Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 164
Filtrar
1.
Optica ; 8(5)2021.
Artigo em Inglês | MEDLINE | ID: mdl-36578655

RESUMO

We present high-reflectivity substrate-transferred single-crystal GaAs/AlGaAs interference coatings at a center wavelength of 4.54 µm with record-low excess optical loss below 10 parts per million. These high-performance mirrors are realized via a novel microfabrication process that differs significantly from the production of amorphous multilayers generated via physical vapor deposition processes. This new process enables reduced scatter loss due to the low surface and interfacial roughness, while low background doping in epitaxial growth ensures strongly reduced absorption. We report on a suite of optical measurements, including cavity ring-down, transmittance spectroscopy, and direct absorption tests to reveal the optical losses for a set of prototype mirrors. In the course of these measurements, we observe a unique polarization-orientation-dependent loss mechanism which we attribute to elastic anisotropy of these strained epitaxial multilayers. A future increase in layer count and a corresponding reduction of transmittance will enable optical resonators with a finesse in excess of 100 000 in the mid-infrared spectral region, allowing for advances in high resolution spectroscopy, narrow-linewidth laser stabilization, and ultrasensitive measurements of various light-matter interactions.

2.
Phys Rev E ; 101(2-1): 023202, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32168599

RESUMO

The work presented in this paper shows with the help of two-dimensional hydrodynamic simulations that intense heavy-ion beams are a very efficient tool to induce high energy density (HED) states in solid matter. These simulations have been carried out using a computer code BIG2 that is based on a Godunov-type numerical algorithm. This code includes ion beam energy deposition using the cold stopping model, which is a valid approximation for the temperature range accessed in these simulations. Different phases of matter achieved due to the beam heating are treated using a semiempirical equation-of-state (EOS) model. To take care of the solid material properties, the Prandl-Reuss model is used. The high specific power deposited by the projectile particles in the target leads to phase transitions on a timescale of the order of tens of nanosecond, which means that the sample material achieves thermodynamic equilibrium during the heating process. In these calculations we use Pb as the sample material that is irradiated by an intense uranium beam. The beam parameters including particle energy, focal spot size, bunch length, and bunch intensity are considered to be the same as the design parameters of the ion beam to be generated by the SIS100 heavy-ion synchrotron at the Facility for Antiprotons and Ion Research (FAIR), at Darmstadt. The purpose of this work is to propose experiments to measure the EOS properties of HED matter including studies of the processes of phase transitions at the FAIR facility. Our simulations have shown that depending on the specific energy deposition, solid lead will undergo phase transitions leading to an expanded hot liquid state, two-phase liquid-gas state, or the critical parameter regime. In a similar manner, other materials can be studied in such experiments, which will be a very useful addition to the knowledge in this important field of research.

3.
Opt Express ; 27(25): 36731-36740, 2019 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-31873446

RESUMO

Precision interferometry is the leading method for extremely sensitive measurements in gravitational wave astronomy. Thermal noise of dielectric coatings poses a limitation to the sensitivity of these interferometers. To decrease coating thermal noise, new crystalline GaAs/AlGaAs multilayer mirrors have been developed. To date, the surface figure and thickness uniformity of these alternative low-loss coatings has not been investigated. Surface figure errors, for example, cause small angle scattering and thereby limit the sensitivity of an interferometer. Here we measure the surface figure of highly reflective, substrate-transferred, crystalline GaAs/AlGaAs coatings with a custom scanning reflectance system. We exploit the fact that the reflectivity varies with the thickness of the coating. To increase penetration into the coating, we used a 1550 nm laser on a highly reflective coating designed for a center wavelength of 1064 nm. The RMS thickness variation of a two inch optic was measured to be 0.41 ± 0.05 nm. This result is within 10% of the thickness uniformity, of 0.37 nm RMS, achieved with ion-beam sputtered coatings for the aLIGO detector. We additionally measured a lower limit of the laser induced damage threshold of 64 MW/cm 2 for GaAs/AlGaAs coatings at a wavelength of 1064 nm.

4.
J Comp Pathol ; 173: 58-70, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31812174

RESUMO

Serum iron concentration is usually decreased in true iron deficiency and with inflammatory disease in man and domestic animals. Serum total iron binding capacity (TIBC) may be increased in true iron deficiency and decreased with inflammatory disease. This prospective study was designed to measure serum iron analytes in healthy free-ranging and housed Florida manatees (Trichechus manatus latirostris) of both sexes and various ages and to evaluate the effects of diseases common to manatees on these analytes. Blood samples were collected without anticoagulant from 137 healthy free-ranging manatees, 90 healthy housed manatees and 74 free-ranging diseased manatees, and serum was prepared by centrifugation. Serum iron concentration and unsaturated iron binding capacity were measured colourimetrically, and TIBC and percent transferrin saturation with iron were calculated. Serum amyloid A (SAA) was measured to assist in the health assessment of manatees and provide evidence of inflammation in diseased manatees. Based on the serum iron analytes, iron availability was lower in immature manatees compared with adults, and it was lower in housed manatees compared with free-ranging manatees. In contrast to other mammals studied, serum iron concentration was elevated rather than depressed in late pregnancy. Serum iron concentrations and transferrin saturation with iron percentages were significantly lower, and SAA concentrations were significantly higher, in diseased (ill and injured) manatees compared with healthy manatees. Serum iron concentration and transferrin saturation with iron values were negatively correlated with SAA concentrations, and manatees with the highest SAA concentrations had lower serum TIBC values. These findings indicate that inflammation is the major factor responsible for alterations in iron analytes in diseased manatees. Consequently, hypoferraemia may be used as supportive evidence of inflammatory disease in manatees (unless haemorrhage is also present). A decision threshold of ≤13.8 µmol/l was determined for hypoferraemia using receiver operating curve analysis. Based on studies in man and domestic animals, iron therapy is unnecessary for manatees with hypoferraemia associated with inflammation and has the potential for causing tissue damage and increased susceptibility to bacterial infections.


Assuntos
Ferro/sangue , Trichechus manatus , Animais , Valores de Referência
5.
Sci Rep ; 9(1): 17780, 2019 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-31780725

RESUMO

Dissolved organic carbon (DOC) is the main energy source for marine heterotrophic microorganisms, but a small fraction of DOC resists microbial degradation and accumulates in the ocean. The reason behind this recalcitrance is unknown. We test whether the long-term stability of DOC requires the existence of structurally refractory molecules, using a mechanistic model comprising a diverse network of microbe-substrate interactions. Model experiments reproduce three salient observations, even when all DOC compounds are equally degradable: (i) >15% of an initial DOC pulse resists degradation, but is consumed by microbes if concentrated, (ii) the modelled deep-sea DOC reaches stable concentrations of 30-40 mmolC/m3, and (iii) the mean age of deep-sea DOC is several times the age of deep water with a wide range from <100 to >10,000 years. We conclude that while structurally-recalcitrant molecules exist, they are not required in the model to explain either the amount or longevity of DOC.

6.
Phys Rev E ; 99(1-1): 011201, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30780231

RESUMO

Peculiar behavior is found in a Si cluster ion, moving with a speed of ∼0.22c (c: speed of light) in a solid Al plasma in the context of cluster-ion beam driven inertial confinement fusion: The Si ion, moving closely behind the forward-moving Si ion for a distance of several Šin the cluster, feels the wake field generated by the forward Si. The acceleration interaction force on the rear Si ion by the forward-moving ion may balance with the deceleration backward force in the longitudinal-moving direction. The forward-moving Si ion would be decelerated, as an isolated ion is decelerated without correlation. However, the deceleration of the rear Si ion, moving behind closely, would be reduced significantly. The rear Si ion may catch up and overtake the forward-moving Si ion in the cluster during the Si cluster-ion interaction with the high-density Al plasma. This peculiar behavior appears when the ions are aligned well longitudinally. The wake field is confined around the Si ion in the forward and transverse directions for a distance smaller than the Si cluster interionic distance l_{c}. However, the tail of the wake field extends beyond l_{c} due to the Si ion high speed of ∼0.22c. Therefore, the peculiar behavior shown above appears only for the ions in one cluster aligned well longitudinally.

7.
Sci Adv ; 4(12): eaau5180, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30585291

RESUMO

Oxygen minimum zones (OMZs), large midwater regions of very low oxygen, are expected to expand as a result of climate change. While oxygen is known to be important in structuring midwater ecosystems, a precise and mechanistic understanding of the effects of oxygen on zooplankton is lacking. Zooplankton are important components of midwater food webs and biogeochemical cycles. Here, we show that, in the eastern tropical North Pacific OMZ, previously undescribed submesoscale oxygen variability has a direct effect on the distribution of many major zooplankton groups. Despite extraordinary hypoxia tolerance, many zooplankton live near their physiological limits and respond to slight (≤1%) changes in oxygen. Ocean oxygen loss (deoxygenation) may, thus, elicit major unanticipated changes to midwater ecosystem structure and function.


Assuntos
Oxigênio/química , Água do Mar/química , Zooplâncton/fisiologia , Adaptação Fisiológica , Animais , Respiração Celular , Mudança Climática , Ecossistema , Cadeia Alimentar , Hipóxia , Oceanos e Mares , Oxigênio/metabolismo
8.
Sci Rep ; 8(1): 14586, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30275488

RESUMO

Our understanding of the dynamics of ion collisional energy loss in a plasma is still not complete, in part due to the difficulty and lack of high-quality experimental measurements. These measurements are crucial to benchmark existing models. Here, we show that such a measurement is possible using high-flux proton beams accelerated by high intensity short pulse lasers, where there is a high number of particles in a picosecond pulse, which is ideal for measurements in quickly expanding plasmas. By reducing the energy bandwidth of the protons using a passive selector, we have made proton stopping measurements in partially ionized Argon and fully ionized Hydrogen plasmas with electron temperatures of hundreds of eV and densities in the range 1020-1021 cm-3. In the first case, we have observed, consistently with previous reports, enhanced stopping of protons when compared to stopping power in non-ionized gas. In the second case, we have observed for the first time the regime of reduced stopping, which is theoretically predicted in such hot and fully ionized plasma. The versatility of these tunable short-pulse laser based ion sources, where the ion type and energy can be changed at will, could open up the possibility for a variety of ion stopping power measurements in plasmas so long as they are well characterized in terms of temperature and density. In turn, these measurements will allow tests of the validity of existing theoretical models.

9.
Ann R Coll Surg Engl ; 100(6): 485-490, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29543049

RESUMO

Introduction The free jejunal flap represents the gold standard for circumferential defects in upper digestive tract reconstruction. It is a technically demanding procedure with significant failure rates. Unrecognised failure leads to flap necrosis and potentially fatal sequelae, including sepsis and carotid artery bleed. Despite these catastrophic consequences, however, there remains no consensus on an optimum method for postoperative flap monitoring. Our unit has pioneered the use of external colour duplex ultrasound to monitor flap vascularity. We describe this technique and systematically review other published monitoring systems. Materials and methods A patient underwent oesophageal reconstruction using a jejunal free flap. Monitoring commenced immediately via external application of a colour duplex probe over the flap's vascular pedicle to facilitate flow volume assessment. Further bi-daily assessments were successfully used to monitor the postoperative viability of the flap. The systematic review was conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Results Six alternative monitoring techniques were identified: exteriorised jejunal segment, implantable Doppler probe, watch window, microdialysis, microendoscopy and reflectance photoplethysmography. Discussion Exteriorised jejunal segment and implantable Doppler probe are most commonly described, yet both are associated with high false positive rates, which is particularly significant in a patient demographic facing increased general anaesthetic risk. Most other techniques remain experimental. External colour Doppler ultrasound provides the surgeon with immediate reassurance following the reconstruction, requires minimal training to use, and eliminates the need for revisional procedures. Conclusion Our initial experience suggests that external colour Doppler ultrasound has exciting potential as an efficient and noninvasive technique for monitoring the free jejunal flap.


Assuntos
Esôfago/cirurgia , Retalhos de Tecido Biológico/irrigação sanguínea , Jejuno/irrigação sanguínea , Jejuno/diagnóstico por imagem , Procedimentos de Cirurgia Plástica , Cuidados Pós-Operatórios/métodos , Ultrassonografia Doppler em Cores , Esôfago/diagnóstico por imagem , Feminino , Humanos , Jejuno/transplante , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica/métodos
10.
Burns ; 44(5): 1040-1051, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29398078

RESUMO

INTRODUCTION: Smoke inhalation injury (II) is an independent risk factor for mortality in burns and its management is inherently complex. We aim to make recommendations for best practice in managing II and its sequelae by reviewing all available current evidence in order to provide an evidence-based approach. METHODS: We conducted a systematic search of the Cochrane database and Embase using PRISMA guidelines with no patient population exclusion criteria. Published work was reviewed and evidence levels graded. RESULTS: We identified 521 abstracts for inclusion. Of the 84 articles identified for secondary review, 28 papers were excluded leaving 56 papers suitable for final inclusion. CONCLUSIONS: We are able to identify a number of strategies in both diagnosis and treatment of II that have support in the published literature, including the role of bronchoscopy, permissive hypercapnia, nebulized heparin and hydroxycobalamin. Other strategies have not been shown to be harmful, but their efficacy is also not firmly established, such as high frequency oscillatory ventilation and exogenous surfactant. Prophylactic antibiotics and corticosteroids are not recommended. In general, published evidence for II is mostly Level 3 or below, due to a noticeable lack of large-scale human studies. This represents a challenge for evidence-based burns practice as a whole.


Assuntos
Anti-Infecciosos/uso terapêutico , Anticoagulantes/uso terapêutico , Heparina/uso terapêutico , Ventilação de Alta Frequência/métodos , Surfactantes Pulmonares/uso terapêutico , Lesão por Inalação de Fumaça/terapia , Complexo Vitamínico B/uso terapêutico , Administração por Inalação , Broncoscopia , Medicina Baseada em Evidências , Humanos , Hidroxocobalamina/uso terapêutico , Hipercapnia , Lesão por Inalação de Fumaça/diagnóstico
14.
Phys Rev E ; 95(2-1): 023205, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28297897

RESUMO

Electromagnetic instability is investigated in homogeneous plasmas heated by a laser wave in the range α=v_{0}^{2}/v_{t}^{2}≤2, where v_{0} is the electron quiver velocity and v_{t} is the thermal velocity. The anisotropic electron distribution function that drives unstable quasistatic electromagnetic modes is calculated numerically with the Vlasov-Landau equation in the high ion charge number approximation. A dispersion relation of electromagnetic waves which accounts for further nonlinear terms on v_{0}^{2} from previous results is derived. In typical simulation with ion charge number Z=13, a temperature T=5keV, a density n=9.8×10^{20}cm^{-3}, and a laser wavelength λ_{laser}=1.06µm, growth rates larger than 10^{12}s^{-1} in the quasicollisionless wave-number range were found for α≥1. In the same physical conditions and in the mildly collisional range a growth rate about 10^{11}s^{-1} was also obtained. The extent of the growth wave-number region increases significantly with increasing α.

15.
Science ; 354(6311): 444-448, 2016 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-27789837

RESUMO

The kinetics of the hydroxyl radical (OH) + carbon monoxide (CO) reaction, which is fundamental to both atmospheric and combustion chemistry, are complex because of the formation of the hydrocarboxyl radical (HOCO) intermediate. Despite extensive studies of this reaction, HOCO has not been observed under thermal reaction conditions. Exploiting the sensitive, broadband, and high-resolution capabilities of time-resolved cavity-enhanced direct frequency comb spectroscopy, we observed deuteroxyl radical (OD) + CO reaction kinetics and detected stabilized trans-DOCO, the deuterated analog of trans-HOCO. By simultaneously measuring the time-dependent concentrations of the trans-DOCO and OD species, we observed unambiguous low-pressure termolecular dependence of the reaction rate coefficients for N2 and CO bath gases. These results confirm the HOCO formation mechanism and quantify its yield.

16.
Nat Commun ; 5: 4034, 2014 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-24925314

RESUMO

When two resonant modes in a system with gain or loss coalesce in both their resonance position and their width, a so-called exceptional point occurs, which acts as a source of non-trivial physics in a diverse range of systems. Lasers provide a natural setting to study such non-Hermitian degeneracies, as they feature resonant modes and a gain material as their basic constituents. Here we show that exceptional points can be conveniently induced in a photonic molecule laser by a suitable variation of the applied pump. Using a pair of coupled microdisk quantum cascade lasers, we demonstrate that in the vicinity of these exceptional points the coupled laser shows a characteristic reversal of its pump dependence, including a strongly decreasing intensity of the emitted laser light for increasing pump power.

17.
Phys Rev Lett ; 112(1): 013602, 2014 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-24483898

RESUMO

In this Letter we study a system consisting of two nearly degenerate mechanical modes that couple to a single mode of an optical cavity. We show that this coupling leads to nearly complete (99.5%) hybridization of the two mechanical modes into a bright mode that experiences strong optomechanical interactions and a dark mode that experiences almost no optomechanical interactions. We use this hybridization to transfer energy between the mechanical modes with 40% efficiency.

18.
Rev Sci Instrum ; 84(12): 123104, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24387417

RESUMO

We present and characterize fiber mirrors and a miniaturized ion-trap design developed to integrate a fiber-based Fabry-Perot cavity (FFPC) with a linear Paul trap for use in cavity-QED experiments with trapped ions. Our fiber-mirror fabrication process not only enables the construction of FFPCs with small mode volumes, but also allows us to minimize the influence of the dielectric fiber mirrors on the trapped-ion pseudopotential. We discuss the effect of clipping losses for long FFPCs and the effect of angular and lateral displacements on the coupling efficiencies between cavity and fiber. Optical profilometry allows us to determine the radii of curvature and ellipticities of the fiber mirrors. From finesse measurements, we infer a single-atom cooperativity of up to 12 for FFPCs longer than 200 µm in length; comparison to cavities constructed with reference substrate mirrors produced in the same coating run indicates that our FFPCs have similar scattering losses. We characterize the birefringence of our fiber mirrors, finding that careful fiber-mirror selection enables us to construct FFPCs with degenerate polarization modes. As FFPCs are novel devices, we describe procedures developed for handling, aligning, and cleaning them. We discuss experiments to anneal fiber mirrors and explore the influence of the atmosphere under which annealing occurs on coating losses, finding that annealing under vacuum increases the losses for our reference substrate mirrors. X-ray photoelectron spectroscopy measurements indicate that these losses may be attributable to oxygen depletion in the mirror coating. Special design considerations enable us to introduce a FFPC into a trapped ion setup. Our unique linear Paul trap design provides clearance for such a cavity and is miniaturized to shield trapped ions from the dielectric fiber mirrors. We numerically calculate the trap potential in the absence of fibers. In the experiment additional electrodes can be used to compensate distortions of the potential due to the fibers. Home-built fiber feedthroughs connect the FFPC to external optics, and an integrated nanopositioning system affords the possibility of retracting or realigning the cavity without breaking vacuum.

19.
Opt Express ; 20(21): 23832-7, 2012 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-23188348

RESUMO

We demonstrate terahertz quantum-cascade lasers with a 30 µm thick double-metal waveguide, which are fabricated by stacking two 15 µm thick active regions using a wafer bonding process. By increasing the active region thickness more optical power is generated inside the cavity, the waveguide losses are decreased and the far-field is improved due to a larger facet aperture. In this way the output power is increased by significantly more than a factor of 2 without reducing the maximum operating temperature and without increasing the threshold current.


Assuntos
Lasers , Teoria Quântica , Refratometria/instrumentação , Radiação Terahertz , Desenho de Equipamento , Análise de Falha de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...