Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Can J Anaesth ; 71(1): 8-54, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38253968

RESUMO

OVERVIEW: The Guidelines to the Practice of Anesthesia-Revised Edition 2024 (the Guidelines) were prepared by the Canadian Anesthesiologists' Society (CAS), which reserves the right to determine their publication and distribution. The Guidelines are subject to revision and updated versions are published annually. The Guidelines to the Practice of Anesthesia-Revised Edition 2024 supersede all previously published versions of this document. Although the CAS encourages Canadian anesthesiologists to adhere to its practice guidelines to ensure high-quality patient care, the CAS cannot guarantee any specific patient outcome. Anesthesiologists should exercise their own professional judgement in determining the proper course of action for any patient's circumstances. The CAS assumes no responsibility or liability for any error or omission arising from the use of any information contained in its Guidelines to the Practice of Anesthesia.


RéSUMé: Le Guide d'exercice de l'anesthésie, version révisée 2024 (le Guide), a été préparé par la Société canadienne des anesthésiologistes (SCA), qui se réserve le droit de décider des termes de sa publication et de sa diffusion. Le Guide est soumis à révision et des versions mises à jour sont publiées chaque année. Le Guide d'exercice de l'anesthésie, version révisée 2024, remplace toutes les versions précédemment publiées de ce document. Bien que la SCA incite les anesthésiologistes du Canada à se conformer à son guide d'exercice pour assurer une grande qualité des soins dispensés aux patient·es, elle ne peut garantir les résultats d'une intervention spécifique. Les anesthésiologistes doivent exercer leur jugement professionnel pour déterminer la méthode d'intervention la mieux adaptée à l'état de leur patient·e. La SCA n'accepte aucune responsabilité ou imputabilité de quelque nature que ce soit découlant d'erreurs ou d'omissions ou de l'utilisation des renseignements contenus dans son Guide d'exercice de l'anesthésie.


Assuntos
Anestesia , Anestesiologia , Humanos , Anestesiologistas , Canadá , Qualidade da Assistência à Saúde
4.
Can J Anaesth ; 70(1): 16-55, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36690905

RESUMO

OVERVIEW: The Guidelines to the Practice of Anesthesia Revised Edition 2023 (the Guidelines) were prepared by the Canadian Anesthesiologists' Society (CAS), which reserves the right to determine their publication and distribution. The Guidelines are subject to revision and updated versions are published annually. The Guidelines to the Practice of Anesthesia Revised Edition 2023 supersede all previously published versions of this document. Although the CAS encourages Canadian anesthesiologists to adhere to its practice guidelines to ensure high-quality patient care, the CAS cannot guarantee any specific patient outcome. Anesthesiologists should exercise their own professional judgment in determining the proper course of action for any patient's circumstances. The CAS assumes no responsibility or liability for any error or omission arising from the use of any information contained in its Guidelines to the Practice of Anesthesia.


RéSUMé: Le Guide d'exercice de l'anesthésie, version révisée 2023 (le Guide), a été préparé par la Société canadienne des anesthésiologistes (SCA), qui se réserve le droit de décider des termes de sa publication et de sa diffusion. Le Guide est soumis à révision et des versions mises à jour sont publiées chaque année. Le Guide d'exercice de l'anesthésie, version révisée 2023, remplace toutes les versions précédemment publiées de ce document. Bien que la SCA incite les anesthésiologistes du Canada à se conformer à son guide d'exercice pour assurer une grande qualité des soins dispensés aux patients, elle ne peut garantir les résultats d'une intervention spécifique. Les anesthésiologistes doivent exercer leur jugement professionnel pour déterminer la méthode d'intervention la mieux adaptée à l'état de leur patient. La SCA n'accepte aucune responsabilité ou imputabilité de quelque nature que ce soit découlant d'erreurs ou d'omissions ou de l'utilisation des renseignements contenus dans son Guide d'exercice de l'anesthésie.


Assuntos
Anestesia , Anestesiologia , Humanos , Canadá , Qualidade da Assistência à Saúde , Anestesiologistas
5.
Br J Anaesth ; 129(1): 127-135, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35568510

RESUMO

BACKGROUND: Rebound pain occurs after up to 50% of ambulatory surgeries involving regional anaesthesia. To assist with risk stratification, we developed a model to predict severe rebound pain after foot and ankle surgery involving single-shot popliteal sciatic nerve block. METHODS: After ethics approval, we performed a single-centre retrospective cohort study. Patients undergoing lower limb surgery with popliteal sciatic nerve block from January 2016 to November 2019 were included. Exclusion criteria were uncontrolled pain in the PACU, use of a perineural catheter, or loss to follow-up. We developed and internally validated a multivariable logistic regression model for severe rebound pain, defined as transition from well-controlled pain in the PACU (numerical rating scale [NRS] 3 or less) to severe pain (NRS ≥7) within 48 h. A priori predictors were age, sex, surgery type, planned admission, local anaesthetic type, dexamethasone use, and intraoperative anaesthesia type. Model performance was evaluated using area under the receiver operating characteristic curve (AUROC), Nagelkerke's R2, scaled Brier score, and calibration slope. RESULTS: The cohort included 1365 patients (mean [standard deviation] age: 50 [16] yr). The primary outcome was abstracted in 1311 (96%) patients, with severe rebound pain in 652 (50%). Internal validation revealed poor model performance, with AUROC 0.632 (95% confidence interval [CI]: 0.602-0.661; bootstrap optimisation 0.021), Nagelkerke's R2 0.063, and scaled Brier score 0.047. Calibration slope was 0.832 (95% CI: 0.623-1.041). CONCLUSIONS: We show that a multivariable risk prediction model developed using routinely collected clinical data had poor predictive performance for severe rebound pain after foot and ankle surgery. Prospective studies involving other patient-related predictors are needed. CLINICAL TRIAL REGISTRATION: NCT05018104.


Assuntos
Anestesia por Condução , Bloqueio Nervoso , Tornozelo/cirurgia , Humanos , Extremidade Inferior , Pessoa de Meia-Idade , Bloqueio Nervoso/efeitos adversos , Medição da Dor , Dor Pós-Operatória/etiologia , Estudos Prospectivos , Estudos Retrospectivos , Nervo Isquiático
7.
Can J Anaesth ; 68(9): 1358-1367, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33973161

RESUMO

PURPOSE: Novel devices such as the barrier enclosure were developed in hopes of improving provider safety by limiting SARS-CoV-2 transmission during tracheal intubation. Nevertheless, concerns arose regarding a lack of rigorous efficacy and safety data for these devices. We conducted a randomized controlled trial to evaluate the impact of the barrier enclosure on time to tracheal intubation. METHOD: After Research Ethics Board approval, elective surgical patients with normal airway predictors were randomly allocated 1:1 to tracheal intubation with or without a barrier enclosure. The primary outcome was time to tracheal intubation. Secondary outcomes included first-pass success rate, total time of airway manipulation, anesthesiologists' perception of intubation difficulty, likelihood of use in SARS-CoV-2-positive patients, and patients' perception of comfort and acceptability. RESULTS: There were 48 participants in the barrier enclosure group and 46 participants in the control group. The mean (standard deviation [SD]) time to tracheal intubation was 62 (29) sec with barrier closure and 53 (27) sec without barrier enclosure (mean difference, 9 sec; 95% confidence interval, - 3 to 20; P = 0.14). Anesthesiologists rated the difficulty of intubation higher with barrier enclosure (mean [SD] visual analogue scale score, 27 [26] mm vs 9 [17] mm; P < 0.001). There were no significant differences in other secondary outcomes. CONCLUSION: In healthy surgical patients with normal airway predictors, the use of a barrier enclosure during tracheal intubation did not significantly prolong time to intubation or decrease first-pass intubation success. Nevertheless, there was an increase in difficulty of intubation perceived by the anesthesiologists with use of a barrier enclosure. TRIAL REGISTRATION: www.clinicaltrials.gov (NCT04366141); registered 28 April 2020.


RéSUMé: OBJECTIF: De nouveaux dispositifs tels que des boîtes de protection ont été mis au point dans l'espoir d'améliorer la sécurité des fournisseurs de soins en limitant la transmission du SRAS-CoV-2 pendant l'intubation endotrachéale. Néanmoins, des inquiétudes ont été soulevées au sujet d'un manque de données rigoureuses sur l'efficacité et l'innocuité de ces dispositifs. Nous avons réalisé une étude randomisée contrôlée afin d'évaluer l'impact d'une boîte de protection sur le temps de l'intubation endotrachéale. MéTHODE: Après avoir reçu l'approbation du Comité d'éthique de la recherche, des patients de chirurgie élective présentant des prédicteurs des voies aériennes normales ont été aléatoirement répartis à un ratio de 1:1 pour une intubation endotrachéale avec ou sans boîte de protection. Le critère d'évaluation principal était le temps nécessaire à l'intubation endotrachéale. Les critères d'évaluation secondaires comprenaient le taux de réussite à la première tentative, le temps total de manipulation des voies aériennes, la perception par les anesthésiologistes de la difficulté d'intubation, la probabilité d'utilisation chez les patients atteints du SRAS-CoV-2, et la perception de confort et d'acceptabilité des patients. RéSULTATS: Il y avait 48 participants dans le groupe avec boîte et 46 participants dans le groupe témoin. Le temps moyen (écart type [ÉT]) pour l'intubation endotrachéale était de 62 (29) sec avec la boîte et de 53 (27) sec sans la boîte (différence moyenne, 9 sec; intervalle de confiance de 95 %, − 3 à 20; P = 0,14). Les anesthésiologistes ont estimé que la difficulté d'intubation était plus élevée avec une boîte de protection (score moyen sur l'échelle visuelle analogique [ÉT], 27 [26] mm vs 9 [17] mm; P < 0,001). Il n'y avait pas de différences pour les autres critères d'évaluation secondaires. CONCLUSION: Chez les patients chirurgicaux en bonne santé avec des prédicteurs de voies aériennes normales, l'utilisation d'une boîte de protection pendant l'intubation endotrachéale n'a pas prolongé de manière significative le temps d'intubation ni réduit le taux de réussite de l'intubation à la première tentative. Néanmoins, il y avait une augmentation de la difficulté d'intubation perçue par les anesthésiologistes avec l'utilisation d'une boîte de protection. ENREGISTREMENT DE L'éTUDE: www.clinicaltrials.gov (NCT04366141); enregistrée le 28 avril 2020.


Assuntos
COVID-19 , Anestesiologistas , Humanos , Intubação Intratraqueal , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...