Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
J Neurol Neurosurg Psychiatry ; 93(6): 617-624, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35387867

RESUMO

BACKGROUND: An unmet need remains for sensitive outcome measures in neuroprotective trials. The study aims to determine whether a composite clinical motor score, combining the Movement Disorders Society-Unified Parkinson's Disease Rating Scale (MDS-UPDRS) III motor examination score, Purdue Pegboard Test, and Timed Up and Go, provides greater sensitivity in detecting motor change in early disease than the MDS-UPDRS III alone. METHODS: The Oxford Discovery longitudinal cohort study involves individuals with isolated rapid eye movement sleep behaviour disorder (iRBD) (n=272, confirmed polysomnographically, median follow-up: 1.6 years), idiopathic Parkinson's disease (PD) (n=909, median follow-up: 3.5 years, baseline: <3.5 years disease duration) and controls (n=316, age-matched and sex-matched, without a first-degree family history of PD). Motor and non-motor assessments were performed at each in-person visit. RESULTS: Compared with the MDS-UPDRS III, the composite clinical motor score demonstrated a wider score distribution in iRBD and controls, lower coefficient of variation (37% vs 67%), and higher correlation coefficients with self-reported measures of motor severity (0.65 vs 0.61) and overall health status (-0.40 vs -0.33). Greater score range in mild to moderate PD, higher magnitude of longitudinal change in iRBD and longitudinal score linearity suggest better sensitivity in detecting subtle motor change. The composite clinical motor score was more accurate than the MDS-UPDRS III in predicting clinical outcomes, requiring 64% fewer participants with PD and 51% fewer participants with iRBD in sample size estimations for a hypothetical 18-month placebo-controlled clinical trial. CONCLUSION: The composite clinical motor score may offer greater consistency and sensitivity in detecting change than the MDS-UPDRS III.


Assuntos
Doença de Parkinson , Transtorno do Comportamento do Sono REM , Humanos , Estudos Longitudinais , Testes de Estado Mental e Demência , Avaliação de Resultados em Cuidados de Saúde , Doença de Parkinson/diagnóstico , Índice de Gravidade de Doença
2.
Brain Inj ; 34(11): 1525-1531, 2020 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-32835526

RESUMO

STUDY OBJECTIVES: To identify the prevalence of excessive daytime sleepiness (EDS) in a prospectively recruited patient population with traumatic brain injury (TBI) of mixed severity. Furthermore, the study aimed to assess the relationship between patient factors and EDS. METHOD: One-hundred and eighteen patients with TBI were assessed in a neurorehabilitation clinic after discharge from the emergency department. Enrolled participants were evaluated using several TBI-related outcome measures, 6-8 weeks after injury. RESULTS: EDS (defined using the Epworth Sleepiness Scale ≥10) occurred in 48 of 118 (41.7%) patients in this study. Anxiety; depression; change in ability to work; employment status; global outcome (GOSE); social and functional outcome (RHFUQ); and symptom severity (RPCS) were associated with EDS in a univariate analysis. Anxiety was the only factor associated with EDS in the multivariate analysis (OR: 0.28 [95% CI: 0.09-0.90], P = .032). CONCLUSION: EDS is common after TBI in a community setting and is associated with several factors, which likely interact to contribute toward worse outcome. Anxiety is a factor that, if routinely assessed and considered during patient care choices, may assist in favorable sleep-related outcome during and after post-TBI recovery.


Assuntos
Lesões Encefálicas Traumáticas , Distúrbios do Sono por Sonolência Excessiva , Ansiedade/epidemiologia , Ansiedade/etiologia , Lesões Encefálicas Traumáticas/complicações , Lesões Encefálicas Traumáticas/epidemiologia , Distúrbios do Sono por Sonolência Excessiva/epidemiologia , Distúrbios do Sono por Sonolência Excessiva/etiologia , Humanos , Prevalência , Sono
3.
Seizure ; 79: 8-13, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32380376

RESUMO

PURPOSE: On 24/04/2018, the United Kingdom (UK) Medicines and Healthcare Products Regulatory Agency (MHRA) clarified previous policies by issuing a statement, that the use of sodium valproate is contraindicated in women of childbearing potential unless the conditions of a pregnancy prevention programme are met, and only if other treatments are ineffective or not tolerated. We evaluated the impact of this over the first year of implementation in a tertiary epilepsy centre. METHODS: Cross-sectional study of all women under active follow up, or newly referred, of childbearing age (16-55 years), taking valproate for the treatment of epilepsy, over 12 months from 01/05/2018. RESULTS: We identified 125 cases, with 31 newly referred in response to MHRA regulations. 9.6% of patients did not attend their appointment, 35.2% had a learning disability (LD), which in 19.2% was sufficiently severe that they could not consent to a sexual relationship. Patients with LD prescribed valproate were significantly younger, and more likely to have a focal or uncharacterised epilepsy than patients without LD. In 46.4% of patients, MHRA regulations were followed: women were already using highly active contraception (HAC), HAC was started, or valproate withdrawn. In 24.8% of cases, women elected to continue valproate, and were not willing to use HAC. CONCLUSIONS: In 53.6% of cases, MHRA regulations contraindicating the use valproate in women of childbearing potential could not be followed fully, due to lack of patient attendance, lack of applicability in severe LD, or ethical concerns relating to patient choice.


Assuntos
Anticonvulsivantes/uso terapêutico , Anticoncepção/estatística & dados numéricos , Contraindicações de Medicamentos , Epilepsia/tratamento farmacológico , Deficiências da Aprendizagem , Complicações na Gravidez/induzido quimicamente , Complicações na Gravidez/prevenção & controle , Ácido Valproico/uso terapêutico , Adolescente , Adulto , Estudos Transversais , Epilepsia/epidemiologia , Feminino , Humanos , Deficiências da Aprendizagem/epidemiologia , Pessoa de Meia-Idade , Gravidez , Reino Unido/epidemiologia , Adulto Jovem
4.
Int J Occup Environ Health ; 24(3-4): 75-85, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30281413

RESUMO

The legal Australian cannabis industry has been rapidly expanding due to increased awareness of the plant's therapeutic potential, as well its diverse range of applications including biofuel, textiles, building materials, food, nutritional supplement, and animal feed. The objective of this paper is to describe the current landscape of the commercial Australian cannabis industry, summarise occupational health and safety (OHS) hazards in cannabis-related working environments, and provide suggestions for safeguarding worker health and well-being in this emerging industry. A comprehensive search of peer-reviewed and grey literature published between 1900 and 2017 was undertaken to identify case studies and original epidemiological research on OHS hazards associated with the cannabis cultivation and the manufacture of cannabis-based products. The review found that the majority of OHS studies were undertaken in the hemp textile industry during the late twentieth century, with a small number of articles published from a variety of occupational environments including forensic laboratories and recreational marijuana farms. Cannabis harvesting and initial processing is labour intensive, and presents a physical hazard Depending on the operation, workers may also be exposed to a variety of biological, chemical, and physical hazards including: organic dusts, bioaerosols, pollen/allergens, volatile organic compounds, psychoactive substances (tetrahydrocannabinol [THC])), noise, and ultraviolet radiation. Little research has been undertaken on the exposure to inhalable organic dust and other bioaerosols during the commercial cultivation and manufacture of cannabis-based products. Furthermore, there is an absence of Australian-based research and OHS guidance materials to help professionals develop risk management strategies in this evolving industry. It is recommended that: Investigation into the toxicological properties of cannabis dusts, specifically in relation to potential occupational exposures during cultivation and manufacture, should be a priority. The interim adoption of the respirable cotton dust exposure standard of 0.2 mg/m3 for workplace exposure in hemp facilities until a cannabis workplace exposure standard is developed, and that exposure to medicinal cannabis containing THC are kept as low as reasonably practicable. An industry partnership be established for the development of an Australian health and safety guideline for the production of medicinal cannabis and hemp. A classification to meet the requirements of the Global Harmonization Scheme should be undertaken to ensure consistency in the use of safety and risk phrases in cannabis-related industries.


Assuntos
Cannabis , Saúde Ocupacional , Gestão da Segurança , Aerossóis , Agricultura/métodos , Poluentes Ocupacionais do Ar , Alérgenos , Cannabis/química , Humanos , Exposição Ocupacional/prevenção & controle , Compostos Fitoquímicos , Compostos Orgânicos Voláteis
5.
Neurology ; 91(16): e1528-e1538, 2018 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-30232246

RESUMO

OBJECTIVE: We sought to identify motor features that would allow the delineation of individuals with sleep study-confirmed idiopathic REM sleep behavior disorder (iRBD) from controls and Parkinson disease (PD) using a customized smartphone application. METHODS: A total of 334 PD, 104 iRBD, and 84 control participants performed 7 tasks to evaluate voice, balance, gait, finger tapping, reaction time, rest tremor, and postural tremor. Smartphone recordings were collected both in clinic and at home under noncontrolled conditions over several days. All participants underwent detailed parallel in-clinic assessments. Using only the smartphone sensor recordings, we sought to (1) discriminate whether the participant had iRBD or PD and (2) identify which of the above 7 motor tasks were most salient in distinguishing groups. RESULTS: Statistically significant differences based on these 7 tasks were observed between the 3 groups. For the 3 pairwise discriminatory comparisons, (1) controls vs iRBD, (2) controls vs PD, and (3) iRBD vs PD, the mean sensitivity and specificity values ranged from 84.6% to 91.9%. Postural tremor, rest tremor, and voice were the most discriminatory tasks overall, whereas the reaction time was least discriminatory. CONCLUSIONS: Prodromal forms of PD include the sleep disorder iRBD, where subtle motor impairment can be detected using clinician-based rating scales (e.g., Unified Parkinson's Disease Rating Scale), which may lack the sensitivity to detect and track granular change. Consumer grade smartphones can be used to accurately separate not only iRBD from controls but also iRBD from PD participants, providing a growing consensus for the utility of digital biomarkers in early and prodromal PD.


Assuntos
Doença de Parkinson/diagnóstico , Transtorno do Comportamento do Sono REM/diagnóstico , Smartphone , Idoso , Feminino , Dedos/fisiopatologia , Marcha , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/psicologia , Equilíbrio Postural , Desempenho Psicomotor , Transtorno do Comportamento do Sono REM/psicologia , Tempo de Reação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tremor/diagnóstico , Tremor/psicologia , Voz
6.
Seizure ; 56: 26-30, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29427835

RESUMO

PURPOSE: Phenytoin is an effective anticonvulsant for focal epilepsy. Its use can be associated with long-term adverse effects including cerebellar ataxia. Whilst phenytoin is toxic to Purkinje cells in vitro; the clinical and radiological phenotype and mechanism of cerebellar degeneration in vivo remain unclear. We describe the prevalence, clinical and radiological characteristics of phenytoin-related ataxia. METHODS: Patients with epilepsy receiving treatment with phenytoin were recruited from the Epilepsy clinics at Royal Hallamshire Hospital, Sheffield, UK. Neurological examination was performed on all patients after recruitment. Patients were categorised into those with and without ataxia. We determined the severity of ataxia clinically (SARA score) and the pattern of cerebellar involvement by neuroimaging (MRI volumetry and MR spectroscopy). RESULTS: Forty-seven patients were recruited. Median duration of epilepsy was 24 years, median duration of phenytoin treatment was 15 years and current median phenytoin daily dose was 325 mg. Fifty-five percent of patients complained of poor balance. Clinical evidence of ataxia was seen in 40% patients. Gait, stance and heel-shin slide were the predominant features of cerebellar dysfunction. MRI demonstrated structural, volumetric and functional deficits of the cerebellum. Only one patient with ataxia had phenytoin levels above the normal range. CONCLUSIONS: Cerebellar ataxia is present in 40% of patients with epilepsy and chronic exposure to phenytoin. Patients on long-term phenytoin have reduced cerebellar volume even if they have no clinical evidence of ataxia. Evidence of structural deficits on imaging suggests a predilection for vermian involvement.


Assuntos
Anticonvulsivantes/efeitos adversos , Ataxia , Epilepsia/tratamento farmacológico , Neuroimagem/métodos , Fenitoína/efeitos adversos , Anticorpos/sangue , Ataxia/induzido quimicamente , Ataxia/diagnóstico por imagem , Ataxia/epidemiologia , Encéfalo/diagnóstico por imagem , Encéfalo/efeitos dos fármacos , Epilepsia/sangue , Feminino , Ácido Fólico/sangue , Proteínas de Ligação ao GTP/imunologia , Gliadina/imunologia , Humanos , Estudos Longitudinais , Masculino , Exame Neurológico , Fenitoína/sangue , Proteína 2 Glutamina gama-Glutamiltransferase , Transtornos de Sensação/induzido quimicamente , Transtornos de Sensação/diagnóstico , Transglutaminases/imunologia
7.
Sleep ; 40(8)2017 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-28472425

RESUMO

Objectives: Rapid eye movement (REM) sleep behavior disorder (RBD) is the most specific marker of prodromal alpha-synucleinopathies. We sought to delineate the baseline clinical characteristics of RBD and evaluate risk stratification models. Methods: Clinical assessments were performed in 171 RBD, 296 control, and 119 untreated Parkinson's (PD) participants. Putative risk measures were assessed as predictors of prodromal neurodegeneration, and Movement Disorders Society (MDS) criteria for prodromal PD were applied. Participants were screened for common leucine-rich repeat kinase 2 (LRRK2)/glucocerebrosidase gene (GBA) gene mutations. Results: Compared to controls, participants with RBD had higher rates of solvent exposure, head injury, smoking, obesity, and antidepressant use. GBA mutations were more common in RBD, but no LRRK2 mutations were found. RBD participants performed significantly worse than controls on Unified Parkinson's Disease Rating Scale (UPDRS)-III, timed "get-up-and-go", Flamingo test, Sniffin Sticks, and cognitive tests and had worse measures of constipation, quality of life (QOL), and orthostatic hypotension. For all these measures except UPDRS-III, RBD and PD participants were equally impaired. Depression, anxiety, and apathy were worse in RBD compared to PD participants. Stratification of people with RBD according to antidepressant use, obesity, and age altered the odds ratio (OR) of hyposmia compared to controls from 3.4 to 45.5. 74% (95% confidence interval [CI] 66%, 80%) of RBD participants met the MDS criteria for probable prodromal Parkinson's compared to 0.3% (95% CI 0.009%, 2%) of controls. Conclusions: RBD are impaired across a range of clinical measures consistent with prodromal PD and suggestive of a more severe nonmotor subtype. Clinical risk stratification has the potential to select higher risk patients for neuroprotective interventions.


Assuntos
Doença de Parkinson/complicações , Sintomas Prodrômicos , Transtorno do Comportamento do Sono REM/complicações , Idoso , Antidepressivos/farmacologia , Ansiedade , Apatia , Estudos de Casos e Controles , Depressão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mutação/genética , Obesidade , Doença de Parkinson/genética , Doença de Parkinson/fisiopatologia , Doença de Parkinson/psicologia , Fenótipo , Qualidade de Vida , Transtorno do Comportamento do Sono REM/genética , Transtorno do Comportamento do Sono REM/fisiopatologia , Transtorno do Comportamento do Sono REM/psicologia , Medição de Risco , Fumar
8.
Magn Reson Chem ; 55(5): 414-424, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27657736

RESUMO

NMR diffusion measurements (or dNMR) provide a powerful tool for analysis of solution organization and microgeometry of the environment by probing random molecular motion. Being a very versatile method, dNMR can be applied to a large variety of samples and systems. Here, a brief introduction into dNMR and a summary of recent advances in the field are presented. The research topics include restricted diffusion, anisotropic diffusion, polymer dynamics, solution structuring and dNMR method development. The dNMR studied systems include plants, cells (cell models), liquid crystals, polymer solutions, ionic liquids, supercooled solutions, untreated water, amino acid solutions and more. It is demonstrated how a variety of dNMR methods can be applied to a system to extract the data on particular structures present among, formed by or surrounding the diffusing particles. It is also demonstrated how dNMR methods can be developed to allow probing larger geometries, low sample concentrations and faster processes. Copyright © 2016 John Wiley & Sons, Ltd.

9.
J Vis Exp ; (112)2016 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-27341443

RESUMO

Active Flow Technology (AFT) is a form of column technology that increases the separation performance of a HPLC column through the use of a specially purpose built multiport end-fitting(s). Curtain Flow (CF) columns belong to the AFT suite of columns, specifically the CF column is designed so that the sample is injected into the radial central region of the bed and a curtain flow of mobile phase surrounding the injection of solute prevents the radial dispersion of the sample to the wall. The column functions as an 'infinite diameter' column. The purpose of the design is to overcome the radial heterogeneity of the column bed, and at the same time maximize the sample load into the radial central region of the column bed, which serves to increase detection sensitivity. The protocol described herein outlines the system and CF column set up and the tuning process for an optimized infinite diameter 'virtual' column.


Assuntos
Cromatografia Líquida de Alta Pressão
10.
J Vis Exp ; (110)2016 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-27168419

RESUMO

A protocol for the use of reaction flow high performance liquid chromatography columns for methods employing post column derivatization (PCD) is presented. A major difficulty in adapting PCD to modern HPLC systems and columns is the need for large volume reaction coils that enable reagent mixing and then the derivatization reaction to take place. This large post column dead volume leads to band broadening, which results in a loss of observed separation efficiency and indeed detection in sensitivity. In reaction flow post column derivatization (RF-PCD) the derivatization reagent(s) are pumped against the flow of mobile phase into either one or two of the outer ports of the reaction flow column where it is mixed with column effluent inside a frit housed within the column end fitting. This technique allows for more efficient mixing of the column effluent and derivatization reagent(s) meaning that the volume of the reaction loops can be minimized or even eliminated altogether. It has been found that RF-PCD methods perform better than conventional PCD methods in terms of observed separation efficiency and signal to noise ratio. A further advantage of RF-PCD techniques is the ability to monitor effluent coming from the central port in its underivatized state. RF-PCD has currently been trialed on a relatively small range of post column reactions, however, there is currently no reason to suggest that RF-PCD could not be adapted to any existing one or two component (as long as both reagents are added at the same time) post column derivatization reaction.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos
11.
Sleep ; 39(5): 1051-7, 2016 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-26856903

RESUMO

STUDY OBJECTIVES: An increased risk of narcolepsy has been observed in children following ASO3-adjuvanted pandemic A/H1N1 2009 (Pandemrix) vaccine. We investigated whether this risk extends to adults in England. METHODS: Six adult sleep centers in England were visited between November 2012 and February 2014 and vaccination/clinical histories obtained from general practitioners. Suspected narcolepsy cases aged older than 17 y were selected. The risk of narcolepsy following Pandemrix was calculated using cases diagnosed by the time of the center visits and those with a diagnosis by November 30, 2011 after which there was increased awareness of the risk in children. The odds of vaccination in cases and in matched population data were compared using a case-coverage design. RESULTS: Of 1,446 possible cases identified, most had onset before 2009 or were clearly not narcolepsy. Of the 60 remaining cases, 20 were excluded after expert review, leaving 40 cases with narcolepsy; 5 had received Pandemrix between 3 and 18 mo before onset. All the vaccinated cases had cataplexy, two received a diagnosis by November 2011 and two were aged 40 y or older. The odds ratio for vaccination in cases compared to the population was 4.24 (95% confidence interval 1.45-12.38) using all cases and 9.06 (1.90-43.17) using cases with a diagnosis by November 2011, giving an attributable risk of 0.59 cases per 100,000 doses. CONCLUSIONS: We found a significantly increased risk of narcolepsy in adults following Pandemrix vaccination in England. The risk was lower than that seen in children using a similar study design.


Assuntos
Adjuvantes Imunológicos , Vírus da Influenza A Subtipo H1N1/imunologia , Vacinas contra Influenza/efeitos adversos , Vacinas contra Influenza/imunologia , Influenza Humana/imunologia , Narcolepsia/epidemiologia , Vacinação/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cataplexia/diagnóstico , Cataplexia/epidemiologia , Inglaterra/epidemiologia , Feminino , Humanos , Vacinas contra Influenza/administração & dosagem , Influenza Humana/prevenção & controle , Masculino , Pessoa de Meia-Idade , Narcolepsia/diagnóstico , Razão de Chances , Pandemias , Reprodutibilidade dos Testes , Projetos de Pesquisa , Medição de Risco , Sono , Adulto Jovem
12.
J Vis Exp ; (106): e53448, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26710179

RESUMO

Active flow technology (AFT) is new form of column technology that was designed to overcome flow heterogeneity to increase separation performance in terms of efficiency and sensitivity and to enable multiplexed detection. This form of AFT uses a parallel segmented flow (PSF) column. A PSF column outlet end-fitting consists of 2 or 4 ports, which can be multiplexed to connect up to 4 detectors. The PSF column not only allows a platform for multiplexed detection but also the combination of both destructive and non-destructive detectors, without additional dead volume tubing, simultaneously. The amount of flow through each port can also be adjusted through pressure management to suit the requirements of a specific detector(s). To achieve multiplexed detection using a PSF column there are a number of parameters which can be controlled to ensure optimal separation performance and quality of results; that is tube dimensions for each port, choice of port for each type of detector and flow adjustment. This protocol is intended to show how to use and tune a PSF column functioning in a multiplexed mode of detection.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas , Espectrofotometria Ultravioleta
13.
Anal Chim Acta ; 889: 58-70, 2015 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-26343427

RESUMO

Post Column derivatisation (PCD) coupled with high performance liquid chromatography or ultra-high performance liquid chromatography is a powerful tool in the modern analytical laboratory, or at least it should be. One drawback with PCD techniques is the extra post-column dead volume due to reaction coils used to enable adequate reaction time and the mixing of reagents which causes peak broadening, hence a loss of separation power. This loss of efficiency is counter-productive to modern HPLC technologies, -such as UHPLC. We reviewed 87 PCD methods published from 2009 to 2014. We restricted our review to methods published between 2009 and 2014, because we were interested in the uptake of PCD methods in UHPLC environments. Our review focused on a range of system parameters including: column dimensions, stationary phase and particle size, as well as the geometry of the reaction loop. The most commonly used column in the methods investigated was not in fact a modern UHPLC version with sub-2-micron, (or even sub-3-micron) particles, but rather, work-house columns, such as, 250 × 4.6 mm i.d. columns packed with 5 µm C18 particles. Reaction loops were varied, even within the same type of analysis, but the majority of methods employed loop systems with volumes greater than 500 µL. A second part of this review illustrated briefly the effect of dead volume on column performance. The experiment evaluated the change in resolution and separation efficiency of some weak to moderately retained solutes on a 250 × 4.6 mm i.d. column packed with 5 µm particles. The data showed that reaction loops beyond 100 µL resulted in a very serious loss of performance. Our study concluded that practitioners of PCD methods largely avoid the use of UHPLC-type column formats, so yes, very much, PCD is incompatible with the modern HPLC column.

14.
J Chromatogr A ; 1351: 56-60, 2014 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-24906299

RESUMO

Analytical scale active flow technology first generation silica monolithic columns kitted out in curtain flow mode of operation were studied for the first time. A series of tests were undertaken assessing the column efficiency, peak asymmetry and detection sensitivity. Two curtain flow columns were tested, one with a fixed outlet ratio of 10% through the central exit port, the other with 30%. Tests were carried out using a wide range in inlet flow segmentation ratios. The performance of the curtain flow columns were compared to a conventional monolithic column. The gain in theoretical plates achieved in the curtain flow mode of operation was as much as 130%, with almost Gaussian bands being obtained. Detection sensitivity increased by as much as 250% under optimal detection conditions. The permeability advantage of the monolithic structure together with the active flow technology makes it a priceless tool for high throughput, sensitive, low detection volume analyses.


Assuntos
Cromatografia Líquida/normas , Dióxido de Silício/química , Cromatografia Líquida/instrumentação , Permeabilidade , Sensibilidade e Especificidade
15.
J Sep Sci ; 37(15): 1937-43, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24824418

RESUMO

The synthesis and chromatographic behavior of an analytical size mixed-mode bonded silica monolith was investigated. The monolith was functionalized by an in situ modification process of a bare silica rod with chloro(3-cyanopropyl)dimethyl silane and chlorodimethyl propyl phenyl silane solutions. These ligands were selected in order to combine both resonance and nonresonance π-type bonding within a single separation environment. Selectivity studies were undertaken using n-alkyl benzenes and polycyclic aromatic hydrocarbons in aqueous methanol and acetonitrile mobile phases to assess the methylene and aromatic selectivities of the column. The results fit with the linear solvent strength theory suggesting excellent selectivity of the column was achieved. Comparison studies were performed on monolithic columns that were functionalized separately with cyano and phenyl ligands, suggesting highly conjugated molecules were able to successfully exploit both of the π-type selectivities afforded by the two different ligands on the mixed-mode column.

16.
J Chromatogr A ; 1333: 32-44, 2014 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-24529404

RESUMO

The effects of column length on performance in segmented flow chromatography were tested. Column efficiencies were measured for 4.6mm I.D. 3, 5, 7.5 and 10 cm long columns packed with 3.0 µm Hypurity-C18 fully porous particles and of 4.6mm I.D. 5, 10, 15 and 25 cm long columns packed with 5 µm Hypersil GOLD C18 particles. For each column length and particle type, two different configurations were tested: (1) both the inlet and outlet column endfittings were standard and (2) the inlet endfitting was standard but the outlet endfitting allowed parallel segmentation of the exiting flow into a central and a peripheral coaxial region. The segmentation flow ratio was set at 45% (for 3 µm) and at 43% or 21% (for 5 µm). Four samples were used, naphthalene, toluene, butylbenzene, and insulin, which has a ten times smaller diffusion coefficient than the small molecules. The column performance for the low molecular weight compound is significantly improved at velocities above the optimum value when the outlet flow rate is segmented because longitudinal diffusion and mass transfer resistance of this compound in the stationary phase are negligible sources of band broadening at reduced linear velocities between 5 and 25. At high flow rate (4 mL/min), the long-range eddy dispersion terms are about 3.9, 3.2, 2.6, and 1.8h unit lower for the 3, 5, 7.5 and 10 cm long columns, respectively. The longer the column, the lower the efficiency improvement because the border effects are smaller. This result was not systematically observed for the columns packed with 5 µm particles because the transverse dispersion is larger. In contrast, the gain in column efficiency is marginal for insulin because the mass transfer mechanism of this compound is mostly controlled by the slow diffusivity of insulin across Hypurity-C18 particles.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia em Gel , Cromatografia Líquida de Alta Pressão/instrumentação , Difusão , Insulina/química , Insulina/isolamento & purificação , Peso Molecular , Naftalenos/química , Naftalenos/isolamento & purificação , Porosidade
17.
J Chromatogr A ; 1334: 16-9, 2014 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-24565232

RESUMO

Active flow technology (AFT) columns are designed to minimise inefficient flow processes associated with the column wall and radial heterogeneity of the stationary phase bed. This study is the first to investigate AFT on an analytical scale 4.6mm internal diameter first-generation silica monolith. The performance was compared to a conventional first-generation silica monolith and it was observed that the AFT monolith had an increase in efficiency values that ranged from 15 to 111%; the trend demonstrating efficiency gains increasing as the volumetric flow to the detector was decreased, but with no loss in sensitivity.


Assuntos
Cromatografia Líquida/métodos , Dióxido de Silício/química
18.
Exp Eye Res ; 116: 79-85, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23973715

RESUMO

Tear film stability decreases with age however the cause(s) of the instability are speculative. Perhaps the more saturated meibum from infants may contribute to tear film stability. The meibum lipid phase transition temperature and lipid hydrocarbon chain order at physiological temperature (33 °C) decrease with increasing age. It is reasonable that stronger lipid-lipid interactions could stabilize the tear film since these interactions must be broken for tear break up to occur. In this study, meibum from a pool of adult donors was saturated catalytically. The influence of saturation on meibum hydrocarbon chain order was determined by infrared spectroscopy. Meibum is in an anhydrous state in the meibomian glands and on the surface of the eyelid. The influence of saturation on the surface properties of meibum was determined using Langmuir trough technology. Saturation of native human meibum did not change the minimum or maximum values of hydrocarbon chain order so at temperatures far above or below the phase transition of human meibum, saturation does not play a role in ordering or disordering the lipid hydrocarbon chains. Saturation did increase the phase transition temperature in human meibum by over 20 °C, a relatively high amount. Surface pressure-area studies showing the late take off and higher maximum surface pressure of saturated meibum compared to native meibum suggest that the saturated meibum film is quite molecularly ordered (stiff molecular arrangement) and elastic (molecules are able to rearrange during compression and expansion) compared with native meibum films which are more fluid agreeing with the infrared spectroscopic results of this study. In saturated meibum, the formation of compacted ordered islands of lipids above the surfactant layer would be expected to decrease the rate of evaporation compared to fluid and more loosely packed native meibum. Higher surface pressure observed with films of saturated meibum compared to native meibum suggests greater film stability especially under the high shear stress of a blink.


Assuntos
Lipídeos/análise , Glândulas Tarsais/química , Lágrimas/química , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Espectrofotometria Infravermelho , Propriedades de Superfície , Temperatura
19.
J Sep Sci ; 34(1): 21-6, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21171172

RESUMO

The multidimensional high-performance liquid chromatography separations of the complex sample matrix found in café espresso coffee were completed on the propyl phenyl and butyl phenyl columns that contain 3 and 4 carbon atoms in the spacer chain, respectively. Phenyl type stationary phases are able to undergo unique π-π interactions with aromatic compounds. Previous works have found that there are differences in retention characteristics between these chain lengths and this was explored further here. It was found that when analysing the separations by quadrants, using a geometric approach to factor analysis and by measuring the normalised mean radius, subtle differences in the separations were observed and the butyl phenyl phase was more selective for the high to medium polarity species. However, there was very little difference in separation behaviour for the hydrophobic components within the coffee sample. Overall, the analysis of the entire separation showed very little difference.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Café/química , Elétrons , Hidrocarbonetos Policíclicos Aromáticos/análise , Solventes/química
20.
J Chromatogr A ; 1217(39): 6085-91, 2010 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-20732687

RESUMO

This study investigates the synthesis and chromatographic behaviour of an analytical size cyanopropyl "cyano" bonded silica monolith. Surface modification was undertaken by treating a neat silica monolith with chloro(3-cyanopropyl)dimethyl silane in dry heptane over a two day period. The resulting monolith showed stability over the duration of the testing program that involved flushing the column with more than 2000 column volumes of mobile phase. Efficiency measurements before and after sylation verified that the integrity of the silica monolith itself was not affected by the modification process, the highest number of theoretical plates (N/m) using anisole was 81,650. A brief selectivity test was then undertaken to assess methylene selectivity and phenyl selectivity. Elemental analysis was used to determine the homogeneity of the carbon load throughout the monolithic bed, and was compared to two commercial C18 and one 'self' modified C18 silica monoliths. The development of the in situ modification is also discussed.


Assuntos
Cromatografia de Fase Reversa/métodos , Modelos Químicos , Nitrilas/química , Silanos/química , Dióxido de Silício/química , Anisóis/química , Estabilidade de Medicamentos , Hidrocarbonetos Policíclicos Aromáticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...