Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 28(20): 28924-28941, 2020 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-33114801

RESUMO

We investigate the coherence of plasma-based soft X-ray laser (XRL) for different conditions that can alter the electron density in the gain region. We first measure the source temporal coherence in amplified spontaneous emission (ASE) mode. We develop a data analysis procedure to extract both its spectral width and pulse duration. These findings are in agreement with the spectral line shape simulations and seeded operation experimental results. Utilizing the deduced spectral width and pulse duration in a one-dimensional Bloch-Maxwell code, we reproduce the experimental temporal coherence properties of the seeded-XRL. Finally, we demonstrate efficient lasing in ASE and seeded mode at an electron density two times higher than the routine conditions. In this regime, using Bloch-Maxwell modeling, we predict the pulse duration of the seeded XRL to be ∼500fs.

2.
Opt Express ; 24(13): 14260-70, 2016 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-27410582

RESUMO

Development of efficient soft x-ray laser plasma amplifiers adapted to seeded operation, requires a better control over amplifier transverse spatial extent, brilliance control and gain lifetime. Here it is shown that pumping the plasma amplifier with one long and two short pump pulses (1L2S) provides advantages in terms of control for the specified parameters in the case of Ni-like Ag x-ray laser. Also, significant tunability of the gain lifetime in the 1L2S pumping scheme for Ne-like Ti x-ray laser is observed. Direct harmonics seeding and chirped harmonics seeding amplification approaches may benefit from the control of the gain lifetime, in terms of better use of the pump energy and as a way to reduce the amplified spontaneous emission in x-ray lasers.

3.
Opt Lett ; 39(21): 6102-5, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-25361289

RESUMO

We have investigated a new scheme for laser plasma transient collisional soft x-ray lasers based on the use of an additional laser to produce the preplasma. Soft x-ray emission measurements made for different solid targets are presented and discussed. A significant enhancement of the SXRL emission as compared to double-pulse single-beam grazing incidence (DGRIP) using the same pump laser is reported for 13.9- and 32.6-nm SXRL wavelengths.

4.
Opt Lett ; 39(8): 2246-9, 2014 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-24978964

RESUMO

An alternative, novel multiple pulse generation scheme was implemented directly after the optical compressor output of an x-ray pump laser. The new method uses a polarization sensitive thin film beam splitter and a half-wavelength wave plate for tuning the energy ratio in the multiple short pulses. Based on this method, an extensive study was made of the running parameters for a grazing incidence pumped silver x-ray laser (XRL) pumped with a long pulse of 145 mJ in 6 ns at 532 nm and up to 1.45 J in few picoseconds at 810 nm. Fivefold enhancement in the emission of the silver XRL was demonstrated using the new pump method.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...