Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Virol ; 50(2): 119-24, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21109484

RESUMO

BACKGROUND: Standardization of quantitative HIV-1 tests to a global primary standard is required by regulatory authorities to ensure comparability of test results across different assays and platforms of different manufacturers. OBJECTIVES AND STUDY DESIGN: Three generations of quantitative HIV-1 tests, the COBAS(®) AMPLICOR(®) HIV-1 Monitor Test, v1.5 (HIV-1 Monitor test v1.5); the COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) HIV-1 Test (HIV-1 TaqMan(®) test v1.0); and the dual-target-based COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) HIV-1 Test, v2.0 (HIV-1 TaqMan(®) test v2.0), were assessed for accuracy to World Health Organization (WHO) 2nd International Standard for human immunodeficiency virus 1 (HIV-1) RNA (NIBSC code 97/650) at concentration levels below 1667 IU/mL including relevant medical decision points. RESULTS: With the 2nd WHO Standard the mean difference across all concentrations was -0.07 log(10) for the HIV-1 Monitor test v1.5; +0.12 log(10) for the HIV-1 TaqMan(®) test v1.0; and +0.09 log(10) for the HIV-1 TaqMan(®) test v2.0. Linearity, including concentrations below the claimed limit of quantitation, was demonstrated for HIV-1 TaqMan(®) test v2.0. The HIV-1 TaqMan(®) test v1.0 showed a trend towards higher quantitation at very low concentration levels and the HIV-1 Monitor test v1.5 had a tendency towards lower quantitation at low concentration levels. CONCLUSIONS: All three assays are closely traceable to the primary WHO HIV-1 RNA standard for in vitro diagnostic IVD assays. Compared to the other two assays, the HIV-1 TaqMan(®) test v2.0 showed better linearity around the limit of detection and below.


Assuntos
Infecções por HIV/diagnóstico , HIV-1/genética , HIV-1/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/normas , RNA Viral/análise , Infecções por HIV/virologia , Humanos , Limite de Detecção , RNA Viral/genética , Padrões de Referência , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/normas , Sensibilidade e Especificidade , Carga Viral , Organização Mundial da Saúde
2.
J Clin Virol ; 49(1): 41-6, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20637687

RESUMO

BACKGROUND: HIV-1 RNA viral load is a key parameter for reliable treatment monitoring of HIV-1 infection. Accurate HIV-1 RNA quantitation can be impaired by primer and probe sequence polymorphisms as a result of tremendous genetic diversity and ongoing evolution of HIV-1. A novel dual HIV-1 target amplification approach was realized in the quantitative COBAS AmpliPrep/COBAS TaqMan HIV-1 Test, v2.0 (HIV-1 TaqMan test v2.0) to cope with the high genetic diversity of the virus. OBJECTIVES AND STUDY DESIGN: The performance of the new assay was evaluated for sensitivity, dynamic range, precision, subtype inclusivity, diagnostic and analytical specificity, interfering substances, and correlation with the COBAS AmpliPrep/COBAS TaqMan HIV-1 (HIV-1 TaqMan test v1.0) predecessor test in patients specimens. RESULTS: The new assay demonstrated a sensitivity of 20 copies/mL, a linear measuring range of 20-10,000,000 copies/mL, with a lower limit of quantitation of 20 copies/mL. HIV-1 Group M subtypes and HIV-1 Group O were quantified within +/-0.3 log(10) of the assigned titers. Specificity was 100% in 660 tested specimens, no cross reactivity was found for 15 pathogens nor any interference for endogenous substances or 29 drugs. Good comparability with the predecessor assay was demonstrated in 82 positive patient samples. In selected clinical samples 35/66 specimens were found underquantitated in the predecessor assay; all were quantitated correctly in the new assay. CONCLUSIONS: The dual-target approach for the HIV-1 TaqMan test v2.0 enables superior HIV-1 Group M subtype coverage including HIV-1 Group O detection. Correct quantitation of specimens underquantitated in the HIV-1 TaqMan test v1.0 test was demonstrated.


Assuntos
Infecções por HIV/diagnóstico , Infecções por HIV/virologia , HIV-1/genética , Reação em Cadeia da Polimerase/métodos , RNA Viral/análise , Kit de Reagentes para Diagnóstico , Carga Viral , HIV-1/isolamento & purificação , Humanos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA