Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 284
Filtrar
1.
Forensic Sci Int ; 359: 112001, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38714107

RESUMO

BACKGROUND: Cardiac implantable electronic devices (CIED) are a heterogeneous group of medical devices with increasingly sophisticated diagnostic capabilities, which could be exploited in forensic investigations. However, current guidelines are lacking clear recommendations on the topic. The first aim of this systematic review is to provide an updated assessment of the role of postmortem CIED interrogation, and to give practical recommendations, which can be used in daily practice. Secondly, the authors aim to determine the rates of postmortem CIED interrogation and autopsy investigations, the type of final rhythm detected close to death (with a focus on the significance of documented arrhythmias), as well as the role of postmortem CIED interrogation in the determination of final cause/time of death, and any potentially fatal device malfunctions. METHODS: A systematic search in MEDLINE and Scopus aiming to identify reports concerning postmortem human CIED interrogation was performed, including a systematic screening of reference lists. Case reports, letters to the editors, commentaries, review articles or guidelines were excluded, along with studies related to cardiac devices other than CIED. All data were pooled and analyzed using fixed-effects meta-analysis models, and the I2 statistic was used to assess heterogeneity. RESULTS: A total of 25 articles were included in the systematic review, enrolling 3194 decedent CIED carriers. Ten studies (40%) had a 100% autopsy rate, whereas in further 6 studies autopsy findings were variably reported; CIED interrogation was available from 22 studies (88%), and it was never performed prior to autopsy. The overall rate of successful postmortem CIED interrogation was 89%, with high heterogeneity among studies, mainly due to device deactivation/battery discharge. Twenty-four percent of CIED carriers experienced sudden cardiac death (SCD), whereas non-sudden cardiac and non-cardiac death (NSCD, NCD) were reported in 37% and 30% of decedents, respectively. Ventricular tachyarrhythmias were recorded in 34% of overall successfully interrogated CIED, and in 62% of decedents who experienced a SCD; of all ventricular tachyarrhythmias recorded, 40% was found in NSCD or NCD. A clear interpretation of the etiological role of recorded arrhythmias in the causation of death required integration with autopsy findings. Overall, potentially fatal device malfunctions were detected in 12% of cases. CONCLUSIONS: Postmortem CIED interrogation is a valuable tool for the determination of the cause of death, and may complement autopsy. Forensic pathologists need to know the potential utility, pitfalls, and limitations of this diagnostic examination to make this tool as much reliable as possible.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Marca-Passo Artificial/efeitos adversos , Arritmias Cardíacas , Falha de Equipamento
2.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584394

RESUMO

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
4.
J Clin Med ; 13(7)2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38610635

RESUMO

There are no investigations about the outcomes of idiopathic PVC catheter ablation (CA) in athletes compared to the sedentary population. We conducted a prospective single-centre observational study. The primary and secondary procedural outcomes were the post-ablation reduction of premature ventricular contractions (PVCs) in an athletes vs. non-athletes group and in agonist vs. leisure-time athletes. The third was the evaluation of the resumption of physical activity and the improvement of symptoms in agonist and leisure-time athletes. From January 2020 to October 2022 we enrolled 79 patients with RVOT/LVOT/fascicular PVC presumed origin. The median percentage of decrease between the pre-procedure and post-procedure Holter monitoring in the non-athletes group was 96 (IQR 68-98) and 98 in the athletes group (IQR 92-99) (p = 0.08). Considering the athletes, the median percentage of decrease in the number of PVCs was 98 (IQR 93-99) and 98 (IQR 87-99), respectively, in leisure-time and agonistic athletes (p = 0.42). Sixteen (70%) leisure time and seventeen (90%) agonist athletes (p = 0.24) have resumed physical activity 3 months after PVC CA; among agonistic athletes, 59% have resumed competitive physical activity. Many leisure-time (88%) and agonist (70%) athletes experienced an improvement in symptoms after ablation. PVC CA was effective and safe in both groups, reducing symptoms and allowing a quick and safe return to sports activities in athletes.

5.
Eur Heart J Open ; 4(2): oeae023, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38645408

RESUMO

Aims: Albeit often asymptomatic, heart involvement in systemic sclerosis (SSc) represents a negative prognostic factor, accounting for nearly one-fourth of all deaths. Global longitudinal strain (GLS) is accurate in detecting heart involvement in patients with SSc and no overt cardiac disease and allows early detection and longitudinal monitoring, but its association with clinical endpoints has not been tested so far. The primary outcome was the association between left and right GLS and mortality for all causes. The secondary outcome was the association between left and right GLS and hospitalizations. Methods and results: A prospective longitudinal study enrolling all consecutive patients with SSc without structural heart disease or previous cardiovascular event.A total of 164 patients were enrolled, of whom 19 (11.5%) died during follow-up and 48 (29.3%) were hospitalized. Both left (LV) and right ventricle (RV) GLS at enrolment were independently associated with an increased risk of death for all causes and hospitalizations. Patients with biventricular GLS impairment, respectively, had a 4.2-, 4.9-, and 13.9-fold increased risk of death when compared with patients with only LV, only RV, or no impairment (P < 0.001). The incidence of hospitalization in patients with biventricular GLS impairment was nearly four times higher when compared with patients with only LV or only RV impairment, and nine times higher when compared with normal biventricular GLS (P < 0.001). Conclusion: Biventricular GLS is associated with an increased risk of death and hospitalization in patients with SSc during a median of 3-year follow-up, acting as a reliable and accurate prognostic tool in everyday practice.

6.
Medicina (Kaunas) ; 60(4)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38674168

RESUMO

The application of cardiac magnetic resonance (CMR) imaging in clinical practice has grown due to technological advancements and expanded clinical indications, highlighting its superior capabilities when compared to echocardiography for the assessment of myocardial tissue. Similarly, the utilization of implantable cardiac electronic devices (CIEDs) has significantly increased in cardiac arrhythmia management, and the requirements of CMR examinations in patients with CIEDs has become more common. However, this type of exam often presents challenges due to safety concerns and image artifacts. Until a few years ago, the presence of CIED was considered an absolute contraindication to CMR. To address these challenges, various technical improvements in CIED technology, like the reduction of the ferromagnetic components, and in CMR examinations, such as the introduction of new sequences, have been developed. Moreover, a rigorous protocol involving multidisciplinary collaboration is recommended for safe CMR examinations in patients with CIEDs, emphasizing risk assessment, careful monitoring during CMR, and post-scan device evaluation. Alternative methods to CMR, such as computed tomography coronary angiography with tissue characterization techniques like dual-energy and photon-counting, offer alternative potential solutions, although their diagnostic accuracy and availability do limit their use. Despite technological advancements, close collaboration and specialized staff training remain crucial for obtaining safe diagnostic CMR images in patients with CIEDs, thus justifying the presence of specialized centers that are equipped to handle these type of exams.


Assuntos
Desfibriladores Implantáveis , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/normas , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/instrumentação , Arritmias Cardíacas/diagnóstico por imagem
7.
Medicina (Kaunas) ; 60(4)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38674259

RESUMO

Background and Objectives: Cardiac magnetic resonance (CMR) imaging has become an essential instrument in the study of cardiomyopathies; it has recently been integrated into the diagnostic workflow for cardiac amyloidosis (CA) with remarkable results. An additional emerging role is the stratification of the arrhythmogenic risk by scar analysis and the possibility of merging these data with electro-anatomical maps. This is made possible by using a software (ADAS 3D, Galgo Medical, Barcelona, Spain) able to provide 3D heart models by detecting fibrosis along the whole thickness of the myocardial walls. Little is known regarding the applications of this software in the wide spectrum of cardiomyopathies and the potential benefits have yet to be discovered. In this study, we tried to apply the ADAS 3D in the context of CA. Materials and Methods: This study was a retrospectively analysis of consecutive CMR imaging of patients affected by CA that were treated in our center (Marche University Hospital). Wherever possible, the data were processed with the ADAS 3D software and analyzed for a correlation between the morphometric parameters and follow-up events. The outcome was a composite of all-cause mortality, unplanned cardiovascular hospitalizations, sustained ventricular arrhythmias (VAs), permanent reduction in left ventricular ejection fraction, and pacemaker implantation. The secondary outcomes were the need for a pacemaker implantation and sustained VAs. Results: A total of 14 patients were deemed eligible for the software analysis: 8 patients with wild type transthyretin CA, 5 with light chain CA, and 1 with transthyretin hereditary CA. The vast majority of imaging features was not related to the composite outcome, but atrial wall thickening displayed a significant association with both the primary (p = 0.003) and the secondary outcome of pacemaker implantation (p = 0.003). The software was able to differentiate between core zones and border zones of scars, with the latter being the most extensively represented in all patients. Interestingly, in a huge percentage of CMR images, the software identified the highest degree of core zone fibrosis among the epicardial layers and, in those patients, we found a higher incidence of the primary outcome, without reaching statistical significance (p = 0.18). Channels were found in the scar zones in a substantial percentage of patients without a clear correlation with follow-up events. Conclusions: CMR imaging plays a pivotal role in cardiovascular diagnostics. Our analysis shows the feasibility and applicability of such instrument for all types of CA. We could not only differentiate between different layers of scars, but we were also able to identify the presence of fibrosis channels among the different scar zones. None of the data derived from the ADAS 3D software seemed to be related to cardiac events in the follow-up, but this might be imputable to the restricted number of patients enrolled in the study.


Assuntos
Amiloidose , Cardiomiopatias , Cicatriz , Imageamento por Ressonância Magnética , Humanos , Masculino , Projetos Piloto , Feminino , Cardiomiopatias/diagnóstico por imagem , Amiloidose/diagnóstico por imagem , Amiloidose/complicações , Idoso , Cicatriz/diagnóstico por imagem , Estudos Retrospectivos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Software
8.
J Clin Med ; 13(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38610866

RESUMO

Background: The management of cardiogenic shock (CS) after ACS has evolved over time, and the development of a multidisciplinary team-based approach has been shown to improve outcomes, although mortality remains high. Methods: All consecutive patients with ACS-CS admitted at our CICU from March 2012 to July 2021 were included in this single-center retrospective study. In 2019, we established a "shock team" consisting of a cardiac intensivist, an interventional cardiologist, an anesthetist, and a cardiac surgeon. The primary outcome was in-hospital mortality. Results: We included 167 patients [males 67%; age 71 (61-80) years] with ischemic CS. The proportion of SCAI shock stages from A to E were 3.6%, 6.6%, 69.4%, 9.6%, and 10.8%, respectively, with a mean baseline serum lactate of 5.2 (3.1-8.8) mmol/L. Sixty-six percent of patients had severe LV dysfunction, and 76.1% needed ≥ 1 inotropic drug. Mechanical cardiac support (MCS) was pursued in 91.1% [65% IABP, 23% Impella CP, 4% VA-ECMO]. From March 2012 to July 2021, we observed a significative temporal trend in mortality reduction from 57% to 29% (OR = 0.90, p = 0.0015). Over time, CS management has changed, with a significant increase in Impella catheter use (p = 0.0005) and a greater use of dobutamine and levosimendan (p = 0.015 and p = 0.0001) as inotropic support. In-hospital mortality varied across SCAI shock stages, and the SCAI E profile was associated with a poor prognosis regardless of patient age (OR 28.50, p = 0.039). Conclusions: The temporal trend mortality reduction in CS patients is multifactorial, and it could be explained by the multidisciplinary care developed over the years.

9.
J Clin Med ; 13(5)2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38592178

RESUMO

Although mitral valve prolapse (MVP) is the most prevalent valvular abnormality in Western countries and generally carries a good prognosis, a small subset of patients is exposed to a significant risk of malignant ventricular arrhythmias (VAs) and sudden cardiac death (SCD), the so-called arrhythmic MVP (AMVP) syndrome. Recent work has emphasized phenotypical risk features of severe AMVP and clarified its pathophysiology. However, the appropriate assessment and risk stratification of patients with suspected AMVP remains a clinical conundrum, with the possibility of both overestimating and underestimating the risk of malignant VAs, with the inappropriate use of advanced imaging and invasive electrophysiology study on one hand, and the catastrophic occurrence of SCD on the other. Furthermore, the sports eligibility assessment of athletes with AMVP remains ill defined, especially in the grey zone of intermediate arrhythmic risk. The definition, epidemiology, pathophysiology, risk stratification, and treatment of AMVP are covered in the present review. Considering recent guidelines and expert consensus statements, we propose a comprehensive pathway to facilitate appropriate counseling concerning the practice of competitive/leisure-time sports, envisioning shared decision making and the multidisciplinary "sports heart team" evaluation of borderline cases. Our final aim is to encourage an active lifestyle without compromising patients' safety.

