Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anesth Essays Res ; 10(3): 637-642, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27746565

RESUMO

BACKGROUND: Spinal anesthesia is a preferred technique over general anesthesia for cesarean delivery. It avoids maternal airway related complications, aspiration and neonatal depression. However hypotension following spinal anesthesia can lead to decrease in uterine blood flow and neonatal hypoxia. AIMS: We aimed to evaluate the efficacy of 15 mL.kg- 1of crystalloid preloading versus prophylactic intravenous bolus of 10 mg ephedrine as an antihypotensive measure for cesarean section. METHODS: A prospective randomized double blind study was conducted in hundred ASA grade I/II parturient undergoing cesarean section, allocated to group P (n=50) who received preloading with ringer lactate 15 mL.kg- 1 over 20 minutes before spinal anesthesia and group E (n=50) received intravenous bolus of 10mg ephedrine within one minute of spinal anesthesia with 10mg of hyperbaric bupivacaine 0.5% at L2-3/L3-4 level. They were monitored for incidences of hypotension, need of rescue doses of ephedrine, Apgar score and adverse events. Appropriate statistical tests were applied and P < 0.05 was considered as significant. RESULTS: Incidence of hypotension within 20 minutes of spinal anesthesia was significantly less in group E (28%) as compared to group P (58%) and need of rescue doses were more in group P. Adverse events like nausea vomiting and shivering were less in group E. Apgar score were better in group E than in group P delivered babies. CONCLUSION: Prophylactic intravenous bolus of 10mg ephedrine with spinal injection is more effective in maintaining maternal hemodynamic stability and better neonatal outcome as compared to crystalloid preloading during cesarean delivery.

2.
J Anaesthesiol Clin Pharmacol ; 30(2): 238-42, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24803765

RESUMO

BACKGROUND: Recently introduced ropivacaine is 40% less potent than bupivacaine. Ropivacaine made hyperbaric by the addition of dextrose is known to provide reliable spinal anesthesia (SA). This study was designed to compare the clinical efficacy of equal doses of hyperbaric 0.5% ropivacaine with 0.5% bupivacaine for SA. MATERIALS AND METHODS: Eighty American Society of Anesthesiologists grade I-II patients undergoing elective infraumbilical surgeries under SA were recruited and randomized to receive 3ml of hyperbaric ropivacaine 5mg/ml containing dextrose 83 mg/ml (by the addition of desired dose of 25% dextrose) in Group R or 3ml of hyperbaric bupivacaine 5mg/ml containing dextrose 80 mg/ml in Group B. Monitoring of vitals and observation for the block parameters were carried out. The data were presented as mean with a standard deviation and frequency with percentage. Statistical analysis was performed using InStat computer software with appropriate tests and P < 0.05 was considered to be significant. RESULTS: Ropivacaine produced a slower onset of sensory block (ropivacaine 4.5 min; bupivacaine 3.2 min; P < 0.05) and the mean total duration of sensory block was significantly lesser (ropivacaine155 min; bupivacaine 190.5 min; P < 0.05). Patients in the ropivacaine Group R had significantly more rapid recovery from the motor blockade (ropivacaine120 min; bupivacaine 190 min; P < 0.05) and passed urine sooner than the patients in bupivacaine Group B (ropivacaine 257 min; bupivacaine 358 min; P < 0.05). CONCLUSION: Ropivacaine 15 mg in dextrose 8.3% provides reliable SA of shorter duration than bupivacaine 15 mg in 8% dextrose.

3.
Indian J Anaesth ; 53(6): 683-7, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20640097

RESUMO

SUMMARY: In infants & children variety of conditions and syndromes are associated with difficult Airway. Anaesthetic management becomes a challenge if it remains unrecognized until induction and sometimes results in disaster, leading to oropharyngeal trauma, laryngeal oedema, cardiovascular & neurological complications. A 4-month-old child with multiple congenital anomalies was posted for cataract extraction for early and better development of vision. He had history of post birth respiratory distress, difficulty in feeding, breath holding with delayed mile stones. He was treated as for Juvenile asthma. This child was induced with inhalation anaesthesia. There was difficulty in laryngoscopic intubation and could pass much smaller size of the tube than predicted. He developed post operative stridor and desaturation. The problems which we faced during the anaesthetic management and during postoperative period are discussed with this case.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA