Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 155: 108920, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31622844

RESUMO

The probabilities of locating peaks with a high relative peak-area uncertainty were determined empirically with nine types of peak-location software used in laboratories engaged in gamma-ray spectrometry measurements. It was found that it is not possible to locate peaks with a probability of 0.95, when they have a relative peak-area uncertainty in excess of 50%. Locating peaks at these relatively high peak-area uncertainties with a probability greater than 0.95 is only possible in the library-driven mode, where the peak positions are supposed a-priori. The deficiencies of the library-driven mode and the possibilities to improve the probabilities of locating peaks are briefly discussed.

2.
Appl Radiat Isot ; 109: 389-392, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26805708

RESUMO

(123)I is widely used for radiodiagnostic procedures. It is produced by reaction of (124)Xe (p,2n) (123)Cs →(123)Xe →(123)I in cyclotrons. (121)Te and (125)I appear in a photon energy spectrum as impurities. An activity of (121)Te was calibrated absolutely by sum-peak method and its photon emitting probability was estimated, whose results were consistent with published results.

3.
Appl Radiat Isot ; 109: 236-241, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26688362

RESUMO

Since the inception of its proficiency test program to evaluate radionuclide measurement in hospitals and clinics, the National Metrology Laboratory of Ionizing Radiation-LNMRI, that represents Brazilian National Metrology Institute (NMI) for ionizing radiation has expanded its measurement and calibration capability. Requirements from the National Health Surveillance Agency from Ministry of Health (ANVISA), to producers of radiopharmaceuticals provided an opportunity to improve the full traceability chain to the highest level. Fluorodeoxyglucose (FDG-(18)F) is the only radiopharmaceutical simultaneously produced by all Brazilian radiopharmaceutical production centers (RPCs). By running this proficiency test, LNMRI began to provide them with the required traceability. For evaluation, the ratio of RPC to reference value results and ISO/IEC17043:2010 criteria were used. The reference value established as calibration factor on the secondary standard ionization chamber was obtained from three absolute measurements systems, and routinely confirmed in each round of proficiency test by CIEMAT/NIST liquid scintillation counting. The γ-emitting impurities were checked using a High-Purity Germanium (HPGe) detector. The results show that Brazilian RPCs are in accordance with (accuracy within ±10%) the Brazilian standard for evaluation of measurements with radionuclide calibrators (CNEN NN 3.05., 2013). Nevertheless, the RPCs should improve the methodology of uncertainty estimates, essential when using the statistical criteria of ISO/IEC 17043 standard, in addition to improving accuracy to levels consistent with their position in the national traceability chain.


Assuntos
Radioisótopos de Flúor/análise , Radioisótopos de Flúor/normas , Setor Público/normas , Radiometria/métodos , Radiometria/normas , Brasil , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Appl Radiat Isot ; 109: 261-263, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26653211

RESUMO

(124)I is a radionuclide used in the diagnosis of tumors. The National Health Agency requires identification and activity measurement of impurities. Using gamma spectrometry with an efficiency calibrated high-purity germanium detector, impurities (125)I and (126)I in an (1)(24)I production sample were identified. Activity ratios of (125)I and (126)I to (124)I were approximately 0.5% and 98%, respectively.


Assuntos
Contaminação de Medicamentos/prevenção & controle , Radioisótopos do Iodo/análise , Radioisótopos do Iodo/normas , Radiometria/métodos , Radiometria/normas , Espectrometria gama/normas , Brasil , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria gama/métodos
5.
Appl Radiat Isot ; 70(9): 2056-9, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22417696

RESUMO

The National Laboratory for Metrology of Ionizing Radiation (LNMRI)/Brazil acquired (166m)Ho and (243)Am/(239)Np solutions from commercial suppliers in order to realize primary standardization and therefore reducing the associated uncertainties. The method used in the standardization was the live-timed 4πß(LS)-γ(ΝaI(Tl)) anticoincidence counting. The live-timed anticoincidence system is operated since 2006 in LNMRI and is composed of two MTR2 modules donated by Laboratoire National Henri Becquerel (LNE-LNHB)/France. The data acquisition system uses a homemade LabView program and an Excel file for calculus. These systems have been used for primary standardization at LNMRI for many radionuclides and recently took part in the (124)Sb and (177)Lu International Key Comparisons with good performance.


Assuntos
Amerício/análise , Amerício/normas , Hólmio/normas , Netúnio/análise , Netúnio/normas , Radiometria/normas , Software/normas , Amerício/química , Brasil , Meia-Vida , Hólmio/análise , Internacionalidade , Linguagens de Programação , Doses de Radiação , Padrões de Referência , Valores de Referência
6.
Appl Radiat Isot ; 70(9): 1924-6, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22406221

RESUMO

The National Laboratory for Metrology of Ionizing Radiation (LNMRI)/Brazil participated in the last (57)Co activity measurement comparison organized by IAEA, in 2008. This was made in order to realize primary standardization of this radionuclide and to reduce the measuring uncertainties in the laboratory. Additionally, one sample with 2.6g was taken from the IAEA master solution of (57)Co and was prepared to be used in the measurement of the radionuclide's half-life in an ionization chamber system. The (57)Co half-life was measured to be 271.82 (17) days.


Assuntos
Radioisótopos de Cobalto/análise , Radioisótopos de Cobalto/química , Radiometria/instrumentação , Radiometria/normas , Brasil , Meia-Vida , Internacionalidade , Doses de Radiação , Padrões de Referência , Valores de Referência
7.
Appl Radiat Isot ; 70(9): 2087-90, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22425414

RESUMO

A commercial solution of (65)Zn was standardized by the sum peak-method using a planar HPGe detector. The activity results were compared with measurements made with a well type 4πγ ionization chamber, which is traceable to BIPM.RI (II)-K2.Zn-65 key-comparison performed in 2002. The sum-peak value was 42.79 kBq/g and the ionization chamber value was 42.74 kBq/g both at the reference date. The uncertainty obtained in the sum peak standardization was 0.25% (k=1), and in the ionization chamber was 0.85% (k=1). The results showed that sum-peak method can be used in (65)Zn standardization and this method is easier, simpler and more practical than others methods.


Assuntos
Algoritmos , Radioisótopos/análise , Radioisótopos/normas , Radiometria/instrumentação , Radiometria/normas , Radioisótopos de Zinco/análise , Radioisótopos de Zinco/normas , Meia-Vida , Internacionalidade , Doses de Radiação , Radioisótopos/química , Padrões de Referência , Valores de Referência , Semicondutores , Radioisótopos de Zinco/química
8.
Appl Radiat Isot ; 70(7): 1373-5, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22154105

RESUMO

The manual version of the potentiometric titration method has been used for certification and characterization of uranium compounds. In order to reduce the analysis time and the influence of the analyst, a semi-automatic version of the method was developed in the Brazilian Nuclear Energy Commission. The method was applied with traceability assured by using a potassium dichromate primary standard. The combined standard uncertainty in determining the total concentration of uranium was around 0.01%, which is suitable for uranium characterization.

9.
Appl Radiat Isot ; 64(10-11): 1440-5, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16621584

RESUMO

The absolute 4pi-betagamma coincidence counting has been used to measure the activity concentrations of 54Mn and 203Hg, and the Sum-Peak method was used for 125I. 54Mn and 125I radionuclides have been part of international key-comparisons coordinated by the Bureau International des Poids et Measures (BIPM) in 2003/2004, while 203Hg is part of the traceability programme of the National Laboratory for Ionizing Radiation Metrology (LNMRI)/Brazil. Three different detectors were used for the Sum-Peak method: 3''x3'' NaI(Tl) and 5''x5'' well NaI(Tl) scintillation detectors and a planar germanium detector. Direct measurements were made of the photon emission probabilities of the 35.5-, 834.8- and 279.2-keV gamma-rays of 125I, 54Mn and 203Hg to give values of (0.0667+/-0.0014), (0.9997+/-0.0055) and (0.8161+/-0.0005), respectively. The half-lives of 203Hg and 54Mn were also determined by means of a 4pigamma ionization chamber (203Hg) and by the reference source method using a HPGe detector (54Mn) to give values of (46.639+/-0.023) days and (312.1+/-0.9) days, respectively.


Assuntos
Modelos Químicos , Radioisótopos/análise , Radioisótopos/normas , Radiometria/métodos , Brasil , Simulação por Computador , Guias como Assunto , Meia-Vida , Radioisótopos do Iodo/análise , Radioisótopos do Iodo/química , Radioisótopos do Iodo/normas , Manganês/análise , Manganês/química , Manganês/normas , Radioisótopos de Mercúrio/análise , Radioisótopos de Mercúrio/química , Radioisótopos de Mercúrio/normas , Doses de Radiação , Radioisótopos/química , Radiometria/normas , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Appl Radiat Isot ; 60(2-4): 341-6, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-14987665

RESUMO

Within the context of a joint project between VNIIM (D.I. Mendeleyev Institute for Metrology) and LNHB (Laboratoire National Henri Becquerel), special 226Ra sources were prepared by VNIIM in order to determine as accurately as possible the absolute photon emission probabilities for the main X- and gamma-rays following the decay of 226Ra and daughters. The main purpose of this work was to supplement a previous joint study by Laboratorio Nacional de Metrologia das Radiaçoes Ionizantes (LNMRI) and LNHB to determine their relative values. Some specific point sources were produced for alpha-spectrometry measurements that were undertaken at VNIIM and also for gamma-ray spectrometry studies at VNIIM and LNHB. The 226Ra activity for the gamma-spectrometric sources was measured relative to the alpha-spectrometric sources by comparing the counts of the main gamma-rays. The total uncertainty of the activity for these sources was 0.2% (k = 1). Using calibrated germanium detectors, several X- and gamma-ray spectra were analyzed to determine the absolute photon emission probabilities of 226Ra in radioactive equilibrium with daughters. The results are presented and compared to other published values.


Assuntos
Partículas alfa , Raios gama , Modelos Estatísticos , Prótons , Radiometria/métodos , Radônio/análise , Radônio/química , Raios X , Brasil , França , Cooperação Internacional , Radiometria/normas , Radônio/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria gama/métodos
11.
Appl Radiat Isot ; 54(3): 483-7, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11214885

RESUMO

A solution of 169Yb was absolutely standardized by the 4pi(EC,X)-gamma coincidence counting method and the result was used to obtain direct measurements of gamma-ray emission probabilities with a coaxial HPGe detector. The empirical relation proposed by (Vaño, F., Gonzalez, L., Gaeta R., Gonzalez, J.A., 1975. An empirical function which relates the slope of the Ge efficiency curves and the active volume Nucl. Instr. Meth. 123, 573) was tested using the gamma spectral response above 200 keV. The half-life of 169Yb was also measured with a 4pi gamma ionization chamber.

12.
Health Phys ; 60(1): 87-90, 1991 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-1983990

RESUMO

We are considering some aspects related to the decontamination activities of about 50 houses affected by 137Cs in Goiânia. We describe the way these contaminations occurred, the instruments used, and the procedures. We also discuss the dose limits established for decontamination and the consequences resulting from this action. We call attention to the importance of not only the technical aspects in such activities but also the psychosocial implications resulting from them.


Assuntos
Acidentes , Poluentes Radioativos do Ar , Radioisótopos de Césio , Descontaminação/métodos , Habitação , Brasil , Humanos , Teleterapia por Radioisótopo/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA