Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38625833

RESUMO

BACKGROUND: Atrioventricular block (AVB) is a frequent complication in patients undergoing transcatheter aortic valve implantation (TAVI). Right apex ventricular pacing (RVP) represents the standard treatment but may induce cardiomyopathy over the long term. Left bundle branch area pacing (LBBAP) is a promising alternative, minimizing the risk of desynchrony. However, available evidence with LBBAP after TAVI is still low. OBJECTIVE: To assess the feasibility and safety of LBBAP for AVB post-TAVI compared with RVP. METHODS: Consecutive patients developing AVB early after TAVI were enrolled between 1 January 2022 and 31 December 2022 at three high-volume hospitals and received LBBAP or RVP. Data on procedure and at short-term follow-up (at least 3 months) were collected. RESULTS: A total of 38 patients (61% men, mean age 83 ±â€Š6 years) were included; 20 patients (53%) received LBBAP. Procedural success was obtained in all patients according to chosen pacing strategy. Electrical pacing performance at implant and after a mean follow-up of 4.2 ±â€Š2.8 months was clinically equivalent for both pacing modalities. In the LBBAP group, procedural time was longer (70 ±â€Š17 versus 58 ±â€Š15 min in the RVP group, P = 0.02) and paced QRS was shorter (120 ±â€Š19 versus 155 ±â€Š12 ms at implant, P < 0.001; 119 ±â€Š18 versus 157 ±â€Š9 ms at follow-up, P < 0.001). Complication rates did not differ between the two groups. CONCLUSION: In patients with AVB after TAVI, LBBAP is feasible and safe, resulting in a narrow QRS duration, either acutely and during the follow-up, compared with RVP. Further studies are needed to evaluate if LBBAP reduces pacing-induced cardiomyopathy in this clinical setting.

2.
J Clin Med ; 13(8)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38673430

RESUMO

Objectives: Conduction system pacing (CSP) and atrioventricular junction ablation (AVJA) improve the outcomes in patients with symptomatic, refractory atrial fibrillation (AF). In this setting, AVJA can be performed simultaneously with implantation or in a second procedure a few weeks after implantation. Comparison data on these two alternative strategies are lacking. Methods: A prospective, multicentre, observational study enrolled consecutive patients with symptomatic, refractory AF undergoing CSP and AVJA performed in a single procedure or in two separate procedures. Data on the long-term outcomes and healthcare resource utilization were prospectively collected. Results: A total of 147 patients were enrolled: for 105 patients, CSP implantation and AVJA were performed simultaneously (concomitant AVJA); in 42, AVJA was performed in a second procedure, with a mean of 28.8 ± 19.3 days from implantation (delayed AVJA). After a mean follow-up of 12 months, the rate of procedure-related complications was similar in both groups (3.8% vs. 2.4%; p = 0.666). Concomitant AVJA was associated with a lower number of procedure-related hospitalizations per patient (1.0 ± 0.1 vs. 2.0 ± 0.3; p < 0.001) and with a lower number of hospital treatment days per patient (4.7 ± 1.8 vs. 7.4 ± 1.9; p < 0.001). Conclusions: Concomitant AVJA resulted as being as safe as delayed AVJA and was associated with a lower utilization of healthcare resources.

3.
J Cardiovasc Electrophysiol ; 35(5): 942-949, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38462681

RESUMO

INTRODUCTION: Mapping system is useful in ablation of atrioventricular nodal reentry tachycardia (AVNRT) and localization of anatomic variances. Voltage mapping identifies a low voltage area in the Koch triangle called low-voltage-bridge (LVB); propagation mapping identifies the collision point (CP) of atrial wavefront convergence. We conducted a prospective study to evaluate the relationship between LVB and CP with successful site of ablation and identify standard value for LVB. MATERIALS AND METHODS: Three-dimensional (3D) maps of the right atria were constructed from intracardiac recordings using the ablation catheter. Cut-off values on voltage map were adjusted until LVB was observed. On propagation map, atrial wavefronts during sinus rhythm collide in the site representing CP, indicating the area of slow pathway conduction. Ablation site was selected targeting LVB and CP site, confirmed by anatomic position on fluoroscopy and atrioventricular ratio. RESULTS: Twenty-seven consecutive patients were included. LVB and CP were present in all patients. Postprocedural evaluation identified standard cut-off of 0.3-1 mV useful for LVB identification. An overlap between LVB and CP was observed in 23 (85%) patients. Procedure success was achieved in all patient with effective site at first application in 22 (81%) patients. There was a significant correlation between LVB, CP, and the site of effective ablation (p = .001). CONCLUSION: We found correlation between LVB and CP with the site of effective ablation, identifying a voltage range useful for standardized LVB identification. These techniques could be useful to identify ablation site and minimize radiation exposure.


Assuntos
Potenciais de Ação , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Taquicardia por Reentrada no Nó Atrioventricular , Humanos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Masculino , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto , Valor Preditivo dos Testes , Idoso , Nó Atrioventricular/fisiopatologia , Nó Atrioventricular/cirurgia , Fatores de Tempo
4.
Heart Rhythm ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38428448

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is a well-established therapy in patients with reduced left ventricular ejection fraction, heart failure, and left bundle branch block. Left bundle branch area pacing (LBBAP) has recently been shown to be a feasible and effective alternative to BVP. Comparative data on the risk of complications between LBBAP and BVP among patients undergoing CRT are lacking. OBJECTIVE: The aim of this study was to compare the long-term risk of procedure-related complications between LBBAP and BVP in a cohort of patients undergoing CRT. METHODS: This prospective, multicenter, observational study enrolled 668 consecutive patients (mean age 71.2 ± 10.0 years; 52.2% male; 59.4% with New York Heart Association class III-IV heart failure symptoms) with left ventricular ejection fraction 33.4% ± 4.3% who underwent BVP (n = 561) or LBBAP (n = 107) for a class I or II indication for CRT. Propensity score matching for baseline characteristics yielded 93 matched pairs. The rate and nature of intraprocedural and long-term post-procedural complications occurring during follow-up were prospectively collected and compared between the 2 groups. RESULTS: During a mean follow-up of 18 months, procedure-related complications were observed in 16 patients: 12 in BVP (12.9%) and 4 in LBBAP (4.3%) (P = .036). Compared with patients who underwent LBBAP, those who underwent BVP showed a lower complication-free survival (P = .032). In multivariate analysis, BVP resulted an independent predictive factor associated with a higher risk of complications (hazard ratio 3.234; P = .042). Complications related to the coronary sinus lead were most frequently observed in patients who underwent BVP (50.0% of all complications). CONCLUSION: LBBAP was associated with a lower long-term risk of device-related complications compared with BVP in patients with an indication for CRT.

5.
Eur Heart J ; 45(10): 823-833, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38289867

RESUMO

BACKGROUND AND AIMS: An electrical storm (ES) is a clinical emergency with a paucity of established treatment options. Despite initial encouraging reports about the safety and effectiveness of percutaneous stellate ganglion block (PSGB), many questions remained unsettled and evidence from a prospective multicentre study was still lacking. For these purposes, the STAR study was designed. METHODS: This is a multicentre observational study enrolling patients suffering from an ES refractory to standard treatment from 1 July 2017 to 30 June 2023. The primary outcome was the reduction of treated arrhythmic events by at least 50% comparing the 12 h following PSGB with the 12 h before the procedure. STAR operators were specifically trained to both the anterior anatomical and the lateral ultrasound-guided approach. RESULTS: A total of 131 patients from 19 centres were enrolled and underwent 184 PSGBs. Patients were mainly male (83.2%) with a median age of 68 (63.8-69.2) years and a depressed left ventricular ejection fraction (25.0 ± 12.3%). The primary outcome was reached in 92% of patients, and the median reduction of arrhythmic episodes between 12 h before and after PSGB was 100% (interquartile range -100% to -92.3%). Arrhythmic episodes requiring treatment were significantly reduced comparing 12 h before the first PSGB with 12 h after the last procedure [six (3-15.8) vs. 0 (0-1), P < .0001] and comparing 1 h before with 1 h after each procedure [2 (0-6) vs. 0 (0-0), P < .001]. One major complication occurred (0.5%). CONCLUSIONS: The findings of this large, prospective, multicentre study provide evidence in favour of the effectiveness and safety of PSGB for the treatment of refractory ES.


Assuntos
Taquicardia Ventricular , Idoso , Feminino , Humanos , Masculino , Estudos Prospectivos , Gânglio Estrelado , Volume Sistólico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiologia , Resultado do Tratamento , Fibrilação Ventricular/etiologia , Função Ventricular Esquerda , Pessoa de Meia-Idade
6.
J Interv Card Electrophysiol ; 67(2): 341-351, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37599321

RESUMO

BACKGROUND: Left bundle branch area pacing (LBBAP) is an emerging cardiac pacing modality that preserves fast electrical activation of the ventricles and provides very good electrical measures. Little is known on mechanical ventricular activation during this pacing modality. METHODS: We prospectively enrolled patients receiving LBBAP. Electrocardiographic and electrical parameters were evaluated at implantation, < 24 h and 3 months. Transthoracic echocardiography with strain analysis was performed at baseline and after 3 months, when ventricular mechanical activation and synchrony were analyzed by time-to-peak standard deviation (TPSD) of strain curves for both ventricles. Intraventricular left ventricular (LV) dyssynchrony was investigated by LV TPSD and interventricular dyssynchrony by left ventricle-right ventricle TPSD (LV-RV TPSD). RESULTS: We screened 58 patients with permanent pacing indication who attempted LBBAP. Procedural success was obtained in 56 patients (97%). Strain data were available in 50 patients. QRS duration was 124.1 ± 30.7 ms at baseline, while paced QRS duration was 107.7 ± 13.6 ms (p < 0.001). At 3 months after LBBAP, left ventricular ejection fraction (LVEF) increased from 52.9 ± 10.6% at baseline to 56.9 ± 8.4% (p = 0.004) and both intraventricular LV dyssynchrony and interventricular dyssynchrony significantly improved (LV TPSD reduction from 38.2 (13.6-53.9) to 15.1 (8.3-31.5), p < 0.001; LV-RV TPSD from 27.9 (10.2-41.5) to 13.9 (4.3-28.7), p = 0.001). Ameliorations with LBBAP were consistent in all subgroups, irrespective of baseline QRS duration, types of intraventricular conduction abnormalities, and LVEF. CONCLUSIONS: Echocardiographic strain analysis shows that LBBAP determines a fast and synchronous biventricular contraction with a stereotype mechanical activation, regardless of baseline QRS duration, pattern, and LV function.


Assuntos
Estimulação Cardíaca Artificial , Ventrículos do Coração , Humanos , Ventrículos do Coração/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda , Ecocardiografia , Eletrocardiografia , Resultado do Tratamento
7.
Pacing Clin Electrophysiol ; 46(10): 1258-1268, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37665040

RESUMO

BACKGROUND: Conduction system pacing (CSP), including His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP), have been proposed as alternatives to biventricular pacing (BVP) in patients scheduled for ablate and pace (A&P) strategy. The aim of this study was to compare the clinical outcomes, including the rate and nature of device-related complications, between BVP and CSP in a cohort of patients undergoing A&P. METHODS: Prospective, multicenter, observational study, enrolling consecutive patients undergoing A&P. The risk of device-related complications and of heart failure (HF) hospitalization was prospectively assessed. RESULTS: A total of 373 patients (75.3 ± 8.7 years, 53.9% male, 68.9% with NYHA class ≥III) were enrolled: 263 with BVP, 68 with HBP, and 42 with LBBAP. Baseline characteristics of the three groups were similar. Compared to BVP and HBP, LBBAP was associated with the shortest mean procedural and fluoroscopy times and with the lowest acute capture thresholds (all p < .05). At 12-month follow-up LBBAP maintained the lowest capture thresholds and showed the longest estimated residual battery longevity (all p < .05). At 12-months follow-up the three study groups showed a similar risk of device-related complications (5.7%, 4.4%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .650), and of HF hospitalization (2.7%, 1.5%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .850). CONCLUSIONS: In the setting of A&P, CSP is a feasible pacing modality, with a midterm safety profile comparable to BVP. LBBAP offers the advantage of reducing procedural times and obtaining lower and stable capture thresholds, with a positive impact on the device longevity.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Feminino , Estudos Prospectivos , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco , Fontes de Energia Elétrica , Insuficiência Cardíaca/terapia , Fascículo Atrioventricular , Resultado do Tratamento , Eletrocardiografia , Estimulação Cardíaca Artificial
9.
Pacing Clin Electrophysiol ; 46(9): 1092-1098, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37428835

RESUMO

BACKGROUND: Automated threshold measurements (ATM) and output adaptation improved safety and follow-up of cardiac implantable devices (CIED) in the last years. These algorithms were validated for conventional cardiac pacing; however, they were not suitable for permanent His Pacing. Left bundle branch area pacing (LBBAP) is an emerging technique to obtain physiologic cardiac stimulation; we tried to assess if ATM could be applied to this setting. METHODS: Consecutive patients receiving ATM-capable CIED and LBBAP in our hospital were enrolled in this prospective, observational trial; they were evaluated 3 months after implant, comparing pacing thresholds manually assessed and obtained via ATM. Subsequent remote follow-up was carried on when available. RESULTS: Forty-five patients were enrolled. ATM for LBBAP lead provided consistent results in all the patients and was therefore activated; mean value of manually obtained LBBAP capture threshold was 0.66 ± 0.19 V versus ATM of 0.64 ± 0.19 V. TOST analysis showed equivalence of the two measures (p = .66). At subsequent follow-up (mean follow up 7.7 ± 3.2 months), ATM was effective in assessing pacing thresholds and no clinical adverse event was observed. CONCLUSIONS: ATM algorithms proved equivalent to manual testing in determining capture threshold and were reliably employed in patients receiving LBBAP CIED.


Assuntos
Sistema de Condução Cardíaco , Septo Interventricular , Humanos , Projetos Piloto , Estudos Prospectivos , Doença do Sistema de Condução Cardíaco , Algoritmos , Eletrocardiografia , Estimulação Cardíaca Artificial , Fascículo Atrioventricular , Resultado do Tratamento
10.
Front Cardiovasc Med ; 10: 1169037, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37476572

RESUMO

Background: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have the potential to act as a reliable predictor of the durability of the lesions created. Objective: We aimed to collect data on the procedural parameters affecting LI-guided ablation in a large multicenter registry. Methods: A total of 212 consecutive patients enrolled in the CHARISMA registry and undergoing their first pulmonary vein (PV) isolation for paroxysmal and persistent AF were included. Results: In all, 13,891 radiofrequency (RF) applications of ≥3 s duration were assessed. The first-pass PV isolation rate was 93.3%. A total of 80 PV gaps were detected. At successful ablation spots, baseline LI and absolute LI drop were larger than at PV gap spots (161.4 ± 19â€…Ω vs. 153.0 ± 13 Ω, p < 0.0001 for baseline LI; 22.1 ± 9â€…Ω vs. 14.4 ± 5 Ω, p < 0.0001 for LI drop). On the basis of Receiver operating characteristic curve analysis, the ideal LI drop, which predicted successful ablation, was >21â€…Ω at anterior sites and >18â€…Ω at posterior sites. There was a non-linear association between the magnitude of LI drop and contact-force (CF) (r = 0.14, 95% CI: 0.13-0.16, p < 0.0001) whereas both CF and LI drop were inversely related with delivery time (DT) (-0.22, -0.23 to -0.20, p < 0.0001 for CF; -0.27, -0.29 to -0.26, p < 0.0001 for LI drop). Conclusion: An LI drop >21â€…Ω at anterior sites and >18â€…Ω at posterior sites predicts successful ablation. A higher CF was associated with an increased likelihood of ideal LI drop. The combination of good CF and adequate LI drop allows a significant reduction in RF DT. Clinical trial registration: http://clinicaltrials.gov/, identifier: NCT03793998.

11.
J Cardiovasc Electrophysiol ; 34(6): 1441-1451, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37161936

RESUMO

INTRODUCTION: In patients receiving conduction system pacing (CSP), it is not well established how to program the sensed atrioventricular delay (sAVD), with respect to the type of capture obtained (selective, nonselective His-bundle [HB] capture or left bundle branch [LBB] capture). The aim of this study was to acutely assess the effectiveness of an electrophysiology (EP)-guided method for sAVD optimization by comparing it with the echocardiogram-guided optimization. METHODS AND RESULTS: Consecutive patients undergoing HB or LBB pacing were enrolled. The EP-guided sAVD was defined as the sAVD leading to a PR interval of 150 ms on surface electrocardiogram (ECG). In HB pacing patients, EP-guided sAVD was obtained subtracting the time from the onset of the P wave on ECG to the local atrial electrogram (EGM) recorded by the atrial lead (right atrial sensing latency, RASL) and the His-ventricular interval from 150 ms; in LBB pacing patients, subtracting RASL from 150 ms. Transmitral flow assessment by pulsed wave Doppler was used to find the echo-optimized sAVD by a modified iterative method. The discordance between the EP-guided and the echo-optimized sAVD was recorded. RESULTS: Seventy-one patients were enrolled: 12 with selective, 32 nonselective HB capture, and 27 LBB capture. Overall, the rate of concordance between the EP-guided and the echo-optimized sAVD was 71.8%, with no significant differences between the three groups. CONCLUSION: In CSP patients, an optimal sAVD can be programmed, in more than 70% of cases, considering only simple EGM intervals to obtain a physiological PR interval on surface ECG.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/terapia , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco , Fascículo Atrioventricular , Eletrocardiografia/métodos
12.
J Cardiovasc Electrophysiol ; 34(6): 1386-1394, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37194742

RESUMO

INTRODUCTION: Brugada syndrome (BrS) has a dynamic ECG pattern that might be revealed by certain conditions such as fever. We evaluated the incidence and management of ventricular arrhythmias (VAs) related to COVID-19 infection and vaccination among BrS patients carriers of an implantable loop recorder (ILR) or implantable cardioverter-defibrillator (ICD) and followed by remote monitoring. METHODS: This was a multicenter retrospective study. Patients were carriers of devices with remote monitoring follow-up. We recorded VAs 6 months before COVID-19 infection or vaccination, during infection, at each vaccination, and up to 6-month post-COVID-19 or 1 month after the last vaccination. In ICD carriers, we documented any device intervention. RESULTS: We included 326 patients, 202 with an ICD and 124 with an ILR. One hundred and nine patients (33.4%) had COVID-19, 55% of whom developed fever. Hospitalization rate due to COVID-19 infection was 2.76%. After infection, we recorded only two ventricular tachycardias (VTs). After the first, second, and third vaccines, the incidence of non-sustained ventricular tachycardia (NSVT) was 1.5%, 2%, and 1%, respectively. The incidence of VT was 1% after the second dose. Six-month post-COVID-19 healing or 1 month after the last vaccine, we documented NSVT in 3.4%, VT in 0.5%, and ventricular fibrillation in 0.5% of patients. Overall, one patient received anti-tachycardia pacing and one a shock. ILR carriers had no VAs. No differences were found in VT before and after infection and before and after each vaccination. CONCLUSIONS: From this large multicenter study conducted in BrS patients, followed by remote monitoring, the overall incidence of sustained VAs after COVID-19 infection and vaccination is relatively low.


Assuntos
Síndrome de Brugada , COVID-19 , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/epidemiologia , Síndrome de Brugada/terapia , Estudos Retrospectivos , Incidência , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/prevenção & controle , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/terapia , Sistema de Registros , Vacinação , Seguimentos
13.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36974970

RESUMO

AIMS: In patients with prolonged atrioventricular (AV) conduction and pacemaker (PM) indication due to sinus node disease (SND) or intermittent AV-block who do not need continuous ventricular pacing (VP), it may be difficult to determine which strategy to adopt. Currently, the standard of care is to minimize unnecessary VP by specific VP avoidance (VPA) algorithms. The superiority of this strategy over standard DDD or DDD rate-responsive (DDD/DDDR) in improving clinical outcomes is controversial, probably owing to the prolongation of the atrialventricular conduction (PR interval) caused by the algorithms. Conduction system pacing (CSP) may offer the most physiological-VP approach, providing appropriate AV conduction and preventing pacing-induced dyssynchrony. METHODS AND RESULTS: PhysioVP-AF is a prospective, controlled, randomized, single-blind trial designed to determine whether atrial-synchronized conduction system pacing (DDD-CSP) is superior to standard DDD-VPA pacing in terms of 3-year reduction of persistent-AF occurrence. Cardiovascular hospitalization, quality-of-life, and safety will be evaluated. Patients with indication for permanent DDD pacing for SND or intermittent AV-block and prolonged AV conduction (PR interval > 180 ms) will be randomized (1:1 ratio) to DDD-VPA (VPA-algorithms ON, septal/apex position) or to DDD-CSP (His bundle or left bundle branch area pacing, AV-delay setting to control PR interval, VPA-algorithms OFF). Approximately 400 patients will be randomized in 24 months in 13 Italian centres. CONCLUSION: The PhysioVP-AF study will provide an essential contribution to patient management with prolonged AV conduction and PM indication for sinus nodal disease or paroxysmal 2nd-degree AV-block by determining whether CSP combined with a controlled PR interval is superior to standard management that minimizes unnecessary VP in terms of reducing clinical outcomes.


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Marca-Passo Artificial , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estudos Prospectivos , Método Simples-Cego , Síndrome do Nó Sinusal/complicações , Síndrome do Nó Sinusal/diagnóstico , Síndrome do Nó Sinusal/terapia
14.
Heart Rhythm ; 20(7): 984-991, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36906165

RESUMO

BACKGROUND: Conduction system pacing (CSP) using His bundle pacing (HBP) or left bundle branch area pacing (LBBAP) has emerged as an alternative to right ventricular pacing (RVP). Comparative data on the risk of complications between CSP and RVP are lacking. OBJECTIVE: This prospective, multicenter, observational study aimed to compare the long-term risk of device-related complications between CSP and RVP. METHODS: A total of 1029 consecutive patients undergoing pacemaker implantation with CSP (including HBP and LBBAP) or RVP were enrolled. Propensity score matching for baseline characteristics yielded 201 matched pairs. The rate and nature of device-related complications occurring during follow-up were prospectively collected and compared between the 2 groups. RESULTS: During a mean follow-up duration of 18 months, device-related complications were observed in 19 patients: 7 in RVP (3.5%) and 12 in CSP (6.0%) (P = .240). On dividing the matched cohort into 3 groups with similar baseline characteristics according to pacing modality (RVP, n = 201; HBP, n = 128; LBBAP, n = 73), patients with HBP showed a significantly higher rate of device-related complications than did patients with RVP (8.6% vs 3.5%; P = .047) and patients with LBBAP (8.6% vs 1.3%; P = .034). Patients with LBBAP showed a rate of device-related complications similar to that of patients with RVP (1.3% vs 3.5%; P = .358). Most of the complications observed in patients with HBP (63.6%) were lead related. CONCLUSION: Globally, CSP was associated with a risk of complications similar to that of RVP. Considering HBP and LBBAP separately, HBP showed a significantly higher risk of complications than did both RVP and LBBAP whereas LBBAP showed a risk of complications similar to that of RVP.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Estudos Prospectivos , Pontuação de Propensão , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Doença do Sistema de Condução Cardíaco , Resultado do Tratamento
15.
Expert Rev Med Devices ; 20(1): 45-54, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36631432

RESUMO

BACKGROUND: Implantable loop recorder (ILR) is still underutilized in clinical practice, especially in the setting of elderly patients with recurrent, traumatic, unexplained syncope. Data on the actual risk of traumatic syncopal recurrence during ILR monitoring in this specific patient setting are lacking. RESEARCH DESIGN AND METHODS: Prospective, multicentre registry enrolling consecutive patients undergoing ILR insertion for unexplained, recurrent, traumatic syncope. In a proportion of enrolled patients, remote monitoring (RM) was used for device follow-up. The risk of traumatic and non-traumatic syncopal recurrences during ILR observation were prospectively assessed. RESULTS: A total of 483 consecutive patients (68±14 years, 59% male) were enrolled. During a median follow-up of 18 months, a final diagnosis was reached in 270 patients (55.9%). The risk of syncopal and traumatic syncopal recurrence was of 26.5 and 9.3%, respectively. RM significantly reduced the time to diagnosis (19.7±10.3 vs. 22.1±10.8 months; p=0.015) and was associated with a significant reduction in the risk of syncope recurrence of 48% (p<0.001), and of traumatic syncope recurrence of 49% (p=0.018). CONCLUSIONS: ILR monitoring is effective and safe in patients with unexplained, recurrent, traumatic syncope. RM reduces the time to diagnosis and significantly reduces the risk of traumatic and non-traumatic syncopal relapses.


Assuntos
Eletrocardiografia Ambulatorial , Síncope , Humanos , Masculino , Idoso , Feminino , Estudos Prospectivos , Eletrodos Implantados , Síncope/diagnóstico , Diagnóstico Diferencial
17.
Eur Heart J Case Rep ; 6(11): ytac436, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36405535

RESUMO

Background: Coronary sinus is the target of an increasing number of percutaneous interventional procedures. Thus, in some patients, conventional cardiac resynchronization therapy (CRT) may not be feasible or preferable, and 'alternative' CRT approaches should be applied. Case summary: We present the case of a successful CRT via direct left bundle branch permanent pacing (LBBP) in a patient with relative contraindication to conventional CRT because of previous percutaneous indirect mitral annuloplasty. Discussion: LBBP is emerging as a promising technique for physiological cardiac pacing and CRT. It may represent the technique of choice when coronary sinus is not viable for the implant of a conventional left ventricular catheter.

18.
J Cardiovasc Electrophysiol ; 33(11): 2288-2296, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35930617

RESUMO

INTRODUCTION: In patients with symptomatic permanent atrial fibrillation (PEAF) and narrow QRS, atrio-ventricular junction ablation (AVJA) plus cardiac resynchronization therapy (CRT) is superior to medical therapy in reducing heart failure (HF) hospitalization and all-cause mortality. To compare the mortality of a population of patients with HF, reduced EF (rEF), and PEAF treated with AVJA plus CRT with that of a contemporary cohort of patients in sinus rhythm (SR) with similar baseline characteristics. METHODS AND RESULTS: In this prospective, multicentre, observational study, all-cause mortality in a group of consecutive patients undergoing AVJA and implantable cardioverter-defibrillator (ICD) combined with CRT implantation for HFrEF, narrow QRS, and PEAF with uncontrolled ventricular rate was compared with that of a contemporary cohort of patients in SR undergoing ICD implantation (not combined with CRT) for HFrEF and narrow QRS. Individual 1:1 propensity matching of baseline characteristics was performed. A total of 824 patients were enrolled. Propensity matching yielded 107 matched pairs. After a median follow-up of 52 months, all-cause mortality was similar in patients treated with AVJA plus CRT and in the control group (p = .434). In AVJA plus CRT patients, mortality was significantly lower than in control group patients with a history of paroxysmal/persistent AF (n = 45, p = .020), and similar to that of patients without a history of AF (n = 62, p = .459). CONCLUSIONS: After adjustment for patient characteristics, the long-term prognosis of patients with HFrEF, narrow QRS, and PEAF who underwent AVJA plus CRT was similar to that of a population of patients in SR with similar characteristics.


Assuntos
Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/terapia
19.
Heart Rhythm ; 19(10): 1696-1703, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35643299

RESUMO

BACKGROUND: In patients with unexplained syncope and bifascicular block (BFB), syncope may be caused by intermittent atrioventricular (AV) block. When a correlation between syncope and bradyarrhythmia is not documented in these patients, 2 alternative management strategies can be adopted: (1) empiric pacemaker (PM) implantation or (2) long-term continuous electrocardiographic monitoring by implantable loop recorder (ILR). OBJECTIVE: The purpose of this study was to compare the risk of syncope recurrence associated with empiric PM implantation or ILR monitoring. METHODS: A prospective, multicenter, observational study enrolled consecutive patients with unexplained, recurrent, traumatic syncope and BFB who underwent ILR monitoring or empiric PM implantation. The risk and causes of syncope recurrence were assessed and compared between the 2 groups. Individual 1:1 propensity matching of baseline characteristics was performed. RESULTS: A total of 309 consecutive patients (age 77.2 ± 12.2 years; 60.8% male) were enrolled. Propensity matching yielded 89 matched pairs. After median follow-up of 33 months, empiric PM implantation was associated with a significantly lower risk of syncope recurrence than ILR monitoring (19.1 vs 46.1%; P <.001). A total of 35 patients (39.3%) who underwent ILR monitoring developed bradyarrhythmias (68.6% paroxysmal AV block) requiring PM implantation during follow-up. Excluding bradyarrhythmic syncope, the most frequent causes of syncope recurrence in both study groups were reflex syncope and orthostatic hypotension. CONCLUSION: In patients with unexplained, recurrent, traumatic syncope and BFB, empiric PM implantation significantly reduced the risk of syncope recurrence in comparison with ILR monitoring. A high rate of patients who underwent ILR monitoring developed bradyarrhythmias requiring PM implantation.


Assuntos
Bradicardia , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Bradicardia/diagnóstico , Bradicardia/etiologia , Bradicardia/terapia , Bloqueio de Ramo/complicações , Eletrocardiografia Ambulatorial/métodos , Feminino , Humanos , Masculino , Marca-Passo Artificial/efeitos adversos , Estudos Prospectivos , Síncope/diagnóstico , Síncope/etiologia
20.
J Clin Med ; 11(4)2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35207259

RESUMO

There are no data on procedure-related bleeding outcome with non-vitamin K antagonist anticoagulants (NOACs) versus vitamin K antagonist anticoagulants (VKAs) in patients with atrial fibrillation (AF) undergoing cardiac implantable electronic device (CIED) intervention. Our aim was to evaluate whether NOACs have a safety benefit even in terms of fewer hemorrhagic complications at the site of CIED implant. Consecutive AF patients receiving NOACs or VKAs at the time of CIED procedure were included in this observational, retrospective, and monocentric investigation. Primary endpoint was the incidence of post-intervention pocket hematoma. A total of 311 patients were enrolled, 146 on NOACs, and 165 on VKAs. The incidence of pocket hematoma was 3.4% in the NOAC versus 13.3% in the VKA group (p = 0.002). Primary outcome-free survival at 30-days was 96.6% in patients on NOACs and 86.0% in those on VKAs (p = 0.019). Multivariate analysis, adjusted by propensity-score calculation of inverse-probability-weighting, showed a significantly lower occurrence of pocket hematoma in patients receiving NOACs versus VKAs (HR 0.35, 95% CI 0.13-0.96, p = 0.042). Such NOACs benefit was confirmed versus patients on VKAs without peri-procedural bridging with low-molecular-weight heparin (HR 0.34, 95% CI 0.11-0.99, p = 0.048). The incidence of pocket infection, surgical pocket evacuation, ischemic events, and major bleeding complications at 30 days (secondary endpoints) was similar in the two groups. In conclusion, our data suggest that, among patients with AF undergoing implantable cardiac defibrillator or pacemaker intervention, the use of NOACs versus VKAs may be associated with significant reduction of post-procedural pocket hematoma, regardless of bridging with low-molecular-weight heparin in the VKA group. These results are hypothesis generating and need to be confirmed in a specific randomized study.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...