1.
Kidney Int ; 105(2): 338-346, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37918791

RESUMO

Precise determination of circulating parathyroid hormone (PTH) concentration is crucial to diagnose and manage various disease conditions, including the chronic kidney disease-mineral and bone disorder. However, the lack of standardization in PTH assays is challenging for clinicians, potentially leading to medical errors because the different assays do not provide equivalent results and use different reference ranges. Here, we aimed to evaluate the impact of recalibrating PTH immunoassays by means of a recently developed LC-MS/MS method as the reference. Utilizing a large panel of pooled plasma samples with PTH concentrations determined by the LC-MS/MS method calibrated with the World Health Organization (WHO) 95/646 International Standard, five PTH immunoassays were recalibrated. The robustness of this standardization was evaluated over time using different sets of samples. The recalibration successfully reduced inter-assay variability with harmonization of PTH measurements across different assays. By recalibrating the assays based on the WHO 95/646 International Standard, we demonstrated the feasibility for standardizing PTH measurement results and adopting common reference ranges for PTH assays, facilitating a more consistent interpretation of PTH values. The recalibration process aligns PTH results obtained from various immunoassays with the LC-MS/MS method, providing more consistent and reliable measurements. Thus, establishing true standardization across all PTH assays is crucial to ensure consistent interpretation and clinical decision-making.


Assuntos
Distúrbio Mineral e Ósseo na Doença Renal Crônica , Insuficiência Renal Crônica , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem , Hormônio Paratireóideo , Insuficiência Renal Crônica/diagnóstico
3.
Clin Chem ; 69(11): 1227-1237, 2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37725906

RESUMO

It is important for external quality assessment materials (EQAMs) to be commutable with clinical samples; i.e., they should behave like clinical samples when measured using end-user clinical laboratory in vitro diagnostic medical devices (IVD-MDs). Using commutable EQAMs makes it possible to evaluate metrological traceability and/or equivalence of results between IVD-MDs. The criterion for assessing commutability of an EQAM between 2 IVD-MDs is that its result should be within the prediction interval limits based on the statistical distribution of the clinical sample results from the 2 IVD-MDs being compared. The width of the prediction interval is, among other things, dependent on the analytical performance characteristics of the IVD-MDs. A presupposition for using this criterion is that the differences in nonselectivity between the 2 IVD-MDs being compared are acceptable. An acceptable difference in nonselectivity should be small relative to the analytical performance specifications used in the external quality assessment scheme. The acceptable difference in nonselectivity is used to modify the prediction interval criterion for commutability assessment. The present report provides recommendations on how to establish a criterion for acceptable commutability for EQAMS, establish the difference in nonselectivity that can be accepted between IVD-MDs, and perform a commutability assessment. The report also contains examples for performing a commutability assessment of EQAMs.


Assuntos
Serviços de Laboratório Clínico , Ensaio de Proficiência Laboratorial , Humanos , Padrões de Referência , Kit de Reagentes para Diagnóstico
4.
Clin Chem ; 69(9): 966-975, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37566391

RESUMO

A secondary higher-order calibrator is required to be commutable with clinical samples to be suitable for use in the calibration hierarchy of an end-user clinical laboratory in vitro diagnostic medical device (IVD-MD). Commutability is a property of a reference material that means results for a reference material and for clinical samples have the same numeric relationship, within specified limits, across the measurement procedures for which the reference material is intended to be used. Procedures for assessing commutability have been described in the literature. This report provides recommendations for establishing a quantitative criterion to assess the commutability of a certified reference material (CRM). The criterion is the maximum allowable noncommutability bias (MANCB) that allows a CRM to be used as a calibrator in a calibration hierarchy for an IVD-MD without exceeding the maximum allowable combined standard uncertainty for a clinical sample result (umaxCS). Consequently, the MANCB is derived as a fraction of the umaxCS for the measurand. The suitability of an MANCB for practical use in a commutability assessment is determined by estimating the number of measurements of clinical samples and CRMs required based on the precision performance and nonselectivity for the measurand of the measurement procedures in the assessment. Guidance is also provided for evaluating indeterminate commutability conclusions and how to report results of a commutability assessment.

5.
Alzheimers Dement (Amst) ; 15(3): e12465, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37600860

RESUMO

Fluid biomarkers are currently measured in cerebrospinal fluid and blood for Alzheimer's disease diagnosis and are promising targets for drug development and for patients' follow-up in clinical trials. These biomarkers have been grouped in an unbiased research framework, the amyloid (Aß), tau, and neurodegeneration (AT[N]) biomarker system to aid patients' early diagnosis and stratification. Metrological approaches relying on mass spectrometry have been used for the development of reference materials and reference measurement procedures. Despite their excellent performances as clinical tools, fluid biomarkers often present an important between-laboratory variation. Standardization efforts were carried out on the biomarkers currently included in the AT(N) classification system, involving the collaboration of national metrology institutes, clinicians, researchers, and in vitro diagnostic providers. This article provides an overview of current activities towards standardization. These reference methods and reference materials may be used for recalibration of immunoassays and the establishment of standardized cutoff values allowing a better stratification of Alzheimer's disease patients. Highlights: The AT(N) biomarker system allows stratifying AD patients on the basis of biomarker profiles.Fluid biomarker measurements often present an important between-laboratory variation preventing the establishment of standardized cutoff values.Overview on the standardization initiatives involving the fluid biomarkers currently included in the AT(N) framework.

6.
Clin Chem Lab Med ; 61(7): 1235-1244, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-36815732

RESUMO

OBJECTIVES: In clinical pratice, tau protein measurement generally relies on immunoassays (IAs), whose major drawback is the lack of results comparability due to differences in selectivity and/or calibration. This underlines the importance of establishing a traceability chain for total tau (t-tau) measurements. The objective of this work is to develop a higher order candidate reference measurement procedure (RMP) for the absolute quantification of t-tau in cerebrospinal fluid (CSF). METHODS: To calibrate the candidate RMP and establish metrological traceability to the SI units, a primary calibrator consisting in a highly purified recombinant protein was sourced. Its purity was evaluated by liquid chromatography coupled with high resolution mass spectrometry (LC-HRMS) and the protein mass fraction in solution was certified by amino acid analysis (AAA). An isotopically-labelled homologue was obtained to develop a candidate RMP by isotope dilution mass spectrometry (IDMS) for t-tau absolute quantification in CSF. Calibration blends and quality control (QC) materials were gravimetrically prepared and subjected to the same preparation workflow as CSF samples, followed by LC-HRMS analysis in Parallel Reaction Monitoring (PRM) mode. RESULTS: A primary calibrator has been developed and an IDMS candidate RMP has been validated for CSF t-tau. The candidate RMP was used to certify t-tau concentration in three pools of CSF (low, medium, high). CONCLUSIONS: The candidate RMP will pave the road towards global standardization of CSF t-tau measurements. Together with commutable Certified Reference Materials (CRMs), it will allow evaluating and improving the accuracy and comparability of results provided by IAs.


Assuntos
Espectrometria de Massas em Tandem , Proteínas tau , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Padrões de Referência , Aminoácidos/análise , Calibragem
7.
Clin Chem ; 69(3): 251-261, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36644914

