Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Clin Radiol ; 70(11): 1244-51, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26231468

RESUMO

AIM: To investigate the value of advanced virtual monoenergetic image reconstruction (mono-plus) from dual-energy computed tomography (CT) for improving the contrast of CT pulmonary angiography (CTPA). MATERIALS AND METHODS: Forty consecutive patients (25 women, mean 62.5 years, range 28-87 years) underwent 192-section dual-source CTPA with dual-energy CT (90/150 SnkVp) after the administration of 60 ml contrast media (300 mg iodine/ml). Conventional virtual monochromatic images at 60 keV and 17 mono-plus image datasets from 40-190 keV (in 10 keV steps) were reconstructed. Subjective image quality (artefacts, subjective noise) was rated. Attenuation was measured in the pulmonary trunk and in the right lower lobe pulmonary artery; noise was measured in the periscapular musculature. The signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated for each patient and dataset. Comparisons between monochromatic images and mono-plus images were performed by repeated measures analysis of variance (ANOVA) with post-hoc Bonferroni correction. RESULTS: Interreader agreement was good to excellent for subjective image quality (ICC: 0.616-0.889). As compared to conventional 60 keV images, artefacts occurred less (p=0.001) and subjective noise was rated lower (p<0.001) in mono-plus 40 keV images. Noise was lower (p<0.001), and the SNR and CNR in the pulmonary trunk and right lower lobe pulmonary artery were higher (both, p<0.001) in mono-plus 40 keV images compared to conventional monoenergetic 60 keV images. Transient interruption of contrast (TIC) was found in 14/40 (35%) of patients, with subjective contrast being similar 8/40 (20%) or higher 32/40 (80%) in mono-plus 40 keV as compared to conventional monoenergetic 60 keV images. CONCLUSIONS: Compared to conventional virtual monoenergetic imaging, mono-plus images at 40 keV improve the contrast of dual-energy CTPA.


Assuntos
Processamento de Imagem Assistida por Computador/normas , Artéria Pulmonar/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Artefatos , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Iodo , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/normas , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas
2.
Clin Radiol ; 69(12): e497-504, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25239788

RESUMO

AIM: To determine qualitative and quantitative image-quality parameters in abdominal imaging using advanced modelled iterative reconstruction (ADMIRE) with third-generation dual-source 192 section CT. MATERIALS AND METHODS: Forty patients undergoing abdominal portal-venous CT at different tube voltage levels (90, 100, 110, and 120 kVp, n = 10 each) and 10 consecutive patients undergoing abdominal non-enhanced low-dose CT (100 kVp, 60 mAs) using a third-generation dual-source 192 section CT machine in the single-source mode were included. Images were reconstructed with filtered back projection (FBP) and ADMIRE (strength levels 1-5). Two blinded, independent readers subjectively determined image noise, artefacts, visibility of small structures, and image contrast, and measured attenuation in the liver, spleen, kidney, muscle, fat, and urinary bladder, and objective image noise. RESULTS: Subjective noise was significantly lower and image contrast significantly higher for each increasing ADMIRE strength level and also for ADMIRE 1 compared to FBP (all, p < 0.001). No significant differences were found for artefact and visibility ratings among image sets (all, p > 0.05). Attenuation was similar across tube voltage-image datasets in all anatomical regions (all, p > 0.05). Objective noise was significantly lower for each increasing ADMIRE strength level, and for ADMIRE 1 compared to FBP (all, p < 0.001, maximal reduction 53%). Independent predictors of noise were tube voltage (p < 0.05) and current (p < 0.001), diameter (p < 0.05), and reconstruction algorithm (p<0.001); the amount of noise reduction was related only to the reconstruction algorithm (p < 0.001). CONCLUSION: Abdominal CT using ADMIRE results in an improved image quality with lower image noise as compared with FBP, while the attenuation of various anatomical regions remains constant among reconstruction algorithms.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Meios de Contraste , Estudos de Avaliação como Assunto , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
Clin Neurol Neurosurg ; 114(6): 668-72, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22300889

RESUMO

BACKGROUND: The aim of this study was to evaluate surgical outcome of unruptured intracranial aneurysms (UIAs) in a low-volume hospital and compare the results with the recent literature. METHODS: A retrospective review of all consecutive craniotomies for UIA from July 1999 through June 2009 was performed. Morbidity was defined as modified Rankin Scale (mRS) ≥ 3 and evaluated six weeks after surgery. Cognitive function was evaluated at rehabilitation-to-home discharge. A PubMed database search (2001-2011) seeking retrospective, single-center studies reporting on surgical outcome of UIAs was performed. RESULTS: There were 47 procedures performed in 42 patients to treat 50 UIAs (mean of 5 annual craniotomies). The mean age was 54.7 ± 12.1 years and mean aneurysm size was 7.6 ± 4.0mm. Favorable outcome (mRS 0-2) at six weeks after surgery was achieved in 45 of 47 procedures (95.7%). Aneurysm size ≥ 12 mm was statistically significant related to adverse outcome defined as mRS change ≥ 1 (71% vs. 29%; p = 0.018). Five patients (10.6%) with favorable neurological outcome (mRS 2) presented with cognitive impairment at rehabilitation-to-home discharge. There was no significant difference in overall morbidity and mortality comparing low- and high-volume hospitals (4.0% vs. 4.8%; p = 0.85). CONCLUSIONS: Low-volume hospitals may achieve good results for surgical treatment of UIAs. The results indicate that defining numeric operative volume thresholds is not feasible to guide centralization of aneurysm treatment.


Assuntos
Aneurisma Intracraniano/cirurgia , Procedimentos Neurocirúrgicos/métodos , Adulto , Idoso , Atenção/fisiologia , Transtornos Cognitivos/etiologia , Transtornos Cognitivos/reabilitação , Função Executiva , Feminino , Hospitais , Humanos , Masculino , Memória/fisiologia , Pessoa de Meia-Idade , Testes Neuropsicológicos , Artéria Cerebral Posterior/patologia , Artéria Cerebral Posterior/cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento , Percepção Visual/fisiologia
4.
Br J Radiol ; 82(980): 649-53, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19221184

RESUMO

The aim of the study was to determine the impact of vessel attenuation on quantitative 64-slice computed tomography coronary angiography (CTCA). CTCA and invasive quantitative coronary angiography (QCA) were performed in 100 consecutive patients (42 women, 58 men; mean age 64.4+/-9.4 years; age range 39-87 years). In QCA, stenoses were quantified with dedicated software, whereas in CTCA, stenosis severity was assessed with an electronic caliper tool: stenoses were graded in 10% steps and assigned as either a calcified or non-calcified lesion. Vessel attenuation in the left main (LMA) and the proximal right coronary artery (RCA) were measured and correlated with differences in quantifications of stenosis grade between QCA and CTCA. A total of 113 coronary stenoses were detected by both methods (94 significant and 19 non-significant); 52 stenoses were rated as non-calcified and 61 as calcified lesions. The mean difference between QCA and quantitative CTCA grading was 5.1+/-16.9% (range -27 to 46%) overall; 1.9+/-14.2% (range -27 to 38%) for non-calcified lesions and 7.8+/-18.6% (range -23 to 46%) for calcified lesions. Mean vessel attenuation was 362+/-76 HU (range 191-584 HU) in the LMA and 333+/-81 HU (range 162-564 HU) in the RCA. Attenuation did not significantly correlate with differences in QCA and CTCA gradings, neither overall nor for calcified or non-calcified lesions. When 64-slice CTCA is used, coronary vessel attenuation had no impact on the quantitative grading of stenoses.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Vasos Coronários , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estenose Coronária/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
5.
Heart ; 94(9): 1132-7, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18519548

RESUMO

OBJECTIVE: To investigate the performance of low-dose, dual-source computed tomography (DSCT) coronary angiography in the step-and-shoot (SAS) mode for the diagnosis of significant coronary artery stenoses in comparison with conventional coronary angiography (CCA). DESIGN, SETTING AND PATIENTS: Prospective, single-centre study conducted in a referral centre enrolling 120 patients (71 men, mean (SD) age 68 (9) years, mean (SD) body mass index 26.2 (3.2) kg/m2). All study participants underwent DSCT in the SAS mode and CCA within 14 days. Twenty-seven patients were given intravenous beta blockers for heart rate reduction before CT. Patients were excluded if a target heart rate 50%) stenoses. Sensitivity, specificity, negative (NPV) and positive predictive values (PPV) were determined, with CCA being the standard of reference. Radiation dose values were calculated. RESULTS: DSCT coronary angiography in the SAS mode was successfully performed in all 120 patients. Mean (SD) heart rate during scanning was 59 (6) bpm (range 44-69). 1773/1803 coronary segments (98%) were depicted with a diagnostic image quality in 109/120 patients (91%). The overall patient-based sensitivity, specificity, PPV and NPV for the diagnosis of significant stenoses were 100%, 93%, 94% and 100%, respectively. The mean (SD) effective dose of the CT protocol was 2.5 (0.8) mSv (range 1.2-4.4). CONCLUSIONS: DSCT coronary angiography in the SAS mode allows, in selected patients with a regular heart rate, the accurate diagnosis of significant coronary stenoses at a low radiation dose.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Meios de Contraste , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade , Estatísticas não Paramétricas
6.
Heart ; 94(9): 1154-61, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18032458

RESUMO

OBJECTIVE: To prospectively investigate the diagnostic accuracy of dual-source 64-slice computed tomography coronary angiography (CTCA), calcium scoring (CS) and both methods combined for assessing significant coronary artery stenoses relative to conventional coronary angiography (CCA). DESIGN, SETTING AND PATIENTS: Prospective, single-centre study conducted in a referral centre enrolling 74 consecutive patients (24 women; mean age 62 (SD 12) years) from August-October 2006. All study participants underwent CS, CTCA and CCA. Diagnostic accuracy was calculated for CS, CTCA and both methods combined relative to CCA. Not-evaluative segments at computed tomography were considered false positive. RESULTS: CCA identified 139 stenoses in 36 patients. Average heart rate during CTCA was 68 (13) bpm (range 35-102 bpm), and 2% of segments (21/1001) in 11% of patients (8/74) were not evaluative. Considering these as false positives, per-patient sensitivity and specificity was 98% and 87%. When using CS cut-off values of 0 to exclude and >or=400 to predict stenosis, sensitivity and specificity of CS was 100% and 70%, respectively. Combining CS and CTCA in all patients correctly reclassified five patients, while six were falsely classified as stenotic, all of them correctly classified with CTCA alone. Using CS only in patients with not-evaluative segments correctly reclassified five patients while avoiding misclassifications (sensitivity 98%, specificity 100%). CONCLUSION: Dual-source CTCA allows the diagnosis of significant stenoses with a high diagnostic accuracy. Selectively combining CS with CTCA in patients with not-evaluative coronary segments improves specificity from 87% to 100% without decreasing the high sensitivity of 98%.


Assuntos
Calcinose/diagnóstico , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Idoso , Calcinose/complicações , Doença da Artéria Coronariana/complicações , Vasos Coronários/patologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade
7.
Rofo ; 178(10): 1007-13, 2006 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-16894497

RESUMO

PURPOSE: To evaluate the influence of the body mass index (BMI) on coronary artery opacification in 64-slice CT. MATERIAL AND METHODS: Sixty-two patients retrospectively underwent ECG-gated 64-slice CT coronary angiography (tube potential 120 kV, tube current time product 650 mAs) after intravenous injection of 80 ml of iodinated contrast agent (320 mg/ml, 5 ml/s). Attenuation values (HU) were measured and contrast-to-noise ratios (CNR) were calculated in the right coronary artery (RCA) and left main artery (LMA). The CNR was defined as the difference between the mean attenuation in the vessel and the mean attenuation in the perivascular fat tissue divided by the image noise in the ascending aorta. The height and weight of the patients at the time of the CT scan were recorded and the BMI was calculated. RESULTS: The mean BMI was 26.2 +/- 3.2 kg/m (2) (range 19.7 - 32.2 kg/m (2)), the mean attenuation in the LMA was 330 +/- 64 HU, and the mean attenuation in the RCA was 309 +/- 68 HU. The CNR in the LMA was 16.7 +/- 3.8, and the CNR in the RCA was 15.9 +/- 3.6. The image noise in the ascending aorta significantly correlated with the BMI (r = 0.36, p < 0.01). A weak negative correlation was found between the BMI and LMA attenuation (r = - 0.28, p < 0.05), whereas no significant correlation was found for the RCA (r = - 0.21, p = 0.12). A significant negative correlation was found between the BMI and the CNR in the RCA (r = - 0.41, p < 0.05) and the LMA (r = - 0.47, p < 0.001). CONCLUSION: With constant scan parameters and a constant contrast medium amount, the CNR in both coronary arteries decreases while the BMI increases. This implies a modification of previously standardized and fixed examinations with respect to individually adapted protocols with variable parameters for CT coronary angiography.


Assuntos
Índice de Massa Corporal , Meios de Contraste , Angiografia Coronária/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Valores de Referência , Estudos Retrospectivos , Estatística como Assunto
8.
Rofo ; 176(4): 529-37, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15088177

RESUMO

PURPOSE: To evaluate the time-effectiveness, inter-observer variance, and accuracy of left ventricular ejection fraction (EF) measurements using retrospectively ECG-gated four-channel multi-detector row CT (MDCT) angiography in comparison with biplane cine-ventriculography. MATERIALS AND METHODS: Twenty consecutive patients underwent retrospectively ECG-gated MDCT angiography and conventional coronary angiography with biplane ventriculography. Raw MDCT data were reconstructed at 0 % - 90 % of the cardiac cycle in increments of 10 %. Ten geometrically identical multiplanar reformations parallel to the short axis of the heart were reconstructed in each patient. Three blinded readers segmented the left ventricle in the end-systolic and end-diastolic phase using standardized window settings in order to determine the EF. The EF was measured with biplane cine-ventriculography by two blinded readers and was compared with MDCT. The time needed for post-processing was recorded and the inter-observer agreement for both imaging techniques was assessed. RESULTS: Mean post-processing time was 63 +/- 3 min per patient for MDCT and 5.5 +/- 1.2 min for ventriculography. MDCT and ventriculography showed a good correlation (r = 0.83, p < 0.0001) for measurement of the EF. Mean errors of EF measurements for the three MDCT readers compared with the mean of the ventriculography were - 6.3 +/- 6.6 %, - 4.7 +/- 7.1 % and - 4.6 +/- 5.7 %, respectively. The mean differences between the three readers assessing MDCT were - 1.6 +/- 3.2 % (reader 1 versus 2, r = 0.96), - 1.6 +/- 5.6 % (1 versus 3, r = 0.95) and - 0.011 +/- 2.9 % (2 versus 3, r = 0.97, p < 0.0001). The mean differences between the two readers assessing ventriculography was 0.32 +/- 5.1 % (r = 0.88, p < 0.0001). CONCLUSIONS: MDCT correlates well with biplane cine-ventriculography but has the tendency to underestimate the left ventricular EF. Measurements using MDCT have a high inter-observer agreement, however, the time needed for additional MDCT data post-processing is still unacceptably long.


Assuntos
Angiografia/métodos , Volume Sistólico , Tomografia Computadorizada por Raios X/métodos , Função Ventricular Esquerda , Idoso , Algoritmos , Angiografia Coronária , Eletrocardiografia , Feminino , Previsões , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos , Fatores de Tempo
9.
Rofo ; 176(4): 556-63, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15088181

RESUMO

PURPOSE: To evaluate the impact of different iodine concentrations of intravenous contrast agent on hepatic and vascular enhancement during arterial and porto-venous phase imaging using a 4-channel multi-detector row CT (MDCT). MATERIAL AND METHODS: One hundred consecutive patients referred for triphasic abdominal MDCT were randomly assigned into four groups receiving different iodine concentration (200, 250, 300 or 350 mg/ml). Non-contrast, arterial, and porto-venous phase 4-channel MDCT imaging was performed (VolumeZoom, Siemens, Germany). A fixed volume of 150 ml intravenous contrast agent at a rate of 3 ml/s was injected using an automatic bolus-tracking system (Care Bolus, Siemens, Erlangen). Hepatic and vascular enhancement values were measured over time and non-contrast values were subtracted in order to compute arterial and porto-venous mean hepatic (MHE) and mean aortic (MAE) enhancement for each group. Mean change of enhancement > 80 HU for the aorta and > 40 HU for the liver during porto-venous phase imaging was considered as sufficient enhancement. RESULTS: All groups achieved sufficient vascular enhancement during arterial phase imaging; MAE with 350 mg/ml (222 HU) and 300 mg/ml (213HU) was significantly better than with 250 mg (196HU) and 200 mg/ml (169 HU), whereas MHE showed no statistically significant difference between the groups (range 16 - 25 HU). Porto-venous MHE showed increased enhancement with larger concentrations, with significant differences among the groups. Only the higher concentration groups (350 mg/ml und 300 mg/ml) fulfilled in every individual the guidelines for sufficient porto-venous MHE. In the lower concentration groups, 8 patients with 200 mg/ml and 3 patients with 250 mg/ml showed enhancement values below the required minimum. CONCLUSION: A decrease in iodine contrast agent down to 200 mg/ml concentration is only tenable for propose of vascular aortic and hepatic arterial enhancement, whereas hepatic porto-venous phase imaging still requires concentrations at or above the level of 300 mg/ml.


Assuntos
Aortografia , Meios de Contraste/administração & dosagem , Iodo/administração & dosagem , Fígado/diagnóstico por imagem , Radiografia Abdominal , Tomografia Computadorizada por Raios X/métodos , Ácidos Tri-Iodobenzoicos/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Aortografia/métodos , Interpretação Estatística de Dados , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia Abdominal/métodos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA