Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Expert Rev Med Devices ; 20(12): 1243-1249, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37897179

RESUMO

BACKGROUND: Persistent dyspnea is frequent in post-COVID patients, even in the absence of pulmonary embolism (PE). In this scenario, the role of lung perfusion scintigraphy is unclear. The present study correlated scintigraphy-based semiquantitative perfusion parameters with chest high-resolution computed tomography (hrCT) volumetric indexes and clinical data in post-COVID patients with persistent dyspnea. RESEARCH DESIGN AND METHODS: Sixty patients (30 post-COVID and 30 not previously affected by COVID-19) with persistent dyspnea submitted to lung perfusion scintigraphy and hrCT were retrospectively recruited. Perfusion rates of the pulmonary fields and hrCT-based normalized inflated, emphysematous, infiltrated, collapsed, and vascular lung volumes were calculated. Inflammatory and coagulation biomarkers were collected. PE at imaging was an exclusion criterion. RESULTS: Compared to controls, reduced perfusion rates of the lower pulmonary fields and higher perfusion rates of the middle ones were observed in post-COVID patients, while hrCT findings were superimposable between the two groups. Perfusion rates of lower pulmonary fields were significantly associated only with abnormal lung volumes at hrCT. CONCLUSIONS: In post-COVID dyspnea without PE, lung perfusion scintigraphy may reveal a pulmonary involvement not detectable by hrCT. Post-COVID patients may show decreased perfusion rates of lower pulmonary fields in the presence of normal vascular density and markers of inflammation/coagulation.


Assuntos
COVID-19 , Embolia Pulmonar , Humanos , Estudos Retrospectivos , COVID-19/complicações , COVID-19/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Imagem de Perfusão/métodos , Dispneia/diagnóstico por imagem , Dispneia/etiologia , Perfusão
2.
Front Physiol ; 12: 780713, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34975534

RESUMO

Objective: Sympathetic nervous system (SNS) reaction to exercise is gender dependent. Nevertheless, clinically applicable methods to identify this difference are still missing. An organ largely sensitive to SNS is the spleen whose response to exercise can be easily evaluated, being included in the field of view of myocardial perfusion imaging (MPI). Here, we aimed to verify whether gender interferes with the spleen perfusion and its response to exercise. Methods: For this purpose, we evaluated 286 original scans of consecutive patients submitted to MPI in the course of 2019. Our standard procedure implies a single-day stress-rest sequence with a gap of ≥2 h between the administrations of 180 and 500 MBq of 99mTc-Sestamibi, respectively. Imaging is performed 30 min after radiotracer administration, with scan duration set at 25 and 35 s per view, respectively. Non-gated scans were reconstructed with the filtered back-projection method. A volume of interest was drawn on the spleen and heart to estimate the dose-normalized average counting rate that was expressed in normalized counts per seconds (NCPS). Results: In all subjects submitted to exercise MPI (n = 228), NCPS were higher during stress than at rest (3.52 ± 2.03 vs. 2.78 ± 2.07, respectively; p < 0.01). This effect was not detected in the 58 patients submitted to dipyridamole-stress. The response to exercise selectively involved the spleen, since NCPS in heart were unchanged irrespective of the used stressor. This same response was dependent upon gender, indeed spleen NCPS during stress were significantly higher in the 75 women than in the 153 men (3.86 ± 1.8 vs. 3.23 ± 1.6, respectively, p < 0.01). Again, this variance was not reproduced by heart. Finally, spleen NCPS were lower in the 173 patients with myocardial reversible perfusion defects (summed difference score ≥3) than in the remaining 55, despite similar values of rate pressure product at tracer injection. Conclusion: Thus, exercise interference on spleen perfusion can be detected during MPI. This effect is dependent upon gender and ischemia confirming the high sensitivity of this organ to SNS activation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...