Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cancer Radiother ; 24(5): 411-417, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32517893

RESUMO

Improved computer resources in radiation oncology department have greatly facilitated the integration of multimodal imaging into the workflow of radiation therapy. Nowadays, physicians have highly informative imaging modalities of the anatomical region to be treated. These images contribute to the targeting accuracy with the current treatment device, impacting both segmentation or patient's positioning. Additionally, in a constant effort to deliver personalized care, many teams seek to confirm the benefits of adaptive radiotherapy. The published works highlight the importance of registration algorithms, particularly those of elastic or deformable registration necessary to take into account the anatomical evolutions of the patients during the course of their therapy. These algorithms, often considered as "black boxes", tend to be better controlled and understood by physicists and physicians thanks to the generalization of evaluation and validation methods. Given the still significant development of medical imaging techniques, it is foreseeable that multimodal registration needs require more efficient algorithms well integrated within the flow of data.


Assuntos
Algoritmos , Imagem Multimodal/métodos , Posicionamento do Paciente/métodos , Radioterapia Guiada por Imagem/métodos , Fracionamento da Dose de Radiação , Feminino , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Imageamento por Ressonância Magnética , Imagem Multimodal/normas , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Controle de Qualidade , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Guiada por Imagem/normas , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia
2.
J Appl Microbiol ; 99(4): 916-25, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16162244

RESUMO

AIMS: To compare the sensitivities of two nested PCR assays for the detection of Legionella pneumophila to each other and to the plate counting technique (ISO 11731) in a wide range of aquatic samples. METHODS AND RESULTS: The nested PCR assay with the primer set LEG 225-LEG 858 revealed 56% of the 46 analysed aquatic samples as being positive for Legionella spp., while the primer set JFP-JRP yielded 98% positive samples. The detection was confirmed by sequencing the PCR products. These results are considerably higher than the result obtained with the plate counting technique (41%), indicating the higher sensitivity of PCR-based diagnostic methods. As the PCR assay with the LEG 225-LEG 858 primer set resulted in a lower number of positive samples, it is considered not sensitive enough for aquatic samples. Similar results for the respective primer sets were obtained for the detection of the species L. pneumophila, responsible for 90% of all human Legionella infections, in the aquatic samples analysed. Both microbial community analysis by PCR-denaturing gradient gel electrophoresis and the analysis of biotic and abiotic water quality parameters revealed no relation between L. pneumophila-positive and -negative samples and the physico-chemical and bacteriological characteristics of the aquatic samples. CONCLUSIONS: The results show the additional value of the PCR assay with the JFP-JRP primer set compared with the plate counting technique, as well as its applicability in a wide range of aquatic samples. SIGNIFICANCE AND IMPACT OF THE STUDY: This study shows the importance of comparing different primer sets for nested PCR assays for the detection of L. pneumophila in aquatic samples, as well as the lower sensitivity of the widely accepted plate counting technique (ISO 11731).


Assuntos
Legionella pneumophila/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Microbiologia da Água , Sequência de Bases , Contagem de Colônia Microbiana/métodos , Meios de Cultura , Primers do DNA/genética , DNA Bacteriano/genética , DNA Ribossômico/genética , Eletroforese/métodos , Citometria de Fluxo/métodos , Filogenia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA