Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Clin Res Cardiol ; 113(1): 18-28, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37017780

RESUMO

AIMS: This study was performed to compare haemodynamic properties of a novel transcatheter heart valve (THV) with two established valve technologies for treatment of failing surgical aortic bioprosthetic valves (SAV). The ALLEGRA THV has been recently described with a proven safety and performance profile. METHODS AND RESULTS: The study was designed as a retrospective, single-centre study investigating 112 patients (77.7 ± 7.1 years, 53.8% female, STS score 6.8 ± 5.8% and logEuroSCORE I 27.4 ± 16.1%) with failing SAV. Patients were treated with the ALLEGRA THV (NVT, n = 24), the CoreValve/EvolutR (MTD, n = 64) or the Edwards Sapien/Sapien XT/Sapien 3 (EDW, n = 24). Adverse events, haemodynamic outcomes and patient safety were analysed according to VARC-3 definitions. Overall procedural success was high (94.6%), even though 58.9% of the treated SAV were classified as small (true inner diameter < 21 mm). After treatment, the mean pressure gradient was significantly reduced (baseline: 33.7 ± 16.5 mmHg, discharge: 18.0 ± 7.1 mmHg), with a corresponding increase in effective orifice area (EOA). The complication rates did not differ in between groups. There was a trend to lower mean transvalvular gradients after implantation of self-expanding THV with supra-annular valve function, despite a higher frequency of smaller SAVs in the NVT and MTD group. Additionally, comparison between NVT and MTD revealed statistically lower transvalvular gradients (NVT 14.9 ± 5.0 mmHg, MTD 18.7 ± 7.5 mmHg, p = 0.0295) in a subgroup analysis. CONCLUSIONS: Valve-in-valve (ViV) treatment of failing SAV with supra-annular design like the ALLEGRA THV resulted in favourable haemodynamic outcomes with similar low clinical event rates and may therefore be an interesting alternative for VIV TAVI.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Terfenadina/análogos & derivados , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Resultado do Tratamento , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese
3.
Struct Heart ; 6(4): 100071, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37288338

RESUMO

Patients with severe symptomatic tricuspid regurgitation face a significant dilemma in treatment options, as the yearly mortality with medical therapy and the surgical mortality for tricuspid repair or replacement are high. Transcatheter edge-to-edge repair (TEER) for the tricuspid valve is becoming a viable option in patients, although procedural success is dependent on high-quality imaging. While transesophageal echocardiography remains the standard for tricuspid TEER procedures, intracardiac echocardiography (ICE) with three-dimensional (3D) multiplanar reconstruction (MPR) has many theoretical and practical advantages. The aim of this article was to describe the in vitro wet lab-based imaging work done to facilitate the best approach to 3D MPR ICE imaging and the procedural experience gained with 3D MPR ICE in tricuspid TEER procedures with the PASCAL device.

4.
Circ Cardiovasc Interv ; 14(2): e009685, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33541097

RESUMO

BACKGROUND: Scarce data exist on patients with right ventricular dysfunction (RVD) or pulmonary hypertension (PH) undergoing transcatheter tricuspid valve intervention. This study aimed to determine the early and midterm outcomes and the factors associated with mortality in this group of patients. METHODS: This subanalysis of the multicenter TriValve (Transcatheter Tricuspid Valve Therapies) registry included 300 patients with severe tricuspid regurgitation with RVD (n=244), PH (n=127), or both (n=71) undergoing transcatheter tricuspid valve intervention. RVD was defined as a tricuspid annular plane systolic excursion <17 mm, and PH as an estimated pulmonary artery systolic pressure ≥50 mm Hg. RESULTS: Mean age of the patients was 77±9 years (54% women). Procedural success was 80.7%, and 9 patients (3%) died during the hospitalization. At a median follow-up of 6 (interquartile range, 2-12) months, 54 patients (18%) died, and the independent associated factors were higher gamma-glutamyl transferase values at baseline (hazard ratio, 1.02 for each increase of 10 u/L [95% CI, 1.002-1.04]), poorer renal function defined as an estimated glomerular filtration rate <45 mL/min (hazard ratio, 2.3 [95% CI, 1.22-4.33]), and the lack of procedural success (hazard ratio, 2.11 [95% CI, 1.17-3.81]). The grade of RVD and the amount of PH at baseline were not found to be predictors of mortality. Most patients alive at follow-up improved their functional class (New York Heart Association I-II in 66% versus 7% at baseline, P<0.001). CONCLUSIONS: In patients with severe tricuspid regurgitation and RVD/PH, transcatheter tricuspid valve intervention was associated with high procedural success and a relatively low in-hospital mortality, along with significant improvements in functional status. However, about 1 out of 5 patients died after a median follow-up of 6 months, with hepatic congestion, renal dysfunction, and the lack of procedural success determining an increased risk. These results may improve the clinical evaluation of transcatheter tricuspid valve intervention candidates and would suggest a closer follow-up in those at increased risk. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03416166.


Assuntos
Implante de Prótese de Valva Cardíaca , Hipertensão Pulmonar , Insuficiência da Valva Tricúspide , Disfunção Ventricular Direita , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Feminino , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , Masculino , New York , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/terapia
5.
J Am Coll Cardiol ; 77(4): 345-356, 2021 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-33509390

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is a prevalent disease with limited treatment options. OBJECTIVES: This is the first 30-day report of the U.S. single-arm, multicenter, prospective CLASP TR early feasibility study of the PASCAL transcatheter valve repair system in the treatment of TR. METHODS: Patients with symptomatic TR despite optimal medical therapy, reviewed by the local heart team and central screening committee, were eligible for the study. Data were collected at baseline, discharge, and the 30-day follow-up and were reviewed by an independent clinical events committee and echocardiographic core laboratory. Feasibility endpoints included safety (composite major adverse event [MAE] rate), echocardiographic, clinical, and functional endpoints. RESULTS: Of the 34 patients enrolled in the study, the mean age was 76 years, 53% were women, the mean Society of Thoracic Surgeons score was 7.3%, 88% had atrial fibrillation/flutter, 97% had severe or greater TR, and 79% had New York Heart Association (NYHA) functional class III/IV symptoms. Twenty-nine patients (85%) received implants; at 30 days, 85% of them achieved a TR severity reduction of at least 1 grade, with 52% with moderate or less TR (p < 0.001). The MAE rate was 5.9%, and none of the patients experienced cardiovascular mortality, stroke, myocardial infarction, renal complication, or reintervention. Eighty-nine percent of the patients improved to NYHA functional class I/II (p < 0.001), the mean 6-min walk distance improved by 71 m (p < 0.001), and the mean Kansas City Cardiomyopathy Questionnaire score improved by 15 points (p < 0.001). CONCLUSIONS: In this early experience, the repair system performed as intended, with substantial TR reduction, favorable safety results with a low MAE rate, no mortality or reintervention, and significant improvements in functional status, exercise capacity, and quality of life. (Edwards CLASP TR EFS [CLASP TR EFS]; NCT03745313).


Assuntos
Anuloplastia da Valva Cardíaca/instrumentação , Procedimentos Endovasculares/instrumentação , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Idoso de 80 Anos ou mais , Anuloplastia da Valva Cardíaca/estatística & dados numéricos , Ecocardiografia , Procedimentos Endovasculares/estatística & dados numéricos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem
6.
JACC Cardiovasc Interv ; 14(1): 41-50, 2021 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-33413863

RESUMO

OBJECTIVES: The study reports for the first time the 30-day outcomes of the first U.S. study with the Cardioband tricuspid valve reconstruction system for the treatment of functional tricuspid regurgitation (TR). BACKGROUND: Increasing severity of TR is associated with progressively higher morbidity and mortality; however, treatment options for isolated significant disease are limited. METHODS: In this single-arm, multicenter, prospective Food and Drug Administration-approved early feasibility study (EFS), 30 patients with severe or greater symptomatic functional TR were enrolled who were deemed candidates for transcatheter tricuspid repair with the Cardioband tricuspid system by the local heart team and multidisciplinary screening committee. RESULTS: The mean patient age was 77 years, 80% were women, 97% had atrial fibrillation, 70% were in New York Heart Association functional class III to IV with mean left ventricular ejection fraction of 58%, and 27% had severe, 20% massive, and 53% torrential TR. Device success was 93% and all patients were alive at 30 days. Between baseline and 30 days, septolateral tricuspid annular diameter was reduced by 13% (p < 0.001), 85% of patients had ≥1 grade TR reduction and 44% had ≤moderate TR, 75% were in New York Heart Association functional class I to II (p < 0.001), and overall Kansas City Cardiomyopathy Questionnaire score improved by 16 points (p < 0.001). CONCLUSIONS: In patients with severe symptomatic functional TR, this is the first study in the United States with the Cardioband tricuspid system for direct transcatheter annular reduction. This early feasibility study demonstrates high procedural feasibility with no 30-day mortality. There is significant reduction of functional TR with clinically significant improvements in functional status and quality of life. (Edwards Cardioband Tricuspid Valve Reconstruction System Early Feasibility Study; NCT03382457).


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Cateterismo Cardíaco , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Insuficiência da Valva Tricúspide/cirurgia , Função Ventricular Esquerda
7.
EuroIntervention ; 16(15): e1264-e1271, 2021 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-33046437

RESUMO

AIMS: Tricuspid regurgitation (TR) is associated with high morbidity and mortality rates with limited treatment options. We report one- and two-year outcomes of the Cardioband tricuspid valve reconstruction system in the treatment of ≥moderate functional TR in the TRI-REPAIR study. METHODS AND RESULTS: Thirty patients were enrolled in this single-arm, multicentre, prospective study. Patients were evaluated as having ≥moderate, symptomatic functional TR and deemed inoperable due to unacceptable surgical risk. Clinical, functional, and echocardiographic data were prospectively collected up to two years (mean duration 604±227 days). At baseline, 83% were in NYHA Class III-IV, and the mean LVEF was 58%. Technical success was 100%. At two years, there were eight deaths. Echocardiography showed a significant reduction in septolateral annular diameter of 16% (p=0.006) and 72% of patients (p=0.016) with ≤moderate TR grade; 82% of patients were in NYHA Class I-II (p=0.002). Six-minute walk distance and KCCQ score improved by 73 m (p=0.058) and 14 points (p=0.046), respectively. CONCLUSIONS: These results demonstrate that the Cardioband tricuspid system showed favourable results in patients with symptomatic, ≥moderate functional TR. Annular reduction and TR severity reduction remained significant and sustained at two years. Patients experienced improvements in quality of life and exercise capacity. ClinicalTrials.gov Identifier: NCT02981953.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
8.
JACC Cardiovasc Interv ; 13(17): 1999-2009, 2020 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-32912460

RESUMO

OBJECTIVES: The aim of this study was to assess the clinical outcome of baseline massive or torrential tricuspid regurgitation (TR) after transcatheter tricuspid valve intervention (TTVI). BACKGROUND: The use of TTVI to treat symptomatic severe TR has been increasing rapidly, but little is known regarding the impact of massive or torrential TR beyond severe TR. METHODS: The study population comprised 333 patients with significant symptomatic TR from the TriValve Registry who underwent TTVI. Mid-term outcomes after TTVI were assessed according to the presence of massive or torrential TR, defined as vena contracta width ≥14 mm. Procedural success was defined as patient survival after successful device implantation and delivery system retrieval, with residual TR ≤2+. The primary endpoint comprised survival rate and freedom from rehospitalization for heart failure, survival rate, and rehospitalization at 1 year. RESULTS: Baseline massive or torrential TR and severe TR were observed in 154 patients (46.2%) and 179 patients (53.8%), respectively. Patients with massive or torrential TR had a higher prevalence of ascites than those with severe TR (27.3% vs. 20.4%, respectively; p = 0.15) and demonstrated a similar procedural success rate (83.2% vs. 77.3%, respectively; p = 0.21). The incidence of peri-procedural adverse events was low, with no significant between-group differences. Freedom from the composite endpoint was significantly lower in patients with massive or torrential TR than in those with severe TR, which was significantly associated with an increased risk for 1-year death of any cause or rehospitalization for heart failure (adjusted hazard ratio: 1.91; 95% confidence interval: 1.10 to 3.34; p = 0.022). Freedom from the composite endpoint was significantly higher in patients with massive or torrential TR when procedural success was achieved (69.9% vs. 54.2%, p = 0.048). CONCLUSIONS: Baseline massive or torrential TR is associated with an increased risk for all-cause mortality and rehospitalization for heart failure 1 year after TTVI. Procedural success is related to better outcomes, even in the presence of baseline massive or torrential TR. (International Multisite Transcatheter Tricuspid Valve Therapies Registry [TriValve]; NCT03416166).


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Progressão da Doença , Europa (Continente) , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , América do Norte , Readmissão do Paciente , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/fisiopatologia
9.
J Am Coll Cardiol ; 76(9): 1018-1030, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32854836

RESUMO

BACKGROUND: Bicuspid aortic stenosis accounts for almost 50% of patients undergoing surgical aortic valve replacement in the younger patients. Expanding the indication of transcatheter aortic valve replacement (TAVR) toward lower-risk and younger populations will lead to increased use of TAVR for patients with bicuspid aortic valve (BAV) stenosis despite the exclusion of bicuspid anatomy in all pivotal clinical trials. OBJECTIVES: This study sought to evaluate the association of BAV morphology and outcomes of TAVR with the new-generation devices. METHODS: Patients with BAV confirmed by central core laboratory computed tomography (CT) analysis were included from the international multicenter BAV TAVR registry. BAV morphology including the number of raphe, calcification grade in raphe, and leaflet calcium volume were assessed with CT analysis in a masked fashion. Primary outcomes were all-cause mortality at 1 and 2 years, and secondary outcomes included 30-day major endpoints and procedural complications. RESULTS: A total of 1,034 CT-confirmed BAV patients with a mean age of 74.7 years and Society of Thoracic Surgeons score of 3.7% underwent TAVR with contemporary devices (n = 740 with Sapien 3; n = 188 with Evolut R/Pro; n = 106 with others). All-cause 30-day, 1-year, and 2-year mortality was 2.0%, 6.7%, and 12.5%, respectively. Multivariable analysis identified calcified raphe and excess leaflet calcification (defined as more than median calcium volume) as independent predictors of 2-year all-cause mortality. Both calcified raphe plus excess leaflet calcification were found in 269 patients (26.0%), and they had significantly higher 2-year all-cause mortality than those with 1 or none of these morphological features (25.7% vs. 9.5% vs. 5.9%; log-rank p < 0.001). Patients with both morphological features had higher rates of aortic root injury (p < 0.001), moderate-to-severe paravalvular regurgitation (p = 0.002), and 30-day mortality (p = 0.016). CONCLUSIONS: Outcomes of TAVR in bicuspid aortic stenosis depend on valve morphology. Calcified raphe and excess leaflet calcification were associated with increased risk of procedural complications and midterm mortality. (Bicuspid Aortic Valve Stenosis Transcatheter Aortic Valve Replacement Registry; NCT03836521).


Assuntos
Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/cirurgia , Internacionalidade , Sistema de Registros , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/tendências , Idoso , Idoso de 80 Anos ou mais , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Mortalidade/tendências , Estudos Prospectivos , Tomografia Computadorizada por Raios X/mortalidade , Tomografia Computadorizada por Raios X/tendências , Resultado do Tratamento
10.
Am Heart J ; 225: 138-148, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32502877

RESUMO

BACKGROUND: Compared to high gradient aortic stenosis (AS), patients with low-flow, low-gradient AS have higher mortality after transcatheter aortic valve replacement (TAVR), but distinct outcome predictors in this patient subset are yet to be determined. The present study investigated the prognostic impact of aortic valve calcification (AVC) in patients with low-flow, low-gradient AS undergoing TAVR. METHODS: This retrospective single-center analysis includes all patients undergoing TAVR for severe low-flow, low-gradient AS (n = 526), ie, low EF low gradient AS (LEF-LG AS; n = 290) and paradoxical low-flow, low-gradient AS (PLF-LG AS; n = 236), in whom AVC was quantified from contrast-enhanced multislice computed tomography images. AVCdensity was defined as calcium volume per annulus area. Patients were trichotomized according to sex-specific AVCdensity tertiles in both subgroups. All-cause mortality was assessed by Kaplan-Meier analyses and independent outcome predictors were determined by multivariable analyses. RESULTS: In both subgroups, patients with high AVCdensity had higher mean transvalvular gradients at baseline and higher rates of PVL after TAVR. High AVCdensity was associated with lowest 1- and 3-year mortality after TAVR in the LEF-LG AS but not in the PLF-LG AS group. According to multivariable analysis AVCdensity was independently associated with better survival in LEF-LG AS patients (HR 0.73 [0.60-0.88], P = .0011), but not in those with PLF-LG AS (HR 0.91 [0.73-1.14], P = .42). CONCLUSIONS: Quantification of AVC may not only be of diagnostic but also of prognostic value, as it facilitates the selection of LEF-LG AS patients with higher probability of beneficial outcome after TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Calcinose/classificação , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Calcinose/fisiopatologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Volume Sistólico
11.
Open Heart ; 7(1)2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32393655

RESUMO

OBJECTIVE: Residual paravalvular regurgitation (PVR) has been associated to adverse outcomes after transcatheter aortic valve replacement (TAVR). This study sought to evaluate the impact of device landing zone (DLZ) calcification on residual PVR after TAVR with different next-generation transcatheter heart valves. METHODS: 642 patients underwent TAVR with a SAPIEN 3 (S3; n=292), ACURATE neo (NEO; n=166), Evolut R (ER; n=132) or Lotus (n=52). Extent, location and asymmetry of DLZ calcification were assessed from contrast-enhanced CT imaging and correlated to PVR at discharge. RESULTS: PVR was ≥moderate in 0.7% of S3 patients, 9.6% of NEO patients, 9.8% of ER patients and 0% of Lotus patients (p<0.001), and these differences remained after matching for total DLZ calcium volume. The amount of DLZ calcium was significantly related to the degree of PVR in patients treated with S3 (p=0.045), NEO (p=0.004) and ER (p<0.001), but not in Lotus patients (p=0.698). The incidence of PVR ≥moderate increased significantly over the tertiles of DLZ calcium volume (p=0.046). On multivariable analysis, calcification of the aortic valve cusps, LVOT calcification and the use of self-expanding transcatheter aortic valve implantation (TAVI) prostheses emerged as predictors of PVR. CONCLUSIONS: The susceptibility to PVR depending on the amount of calcium was mainly observed in self-expanding TAVI prostheses. Thus, DLZ calcification is an important factor to be considered in prosthesis selection for each individual patient, keeping in mind the trade-off between PVR reduction, risk of new pacemaker implantation and unfavourable valve ha emodynamics.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Calcinose/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/fisiopatologia , Feminino , Alemanha , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
12.
JACC Cardiovasc Interv ; 13(10): 1251-1261, 2020 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-32360260

RESUMO

OBJECTIVES: The aim of this study was to assess the value of echocardiographic right ventricular (RV) and systolic pulmonary artery pressure (sPAP) assessment in predicting transcatheter tricuspid edge-to-edge valve repair (TTVR) outcome. BACKGROUND: RV dysfunction and pulmonary hypertension are associated with poor prognosis and are systematically sought during tricuspid regurgitation evaluation. The value of echocardiographic assessment in predicting TTVR outcome is unknown. METHODS: Data were taken from the TriValve (Transcatheter Tricuspid Valve Therapies) registry, which includes patients undergoing TTVR at 14 European and North American centers. The primary outcome was 1-year survival free from hospitalization for heart failure, and secondary outcomes were 1-year survival and absence of hospital admission for heart failure at 1 year. RESULTS: Overall, 249 patients underwent TTVR between June 2015 and 2018 (mean tricuspid annular plane systolic excursion [TAPSE] 15.8 ± 15.3 mm, mean sPAP 43.6 ± 16.0 mm Hg). Tricuspid regurgitation grade ≥3+ was found in 96.8% of patients at baseline and 29.4% at final follow-up; 95.6% were in New York Heart Association functional class III or IV initially, compared with 34.3% at follow-up (p < 0.05). Final New York Heart Association functional class did not differ among TAPSE and sPAP quartiles, even when both low TAPSE and high sPAP were present. Rates of 1-year survival and survival free from hospitalization for heart failure were 83.9% and 78.7%, respectively, without significant differences according to baseline echocardiographic RV characteristics (TAPSE, fractional area change, and end-diastolic area) and sPAP (p > 0.05 for all). CONCLUSIONS: TTVR provides clinical improvement, with 1-year survival free from hospital readmission >75% in patients with severe tricuspid regurgitation. Conventional echocardiographic parameters used to assess RV function and sPAP did not predict clinical outcome after TTVR.


Assuntos
Pressão Arterial , Cateterismo Cardíaco , Ecocardiografia , Artéria Pulmonar/diagnóstico por imagem , Insuficiência da Valva Tricúspide/terapia , Função Ventricular Direita , Pressão Ventricular , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Progressão da Doença , Europa (Continente) , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte , Valor Preditivo dos Testes , Estudos Prospectivos , Artéria Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Sistema de Registros , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia
13.
EuroIntervention ; 16(3): 251-258, 2020 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-32287036

RESUMO

AIMS: The high frequency of screening failure for anatomical reasons in patients with severe mitral valve regurgitation (MR) is a limiting factor in the screening process for transcatheter mitral valve replacement (TMVR). However, data on optimal patient selection are scarce. The present study aimed to develop a screening algorithm based on TMVR screening data. METHODS AND RESULTS: A total of 195 screenings for six different TMVR devices were performed in 94 high-risk patients with severe MR. We compared baseline echocardiographic and multislice computed tomography (MSCT) parameters between the subgroups of patients accepted (N=33) and rejected for TMVR (N=61). Reasons for screening failure were assessed, and a decision tree algorithm was statistically derived. Reasons for screening failure were small LV dimensions (30.6%), small (7.5%) or large (22.5%) annular size, potential risk of LVOT obstruction (22.0%) or mitral annulus calcification (15.6%). A four-step decision tree algorithm to assess TMVR eligibility was developed resulting in an AUC of 0.80 (95% CI: 0.71, 0.89, p<0.0001). CONCLUSIONS: This study presents the first screening algorithm to assess anatomical eligibility for TMVR in patients with severe MR, based on simple MSCT criteria. Given the high rate of TMVR screening failure, this algorithm may facilitate the identification of potential TMVR candidates.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Algoritmos , Árvores de Decisões , Humanos , Valva Mitral , Resultado do Tratamento
14.
JACC Cardiovasc Interv ; 13(5): 554-564, 2020 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-31954676

RESUMO

OBJECTIVES: The interference of a transtricuspid cardiac implantable electronic device (CIED) lead with tricuspid valve function may contribute to the mechanism of tricuspid regurgitation (TR) and poses specific therapeutic challenges during transcatheter tricuspid valve intervention (TTVI). Feasibility and efficacy of TTVI in presence of a CIED is unclear. BACKGROUND: Feasibility of TTVI in presence of a CIED lead has never been proven on a large basis. METHODS: The study population consisted of 470 patients with severe symptomatic TR from the TriValve (Transcatheter Tricuspid Valve Therapies) registry who underwent TTVI at 21 centers between 2015 and 2018. The association of CIED and outcomes were assessed. RESULTS: Pre-procedural CIED was present in 121 of 470 (25.7%) patients. The most frequent location of the CIED lead was the posteroseptal commissure (44.0%). As compared with patients without a transvalvular lead (no-CIED group), patients having a tricuspid lead (CIED group) were more symptomatic (New York Heart Association functional class III to IV in 95.9% vs. 92.3%; p = 0.02) and more frequently had previous episodes of right heart failure (87.8% vs. 69.0%; p = 0.002). No-CIED patients had more severe TR (effective regurgitant orifice area 0.7 ± 0.6 cm2 vs. 0.6 ± 0.3 cm2; p = 0.02), but significantly better right ventricular function (tricuspid annular plane systolic excursion = 16.7 ± 5.0 mm vs. 15.9 ± 4.0 mm; p = 0.04). Overall, 373 patients (79%) were treated with the MitraClip (Abbott Vascular, Santa Clara, California) (106 [87.0%] in the CIED group). Among them, 154 (33%) patients had concomitant transcatheter mitral repair (55 [46.0%] in the CIED group, all MitraClip). Procedural success was achieved in 80.0% of no-CIED patients and in 78.6% of CIED patients (p = 0.74), with an in-hospital mortality of 2.9% and 3.7%, respectively (p = 0.70). At 30 days, residual TR ≤2+ was observed in 70.8% of no-CIED and in 73.7% of CIED patients (p = 0.6). Symptomatic improvement was observed in both groups (NYHA functional class I to II at 30 days: 66.0% vs. 65.0%; p = 0.30). Survival at 12 months was 80.7 ± 3.0% in the no-CIED patients and 73.6 ± 5.0% in the CIED patients (p = 0.30). CONCLUSIONS: TTVI is feasible in selected patients with CIED leads and acute procedural success and short-term clinical outcomes are comparable to those observed in patients without a transtricuspid lead.


Assuntos
Cateterismo Cardíaco/instrumentação , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/mortalidade , Tomada de Decisão Clínica , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Europa (Continente) , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Mortalidade Hospitalar , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , América do Norte , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
J Am Coll Cardiol ; 74(24): 2998-3008, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31568868

RESUMO

BACKGROUND: Tricuspid regurgitation is associated with increased rates of heart failure (HF) and mortality. Transcatheter tricuspid valve interventions (TTVI) are promising, but the clinical benefit is unknown. OBJECTIVES: The purpose of this study was to investigate the potential benefit of TTVI over medical therapy in a propensity score matched population. METHODS: The TriValve (Transcatheter Tricuspid Valve Therapies) registry collected 472 patients from 22 European and North American centers who underwent TTVI from 2016 to 2018. A control cohort formed by 2 large retrospective registries enrolling medically managed patients with ≥ moderate tricuspid regurgitation in Europe and North America (n = 1,179) were propensity score 1:1 matched (distance ± 0.2 SD) using age, EuroSCORE II, and systolic pulmonary artery pressure. Survival was tested with Cox regression analysis. Primary endpoint was 1-year mortality or HF rehospitalization or the composite. RESULTS: After matching, 268 adequately matched pairs of patients were identified. Compared with control subjects, TTVI patients had lower 1-year mortality (23 ± 3% vs. 36 ± 3%; p = 0.001), rehospitalization (26 ± 3% vs. 47 ± 3%; p < 0.0001), and composite endpoint (32 ± 4% vs. 49 ± 3%; p = 0.0003). TTVI was associated with greater survival and freedom from HF rehospitalization (hazard ratio [HR]: 0.60; 95% confidence interval [CI]: 0.46 to 0.79; p = 0.003 unadjusted), which remained significant after adjusting for sex, New York Heart Association functional class, right ventricular dysfunction, and atrial fibrillation (HR: 0.39; 95% CI: 0.26 to 0.59; p < 0.0001) and after further adjustment for mitral regurgitation and pacemaker/defibrillator (HR: 0.35; 95% CI: 0.23 to 0.54; p < 0.0001). CONCLUSIONS: In this propensity-matched case-control study, TTVI is associated with greater survival and reduced HF rehospitalization compared with medical therapy alone. Randomized trials should be performed to confirm these results.


Assuntos
Procedimentos Cirúrgicos Cardíacos/mortalidade , Procedimentos Endovasculares/mortalidade , Sistema de Registros , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Ecocardiografia , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , América do Norte/epidemiologia , Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/tratamento farmacológico , Insuficiência da Valva Tricúspide/mortalidade
16.
Eur J Cardiothorac Surg ; 56(6): 1131-1139, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31566209

RESUMO

OBJECTIVES: The aim of the study was to determine the differences in outcomes of surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) in low-risk patients. METHODS: All patients with a logistic EuroSCORE II <4% who underwent transfemoral TAVI between 2008 and 2016 (n = 955) or SAVR between 2009 and 2014 (n = 886) at our centre were included. One hundred and nine patients per group were available for propensity score matching. RESULTS: Mortality during the 30-day follow-up showed no differences (SAVR vs TAVI: 1.1% vs 1.8%, P = 1.0) but the rates of permanent pacemaker implantation (0.0 vs 14.8%, P < 0.001) and paravalvular leakage ≥ moderate (0.0 vs 7.0%, P = 0.017) were higher in TAVI patients. No difference was found regarding postoperative effective orifice area and transvalvular pressure gradients. Although, the 1-year survival was similar between both groups; 3- and 5-year survival was significantly inferior in the TAVI patient cohort. CONCLUSIONS: TAVI yielded similar short-term outcomes compared with SAVR despite higher rates of permanent pacemaker implantation and paravalvular leakage ≥ moderate, but inferior long-term survival. Poorer long-term outcomes of the TAVI patient cohort were attributable to a more comorbid TAVI population. This emphasizes the need for long-term results from randomized controlled trials before TAVI can be broadly expanded to younger low-risk patients.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade
17.
JACC Cardiovasc Interv ; 12(18): 1781-1793, 2019 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-31537278

RESUMO

OBJECTIVES: This study sought to evaluate the impact of the ACURATE neo (NEO) (Boston Scientific, Marlborough, Massachusetts) versus SAPIEN 3 (S3) (Edwards Lifesciences, Irvine, California) on permanent pacemaker implantation (PPI) in patients with pre-existing right bundle branch block (RBBB) after transcatheter aortic valve replacement. BACKGROUND: Pre-existing RBBB is the strongest patient-related predictor for PPI after transcatheter aortic valve replacement. No comparison of newer-generation transcatheter heart valves with regard to PPI in these patients exists. METHODS: This multicenter registry includes 4,305 patients; 296 (6.9%) had pre-existent RBBB and no pacemaker at baseline and formed the study population. The primary endpoint was new PPI at 30 days. The association of NEO versus S3 with PPI was assessed using binary logistic regression analyses and inverse probability treatment weighting in a propensity-matched population. RESULTS: The 30-day PPI rate was 39.2%. The S3 and NEO were used in 66.9% and 33.1%, respectively. The NEO was associated with lower rates of PPI compared with the S3 (29.6% vs. 43.9%; p = 0.025; odds ratio [OR]: 0.54; 95% confidence interval [CI]: 0.32 to 0.89; p = 0.018), after multivariable adjustment (OR: 0.48; 95% CI: 0.26 to 0.86; p = 0.014), and in the inverse probability treatment weighting analysis (OR: 0.37; 95% CI: 0.25 to 0.55; p < 0.001). There was no difference in device failure (8.2% vs. 6.6%; p = 0.792) or in-hospital course. In the propensity-matched population, PPI rate was also lower in the NEO versus S3 (23.1% vs. 44.6%; p = 0.016; OR: 0.37; 95% CI: 0.17 to 0.78; p = 0.010), with no difference in device failure (9.2% vs. 6.2%; p = 0.742). CONCLUSIONS: In patients with RBBB, risk of PPI was significantly lower with the NEO compared with the S3, suggesting the possibility of a patient tailored transcatheter heart valve therapy.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/cirurgia , Estimulação Cardíaca Artificial , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Bloqueio de Ramo/complicações , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Feminino , Alemanha , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Suíça , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
18.
JACC Cardiovasc Interv ; 12(15): 1451-1461, 2019 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-31395215

RESUMO

OBJECTIVES: The purpose of this study was to evaluate procedural and 1-year clinical and echocardiographic outcomes of patients treated with tricuspid edge-to-edge repair. BACKGROUND: Transcatheter edge-to-edge repair has been successfully performed in selected patients with symptomatic tricuspid regurgitation (TR) and high risk for surgery, but outcome data are sparse. METHODS: This analysis of the multicenter international TriValve (Transcatheter Tricuspid Valve Therapies) registry included 249 patients with severe TR treated with edge-to-edge repair in compassionate and/or off-label use. Clinical and echocardiographic outcomes were prospectively collected and retrospectively analyzed. RESULTS: In 249 patients (mean age 77 ± 9 years; European System for Cardiac Operative Risk Evaluation II score 6.4% [interquartile range: 3.9% to 13.9%]), a successful procedure with TR reduction to grade ≤2+ was achieved in 77% by placement of 2 ± 1 tricuspid clips. Concomitant treatment of severe TR and mitral regurgitation was performed in 52% of patients. At 1-year follow-up, significant and durable improvements in TR severity (TR ≤2+ in 72% of patients) and New York Heart Association functional class (≤II in 69% of patients) were observed. All-cause mortality was 20%, and the combined rate of mortality and unplanned hospitalization for heart failure was 35%. Predictors of procedural failure included effective regurgitant orifice area, tricuspid coaptation gap, tricuspid tenting area, and absence of central or anteroseptal TR jet location. Predictors of 1-year mortality were procedural failure, worsening kidney function, and absence of sinus rhythm. CONCLUSIONS: Transcatheter tricuspid edge-to-edge repair can achieve TR reduction at 1 year, resulting in significant clinical improvement. Predictors of procedural failure and 1-year mortality identified here may help select patients who will benefit most from this therapy.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Ensaios de Uso Compassivo , Europa (Continente) , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , América do Norte , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/fisiopatologia
19.
J Am Coll Cardiol ; 73(15): 1905-1915, 2019 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-30999993

RESUMO

BACKGROUND: Severe tricuspid regurgitation (TR) is associated with high morbidity and mortality rates with limited treatment options. OBJECTIVES: The authors report the 6-month safety and performance of a transcatheter tricuspid valve reconstruction system in the treatment of moderate to severe functional TR in 30 patients enrolled in the TRI-REPAIR (TrIcuspid Regurgitation RePAIr With CaRdioband Transcatheter System) study. METHODS: Between October 2016 and July 2017, 30 patients were enrolled in this single-arm, multicenter, prospective trial. Patients were diagnosed with moderate to severe, symptomatic TR in the absence of untreated left-heart disease and deemed inoperable because of unacceptable risk for open-heart surgery by the local heart team. Clinical, functional, and echocardiographic data were prospectively collected before and up to 6 months post-procedure. An independent core lab assessed all echocardiographic data, and an independent clinical event committee adjudicated the safety events. RESULTS: Mean patient age was 75 years, 73% were female, and 23% had ischemic heart disease. At baseline, 83% were in New York Heart Association (NYHA) functional class III to IV, and mean left ventricular ejection fraction was 58%. Technical success was 100%. Through 6 months, 3 patients died. Between 6 months and baseline, echocardiography showed average reductions of annular septolateral diameter of 9% (42 mm vs. 38 mm; p < 0.01), proximal isovelocity surface area effective regurgitant orifice area of 50% (0.8 cm2 vs. 0.4 cm2; p < 0.01), and mean vena contracta width of 28% (1.2 cm vs. 0.9 cm; p < 0.01). Clinical assessment showed that 76% of patients improved by at least 1 NYHA functional class with 88% in NYHA functional class I or II. Six-minute walk distance improved by 60 m (p < 0.01), and Kansas City Cardiomyopathy Questionnaire score improved by 24 points (p < 0.01). CONCLUSIONS: Six-month outcomes show that the system performs as intended and appears to be safe in patients with symptomatic and moderate to severe functional TR. Significant reduction of TR through decrease of annular dimensions, improvements in heart failure symptoms, quality of life, and exercise capacity were observed. Further studies are warranted to validate these initial promising results. (TrIcuspid Regurgitation RePAIr With CaRdioband Transcatheter System [TRI-REPAIR]; NCT02981953).


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Mortalidade Hospitalar/tendências , Insuficiência da Valva Tricúspide/cirurgia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Doppler/métodos , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Estudos Prospectivos , Procedimentos de Cirurgia Plástica/métodos , Procedimentos de Cirurgia Plástica/mortalidade , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/mortalidade
20.
Int J Cardiol ; 275: 65-69, 2019 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-30366854

RESUMO

BACKGROUND: Balloon aortic valvuloplasty (BAV) is routinely performed preceding transcatheter aortic valve implantation (TAVI). Among risks inherent in BAV is low cardiac output due to rapid ventricular pacing (RVP), especially in patients with severely impaired left ventricular function. We herein report early experience utilizing a non-occlusive balloon for BAV (TrueFlow™, BARD, Peripheral Vascular, Tempe, AZ, US), which does not require RVP. METHODS: Between 11/2016 and 10/2017, 27 consecutive patients received TAVI using a non-occlusive balloon valvuloplasty catheter for predilatation and a self-expandable transcatheter heart valve (77.8% female, 81.7 ±â€¯6.6 years, logEuroSCORE I 15.8 ±â€¯10.3%, STS Prom Score 2.5 ±â€¯0.5%). Hemodynamic measurements and acute outcome data were analyzed according to updated Valve Academic Research Consortium definitions. RESULTS: Procedure time, fluoroscopy time and amount of contrast agent were 74.5 ±â€¯17.4 min, 16.7 ±â€¯6.9 min and 156.9 ±â€¯92.7 ml. Device success and early combined safety were 100% and 92.6% (25/27). Effective BAV without RVP after the first inflation was achieved in 92.6% of the patients (25/27). Continuous recording of hemodynamics documented no relevant systemic pressure drop during BAV. Postdilatation with a regular balloon was required in 10/27 patients. No death was observed during 30-day follow-up. Resultant mean transvalvular gradient was 6.0 ±â€¯3.5 mm Hg. In one patient a moderate paravalvular leakage was seen. CONCLUSIONS: In this series of TAVI utilizing a novel non-occlusive balloon, safety and efficacy were demonstrated. Adequate predilatation was achieved in all cases without need for RVP and with stable hemodynamics. These results will have to be confirmed in larger patient cohorts.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valvuloplastia com Balão/instrumentação , Calcinose/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Calcinose/diagnóstico , Ecocardiografia Transesofagiana , Feminino , Fluoroscopia , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Estudos Retrospectivos , Índice de Gravidade de Doença , Cirurgia Assistida por Computador , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...