RESUMO

BACKGROUND: Medical results generated by European CE Marking for In Vitro Diagnostic or in-house tests should be traceable to higher order reference measurement systems (RMS), such as International Federation of Clinical Chemistry and Laboratory Medicine (IFCC)-endorsed reference measurement procedures (RMPs) and reference materials. Currently, serum apolipoprotein (a) [apo(a)] is recognized as a novel risk factor for cardiovascular risk assessment and patient management. The former RMS for serum apo(a) is no longer available; consequently, an International System of Units (SI)-traceable, ideally multiplexed, and sustainable RMS for apo(a) is needed. METHODS: A mass spectrometry (MS)-based candidate RMP (cRMP) for apo(a) was developed using quantitative bottom-up proteomics targeting 3 proteotypic peptides. The method was provisionally validated according to ISO 15193 using a single human serum based calibrator traceable to the former WHO-IFCC RMS. RESULTS: The quantitation of serum apo(a) was by design independent of its size polymorphism, was linear from 3.8 to 456 nmol/L, and had a lower limit of quantitation for apo(a) of 3.8 nmol/L using peptide LFLEPTQADIALLK. Interpeptide agreement showed Pearson Rs of 0.987 and 0.984 for peptides GISSTVTGR and TPENYPNAGLTR, and method comparison indicated good correspondence (slopes 0.977, 1.033, and 1.085 for LFLEPTQADIALLK, GISSTVTGR, and TPENYPNAGLTR). Average within-laboratory imprecision of the cRMP was 8.9%, 11.9%, and 12.8% for the 3 peptides. CONCLUSIONS: A robust, antibody-independent, MS-based cRMP was developed as higher order RMP and an essential part of the apo(a) traceability chain and future RMS. The cRMP fulfils predefined analytical performance specifications, making it a promising RMP candidate in an SI-traceable MS-based RMS for apo(a).


Assuntos
Peptídeos , Soro , Humanos , Apoproteína(a) , Espectrometria de Massas , Padrões de Referência , Calibragem
8.
Clin Chem ; 69(3): 262-272, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36644921

RESUMO

BACKGROUND: Elevated concentrations of lipoprotein(a) [Lp(a)] are directly related to an increased risk of cardiovascular diseases, making it a relevant biomarker for clinical risk assessment. However, the lack of global standardization of current Lp(a) measurement procedures (MPs) leads to inconsistent patient care. The International Federation for Clinical Chemistry and Laboratory Medicine working group on quantitating apolipoproteins by mass spectrometry (MS) aims to develop a next-generation SI (International system of units)-traceable reference measurement system consisting of a MS-based, peptide-calibrated reference measurement procedure (RMP) and secondary serum-based reference materials (RMs) certified for their apolipoprotein(a) [apo(a)] content. To reach measurement standardization through this new measurement system, 2 essential requirements need to be fulfilled: a sufficient correlation among the MPs and appropriate commutability of future serum-based RMs. METHODS: The correlation among the candidate RMP (cRMP) and immunoassay-based MPs was assessed by measuring a panel of 39 clinical samples (CS). In addition, the commutability of 14 different candidate RMs was investigated. RESULTS: Results of the immunoassay-based MPs and the cRMPs demonstrated good linear correlations for the CS but some significant sample-specific differences were also observed. The results of the commutability study show that RMs based on unspiked human serum pools can be commutable with CS, whereas human pools spiked with recombinant apo(a) show different behavior compared to CS. CONCLUSIONS: The results of this study show that unspiked human serum pools are the preferred candidate secondary RMs in the future SI-traceable Lp(a) Reference Measurement System.


Assuntos
Química Clínica , Lipoproteína(a) , Humanos , Imunoensaio , Espectrometria de Massas , Padrões de Referência
9.
Clin Chem Lab Med ; 61(7): 1245-1254, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-36709509

RESUMO

OBJECTIVES: Neurofilament light chain (NfL) concentration in blood is a biomarker of neuro-axonal injury in the nervous system and there now exist several assays with high enough sensitivity to measure NfL in serum and plasma. There is a need for harmonization with the goal of creating a certified reference material (CRM) for NfL and an early step in such an effort is to determine the best matrix for the CRM. This is done in a commutability study and here the results of the first one for NfL in blood is presented. METHODS: Forty paired individual serum and plasma samples were analyzed for NfL on four different analytical platforms. Neat and differently spiked serum and plasma were evaluated for their suitability as a CRM using the difference in bias approach. RESULTS: The correlation between the different platforms with regards to measured NfL concentrations were very high (Spearman's ρ≥0.96). Samples spiked with cerebrospinal fluid (CSF) showed higher commutability compared to samples spiked with recombinant human NfL protein and serum seems to be a better choice than plasma as the matrix for a CRM. CONCLUSIONS: The results from this first commutability study on NfL in serum/plasma showed that it is feasible to create a CRM for NfL in blood and that spiking should be done using CSF rather than with recombinant human NfL protein.


Assuntos
Filamentos Intermediários , Proteínas de Neurofilamentos , Humanos , Soro , Plasma , Padrões de Referência , Biomarcadores , Proteínas Recombinantes
10.
J Clin Virol ; 158: 105352, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36525853

RESUMO

BACKGROUND: The detection of SARS-CoV-2 vRNA in clinical samples has relied almost exclusively on RT-qPCR as the gold standard test. Published results from various external quality assessments ("ring trials") worldwide have shown that there is still a large variability in results reported for the same samples. As reference standards of SARS-CoV-2 RNA are available, we tested whether using standard curves to convert Ct values into copies/mL (cp/mL) improved harmonization. METHODS: Nine laboratories using 23 test systems (15 of which were unique) prepared standard dilution curves to convert Ct values of 13 SARS-CoV-2 positive samples to cp/mL (hereafter IU/mL). The samples were provided in three rounds of a virus genome detection external quality assessment (EQA) scheme. We tested the precision and accuracy of results reported in IU/mL, and attempted to identify the sources of variability. RESULTS: Reporting results as IU/mL improved the precision of the estimated concentrations of all samples compared to reporting Ct values, although some inaccuracy remained. Variance analysis showed that nearly all variability in data was explained by individual test systems within individual laboratories. When controlling for this effect, there was no significant difference between all other factors tested (test systems, EQA rounds, sample material). CONCLUSIONS: Converting results to copies/mL improved precision across laboratory test systems. However, it seems the results are still very specific to test systems within laboratories. Further efforts could be made to improve accuracy and achieve full harmonization across diagnostic laboratories.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , RNA Viral/genética , RNA Viral/análise , Teste para COVID-19 , Laboratórios , Sensibilidade e Especificidade
12.
Anal Chem ; 94(10): 4146-4154, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35235744

RESUMO

Procalcitonin (PCT) is a widely used biomarker for rapid sepsis diagnosis and antibiotic stewardship. Variability of results in commercial assays has highlighted the need for standardization of PCT measurements. An antibody-free candidate reference measurement procedure (RMP) based on the isotope dilution mass spectrometry and protein calibration approach was developed and validated to quantify PCT in human serum. The method allows quantification of PCT from 0.25 to 13.74 µg/L (R > 0.998) with extension up to 132 µg/L after dilution of samples with PCT concentration above 13.74 µg/L. Intraday bias was between -3.3 and +5.7%, and interday bias was between -3.0 and -0.7%. Intraday precision was below 5.1%, and interday precision was below 4.0%. The candidate RMP was successfully applied to the absolute quantification of PCT in five frozen human serum pools. A recombinant PCT used as a primary calibrator was characterized by high-resolution mass spectrometry and amino acid analysis to establish traceability of the results to the SI units. This candidate RMP is fit to assign target values to secondary certified reference materials (CRMs) for further use in external quality assessment schemes to monitor the accuracy and comparability of the commercially available immunoassay results and to confirm the need for improving the harmonization of PCT assays. The candidate RMP will also be used to evaluate whether the correlation between the candidate RMP and immunoassays is sufficiently high. Overall, this candidate RMP will support reliable sepsis diagnosis and guide treatment decisions, patient monitoring, and outcomes.


Assuntos
Pró-Calcitonina , Sepse , Calibragem , Humanos , Espectrometria de Massas , Proteínas Recombinantes , Padrões de Referência , Sepse/diagnóstico
13.
Clin Chem Lab Med ; 60(5): 669-674, 2022 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-35179002

RESUMO

The role of an External Quality Assurance (EQA) program is generally seen as providing a service to routine laboratories that their analytical performance is satisfactory and stimulating corrective action in the event of poor results. It is recognised that an ideal EQA program uses materials that are commutable with patient samples and have values assigned by higher-order reference methods. Despite this, most routine EQA programs use materials without verified commutability and use consensus means (based on either peer group or all laboratories) as target values. We propose an ongoing role for EQA programs using non-commutable materials and consensus targets to support the measurement services of routine laboratories. This is provided the relevant comparators supplied by the laboratory, e.g. reference intervals and clinical decision points, are based on the same or equivalent measurement system as is used by the laboratory. Materials without verified commutability often have certain practical advantages, which may include the range of analyte concentrations, verified stability, replicate samples and, significantly, lower costs. Laboratories using such programs need to be aware of the limitations, especially comparing results from different measurement systems. However, we also recognise that as well as individual laboratories, data from EQA programs informs manufacturers, professional organisations, clinical guideline writers and other medical bodies For consideration beyond an individual laboratory, proper assessment of differences between measurement systems (results harmonization) and demonstration of correct implementation of metrological traceability (methods trueness) become vital, and for that purpose, commutability of EQA materials and traceability of target values are required.


Assuntos
Laboratórios , Humanos , Controle de Qualidade , Padrões de Referência
15.
Clin Chem ; 67(12): 1590-1605, 2021 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-34633037

RESUMO

BACKGROUND: The JCTLM created a Task Force on Reference Measurement System Implementation (TF-RMSI) to provide guidance on metrological traceability implementation for the in vitro diagnostics (IVD) community. CONTENT: TF-RMSI investigated the reference measurement systems (RMS) for 13 common measurands by applying the following procedural steps: (a) extracting data from the JCTLM database of available certified reference materials (CRMs) and reference measurement procedures (RMPs); (b) describing the RMS to which each recruited CRM or RMP belongs; (c) identifying the intended use of the CRMs, and, if used as a common calibrator for IVD measuring systems and/or trueness assessment of field methods was included, checking the CRM's certificate for information about commutability with clinical samples; and (d) checking if the CRM or RMP measurement uncertainty (MU) has the potential to be small enough to avoid significantly affecting the analytical performance specifications (APS) for MU of clinical sample results when the MU from the IVD calibrator and from the end-user measuring system were combined. SUMMARY: We produced a synopsis of JCTLM-listed higher-order CRMs and RMPs for the selected measurands, including their main characteristics for implementing traceability and fulfilling (or not) the APS for suitable MU. Results showed that traceability to higher-order references can be established by IVD manufacturers within the defined APS for most of the 13 selected measurands. However, some measurands do not yet have suitable CRMs for use as common calibrators. For these measurands, splitting clinical samples with a laboratory performing the RMP may provide a practical alternative for establishing a calibration hierarchy.


Assuntos
Laboratórios , Calibragem , Bases de Dados Factuais , Humanos , Padrões de Referência , Incerteza
17.
Clin Chem Lab Med ; 59(10): 1610-1622, 2021 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-34147043

RESUMO

Sepsis represents a global health priority because of its high mortality and morbidity. The key to improving prognosis remains an early diagnosis to initiate appropriate antibiotic treatment. Procalcitonin (PCT) is a recognized biomarker for the early indication of bacterial infections and a valuable tool to guide and individualize antibiotic treatment. To meet the increasing demand for PCT testing, numerous PCT immunoassays have been developed and commercialized, but results have been questioned. Many comparison studies have been carried out to evaluate analytical performance and comparability of results provided by the different commercially available immunoassays for PCT, but results are conflicting. External Quality Assessment Schemes (EQAS) for PCT constitute another way to evaluate results comparability. However, when making this comparison, it must be taken into account that the variety of EQA materials consist of different matrices, the commutability of which has not yet been investigated. The present study gathers results from all published comparison studies and results from 137 EQAS surveys to describe the current state-of-the-art harmonization of PCT results. Comparison studies globally highlight a significant variability of measurement results that nonetheless seem to have a moderate impact on medical decision-making. For their part, EQAS for PCT provides highly discrepant estimates of the interlaboratory CV. Due to differences in commutability of the EQA materials, the results from different peer groups could not be compared. To improve the informative value of the EQA data, the existing limitations such as non-harmonized conditions and suboptimal and/or unknown commutability of the EQA materials have to be overcome. The study highlights the need for commutable reference materials that could be used to properly evaluate result comparability and possibly standardize calibration, if necessary. Such an initiative would further improve the safe use of PCT in clinical routine.


Assuntos
Pró-Calcitonina , Sepse , Calibragem , Humanos , Imunoensaio , Controle de Qualidade , Sepse/diagnóstico
18.
Clin Chem Lab Med ; 59(10): 1735-1744, 2021 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-34187131

RESUMO

OBJECTIVES: External quality assessment (EQA) schemes provide information on individual and general analytical performance of participating laboratories and test systems. The aim of this study was to investigate the use and performance of SARS-CoV-2 virus genome detection systems in Austrian laboratories and their preparedness to face challenges associated with the pandemic. METHODS: Seven samples were selected to evaluate performance and estimate variability of reported results. Notably, a dilution series was included in the panel as a measure of reproducibility and sensitivity. Several performance criteria were evaluated for individual participants as well as in the cohort of all participants. RESULTS: A total of 109 laboratories participated and used 134 platforms, including 67 different combinations of extraction and PCR platforms and corresponding reagents. There were no false positives and 10 (1.2%) false negative results, including nine in the weakly positive sample (Ct ∼35.9, ∼640 copies/mL). Twenty (22%) laboratories reported results of mutation detection. Twenty-five (19%) test systems included amplification of human RNA as evidence of proper sampling. The overall linearity of Ct values from individual test systems for the dilution series was good, but inter-assay variability was high. Both operator-related and systematic failures appear to have caused incorrect results. CONCLUSIONS: Beyond providing certification for participating laboratories, EQA provides the opportunity for participants to evaluate their performance against others so that they may improve operating procedures and test systems. Well-selected EQA samples offer additional inferences to be made about assay sensitivity and reproducibility, which have practical applications.


Assuntos
COVID-19/diagnóstico , Genoma Viral , Garantia da Qualidade dos Cuidados de Saúde , SARS-CoV-2/isolamento & purificação , Áustria/epidemiologia , COVID-19/virologia , Humanos , Laboratórios , Técnicas de Diagnóstico Molecular/métodos , Pandemias , SARS-CoV-2/genética , Sensibilidade e Especificidade
19.
Anal Bioanal Chem ; 413(19): 4707-4725, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33987701

RESUMO

The quantification of low abundant proteins in complex matrices by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) remains challenging. A measurement procedure based on optimized antibody-free sample preparation and isotope dilution coupled to LC-MS/MS was developed to quantify procalcitonin (PCT) in human serum at sub-microgram per liter level. A combination of sodium deoxycholate-assisted protein precipitation with acetonitrile, solid-phase extraction, and trypsin digestion assisted with Tween-20 enhanced the method sensitivity. Linearity was established through peptide-based calibration curves in the serum matrix (0.092-5.222 µg/L of PCT) with a good linear fit (R2 ≥ 0.999). Quality control materials spiked with known amounts of protein-based standards were used to evaluate the method's accuracy. The bias ranged from -2.6 to +4.3%, and the intra-day and inter-day coefficients of variations (CVs) were below 2.2% for peptide-based quality controls. A well-characterized correction factor was determined and applied to compensate for digestion incompleteness and material loss before the internal standards spike. Results with metrological traceability to the SI units were established using standard peptide of well-characterized purity determined by peptide impurity corrected amino acid analysis. The validated method enables accurate quantification of PCT in human serum at a limit of quantification down to 0.245 µg/L (bias -1.9%, precision 9.1%). The method was successfully applied to serum samples obtained from patients with sepsis. Interestingly, the PCT concentration reported implementing the isotope dilution LC-MS/MS method was twofold lower than the concentration provided by an immunoassay.