11.
J Clin Med ; 13(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38541971

RESUMO

Ventricular tachycardias (VTs) and electrical storms (ES) are life-threatening conditions mostly seen in the setting of structural heart disease (SHD). Traditional management strategies, predominantly centered around pharmacological interventions with antiarrhythmic drugs, have demonstrated limited efficacy in these cases, whereas catheter ablation is related with more favorable outcomes. However, patients with hemodynamically unstable, recurrent VT or ES may present cardiogenic shock (CS) that precludes the procedure, and catheter ablation in patients with SHD portends a multifactorial intrinsic risk of acute hemodynamic decompensation (AHD), that is associated with increased mortality. In this setting, the use of mechanical circulatory support (MCS) systems allow the maintenance of end-organ perfusion and cardiac output, improving coronary flow and myocardial mechanics, and minimizing the effect of cardiac stunning after multiple VT inductions or cardioversion. Although ablation success and VT recurrence are not influenced by hemodynamic support devices, MCS promotes diuresis and reduces the incidence of post-procedural kidney injury. In addition, MCS has a role in post-procedural mortality reduction at long-term follow-up. The current review aims to provide a deep overview of the rationale and modality of MCS in patients with refractory arrhythmias and/or undergoing VT catheter ablation, underlining the importance of patient selection and timing for MCS and summarizing reported clinical experiences in this field.

12.
Heart Rhythm ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38428448

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is a well-established therapy in patients with reduced left ventricular ejection fraction, heart failure, and left bundle branch block. Left bundle branch area pacing (LBBAP) has recently been shown to be a feasible and effective alternative to BVP. Comparative data on the risk of complications between LBBAP and BVP among patients undergoing CRT are lacking. OBJECTIVE: The aim of this study was to compare the long-term risk of procedure-related complications between LBBAP and BVP in a cohort of patients undergoing CRT. METHODS: This prospective, multicenter, observational study enrolled 668 consecutive patients (mean age 71.2 ± 10.0 years; 52.2% male; 59.4% with New York Heart Association class III-IV heart failure symptoms) with left ventricular ejection fraction 33.4% ± 4.3% who underwent BVP (n = 561) or LBBAP (n = 107) for a class I or II indication for CRT. Propensity score matching for baseline characteristics yielded 93 matched pairs. The rate and nature of intraprocedural and long-term post-procedural complications occurring during follow-up were prospectively collected and compared between the 2 groups. RESULTS: During a mean follow-up of 18 months, procedure-related complications were observed in 16 patients: 12 in BVP (12.9%) and 4 in LBBAP (4.3%) (P = .036). Compared with patients who underwent LBBAP, those who underwent BVP showed a lower complication-free survival (P = .032). In multivariate analysis, BVP resulted an independent predictive factor associated with a higher risk of complications (hazard ratio 3.234; P = .042). Complications related to the coronary sinus lead were most frequently observed in patients who underwent BVP (50.0% of all complications). CONCLUSION: LBBAP was associated with a lower long-term risk of device-related complications compared with BVP in patients with an indication for CRT.

13.
JACC Clin Electrophysiol ; 10(3): 487-498, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38206263

RESUMO

BACKGROUND: Desmoplakin (DSP) pathogenic/likely pathogenic (P/LP) variants are associated with malignant phenotypes of arrhythmogenic cardiomyopathy (DSP-ACM). Reports of outcomes after ventricular tachycardia (VT) ablation in DSP-ACM are scarce. OBJECTIVES: In this study, the authors sought to report on long-term outcomes of VT ablation in DSP-ACM. METHODS: Patients with P/LP DSP variants at 9 institutions undergoing VT ablation were included. Demographic, clinical, and instrumental data as well as all ventricular arrhythmia (VA) events were collected. Sustained VAs after the index procedure were the primary outcome. A per-patient before and after ablation comparison of rates of VA episodes per year was performed as well. RESULTS: Twenty-four DSP-ACM patients (39.3 ± 12.1 years of age, 62.5% male, median 6,116 [Q1-Q3: 3,362-7,760] premature ventricular complexes [PVCs] per 24 hours, median 4 [Q1-Q3: 2-11] previous VA episodes per patient at ablation) were included. Index procedure was most commonly endocardial/epicardial (19/24) The endocardium of the right ventricle (RV), the left ventricle (LV), or both ventricles were mapped in 8 (33.3%), 9 (37.5%), and 7 (29.2%) cases, respectively. Low voltage potentials were found in 10 of 15 patients in the RV and 11 of 16 in the LV. Endocardial ablation was performed in 18 patients (75.0%). Epicardial mapping in 19 patients (79.2%) identified low voltage potentials in 17, and 16 received epicardial ablation. Over the following 2.9 years (Q1-Q3: 1.8-5.5 years), 13 patients (54.2%) experienced VA recurrences. A significant reduction in per-patient event/year before and after ablation was observed (1.4 [Q1-Q3: 0.5-2.4] to 0.1 [Q1-Q3: 0.0-0.4]; P = 0.009). Two patients needed heart transplantation, and 4 died (3 of heart failure and 1 noncardiac death). CONCLUSIONS: VT ablation in DSP-ACM is effective in reducing the VA burden of the disease, but recurrences are common. Most VT circuits are epicardial, with both LV and RV low voltage abnormalities. Heart failure complicates clinical course and is an important cause of mortality.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Ablação por Cateter , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Desmoplaquinas , Resultado do Tratamento , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/cirurgia , Cardiomiopatias/etiologia , Ablação por Cateter/métodos , Insuficiência Cardíaca/etiologia
14.
Eur Heart J ; 45(7): 538-548, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38195003

RESUMO

BACKGROUND AND AIMS: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. METHODS: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. RESULTS: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. CONCLUSIONS: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/epidemiologia , Displasia Arritmogênica Ventricular Direita/terapia , Estudos Retrospectivos , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Fatores de Risco , América do Norte/epidemiologia , Europa (Continente)/epidemiologia
16.
JACC Clin Electrophysiol ; 10(3): 477-486, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38069973

RESUMO

BACKGROUND: Studies have reported development of pulmonary hypertension (PH) secondary to reduced LA compliance following AF ablation. OBJECTIVES: This study aimed to compare the risk of worsening of baseline PH between non-paroxysmal AF patients undergoing pulsed-field ablation (PFA) and standard radiofrequency ablation (RFA). METHODS: This multicenter study included 28 nonparoxysmal AF patients with PH undergoing a PFA-based ablation procedure after >1 failed RFA. A cohort of 28 AF patients with PH, scheduled for repeat RFA, 1:1 propensity-score matched using a multivariable logistic model, were used as the comparator group. Right heart catheterization and echocardiography were performed before and after the procedure to assess the pulmonary artery pressure (PAP). PH was defined as resting mean PAP of >20 mm Hg. RESULTS: The baseline characteristics of the PFA and propensity-matched RFA groups were comparable. The mean PAP assessments at baseline, follow-up, and change from baseline were analyzed. The groups had comparable baseline mean pulmonary artery pressures (mPAP) (P = 0.177). After adjustment for baseline mPAP in an analysis of covariance model, the least-squares means change at 3 months after ablation was -1.71 ± 1.03 mm Hg and 19.67 ± 1.03 mm Hg in PFA and RFA, respectively (P <0.001). CONCLUSIONS: In this propensity-matched population, no worsening of mPAP was detected following pulsed-field ablation in patients with pre-existing PH undergoing a repeat procedure for recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Hipertensão Pulmonar , Ablação por Radiofrequência , Humanos , Fibrilação Atrial/cirurgia , Hipertensão Pulmonar/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Ablação por Radiofrequência/efeitos adversos , Cateterismo Cardíaco
17.
Clin Res Cardiol ; 113(5): 706-715, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37582977

RESUMO

INTRODUCTION: The aim of the present study was to evaluate the prevalence and prognosis of structural heart disease (SHD) among competitive athletes with negative T waves without pathological findings at transthoracic echocardiogram. METHODS: From a prospective register of 450 athletes consecutively evaluated during a second-level cardiological examination, we retrospectively identified all subjects with the following inclusion criteria: (1) not previously known cardiovascular disease; (2) negative T waves in leads other than V1-V2; (3) normal transthoracic echocardiogram. Patients underwent cardiac MRI and CT. The primary endpoint was the diagnosis of definite SHD after multimodality imaging evaluation. A follow-up was collected for a combined end-point of sudden death, resuscitated sudden cardiac death and hospitalization for any cardiovascular causes. RESULTS: A total of 55 competitive athletes were finally enrolled (50 males, 90%) with a mean age of 27.5 ± 14.1 years. Among the population enrolled 16 (29.1%) athletes had a final diagnosis of SHD. At multivariate analysis, only deep negative T waves remained statistically significant [OR (95% CI) 7.81 (1.24-49.08), p = 0.0285]. Contemporary identification of deep negative T waves and complex arrhythmias in the same patients appeared to have an incremental diagnostic value. No events were collected at 49.3 ± 12.3 months of follow-up. CONCLUSIONS: In a cohort of athletes with negative T waves at ECG, cardiac MRI (and selected use of cardiac CT) enabled the identification of 16 (29.1%) subjects with SHD despite normal transthoracic echocardiography. Deep negative T waves and complex ventricular arrhythmias were the only clinical characteristic associated with SHD diagnosis.


Assuntos
Eletrocardiografia , Cardiopatias , Masculino , Humanos , Adolescente , Adulto Jovem , Adulto , Estudos Retrospectivos , Prevalência , Cardiopatias/diagnóstico , Arritmias Cardíacas , Morte Súbita Cardíaca/etiologia , Atletas , Ecocardiografia/métodos , Prognóstico
18.
J Interv Card Electrophysiol ; 67(3): 549-557, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37584862

RESUMO

BACKGROUND: The clinical performance of high-power, short-duration (HPSD) pulmonary vein isolation (PVI) with the novel flexible tip TactiFlex™ (TFSE) catheter, as compared to standard-power, long-duration (SPLD) PVI using the TactiCath™ (TCSE) catheter among patients undergoing catheter ablation (CA) of atrial fibrillation (AF) is currently unknown. METHODS: We conducted a prospective, observational, single-centre study including 40 consecutive patients undergoing PVI for paroxysmal/persistent AF, using HPSD ablation with the novel TFSE catheter (HPSD/TFSE group). Based on propensity score-matching, forty patients undergoing SPLD PVI with the TCSE catheter were identified (SPLD/TCSE group). In the HPSD/TFSE group, RF lesions were performed by delivering 40-50 W for 10-20 s, while in the SPLD/TCSE group, RF power was 30-35 W, targeting a lesion size index (LSI) of 4.0-5.5. The co-primary study outcomes were time required to complete PVI and first pass isolation (FPI). RESULTS: PVI was achieved in 100% of patients in both groups, and no major adverse events were observed. Remarkably, PVI time was shorter in the HPSD/TFSE, compared to the SPLD/TCSE group(9 [7-9] min vs. 50 [37-54] min; p < 0.001), while FPI rate was non-significantly higher in the former group(91% [146/160] vs 83% [134/160]; p = 0.063). Shorter procedural (108 [91-120] min vs. 173 [139-187] min, p < 0.001), total RF (9 [7-11] min vs. 43 [32-53] min, p < 0.001), fluoroscopy times(15 [10-19] min vs. 18 [13-26] min, p = 0.014), and lower DAP (1461 [860-2181] vs. 7200 [3400-20,800], p < 0.001) were recorded in the HPSD/TFSE group. A higher average impedance drop was obtained with HPSD/TFSE CA(17[17-18]Ω vs. 16 [15-17] Ω, p < 0.001). CONCLUSIONS: In our initial clinical experience, HPSD PVI with the TFSE catheter proved faster than SPLD PVI with the TCSE catheter, at least equally effective in terms of FPI, and it was associated with greater impedance drop.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Ablação por Cateter/efeitos adversos , Catéteres , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
19.
Can J Cardiol ; 40(3): 372-384, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37923125

RESUMO

BACKGROUND: Cardiac amyloidoses (CAs) are an increasingly recognised group of infiltrative cardiomyopathies associated with high risk of adverse cardiac events. We sought to characterise the characteristics and clinical value of right ventricular (RV) electroanatomic voltage mapping (EVM) in CA. METHODS: Fifteen consecutive patients undergoing endomyocardial biopsy (EMB) for suspected CA (median age 75 years, 1st-3rd quartiles 64-78 years], 67% male) were enrolled in an observational prospective study. Each patient underwent RV high-density EVM using a multipolar catheter and EMB. The primary outcome was death or heart failure hospitalisation at 1-year follow-up. We recorded electrographic features at EMB sampling sites and electroanatomic data in the overall RV, and explored their correlations with histopathologic findings and primary outcomes events. RESULTS: A final EMB-proven diagnosis of immunoglobulin light chain or transthyretin CA was formulated in 6 and 9 patients, respectively. Electrogram amplitudes in the bipolar and unipolar configurations averaged 1.55 ± 0.44 mV and 5.14 ± 1.50 mV, respectively, in the overall RV, with lower values in AL CA patients. We found a significant inverse correlation between both bipolar and unipolar electrogram amplitude and amyloid burden according to EMB (P = 0.001 and P = 0.025, respectively). At 1-year follow-up, 7 patients (47%) experienced a primary outcome event; the extent of bipolar dense scar area at RV EVM was an independent predictor of primary outcome events at multivariable analysis (odds ratio 2.40; P = 0.037). CONCLUSIONS: In CA, electrogram amplitudes are around the lower limit of normal yet disproportionately low compared with the increased wall thickness. Out data suggest that RV electrogram amplitude may be a quantitative marker of amyloid burden, and that RV EVM may have prognostic value.


Assuntos
Amiloidose , Displasia Arritmogênica Ventricular Direita , Humanos , Masculino , Idoso , Feminino , Displasia Arritmogênica Ventricular Direita/complicações , Estudos Prospectivos , Técnicas Eletrofisiológicas Cardíacas , Ventrículos do Coração , Amiloidose/complicações
20.
Artigo em Inglês | MEDLINE | ID: mdl-38087147

RESUMO

BACKGROUND: Several novel technologies allowing catheter ablation (CA) with a favorable safety/efficacy profile have been recently developed, but not yet extensively clinically tested in the setting of ventricular tachycardia CA. METHODS: In this technical report, we overview technical aspects and preclinical/clinical information concerning the application of three novel CA technologies in the ventricular milieu: a pulsed field ablation (PFA) generator (CENTAURI™, Galaxy Medical) to be used with linear, contact force-sensing radiofrequency ablation catheters; a contact force-sensing radiofrequency ablation catheter equipped with six thermocouples and three microelectrodes (QDOT Micro™, Biosense-Webster), allowing high-resolution mapping and temperature-controlled CA; and a flexible and mesh-shaped irrigation tip, contact force-sensing radiofrequency ablation catheter (Tactiflex, Abbott). We also report three challenging VT cases in which CA was performed using these technologies. RESULTS: The CENTAURI system was used with the Tacticath™ (Abbott) ablation catheter to perform ventricular PFA in a patient with advanced heart failure, electrical storm, and a deep intramural septal substrate. Microelectrode mapping using QDOT Micro™ helped to refine substrate assessment in a VT patient with congenitally corrected transposition of the great arteries, and allowed the identification of the critical components of the VT circuit, which were successfully ablated. Tactiflex™ was used in two challenging CA cases (one endocardial and one epicardial), allowing acute and mid-term control of VT episodes without adverse events. CONCLUSION: The ideation and development of novel technologies initially intended to treat atrial arrhythmias and successfully implemented in the ventricular milieu is contributing to the progressive improvement in the clinical benefits derived from VT CA, making this procedure key for successful management of increasingly complex patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...