Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Jt Dis Relat Surg ; 35(2): 448-454, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38727128

RESUMO

Several surgical procedures are used to treat dynamic pronation position of the forearm and flexion deformity of the wrist in cerebral palsy. Postoperative results of pronator teres rerouting were explored, while specially designed postoperative physiotherapy and its outcomes were limited. Herein, we present a case in whom the outcomes of electromyographic biofeedback (EMG-BF) training were assessed after pronator teres rerouting and brachioradialis tendon to extensor carpi radialis brevis tendon transfer combined with derotation osteotomy. The peak value increased, while the resting value decreased for the muscles after the intervention. Range of motion, hand function, manual ability, functional independence, and quality of life levels were improved. In conclusion, EMG biofeedback training may have a positive effect on neuromuscular control of pronator teres and brachioradialis. Free use of the upper extremity and improved manual ability positively affect the activity and quality of life of the patients.


Assuntos
Paralisia Cerebral , Músculo Esquelético , Amplitude de Movimento Articular , Transferência Tendinosa , Humanos , Transferência Tendinosa/métodos , Paralisia Cerebral/cirurgia , Paralisia Cerebral/reabilitação , Paralisia Cerebral/fisiopatologia , Músculo Esquelético/cirurgia , Músculo Esquelético/fisiopatologia , Masculino , Antebraço/cirurgia , Eletromiografia , Qualidade de Vida , Resultado do Tratamento , Biorretroalimentação Psicológica/métodos , Osteotomia/métodos , Pronação/fisiologia , Recuperação de Função Fisiológica/fisiologia
2.
Acta Ortop Bras ; 32(1): e267640, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38532863

RESUMO

Introduction: The Judet and Letournel classification is the most widely used classification system for acetabular fractures. Some complex fractures couldn't be classified according to this classification. The main purpose of this study was to evaluate the reliability of the Letournel and Judet classification system for acetabular fractures. Material and methods: 10 acetabular fractures were analyzed among 17 orthopedic surgeons. The surgeons were asked to classify the fractures according to the Judet and Letournel classification. Their experience, the number of surgeries, and the incision type that the surgeon uses for the anterior part of the acetabulum were recorded. Results: The overall interobserver agreement for the Letournel classification was found to be poor, with a Kappa value of 0.287. The Kappa value for interobserver agreement was 0.224 for plain radiographs, 0.293 for 2D-CT, and 0.321 for 3D-CT scans. There was no significant difference between the incision types used by the surgeons. The highest reliability was determined among the surgeons who operate on 10-20 acetabular fractures per year, with a Kappa value of 0.309. Conclusion: This results revealed that the Judet and Letournel Judet classification is not sufficient to classify acetabular fractures because of unclassified fractures and the complex algorithm of the system. Level of Evidence III; Comparative Retrospective Study.


Introdução: A classificação de Judet e Letournel é o sistema de classificação mais amplamente utilizado para fraturas acetabulares. Algumas fraturas complexas, porém, não puderam ser classificadas de acordo com esta classificação. O principal objetivo deste estudo foi avaliar a confiabilidade do sistema de classificação de Judet e Letournel para fraturas acetabulares. Material e métodos: Foram selecionadas aleatoriamente 10 fraturas acetabulares de um banco de dados. Participaram do estudo 17 cirurgiões ortopédicos. Foi solicitado aos cirurgiões que classificassem as fraturas de acordo com a classificação de Judet e Letournel. Suas experiências, o número de cirurgias e o tipo de incisão que o cirurgião utiliza para a parte anterior do acetábulo foram registrados. Resultados: A concordância interobservadores geral para a classificação de Judet e Letournel foi considerada fraca, com um valor de Kappa de 0,287. O valor de Kappa para a concordância interobservadores foi de 0,224 para radiografias simples, 0,293 para tomografias computadorizadas em 2D e 0,321 para tomografias computadorizadas em 3D. Não houve diferença significativa entre os tipos de incisão utilizados pelos cirurgiões. A maior confiabilidade foi determinada entre os cirurgiões que operam de 10 a 20 fraturas acetabulares por ano, com um valor de Kappa de 0,309. Conclusão: Os resultados revelaram que a classificação de Judet e Letournel não é suficiente para classificar fraturas acetabulares devido a fraturas não classificadas e ao algoritmo complexo do sistema. Nível de Evidência III; Estudo Comparativo Retorpectivo.