Assuntos
Calcitonina/química , Espectrometria de Massas/métodos , Pró-Calcitonina/química , Soro/química , Sequência de Aminoácidos , Calibragem , Cromatografia Líquida/métodos , Humanos , Sensibilidade e Especificidade
20.
Lancet ; 397(10279): 1085-1094, 2021 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-33711294

RESUMO

BACKGROUND: In cardiovascular disease, prevention strategies targeting standard modifiable cardiovascular risk factors (SMuRFs; hypertension, diabetes, hypercholesterolaemia, and smoking) are crucial; however, myocardial infarction in the absence of SMuRFs is not infrequent. The outcomes of individuals without SMuRFs are not well known. METHODS: We retrospectively analysed adult patients with first-presentation ST-elevation myocardial infarction (STEMI) using data from the Swedish myocardial infarction registry SWEDEHEART. Clinical characteristics and outcomes of adult patients (age ≥18 years) with and without SMuRFs were examined overall and by sex. Patients with a known history of coronary artery disease were excluded. The primary outcome was all-cause mortality at 30 days after STEMI presentation. Secondary outcomes included cardiovascular mortality, heart failure, and myocardial infarction at30 days. Endpoints were also examined up to discharge, and to the end of a 12-year follow-up. Multivariable logistic regression models were used to compare in-hospital mortality, and Cox-proportional hazard models and Kaplan-Meier analysis for long-term outcomes. FINDINGS: Between Jan 1, 2005, and May 25, 2018, 9228 (14·9%) of 62 048 patients with STEMI had no SMuRFs reaching diagnostic thresholds. Median age was similar between patients with SMuRFs and patients without SMuRFs (68 years [IQR 59-78]) vs 69 years [60-78], p<0·0001). SMuRF-less patients had a similar rate of percutaneous coronary intervention to those with at least one modifiable risk factor, but were significantly less likely to receive statins, angiotensin converting enzyme inhibitors (ACEIs) or angiotensin receptor blockade (ARB), or ß-blockers at discharge. By 30 days after presentation, all-cause mortality was significantly higher in SMuRF-less patients (hazard ratio 1·47 [95% CI 1·37-1·57], p<0·0001). SMuRF-less women had the highest 30-day mortality (381 [17·6%] of 2164), followed by women with SMuRFs (2032 [11·1%] of 18 220), SMuRF-less men (660 [9·3%] of 7064), and men with SMuRFs (2117 [6·1%] of 34 600). The increased risk of 30-day all-cause mortality in SMuRF-less patients remained significant after adjusting for age, sex, left ventricular ejection fraction, creatinine, and blood pressure, but was attenuated on inclusion of pharmacotherapy prescription (ACEI or ARB, ß-blocker, or statin) at discharge. Additionally, SMuRF-less patients had a significantly higher rate of in-hospital all-cause mortality than patients with one or more SMuRF (883 [9·6%] vs 3411 [6·5%], p<0·0001). Myocardial infarction and heart failure at 30 days were lower in SMuRF-less patients. All-cause mortality remained increased in the SMuRF-less group for more than 8 years in men and up to the 12-year endpoint in women. INTERPRETATION: Individuals who present with STEMI in the absence of SMuRFs have a significantly increased risk of all-cause mortality, compared with those with at least one SMuRF, which was particularly evident in women. The increased early mortality rates are attenuated after adjustment for use of guideline-indicated treatments, highlighting the need for evidence-based pharmacotherapy during the immediate post-infarct period irrespective of perceived low risk. FUNDING: Swedish Heart and Lung Foundation, National Health and Medical Research Council (Australia).


Assuntos
Tratamento Farmacológico/normas , Insuficiência Cardíaca/mortalidade , Mortalidade Hospitalar/tendências , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/estatística & dados numéricos , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Antagonistas de Receptores de Angiotensina/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/prevenção & controle , Tratamento Farmacológico/métodos , Feminino , Fatores de Risco de Doenças Cardíacas , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Hipercolesterolemia , Hipertensão/tratamento farmacológico , Hipertensão/prevenção & controle , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Avaliação de Resultados em Cuidados de Saúde , Sistema de Registros , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Prevenção do Hábito de Fumar/normas , Suécia/epidemiologia
SELEÇÃO DE REFERÊNCIAS