Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Access Microbiol ; 6(2)2024.
Artigo em Inglês | MEDLINE | ID: mdl-38482357

RESUMO

Severe acute respiratory syndrome (SARS) coronavirus 2 (SARS-CoV-2) is a novel human coronavirus that was identified in 2019. SARS-CoV-2 infection results in an acute, severe respiratory disease called coronavirus disease 2019 (COVID-19). The emergence and rapid spread of SARS-CoV-2 has led to a global public health crisis, which continues to affect populations across the globe. Real time reverse transcription polymerase chain reaction (rRT-PCR) is the reference standard test for COVID-19 diagnosis. Serological tests are valuable tools for serosurveillance programs and establishing correlates of protection from disease. This study evaluated the performance of one in-house enzyme linked immunosorbent assay (ELISA) utilizing the pre-fusion stabilized ectodomain of SARS-CoV-2 spike (S), two commercially available chemiluminescence assays Ortho VITROS Immunodiagnostic Products Anti-SARS-CoV-2 Total Reagent Pack and Abbott SARS-CoV-2 IgG assay and one commercially available Surrogate Virus Neutralization Test (sVNT), GenScript USA Inc., cPass SARS-CoV-2 Neutralization Antibody Detection Kit for the detection of SARS-CoV-2 specific antibodies. Using a panel of rRT-PCR confirmed COVID-19 patients' sera and a negative control group as a reference standard, all three immunoassays demonstrated high comparable positivity rates and low discordant rates. All three immunoassays were highly sensitive with estimated sensitivities ranging from 95.4-96.6 %. ROC curve analysis indicated that all three immunoassays had high diagnostic accuracies with area under the curve (AUC) values ranging from 0.9698 to 0.9807. High positive correlation was demonstrated among the conventional microneutralization test (MNT) titers and the sVNT inhibition percent values. Our study indicates that independent evaluations are necessary to optimize the overall utility and the interpretation of the results of serological tests. Overall, we demonstrate that all serological tests evaluated in this study are suitable for the detection of SARS-CoV-2 antibodies.

2.
Clin Infect Dis ; 73(10): 1831-1839, 2021 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-33639620

RESUMO

BACKGROUND: Monitoring of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody prevalence can complement case reporting to inform more accurate estimates of SARS-CoV-2 infection burden, but few studies have undertaken repeated sampling over time on a broad geographic scale. METHODS: We performed serologic testing on a convenience sample of residual serum obtained from persons of all ages, at 10 sites in the United States from 23 March through 14 August 2020, from routine clinical testing at commercial laboratories. We standardized our seroprevalence rates by age and sex, using census population projections and adjusted for laboratory assay performance. Confidence intervals were generated with a 2-stage bootstrap. We used bayesian modeling to test whether seroprevalence changes over time were statistically significant. RESULTS: Seroprevalence remained below 10% at all sites except New York and Florida, where it reached 23.2% and 13.3%, respectively. Statistically significant increases in seroprevalence followed peaks in reported cases in New York, South Florida, Utah, Missouri, and Louisiana. In the absence of such peaks, some significant decreases were observed over time in New York, Missouri, Utah, and Western Washington. The estimated cumulative number of infections with detectable antibody response continued to exceed reported cases in all sites. CONCLUSIONS: Estimated seroprevalence was low in most sites, indicating that most people in the United States had not been infected with SARS-CoV-2 as of July 2020. The majority of infections are likely not reported. Decreases in seroprevalence may be related to changes in healthcare-seeking behavior, or evidence of waning of detectable anti-SARS-CoV-2 antibody levels at the population level. Thus, seroprevalence estimates may underestimate the cumulative incidence of infection.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Teorema de Bayes , Criança , Humanos , Estudos Soroepidemiológicos , Estados Unidos/epidemiologia , Utah
3.
Clin Infect Dis ; 72(12): e1004-e1009, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-33252659

RESUMO

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus that causes coronavirus disease 2019 (COVID-19), was first identified in Wuhan, China, in December 2019, with subsequent worldwide spread. The first US cases were identified in January 2020. METHODS: To determine if SARS-CoV-2-reactive antibodies were present in sera prior to the first identified case in the United States on 19 January 2020, residual archived samples from 7389 routine blood donations collected by the American Red Cross from 13 December 2019 to 17 January 2020 from donors resident in 9 states (California, Connecticut, Iowa, Massachusetts, Michigan, Oregon, Rhode Island, Washington, and Wisconsin) were tested at the Centers for Disease Control and Prevention for anti-SARS-CoV-2 antibodies. Specimens reactive by pan-immunoglobulin (pan-Ig) enzyme-linked immunosorbent assay (ELISA) against the full spike protein were tested by IgG and IgM ELISAs, microneutralization test, Ortho total Ig S1 ELISA, and receptor-binding domain/ACE2 blocking activity assay. RESULTS: Of the 7389 samples, 106 were reactive by pan-Ig. Of these 106 specimens, 90 were available for further testing. Eighty-four of 90 had neutralizing activity, 1 had S1 binding activity, and 1 had receptor-binding domain/ACE2 blocking activity >50%, suggesting the presence of anti-SARS-CoV-2-reactive antibodies. Donations with reactivity occurred in all 9 states. CONCLUSIONS: These findings suggest that SARS-CoV-2 may have been introduced into the United States prior to 19 January 2020.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Doadores de Sangue , China , Connecticut , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoglobulina G , Iowa , Massachusetts , Michigan , Oregon , Rhode Island , Glicoproteína da Espícula de Coronavírus , Washington , Wisconsin
4.
Clin Infect Dis ; 73(9): e3120-e3123, 2021 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-33300579

RESUMO

We compared severe acute respiratory syndrome coronavirus 2 seroprevalence estimated from commercial laboratory residual sera and a community household survey in metropolitan Atlanta during April and May 2020 and found these 2 estimates to be similar (4.94% vs 3.18%). Compared with more representative surveys, commercial sera can provide an approximate measure of seroprevalence.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Humanos , Laboratórios , Estudos Soroepidemiológicos , Inquéritos e Questionários
5.
Biologicals ; 57: 9-20, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30458978

RESUMO

Despite wide spread vaccination, the public health burden of pertussis remains substantial. Current acellular pertussis vaccines comprise upto five Bordetella pertussis (Bp) antigens. Performing an ELISA to quantify antibody for each antigen is laborious and challenging to apply to pediatric samples where serum volume may be limited. We developed a microsphere based multiplex antibody capture assay (MMACA) to quantify antibodies to five pertussis antigens; pertussis toxin, pertactin, filamentous hemagglutinin and fimbrial antigens 2/3, and adenylate cyclase toxin in a single reaction (5-plex) with a calibrated reference standard, QC reagents and SAS® based data analysis program. The goodness of fit (R2) of the standard curves for five analytes was ≥0.99, LLOQ 0.04-0.15 IU or AU/mL, accuracy 1.9%-23.8% (%E), dilutional linearity slopes 0.93-1.02 and regression coefficients r2 = 0.91-0.99. MMACA had acceptable precision within a median CV of 16.0%-22.8%. Critical reagents, antigen conjugated microsphere and reporter antibody exhibited acceptable (<12.3%) lot-lot variation. MMACA can be completed in <3 h, requires low serum volume (5µL/multiplex assay) and has fast data turnaround time (<1 min). MMACA has been successfully developed and validated as a sensitive, specific, robust and rugged method suitable for simultaneous quantification of anti-Bp antibodies in serum, plasma and DBS.


Assuntos
Anticorpos Antibacterianos/imunologia , Antígenos de Bactérias/imunologia , Bordetella pertussis/imunologia , Toxina Pertussis/imunologia , Testes Sorológicos/métodos , Anticorpos Antibacterianos/sangue , Proteínas da Membrana Bacteriana Externa/imunologia , Humanos , Reprodutibilidade dos Testes , Fatores de Virulência de Bordetella/imunologia
6.
J Immunol Methods ; 333(1-2): 89-106, 2008 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-18304568

RESUMO

Quantification of anthrax lethal toxin (LTx) neutralization activity (TNA) is pivotal in assessing protective antibody responses to anthrax vaccines and for evaluation of immunotherapies for anthrax. We have adapted and redesigned the TNA assay to establish a unifying, standardized, quantitative and validated technology platform for LTx neutralization in the J774A.1 murine cell line. Critical design features of this platform are 1) the application of a free-form or constrained 4 parameter logistic (4-PL) function to model neutralization responses within and between boundary limits of 100% cell survival and 95% cell lysis and 2) to exploit innovative assay curve recognition algorithms for interpretive endpoints. The assay was validated using human serum ED50 (dilution of serum effecting 50% neutralization) as the primary reportable value (RV). Intra-operator and intermediate precision, expressed as the coefficient of variation (%CV), were high at 10.5-15.5%CV and 13.5-14.5%CV respectively. TNA assay dilutional linearity was demonstrated for human sera using linear regression analysis of log(10) transformed data with slope=0.99, intercept=-0.03 and r(2)=0.985. Assay accuracy, inferred from the precision and linearity data and using a spike-recovery approach, was high with a percent error (%E) range of only 3.4-20.5%E. The lower limit of detection (LLOD) was ED50=12 and the lower limit of quantification (LLOQ) was ED50=36. The cell-based assay was robust, tolerating incubation temperatures from 35 to 39 degrees C, CO(2) concentrations from 3% to 7% and reporter substrate (MTT) concentrations of 2.5-7.5 mg/ml. Strict assay quality control parameters were met for up to 25 cell culture passages. The long term (50 month) assay stability, determined using human reference standards AVR414 and AVR801, indicated high precision, consistent accuracy and no detectable assay drift. A customized software program provided two additional assay metrics, Quantification Titer (QT) and Threshold Titer (TT), both of which demonstrate acceptable accuracy, precision and dilutional linearity. The TT was also used to establish the assay reactivity threshold (RT). The application of the assay to sera from humans, Rhesus macaques and rabbits was demonstrated separately and by aggregate dilutional linearity analysis of the ED50 (slope=0.98, intercept=0.003, r(2)=0.989). We propose this TNA assay format with a qualified standard reference serum and customized interpretive software as a unifying platform technology for determination of functional serologic responses to anthrax vaccines and for evaluation of anthrax immunotherapeutics.


Assuntos
Antraz/imunologia , Anticorpos Antibacterianos/imunologia , Antígenos de Bactérias/imunologia , Bacillus anthracis/imunologia , Toxinas Bacterianas/imunologia , Modelos Imunológicos , Testes de Neutralização/métodos , Animais , Antraz/prevenção & controle , Vacinas contra Antraz/imunologia , Linhagem Celular , Humanos , Macaca mulatta , Camundongos , Coelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...