, Taiwan)-and Fitbit Charge with an ActiGraph accelerometer for measuring steps and moderate to vigorous physical activity (MVPA) on both a day level and 15-min level. METHODS: A free-living protocol was used in which 36 adults engaged in usual daily activities over 2 days while wearing 2 different wearables on the nondominant wrist and an ActiGraph GT3X+ accelerometer on the hip. Validity was evaluated on both levels by comparing each wearable with the ActiGraph GT3X+ accelerometer using correlations and Bland-Altman plots in IBM SPSS 24.0. RESULTS: On a day level, all devices showed strong correlations (Spearman r=.757-.892) and good agreement (interclass correlation coefficient, ICC=.695-.885) for measuring steps, whereas moderate correlations (Spearman r=.557-.577) and low agreement (ICC=.377-.660) for measuring MVPA. Bland-Altman revealed a systematic overestimation of the wearables for measuring steps but a variation between over- and undercounting of MVPA. On a 15-min level, all devices showed strong correlations (Spearman r=.752-.917) and good agreement (ICC=.792-.887) for measuring steps, whereas weak correlations (Spearman r=.116-.208) and low agreement (ICC=.461-.577) for measuring MVPA. Bland-Altman revealed a systematic overestimation of the wearables for steps but under- or overestimation for MVPA depending on the device. CONCLUSIONS: In sum, all 4 consumer-level devices can be considered accurate step counters in free-living conditions. This study, however, provides evidence of systematic bias for all devices in measurement of MVPA. The results on a 15-min level also indicate that these devices are not sufficiently accurate to provide correct real-time feedback.

4.
Artigo em Inglês | MEDLINE | ID: mdl-29385770

RESUMO

Physical inactivity is one of the major risk factors for poor health in the world. Therefore, effective interventions that promote physical activity are needed. Hence, we developed an eHealth intervention for adults, i.e., 'MyPlan 1.0', which includes self-regulation techniques for behaviour change. This study examined the effect of 'MyPlan 1.0' on physical activity (PA) levels in general practice. 615 adults (≥18 years) were recruited in 19 Flemish general practices, for the intervention group (n = 328) or for the wait-list control group (n = 183). Participants in the intervention group received the web-based intervention 'MyPlan 1.0' and were prompted to discuss their personal advice/action plan with their general practitioner. Participants in the wait-list control group only received general advice from the website. Self-reported physical activity was assessed with the International Physical Activity Questionnaire (IPAQ) at baseline and after one month. A three-level (general practice, adults, time) regression analysis was conducted in MLwiN. Significant intervention effects were found for total PA and moderate to vigorous PA with an increase for the intervention group compared to a decrease in the control condition. However, there was a high dropout rate in the intervention group (76%) and the wait-list control group (57%). Our self-regulation intervention was effective in increasing physical activity levels in adults. Future studies should consider strategies to prevent the large dropout from participants.


Assuntos
Exercício Físico/fisiologia , Medicina Geral , Promoção da Saúde/métodos , Telemedicina/métodos , Adulto , Feminino , Comportamentos Relacionados com a Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Autorrelato
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA