1.
J Clin Med ; 12(17)2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37685593

RESUMO

(200 w) Introduction. Remote monitoring (RM) of cardiac implantable electronic device (CIED) diagnostics helps to identify patients potentially at risk of worsening heart failure (HF). Additionally, knowledge of patient HF-related symptoms is crucial for decision making. Patient smartphone applications may represent an ideal option to remotely collect this information. PURPOSE: To assess real-world HF patient access, acceptance, and adherence to use of an HF-dedicated smartphone application (HF app). METHODS: In this study, 10 Italian hospitals administered a survey on smartphone/app use to HF patients with CIED. The subgroup who accepted it downloaded the HF app. Mean 1-year adherence of the HF app use was evaluated. RESULTS: A total of 495 patients (67 ± 13 years, 79% males, 26% NYHA III-IV) completed the survey, of which 84% had access to smartphones and 85% were willing to use the HF app. In total, 311/495 (63%) downloaded the HF app. Patients who downloaded the HF app were younger and had higher school qualification. Patients who were ≥60 years old had higher mean 1-year adherence (54.1%) than their younger counterparts (42.7%; p < 0.001). Hospitals with RM-dedicated staff had higher mean 1-year patient adherence (64.0% vs. 33.5%; p < 0.001). Adherence to HF app decreased from 63.3% (weeks_1-13) to 42.2% (weeks_40-52, p < 0.001). CONCLUSIONS: High access and acceptance of smartphones/apps by HF patients with CIED allow HF app use for RM of patient signs/symptoms. Younger patients with higher school qualifications are more likely to accept HF app; however, older patients have higher long-term adherence.

2.
Pacing Clin Electrophysiol ; 46(7): 674-683, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37279193

RESUMO

INTRODUCTION: Permanent His bundle pacing (HBP) is the most physiological pacing modality, and new implantation systems are now available. The aim of the present study was to describe and compare four different techniques to perform HBP. METHODS AND RESULTS: We included all consecutive patients who underwent a HBP attempt in our initial experience between June 2020 and May 2022. The success and characteristics of the procedure were compared among four implantation techniques: the Biotronik Selectra 3D sheath with Solia S60 lead (Selectra 3D), the Boston Scientific Site Selective Pacing Catheter with Ingevity lead (SSPC), the Abbott steerable stylet locator with Tendril lead (Locator), and the use of a standard stylet manually pre-shaped with a conventional pacing lead (Curved stylet). Ninety-eight patients (median age 79 years [interquartile range, 73-83], 83% men) were identified. The Selectra 3D technique was used in 43 procedures, SSPC in 26, Locator in 18 and Curved stylet in 11. The groups had similar clinical characteristics. Overall, procedural success was achieved in 91 patients (93%) with similar proportions among groups (p = .986). Fluoroscopy and procedural times were 6.0 (4.4-8.5) and 60 (45-75) min, respectively, without significant differences (p = .333 and p = .790). The rate of selective capture, the pacing threshold, and the paced QRS duration were also comparable. There was one pre-discharge HBP lead dislodgment (1%) that required implant revision. CONCLUSION: In our experience, four techniques for HBP achieved comparable results in terms of safety and effectiveness. The availability of different systems may lead to widespread use of physiological pacing.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Masculino , Humanos , Idoso , Feminino , Estimulação Cardíaca Artificial/métodos , Resultado do Tratamento , Cateterismo Cardíaco , Estudos Retrospectivos , Eletrocardiografia/métodos
3.
Int J Antimicrob Agents ; 61(3): 106734, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36690123

RESUMO

BACKGROUND: Infections of cardiovascular implantable electronic devices (CIED) are mainly due to Gram-positive bacteria (GPB). Data about Gram-negative bacteria CIED (GNB-CIED) infections are limited. This study aimed to investigate risk factors, clinical and diagnostic characteristics, and outcome of patients with GNB-CIED. METHODS: A multicentre, international, retrospective, case-control-control study was performed on patients undergoing CIED implantation from 2015 to 2019 in 17 centres across Europe. For each patient diagnosed with GNB-CIED, one matching control with GPB-CIED infection and two matching controls without infection were selected. RESULTS: A total of 236 patients were enrolled: 59 with GNB-CIED infection, 59 with GPB-CIED infection and 118 without infection. No between-group differences were found regarding clinical presentation, diagnostic and therapeutic management. A trend toward a higher rate of fluorodeoxyglucose positron emission computed tomography (FDG PET/CT) positivity was observed among patients with GNB than in those with GPB-CIED infection (85.7% vs. 66.7%; P = 0.208). Risk factors for GNB-CIED infection were Charlson Comorbidity Index Score (relative risk reduction, RRR = 1.211; P = 0.011), obesity (RRR = 5.122; P = 0.008), ventricular-pacing ventricular-sensing inhibited-response pacemaker implantation (RRR = 3.027; P = 0.006) and right subclavian vein site of implantation (RRR = 5.014; P = 0.004). At 180-day survival analysis, GNB-CIED infection was associated with increased mortality risk (HR = 1.842; P = 0.067). CONCLUSIONS: Obesity, high number of comorbidities and right subclavian vein implantation site were associated with increased risk of GNB-CIED infection. A prompt therapeutic intervention that may be guided using FDG PET/CT is suggested in patients with GNB-CIED infection, considering the poorer outcome observed in this group.


Assuntos
Infecções Cardiovasculares , Desfibriladores Implantáveis , Infecções por Bactérias Gram-Negativas , Infecções Relacionadas à Prótese , Humanos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/efeitos adversos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/microbiologia , Estudos Retrospectivos , Compostos Radiofarmacêuticos , Fatores de Risco , Infecções por Bactérias Gram-Negativas/epidemiologia , Infecções por Bactérias Gram-Negativas/complicações , Obesidade , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/diagnóstico
4.
Pacing Clin Electrophysiol ; 46(1): 39-43, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35941725

RESUMO

Leadless pacemaker implantation (LPI) has fewer device complications and reduced chance of infection compared to conventional pacemakers. Dextrocardia with situs viscerum inversus (DC+SVI) is a rare condition, which seldom leads to cardiac complications. However, its presence poses a challenge to operators in cardiac procedures. LPI reports in DC patients are scarce. We report a case of LPI in a DC+SVI patient, followed by a brief but comprehensive literature review.


Assuntos
Dextrocardia , Marca-Passo Artificial , Situs Inversus , Humanos , Dextrocardia/complicações , Situs Inversus/complicações , Situs Inversus/terapia
5.
J Cardiovasc Electrophysiol ; 33(10): 2195-2201, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35842805

RESUMO

INTRODUCTION: The prevalence and impact of pulmonary embolism (PE) in patients with lead-related infective endocarditis undergoing transvenous lead extraction (TLE) are unknown. METHODS: Twenty-five consecutive patients with vegetations ≥10 mm at transoesophageal echocardiography were prospectively studied. Contrast-enhanced chest computed tomography (CT) was performed before (pre-TLE) and after (post-TLE) the lead extraction procedure. RESULTS: Pre-TLE CT identified 18 patients (72%) with subclinical PE. The size of vegetations in patients with PE did not differ significantly from those without (median 20.0 mm [interquartile range: 13.0-30.0] vs. 14.0 mm [6.0-18.0], p = 0.116). Complete TLE success was achieved in all patients with 3 (2-3) leads extracted per procedure. There were no postprocedure complications related to the presence of PE and no differences in terms of fluoroscopy time and need for advanced tools. In the group of positive pre-TLE CT, post-TLE scan confirmed the presence of silent PE in 14 patients (78%). There were no patients with new PE formation. Large vegetations (≥20 mm) tended to increase the risk of post-TLE subclinical PE (odds ratio 5.99 [95% confidence interval (CI): 0.93-38.6], p = 0.059). During a median 19.4 months follow-up, no re-infection of the implanted system was reported. Survival rates in patients with and without post-TLE PE were similar (hazard ratio: 1.11 [95% CI: 0.18-6.67], p = 0.909). CONCLUSION: Subclinical PE detected by CT was common in patients undergoing TLE with lead-related infective endocarditis and vegetations but was not associated with the complexity of the procedure or adverse outcomes. TLE procedure seems safe and feasible even in patients with large vegetations.


Assuntos
Desfibriladores Implantáveis , Endocardite Bacteriana , Endocardite , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Embolia Pulmonar , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Endocardite/diagnóstico por imagem , Endocardite/epidemiologia , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/epidemiologia , Humanos , Marca-Passo Artificial/efeitos adversos , Prevalência , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/epidemiologia , Embolia Pulmonar/terapia , Estudos Retrospectivos
6.
J Cardiovasc Electrophysiol ; 33(5): 1034-1040, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35243712

RESUMO

INTRODUCTION: We hypothesized that an accurate assessment of preoperative venography could be useful in predicting transvenous lead extraction (TLE) difficulty. METHODS AND RESULTS: A dedicated preoperative venogram was performed in consecutive patients with cardiac implantable electronic device who underwent TLE. The level of stenosis was classified as without significant stenosis, moderate, severe, and occlusion. The presence of extensive lead-venous wall adherence (≥50 mm) was also assessed. A total of 105 patients (median age: 71 years; 72% male) with a median of 2 (1-2) leads to extract were enrolled. Preoperative venography showed moderate to severe stenosis in 31 (30%), complete occlusion in 15 (14%), and extensive lead-venous wall adherence in 50 (48%) patients. Complete TLE success was achieved in 103 (98%) patients. A total of 55 (52%) were advanced extractions as they required a powered mechanical and/or laser sheath. They were more prevalent in the group with extensive lead-venous wall adherence (72% vs. 34%, p < .001), while no differences were found between patients with and without venous occlusion. In multivariate analysis, the presence of adherence was a predictor of advanced extraction (odds ratio: 2.89 [1.14-7.32], p = .025). The fluoroscopy time was also significantly longer (14.0 [8.2-18.7] vs. 5.1 [2.1-10.0] min, p < .001). The rate of complications did not differ based on the presence of venous lesions. CONCLUSION: Although procedural success and complication rates were similar, patients with extensive lead-venous wall adherence required a longer fluoroscopy time and were three times more likely to need advanced extraction tools. Conversely, the presence of total venous occlusion had no impact on the procedure complexity.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Doenças Vasculares , Idoso , Constrição Patológica , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Feminino , Humanos , Masculino , Flebografia , Estudos Retrospectivos , Resultado do Tratamento
7.
Curr Cardiol Rep ; 23(10): 144, 2021 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-34410527

RESUMO

PURPOSE OF REVIEW: The nitric oxide (NO)-soluble guanylate cyclase (sGC)-cyclic guanosine monophosphate (cGMP) pathway plays an important role in the regulation of cardiovascular function, and it is disrupted in heart failure (HF), resulting in decreased protection against myocardial injury. Impaired NO-sGC-cGMP signaling in HF is secondary to reduced NO bioavailability and altered redox state of sGC, which becomes less responsive to NO. The sGC activator cinaciguat increases cGMP levels by direct NO-independent activation of sGC and may be particularly effective in conditions of increased oxidative stress and endothelial dysfunction, and therefore reduced NO levels, at the expense of a greater risk of hypotension. Conversely, sGC stimulators (riociguat and vericiguat) enhance sGC sensitivity to endogenous NO, thus exerting a more physiological action. RECENT FINDINGS: Clinical trials have suggested the benefit of vericiguat in patients with high-risk HF; in particular, a lower incidence of death from cardiovascular causes or HF hospitalization. Adding vericiguat may be considered in individual patients with HF, and reduced left ventricular ejection fraction (HFrEF) particularly those at higher risk of HF hospitalization.


Assuntos
Insuficiência Cardíaca , Compostos Heterocíclicos com 2 Anéis , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Óxido Nítrico , Pirimidinas , Volume Sistólico , Função Ventricular Esquerda
8.
Monaldi Arch Chest Dis ; 90(1)2020 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-32241096

RESUMO

We hereby report a puzzling case of multiple sclerosis (MS) relapse presenting as Takotsubo syndrome (TTS). Female, 42-years old, who presented herself to the Emergency Room of University Hospital "ASST Spedali Civili" of Brescia, Italy, for a severe headache and a non-ST-segment elevation acute coronary syndrome. Coronary angiogram showed no signs of coronary atherosclerosis. Upon further neurological evaluation, a diagnosis of MS relapse, related to TTS, was made, and treatment was started accordingly. The patient was discharged after 12 days after the admission, free of symptoms, and without signs of neurological and cardiological active disease. A hallmark of TTS is its association with a preceding stressful event. It may also be connected to a wide variety of diseases, including neurological ones, such as stroke, intracranial bleeding, head trauma, migraine, and seizures. However, up to our knowledge, only few cases of MS-induced TTS were previously described. Whether it is plausible to consider TTS as an uncommon extra-neurological manifestation of MS is still debated, however all the evidence points in that direction, considering the central role of catecholamines in TTS pathogenesis. With this case report the authors hope to encourage research on this field and on the intricate topic of brain-heart connections.


Assuntos
Esclerose Múltipla/diagnóstico , Cardiomiopatia de Takotsubo/diagnóstico , Síndrome Coronariana Aguda/etiologia , Adulto , Diagnóstico Diferencial , Feminino , Humanos , Esclerose Múltipla/complicações , Recidiva , Cardiomiopatia de Takotsubo/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...