1.
PLoS One ; 19(5): e0303066, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38728251

RESUMO

INTRODUCTION: People with chronic neck pain (CNP) commonly exhibit a range of physical impairments including cervical proprioceptive deficits. Assessing proprioception using a head mounted laser to assess joint position error (JPE) is a reliable and valid measure. However, the responsiveness of this measure has not been assessed. OBJECTIVE: To assess the responsiveness of the measure of cervical JPE after a 4-week home-based neck proprioceptive training intervention in people with CNP. DESIGN: An observational study to assess the responsiveness of the measure of cervical JPE. METHODS: The JPE test was assessed in people with CNP before and after 4 weeks of neck proprioception training. JPE was assessed as participants performed neck joint position sense tests for flexion, extension, right rotation, and left rotation in sitting and standing which were performed in a random order. Both the absolute and constant JPE were assessed. The intervention consisted of neck repositioning exercises as well as movement sense exercises. Cohen's d effect size was used to assess the internal responsiveness of the JPE test. The Pearson's correlation was used to assess the change of scores of the laser pointer and measures from inertial measurement units (IMUs) (external responsiveness). RESULTS: After 4 weeks of proprioception training, JPE assessed in sitting reduced from 2.69◦-3.57◦ to 1.88◦-1.98◦ for flexion, extension, and right rotation with large effect sizes (Cohen's d range: 1.25-2.00). For left rotation, JPE reduced from 3.23◦ to 1.9◦, and the effect size was close to being large (Cohen's d: 0.79). When assessed in standing, JPE reduced from 3.49◦-4.52◦ to 1.5◦-2.33◦ with large effect sizes (Cohen's d range: 0.89-1.25) for flexion, extension, right rotation, and left rotation. Large effect sizes were not observed for the constant JPE when assessed in either sitting or standing. The assessment of the external responsiveness revealed weak correlations between the change of scores obtained from the laser pointer and the IMUs for all movements, apart from the constant JPE in sitting for left rotation, which showed a strong correlation (r = 0.7). CONCLUSION: The results of this study showed that the measure of the JPE has sufficient internal responsiveness, however, the external responsiveness was inadequate. Further research is advised.


Assuntos
Cervicalgia , Propriocepção , Humanos , Propriocepção/fisiologia , Feminino , Masculino , Adulto , Cervicalgia/fisiopatologia , Cervicalgia/terapia , Pessoa de Meia-Idade , Terapia por Exercício/métodos , Amplitude de Movimento Articular/fisiologia , Pescoço/fisiologia , Pescoço/fisiopatologia , Vértebras Cervicais/fisiopatologia
2.
J Electromyogr Kinesiol ; 76: 102874, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38547715

RESUMO

The diversity in electromyography (EMG) techniques and their reporting present significant challenges across multiple disciplines in research and clinical practice, where EMG is commonly used. To address these challenges and augment the reproducibility and interpretation of studies using EMG, the Consensus for Experimental Design in Electromyography (CEDE) project has developed a checklist (CEDE-Check) to assist researchers to thoroughly report their EMG methodologies. Development involved a multi-stage Delphi process with seventeen EMG experts from various disciplines. After two rounds, consensus was achieved. The final CEDE-Check consists of forty items that address four critical areas that demand precise reporting when EMG is employed: the task investigated, electrode placement, recording electrode characteristics, and acquisition and pre-processing of EMG signals. This checklist aims to guide researchers to accurately report and critically appraise EMG studies, thereby promoting a standardised critical evaluation, and greater scientific rigor in research that uses EMG signals. This approach not only aims to facilitate interpretation of study results and comparisons between studies, but it is also expected to contribute to advancing research quality and facilitate clinical and other practical applications of knowledge generated through the use of EMG.


Assuntos
Lista de Checagem , Consenso , Técnica Delphi , Eletromiografia , Projetos de Pesquisa , Eletromiografia/métodos , Eletromiografia/normas , Lista de Checagem/normas , Humanos , Projetos de Pesquisa/normas , Reprodutibilidade dos Testes