3.
Acta ortop. bras ; 32(1): e267640, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1549999

RESUMO

ABSTRACT Introduction: The Judet and Letournel classification is the most widely used classification system for acetabular fractures. Some complex fractures couldn't be classified according to this classification. The main purpose of this study was to evaluate the reliability of the Letournel and Judet classification system for acetabular fractures. Material and methods: 10 acetabular fractures were analyzed among 17 orthopedic surgeons. The surgeons were asked to classify the fractures according to the Judet and Letournel classification. Their experience, the number of surgeries, and the incision type that the surgeon uses for the anterior part of the acetabulum were recorded. Results: The overall interobserver agreement for the Letournel classification was found to be poor, with a Kappa value of 0.287. The Kappa value for interobserver agreement was 0.224 for plain radiographs, 0.293 for 2D-CT, and 0.321 for 3D-CT scans. There was no significant difference between the incision types used by the surgeons. The highest reliability was determined among the surgeons who operate on 10-20 acetabular fractures per year, with a Kappa value of 0.309. Conclusion: This results revealed that the Judet and Letournel Judet classification is not sufficient to classify acetabular fractures because of unclassified fractures and the complex algorithm of the system. Level of Evidence III; Comparative Retrospective Study.


RESUMO Introdução: A classificação de Judet e Letournel é o sistema de classificação mais amplamente utilizado para fraturas acetabulares. Algumas fraturas complexas, porém, não puderam ser classificadas de acordo com esta classificação. O principal objetivo deste estudo foi avaliar a confiabilidade do sistema de classificação de Judet e Letournel para fraturas acetabulares. Material e métodos: Foram selecionadas aleatoriamente 10 fraturas acetabulares de um banco de dados. Participaram do estudo 17 cirurgiões ortopédicos. Foi solicitado aos cirurgiões que classificassem as fraturas de acordo com a classificação de Judet e Letournel. Suas experiências, o número de cirurgias e o tipo de incisão que o cirurgião utiliza para a parte anterior do acetábulo foram registrados. Resultados: A concordância interobservadores geral para a classificação de Judet e Letournel foi considerada fraca, com um valor de Kappa de 0,287. O valor de Kappa para a concordância interobservadores foi de 0,224 para radiografias simples, 0,293 para tomografias computadorizadas em 2D e 0,321 para tomografias computadorizadas em 3D. Não houve diferença significativa entre os tipos de incisão utilizados pelos cirurgiões. A maior confiabilidade foi determinada entre os cirurgiões que operam de 10 a 20 fraturas acetabulares por ano, com um valor de Kappa de 0,309. Conclusão: Os resultados revelaram que a classificação de Judet e Letournel não é suficiente para classificar fraturas acetabulares devido a fraturas não classificadas e ao algoritmo complexo do sistema. Nível de Evidência III; Estudo Comparativo Retorpectivo.

4.
Physiother Theory Pract ; 39(8): 1563-1573, 2023 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-35229697

RESUMO

BACKGROUND: Despite advances in hand therapy and surgery, functional deficits persist after flexor tendon repair especially in zone I-III. This suggests that methods applied may be insufficient. Electromyographic (EMG) biofeedback may provide an effective tendon gliding through visual and auditory feedback. PURPOSE: The purpose of this study was to investigate the effect of EMG biofeedback training applied in addition to early passive motion protocol on functional status in zone I-III flexor tendon injuries. METHODS: Patients were randomly assigned into two groups, each consisted of 11 patients. In addition to early passive motion method, EMG biofeedback training was applied in the first group. The second group was followed only with early passive motion protocol. Joint range of motion (ROM), Michigan Hand Outcomes Questionnaire (MHQ) and grip strength were evaluated. RESULTS: There were no significant differences between the groups in terms of the ROM, MHQ scores and grip strength (p ≥ .087). However, there were clinically important differences in the results of the 12th week ROM (effect size = 0.70), 24th week activity of daily living (ADL) score in MHQ (effect size = 0.68), 12th week gross, tip pinch and lateral grip strength (effect sizes = 0.59, 0.52, 0.81, respectively) and 24th week gross, tip pinch and lateral grip strength (effect sizes = 0.69, 0.73, 0.69, respectively) between the two groups. CONCLUSIONS: EMG biofeedback training was clinically but not statistically superior to early passive motion method in terms of the effect on functional status.


Assuntos
Biorretroalimentação Psicológica , Traumatismos dos Tendões , Humanos , Estado Funcional , Eletromiografia , Traumatismos dos Tendões/cirurgia , Tendões/cirurgia , Amplitude de Movimento Articular
5.
Jt Dis Relat Surg ; 31(1): 14-9, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32160488

RESUMO

OBJECTIVES: This study aims to investigate if geometrical modelling in addition to three-dimensional (3D) modelling will standardize models and allow performing mathematical calculations easily for the compatibility of femoral implant curvature. PATIENTS AND METHODS: The study included 50 subjects (27 males, 23 females; mean age 55 years; range, 21 to 84 years). The femoral shaft intramedullary cavity was resembled into a chord of the ring cyclide, where the rotational radius was centered at its smallest radius. A 3D evaluation of the left femoral computed tomography data of the subjects was used to investigate the population parameters. The fitting was defined as being between the anterior and posterior border radii in the sagittal plane. RESULTS: The best fitting radius of implants was in between 90 to 99 cm in 72% of subjects in our sample. These radii values were lower than the mean intramedullary and cortical centerline radii which had only 62% and 50% fittings, respectively, among our population sample. The bowing radii and the smallest intramedullary width increased with the femoral length. These values were not affected by gender. CONCLUSION: This modelling may have value for understanding femoral shaft intramedullary cavity geometry and may be a good tool to assess implant fitting.


Assuntos
Fêmur/diagnóstico por imagem , Imageamento Tridimensional/métodos , Rádio (Anatomia)/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Feminino , Fêmur/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Rádio (Anatomia)/cirurgia
6.
Jt Dis Relat Surg ; 31(1): 28-33, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32160490

RESUMO

OBJECTIVES: This study aims to investigate the usability and reliability of our new axis in a three-dimensional modelling work and demonstrate if it is a reproducible method for anteversion measurement that sufficiently correlates with other computed tomography (CT)-derived gold standards including trans- epicondylar axis (TEA) and posterior condylar axis (PCA). PATIENTS AND METHODS: Three-dimensional solid models were derived from left femoral CT data of 100 participants (50 males, 50 females; mean age 57 years; range, 21 to 86). The newly proposed popliteal surface axis (PSA) was compared with TEA and PCA in terms of anteversion measurement on these solid models. RESULTS: Popliteal surface axis was found as a reproducible reference axis in our study as it could be measured in 99% of our sample. The mean value of PSA based anteversion was (-) 1.8° which was 10.7° and 4.4° for PCA and TEA, respectively. Popliteal surface axis was perfectly correlated with PCA and TEA for anteversion measurements (p<0.001, r=0.92 for both). CONCLUSION: Our findings suggest that the newly defined PSA may be used as an alternative method for determination of anteversion.


Assuntos
Fêmur/diagnóstico por imagem , Imageamento Tridimensional/métodos , Articulação do Joelho/diagnóstico por imagem , Precisão da Medição Dimensional , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
7.
Jt Dis Relat Surg ; 31(1): 34-8, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32160491

RESUMO

OBJECTIVES: This study aims to investigate the reliability of the Lichtman classification among residents, orthopedic surgeons, and hand surgeons. MATERIALS AND METHODS: This study was carried out with 30 male observers (mean age 37.8 years; range, 26 to 62 years) who agreed to participate in the study. All observers were orthopedic surgeons. The observers were separated into three groups that consist of 10 residents, 10 orthopedic surgeons, and 10 hand surgeons. The anteroposterior and lateral wrist radiographs of 20 patients (12 males, 8 females; mean age 49 years; range, 38 to 74 years) diagnosed as Kienböck's disease were sent to observers via e-mail as a survey. All 40 radiographs were asked to be kept classified. RESULTS: The classification of Kienböck's disease was analyzed by 30 observers on 40 digital radiographs. The overall agreement with the Lichtman classification was fair within all of the observers (kappa=0.203). When groups were evaluated within themselves, the agreement level was found poor in group 1 (kappa=0.162) and fair in group 2 (kappa=0.210) and group 3 (kappa=0.252). CONCLUSION: A useful classification system in orthopedics and traumatology should classify the type of musculoskeletal disorder reliably, facilitate communication in clinical practice, guide preoperative planning, and enable comparison of results between studies. The Lichtman classification alone is insufficient and should be supported by other imaging and measurement techniques.


Assuntos
Classificação/métodos , Osteonecrose , Atitude do Pessoal de Saúde , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Cirurgiões Ortopédicos , Ortopedia/normas , Osteonecrose/classificação , Osteonecrose/diagnóstico , Radiografia/métodos , Reprodutibilidade dos Testes , Inquéritos e Questionários , Traumatologia/normas
8.
Eklem Hastalik Cerrahisi ; 30(2): 124-9, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31291860

RESUMO

OBJECTIVES: This study aims to clinically evaluate the efficacy of pedicle bone flap treatment in stage II Kienböck's disease. PATIENTS AND METHODS: This retrospective study included 10 patients (8 males, 2 females; mean age 33.3 years; range, 23 to 46 years) treated with pedicle bone flap between January 2012 and June 2016. In all patients, a fourth extensor compartment artery (ECA) pedicle bone flap from the dorsal surface of the radius was prepared and placed through a window opened on the lunate bone. Clinical results of the patients were evaluated according to the Mayo wrist score. RESULTS: All patients could return to their daily activities after surgery. No superficial or deep infection developed requiring debridement or antibiotic use other than prophylaxis. None of the patients required reoperation due to complications or the progression of the disease. The mean Mayo wrist score was measured as 81 (good). CONCLUSION: In this study, results of the fourth ECA pedicle bone flap application were found to be effective in the treatment of avascular necrosis of the lunate bone. Further comparative and long-term follow-up studies are required including large and homogeneous patient groups.


Assuntos
Transplante Ósseo , Osso Semilunar/cirurgia , Osteonecrose/cirurgia , Rádio (Anatomia)/transplante , Retalhos Cirúrgicos , Adulto , Feminino , Humanos , Osso Semilunar/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Osteonecrose/diagnóstico por imagem , Osteonecrose/fisiopatologia , Estudos Retrospectivos , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/fisiopatologia , Adulto Jovem
9.
J Cell Biochem ; 120(7): 11525-11530, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30816601

RESUMO

The aim of this study is to investigate the effects of type I collagen on bone defects and on genes specifically for osteogenesis in a rat model. Two millimeter drill hole bone defect was created in the femur of rats. In the experimental group, type I collagen was applied in bone defects whereas in control group defects were left empty. Inflammation, development of connective tissue, osteogenesis, and foreign body reaction parameters evaluated with histologically and genes evaluated by blood samples. In the experimental group, the histopathologically significant change was found in favor of bone healing only at the first week. A significant increase was found in genetic expressions of BMP-1, 2, 3, 4, 5, 6, 7, TGF-ßRII, Smad-1, IL-6, BMPR-IA, BMPR-IB, Eng, BMPR-II, c-fos, Cdkn1a, Chrd, Gdf-5, Id-1, PDGF-ß, IGF-1, Serpine-1, and TGF-ßRI at the first hour. At the first, third, and sixth week, no significant increase was found in any of the gene expressions. Type I collagen is found to be effective in favor of bone healing through increased inflammatory cytokines and expression of BMP genes in the early stages of fracture healing.

10.
Acta Orthop Traumatol Turc ; 52(4): 294-298, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29735339

RESUMO

OBJECTIVE: The aim of this study was to describe an alternative fixation method for distal humeral extra-articular fractures through posterior approach using distal tibia anatomic locking plate; and to evaluate the patient's functional outcome and union condition. METHODS: Eighteen patients (11 men and 7 women; average age of 37.0 ± 17.3 years (range: 18-73 years)) with a distal humeral extra-articular fracture who were treated with distal tibial medial locking plate were included into the study. The mean follow up time was 36.2 ± 16.7 (12-57) months. Functional results were evaluated with perception of pain, range of joint motion, grasp and pinch strengths. RESULTS: Union was achieved in 17 of 18 patients. Only one patient had non-union due to infection and underwent debridement. The mean time for union was 7.8 ± 5.9 months (2-20). Patient perception of pain was X = 1.88 ± 2.50 and X = 4.55 ± 2.68, respectively, at rest and activity. The active ranges of joint motion were adequate for functional use. General functional state of affected extremity (DASH-T) was perfect (X = 27.14 ± 25.66), the performance of elbow joint was good (X = 84.44 ± 11.57). There were no differences in the comparison of grasp and pinch grip of patients with uninvolved extremity (p > 0.05). CONCLUSIONS: In distal humeral extra-articular fractures, use of distal medial tibia plate has advantages such as providing high rates for union, low rates for complication, and early return to work with early rehabilitation, therefore it may be considered a fixation choice that can be used for distal humeral extra-articular fractures. LEVEL OF EVIDENCE: Level IV, therapeutic study.


Assuntos
Placas Ósseas , Articulação do Cotovelo/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas do Úmero/cirurgia , Amplitude de Movimento Articular/fisiologia , Adolescente , Adulto , Idoso , Articulação do Cotovelo/fisiopatologia , Feminino , Humanos , Fraturas do Úmero/fisiopatologia , Masculino , Pessoa de Meia-Idade , Força de Pinça , Resultado do Tratamento , Adulto Jovem
11.
Eklem Hastalik Cerrahisi ; 28(1): 30-4, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28291436

RESUMO

OBJECTIVES: This study aims to evaluate the effects of radial bowing changes on fracture healing and functional results in adult forearm intramedullary nail applications and complications of forearm nails that have been discussed rarely in the literature. PATIENTS AND METHODS: Twenty-three patients -11 with isolated radius and 12 with both radius and ulna fractures- (17 males, 6 females; mean age 38.6 years; range 18 to 69 years) who were operated between September 2009 and August 2014 were included in the study. The effects of radial bowing changes on bone healing rates, time to union, and functional levels of the forearm as well as complications of forearm nails were evaluated. RESULTS: We observed fracture healing without any complication in 20 patients (86.9%) and nonunion in three patients (13.1%) although six months had passed after the operation. Statistically significant difference was detected between radial bowing change and nonunion (p=0.01). Two patients (8.6%) with AO/OTA Classification (The Arbeitsgemeinschaft für Osteosynthesefragen [AO]/Orthopaedic Trauma Association [OTA] Classification), type B3 forearm double fractures had synostosis. Extensor pollicis longus tendon rupture or impingement was detected in six patients (26.8%) for which nails were applied on radius fracture. CONCLUSION: Intramedullary nail application may be an appropriate treatment alternative in forearm fractures with their high healing rates; however, synostosis may arise with its use in wedge fractures (AO/OTA type B3) at the same level. Although radial bowing changes do not have a significant effect on ranges of motion of the forearm, it should be kept in mind that fracture healing may be affected adversely in patients with radial bowing changes of high rates. Complications regarding extensor pollicis longus tendon may develop during intra- or postoperative periods in patients for which a radius nail has been applied.


Assuntos
Pinos Ortopédicos/efeitos adversos , Fixação Intramedular de Fraturas/efeitos adversos , Fraturas do Rádio/cirurgia , Rádio (Anatomia)/diagnóstico por imagem , Adolescente , Adulto , Idoso , Feminino , Antebraço , Fixação Intramedular de Fraturas/métodos , Consolidação da Fratura , Fraturas não Consolidadas/diagnóstico por imagem , Fraturas não Consolidadas/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Rádio (Anatomia)/patologia , Fraturas do Rádio/diagnóstico por imagem , Estudos Retrospectivos , Sinostose/diagnóstico por imagem , Sinostose/etiologia , Resultado do Tratamento , Adulto Jovem
12.
PLoS One ; 11(11): e0165544, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27806071

RESUMO

Gentamicin is the preferred antimicrobial agent used in implant coating for the prevention of implant-related infections (IRI). However, the present heavy local and systemic administration of gentamicin can lead to increased resistance, which has made its future use uncertain, together with related preventive technologies. Fosfomycin is an alternative antimicrobial agent that lacks the cross-resistance presented by other classes of antibiotics. We evaluated the efficacy of prophylaxis of 10% fosfomycin-containing poly(D,L-lactide) (PDL) coated K-wires in a rat IRI model and compared it with uncoated (Control 1), PDL-coated (Control 2), and 10% gentamicin-containing PDL-coated groups with a single layer of coating. Stainless steel K-wires were implanted and methicillin-resistant Staphylococcus aureus (ATCC 43300) suspensions (103 CFU/10 µl) were injected into a cavity in the left tibiae. Thereafter, K-wires were removed and cultured in tryptic soy broth and then 5% sheep blood agar mediums. Sliced sections were removed from the tibiae, stained with hematoxylin-eosin, and semi-quantitatively evaluated with X-rays. The addition of fosfomycin into PDL did not affect the X-ray and histopathological evaluation scores; however, the addition of gentamicin lowered them. The addition of gentamicin showed a protective effect after the 28th day of X-ray evaluations. PDL-only coating provided no protection, while adding fosfomycin to PDL offered a 20% level protection and adding gentamicin offered 80%. Furthermore, there were 103 CFU level growths in the gentamicin-added group, while the other groups had 105. Thus, the addition of fosfomycin to PDL does not affect the efficacy of prophylaxis, but the addition of gentamicin does. We therefore do not advise the use of fosfomycin as a single antimicrobial agent in coating for IRI prophylaxis.


Assuntos
Fios Ortopédicos/microbiologia , Fosfomicina/administração & dosagem , Gentamicinas/administração & dosagem , Osteomielite/prevenção & controle , Poliésteres/administração & dosagem , Infecções Estafilocócicas/prevenção & controle , Animais , Antibioticoprofilaxia , Materiais Revestidos Biocompatíveis/administração & dosagem , Materiais Revestidos Biocompatíveis/farmacologia , Modelos Animais de Doenças , Fosfomicina/farmacologia , Gentamicinas/farmacologia , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Staphylococcus aureus Resistente à Meticilina/crescimento & desenvolvimento , Ratos , Resultado do Tratamento
13.
Clin Anat ; 16(6): 511-3, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14566898

RESUMO

The spinoglenoid ligament and its anatomic variations are described in 27 shoulders from 15 cadavers. In each shoulder one or two distinct spinoglenoid ligaments originated from the base of the spine of the scapula; they inserted on the neck of the scapula or the shoulder joint capsule. In the 19 shoulders in which only one spinoglenoid ligament was present, it inserted into the neck of the scapula in 14 cases and into the shoulder joint capsule in five instances. In the eight shoulders in which there were two ligaments, one inserted into the neck of the scapula and the other into the shoulder joint capsule. We did not observe any hypertrophic spinoglenoid ligaments that may have compressed the suprascapular nerve.


Assuntos
Ligamentos Articulares/anatomia & histologia , Escápula/anatomia & histologia , Articulação do Ombro/anatomia & histologia , Cadáver , Feminino , Humanos , Masculino , Síndromes de Compressão Nervosa/etiologia , Síndromes de Compressão Nervosa/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...